Yaskawa l1000a руководство

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

YASKAWA AC Drive-L1000A

AC Drive for Elevator Applications

Technical Manual

Type: CIMR-LUA

Models: 200 V Class: 1.5 to 110 kW (2 to 150 HP)

400 V Class: 1.5 to 315 kW (2 to 500 HP)

600 V Class: 1.5 to 160 kW (2 to 250 HP)

To properly use the product, read this manual thoroughly and retain

for easy reference, inspection, and maintenance. Ensure the end user

receives this manual.

MANUAL NO. SIEP C710616 38F

1

1

Receiving

2

2

Mechanical Installation

3

3

Electrical Installation

Start-Up Programming &

4

4

Operation

5

5

Parameter Details

6

6

Troubleshooting

Periodic Inspection &

7

7

Maintenance

Peripheral Devices &

8

8

Options

A

A

Specifications

B

B

Parameter List

MEMOBUS/Modbus

C

C

Communications

D

D

Standards Compliance

E

E

Quick Reference Sheet

Chapters

Troubleshooting

loading

Summary of Contents for YASKAWA L1000A

  • 3 фазы 200В, от 4…110 кВт
  • 3 фазы 400В, от 4…110 кВт
  • Работа с одним двигателем
  • Функция торможения позволяет добится плавного входа
  • Пять независимых настроек S-кривых для предотвращения рывков
  • Возможность использования обратной связи энкодера и обнаружение нагрузки позволяет увеличить точность выравнивания лифта
  • Модели со встроенным тормозным ключом
  • Возможность автонастройки с вращением и без
  • Диапазон выходных частот от 0 до 120 Hz
  • Возможность работы с импульсным блоком питания

Частотный преобразователь YASKAWA L1000A является новым приводом специального назначения для лифтового применения. Частотный преобразователь обеспечивает расширенные функции управления для запуска лифта, предназначен для работы с асинхронными двигателями в редукторных или безредукторных системах лифта.Компания Вектор Технологий СПБ (Санкт-Петербург)-официальный дистрибьютор компании YASKAWA на территории Российской Федерации.

Бренд
Yaskawa
Страна
Япония
Сегмент
Лифтовые частотные преобразователи
Тип
Преобразователь частоты
Гарантия
3 года
  • Техническое руководство YASKAWA L1000A.pdf

    Размер: 14 Мб

  • Быстрый запуск YASKAWA L1000A.pdf

    Размер: 2 Мб

  • L1000A new.PDF

    Размер: 52 Мб

  • Инструкция по настройке L1000A 400V 2.22 U.pdf

    Размер: 4 Мб

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

YASKAWA AC Drive-L1000A

AC Drive for Elevator Applications

Technical Manual

Type: CIMR-LU A

Models: 200 V Class: 3.7 to 110 kW (5 to 150 HP)

400 V Class: 3.7 to 132 kW (5 to 200 HP)

To properly use the product, read this manual thoroughly and retain

for easy reference, inspection, and maintenance. Ensure the end user

receives this manual.

MANUAL NO. SIEP C710616 38A

1

Receiving

2

Mechanical Installation

3

Electrical Installation

Start-Up Programming &

4

Operation

5

Parameter Details

6

Troubleshooting

Periodic Inspection &

7

Maintenance

Peripheral Devices &

8

Options

A

Specifications

B

Parameter List

C

MEMOBUS/Modbus

Communications

D

Standards Compliance

E

Quick Reference Sheet

Chapters

Troubleshooting

loading

Summary of Contents for YASKAWA L1000A

(Ocr-Read Summary of Contents of some pages of the YASKAWA L1000A Document (Main Content), UPD: 05 August 2023)

  • 377, B.3 Parameter Table YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 377 Parameter List B U4-21 (7DDH) Up/Down Command Source Selection Displays the source for the Up/Down command as XY-nn. X: Indicates which Up/Down command source is used: 1 = Reference 1 (b1-02) Y: Input power supply data 0 = Digital operator 1 = External terminals 3 = MEMOBUS/Modbus communications 4 = Communication option card nn: Up/Down command limit status data 00: No l…

  • 318, 318 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 8.5 Installing Peripheral Devices 8.5 Installing Peripheral Devices This section describes the proper steps and precautions to take when installing or connecting various peripheral devices to the drive. NOTICE: Use a class 2 power supply (UL standard) when connecting to the control terminals. Improper application of peripheral devices cou…

  • 55, 3.3 Main Circuit Connection Diagram YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 55 Electrical Installation 3 3.3 Main Circuit Connection Diagram Refer to the Table 3.1 when wiring the main circuit of the drive. Connections may vary based on drive capacity. The DC power supply for the main circuit also provides power to the control circuit. NOTICE: Do not use the negative DC bus …

  • 216, 5.8 L: Protection Functions 216 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual Figure 5.40 Figure 5.40 Overload Tolerance for Braking Transistor (CIMR-L2A0018 to 2A0115, CIMR-L4A0009 to 4A0060) ■ L8-77: Oscillation Suppression If speed oscillations with the same frequency as the output frequency occur with an unloaded motor, parameter L8-77 can be adjusted to suppress these oscillation…

  • 280, 280 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 6.7 Copy Function Related Displays 6.7 Copy Function Related Displays ◆ Tasks, Errors, and Troubleshooting The table below lists the messages and errors that may appear when using the Copy function. When executing the tasks offered by the Copy function, the operator will indicate the task being performed. When an error occurs, a co…

  • 214, YASKAWA L1000A 5.8 L: Protection Functions 214 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ■ L8-12: Ambient Temperature Setting If the temperature where the drive is mounted is above the specified values, the drive rated current must be reduced for optimal performance life. By setting the ambient temperature to parameter L8-12 and adjusting the installation method setting in L8-35, the drive ratin…

  • 30, 1.3 Model Number and Nameplate Check 30 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ■ Model Code Table 1.2 Model Code Three-Phase 200 V Three-Phase 400 V No. Max. Motor Capacity kW(HP) Rated Output Current A No. Max. Motor Capacity kW(HP) Rated Output Current A 0018 3.7 (5) 17.5 0009 3.7 (5) 9.2 0025 5.5 (7-1/2) 25 0015 5.5 (7-1/2) 14.8 0033 7.5 (10) 33 0018 7.5 (10) 18 0047 11 (15) 47 0024 11 (15) 24 0060 15 (20) 60 0031…

  • 174, 5.5 E: Motor Parameters 174 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ◆ E4: Motor 2 Parameters E4 parameters contain the motor data for motor 2. These parameters are usually set automatically during the Auto-Tuning process for vector control modes (Rotational Auto-Tuning, Stationary Auto-Tuning 1 and 2). They may need to be set manually if there is a problem performing Auto-Tuning…

  • 238, YASKAWA L1000A 5.11 S: Elevator Parameters 238 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ■ S4-05: Rescue Operation Torque Limit Sets a time limit for Light Load Direction Search. ■ S4-06: Rescue Operation Power Supply Selection Specifies the type of backup power supply the drive should switch to when the power goes out. 0: Battery 1: UPS (single-phase) 2: UPS (three-phase) ■ S4-0…

  • 46, 2.2 Mechanical Installation 46 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual

  • 452, YASKAWA AMERICA, INC. 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310 http://www.yaskawa.com DRIVE CENTER (INVERTER PLANT) 2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan Phone: 81-930-25-3844 Fax: 81-930-25-4369 http://www.yaskawa.co.jp YASKAWA ELECTRIC CORPORATION New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minat…

  • 305, 7.5 Drive Replacement YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 305 Periodic Inspection & Maintenance 7 7.5 Drive Replacement ◆ Serviceable Parts The drive contains some serviceable parts. The following parts can be replaced over the life span of the drive: • Terminal board I/O PCBs • Cooling fan(s) Front cover Replace the drive if the main power circuitry is damaged. Contact your local Yaskawa representative…

  • 396, C.8 Message Examples 396 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ◆ Writing to Multiple Registers Function code 10H allows the user to write multiple drive MEMOBUS/Modbus registers with one message. This process works similar to reading registers, in that the address of the first register to be written and the data quantity are set in the command message. The data to be written m…

  • 88, YASKAWA L1000A 4.2 Using the Digital Operator 88 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ◆ LO/RE LED and RUN LED Indications Table 4.3 LO/RE LED and RUN LED Indications Figure 4.3 Figure 4.3 RUN LED Status and Meaning Figure 4.4 Figure 4.4 RUN LED and Drive Operation LED Lit Flashing Flashing Quickly <1> <1> Refer to Figure 4.3 for the difference between “flashing” …

  • 297, 7.4 Drive Cooling Fans and Circulation Fans YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 297 Periodic Inspection & Maintenance 7 ◆ Cooling Fan Replacement: 2A0085, 2A0115, 4A0045, and 4A0060 WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious personal injury. Before servicing the drive, disco…

  • 28, 1.2 General Description 28 YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual ◆ Control Mode Selection Table 1.1 gives an overview of the L1000A motor control method (control modes) and their various features. Table 1.1 Control Modes and their Features Motor Type Induction Motors Permanent Magnet Motors Comments Control Mode V/f OLV CLV CLV /PM – Parameter Setting A1-02 = 0 A1-02 = 2…

  • 109, 4.5 Auto-Tuning YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 109 Start-Up Programming & Operation 4 Note: Refer to Parameter Settings during Induction Motor Auto-Tuning: T1 on page 110 for details. ■ Starting Auto-Tuning WARNING! Sudden Movement Hazard. The drive and motor may start unexpectedly during Auto-Tuning, which could result in death or serious injury. Ensure the areas surrounding the drive, motor and load are clear before proceeding with Auto-…

  • 217, YASKAWA L1000A 5.9 n: Special Adjustments YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 217 Parameter Details 5 5.9 n: Special Adjustments These parameters handle a variety of specialized adjustments and functions, including AFR Control, resistance between motor lines, PM motor control functions, and current detection adjustments. ◆ n2: Speed Feedback Detection Control (AFR) Tuning These parameters are used to ac…

  • 285, YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual 285 7 Periodic Inspection & Maintenance This chapter describes the periodic inspection and maintenance of the drive to ensure that it receives the proper care to maintain overall performance. 7.1 SECTION SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286 7.2 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …

Понравилась статья? Поделить с друзьями:
  • Руководство по судебной медицине хохлов скачать
  • Сейзар таблетки инструкция по применению цена
  • Инструкция по эксплуатации sven ps 650
  • Спиртовая настойка пустырника инструкция по применению
  • Кетонал гель для чего применяется инструкция по применению взрослым