U s robotics 56k faxmodem инструкция

US Robotics 56K FAXMODEM Quick Installation Manual

  • Bookmarks

Quick Links

56K Faxmodem

Quick Installation Guide

English

Français

Deutsch

Italiano

Nederlands

Español

Part Number R24.0386.00

Model #5630

loading

Related Manuals for US Robotics 56K FAXMODEM

Summary of Contents for US Robotics 56K FAXMODEM

  • Page 1
    56K Faxmodem Quick Installation Guide English Français Deutsch Italiano Nederlands Español Part Number R24.0386.00 Model #5630…
  • Page 3
    T T T T T able of Contents able of Contents able of Contents able of Contents able of Contents English English …………………………………………..4 4 4 4 4 English English English …………………………….F F F F F r r r r r ançais ançais ançais …………….
  • Page 4
    U.S. Robotics Corporation 935 National Parkway Schaumburg, Illinois 60173 No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without writ- ten permission from U.S. Robotics Corporation. U.S.
  • Page 5
    All Windows Operating Systems Installation Step1: Prepare for installation NOT T T T T E E E E E : Before you begin, we recommend you uninstall any other modems you have in your system. Refer to your previous modem’s documentation for instructions.
  • Page 6
    If you have Windows 2000: Step 5: Update the driver from the Installation CD-ROM Click Windows Start, Settings, and Control Panel. Double-click System, click the Hardware tab, and click the Device Manager button. Click to expand Modems, and double-click Standard Modem. Click the Driver tab and click the Update Driver button. When the Upgrade Device Driver window appears, click Next.
  • Page 7
    success. If your modem is not listed and/or you do not see a series of commands and responses, check that all connectors and power cables are properly connected to your modem and the back of your computer. Check that the modem is switched on and the CS or the PWR light is illuminated.
  • Page 8: Support Resources

    • The telephone line between your ISP and your modem must be capable of supporting a 56K connection and contain only one analogue-to-digital conversion. The 56K signal from your ISP begins as a digital signal. Somewhere between the ISP and your modem, there will be a digital-to-analogue signal conversion so that your modem can receive the data.

  • Page 9: Regulatory Information

    Regulatory Information CE Compliance We, U.S. Robotics Corporation of 935 National Parkway, Schaumburg, Illinois, 60173-5157 USA, declare under U.S. Robotics 56K Faxmodem, our sole responsibility that the product, Model 5630, to which this declaration relates, is in conformity with the following standards and/or other normative documents. EN60950 EN55022 EN55024…

  • Page 10: General Terms

    U.S. Robotics Corporation Limited Warranty GENERAL TERMS: GENERAL TERMS: GENERAL TERMS: GENERAL TERMS: GENERAL TERMS: This Limited Warranty is extended only to the original end-user purchaser (CUSTOMER) and is not transferable. No agent, reseller, or business partner of U.S. Robotics Corporation (U.S. ROBOTICS) is authorised to modify the terms of this Limited Warranty on behalf of U.S.

  • Page 11: Warranty Replacement

    WARRANTY REPLACEMENT: WARRANTY REPLACEMENT: WARRANTY REPLACEMENT: WARRANTY REPLACEMENT: WARRANTY REPLACEMENT: In the event U.S. ROBOTICS Technical Support or its authorised U.S. ROBOTICS Service Centre determines the product or part has a malfunction or failure attributable directly to faulty workmanship and/or materials; and the product is within the TWO (2) YEAR warranty term; and the CUSTOMER will include a copy of the dated Proof of Purchase (original purchase receipt from U.S.

  • Page 12
    LIMITATION OF LIABILITY. TO THE FULL EXTENT ALLOWED BY LAW, U.S. ROBOTICS ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF U.S.
  • Page 13
    13 13 13 13 13…
  • Page 14
    U.S. Robotics Corporation 935 National Parkway Schaumburg, Illinois 60173, Etats-Unis Il est interdit de reproduire cette documentation, que ce soit en tout ou en partie, sous quelque forme ou par quelque moyen que ce soit en vue d’effectuer des travaux dérivés (tels que traduction, transformation ou adaptation) sans la permission écrite de U.S.
  • Page 15
    Pour tous les systèmes d’exploitation Windows Etape 1 : préparation de l’installation. R R R R R E E E E E M M M M M A A A A A R R R R R QUE QUE : avant de procéder à l’installation, nous vous conseillons de désinstaller tout autre modem faisant partie de votre système.
  • Page 16: Dépannage

    vous saurez quel port COM est attribué à votre modem. Cliquez sur Fermer Fermer Fermer Fermer. Lorsque la Fermer fenêtre « Modification des paramètres système » apparaît à l’écran, cliquez sur Oui pour redémarrer votre ordinateur. Si vous disposez de Windows 2000 : Etape 5 : mise à…

  • Page 17
    Panneau de configuration, en suivant la procédure décrite plus haut. Avec Windows NT : cliquez sur Démarr Démarr Démarr Démarr Démarrer er er er er, P P P P P ar ar ar ar aramètr amètr amètr amètr amètres es es es es, puis sur P P P P P anneau de configu- anneau de configu- anneau de configu- anneau de configu-…
  • Page 18
    PROBLEME : mon modem n’atteint pas une vitesse de connexion PROBLEME : mon modem n’atteint pas une vitesse de connexion PROBLEME : mon modem n’atteint pas une vitesse de connexion PROBLEME : mon modem n’atteint pas une vitesse de connexion PROBLEME : mon modem n’atteint pas une vitesse de connexion Internet 56K.
  • Page 19: Informations Légales

    Pays Téléphone Adresse électronique Horaires d’ouverture France 0825 07 06 93 france_modemsupport@usr.com 9h — 18h, du lundi au vendredi Angleterre +44 870 844 4546 uk_modemsupport@usr.com 9h — 17h30, du lundi au vendredi Suisse 0848 84 02 00 emea_modemsupport@usr.com 8h — 18h, du lundi au vendredi Informations légales Conformité…

  • Page 20
    Garantie limitée de U.S. Robotics Corporation CONDITIONS GENERALES : CONDITIONS GENERALES : CONDITIONS GENERALES : CONDITIONS GENERALES : CONDITIONS GENERALES : Cette garantie limitée ne s’applique qu’à l’acheteur d’origine (le CLIENT) et n’est pas transférable. Aucun agent, revendeur ou partenaire commercial de U.S. Robotics Corporation (U.S. ROBOTICS) n’est autorisé…
  • Page 21
    R R R R R E E E E E M M M M M PL PL PL PL PLA A A A A CE CEM M M M M E E E E E NT NT DE L DE L DE L DE L DE LA G…
  • Page 22
    DANS LA MESURE OU LA LOI LE PERMET, LES GARANTIES ET LES RECOURS PRECEDEMMENT CITES SONT EXCLUSIFS ET REMPLACENT LES AUTRES GARANTIES, TERMES OU CONDITIONS, EXPLICITES OU IMPLICITES, DE FACTO OU DE JURE, STATUTAIRES OU AUTRES, NOTAMMENT LES GARANTIES, TERMES OU CONDITIONS DE COMMERCIALISATION, D’ADAPTATION A UN USAGE PARTICULIER, DE QUALITE SATISFAISANTE, DE CORRESPONDANCE A LA DESCRIPTION FOURNIE ET DE NON- INFRACTION, QUI SONT TOUS EXPRESSEMENT REJETES.
  • Page 24
    U.S. Robotics Corporation 935 National Parkway Schaumburg, Illinois 60173 Kein Teil dieser Dokumentation darf ohne schriftliche Genehmigung der U.S. Robotics Corpo- ration in irgendeiner Form oder mit irgendwelchen Mitteln vervielfältigt oder für irgendwelche Weiterbearbeitung (beispielsweise Übersetzung, Konvertierung oder Anpassung) verwendet werden. Die U.S.
  • Page 25
    Installation unter allen Windows-Betriebssystemen Schritt 1: Vorbereitung der Installation H H H H H I I I I I NW NWE E E E E I I I I I S S S S S : Vor der Installation empfehlen wir Ihnen, zunächst alle anderen Modems von Ihrem Computer zu deinstallieren.
  • Page 26
    Sie U.S. Robotics 56K Ext (non-PnP).Klicken Sie auf OK und dann auf Weiter. Auf der Registerkarte für die Eigenschaften der Modems wird der COM-Anschluss angezeigt, der dem Modem zugewiesen wurde. Klicken Sie auf Schließen. Wenn das Fenster Geänderte Geänderte Geänderte Geänderte Geänderte ystemeinstellungen angezeigt wird, klicken Sie auf Ja, um Ihren Computer neu zu starten.
  • Page 27
    Vergewissern Sie sich, dass das Modem eingeschaltet ist und die CS- oder PWR-LED leuchtet. Fahren Sie Ihren PC herunter und starten Sie ihn neu. Überprüfen Sie Ihr Modem erneut in der Systemsteuerung (siehe Beschreibung oben). Windows NT: Klicken Sie auf S S S S S tart tart tart tart, Einstellungen…
  • Page 28
    PROB OBL L L L L E E E E E M: Mein Modem scheint mit einem ander M: Mein Modem scheint mit einem ander M: Mein Modem scheint mit einem ander M: Mein Modem scheint mit einem anderen Modem en Modem en Modem en Modem V V V V V erbindung…
  • Page 29
    Land Telefon Online Öffnungszeiten Deutschland 018056715 48 germany_modemsupport@usr.com 8:00 — 18:00 Uhr, Montag — Freitag Großbritannien +44 870 844 4546 uk_modemsupport@usr.com 9:00 — 17:30 Uhr, Montag — Freitag Schweiz 0848 840 200 emea_modemsupport@usr.com 8:00 — 18:00 Uhr, Montag — Freitag Hinweise zu Vorschriften CE-Konformität Wir, die U.S.
  • Page 30
    Beschränkte Garantie der U.S. Robotics Corporation A A A A A LL LL LL LL LLG G G G G E E E E E M M M M M E E E E E I I I I I N N N N N E B E BE E E E E DI DI DI DI DING NGU U U U U NG NGE E E E E N: N: N: N: N:…
  • Page 31
    · Datierter Kaufbeleg · Name und Telefonnummer des KUNDEN · Version des Betriebssystems des KUNDEN · U.S. ROBOTICS Installations-CD-ROM · U.S. ROBOTICS Installationsanleitung E E E E E RSA RSATZ I TZ I TZ I TZ I TZ IM RAH M RAH M RAH M RAH…
  • Page 32
    auf Unfälle, Missbrauch, falschen Gebrauch (einschließlich, aber nicht beschränkt auf fehlerhafte Installation oder Anschluss an die falsche Spannungsquelle bzw. Steckdose) zurückzuführen sind; Fehler, die durch Produkte hervorgerufen wurden, die nicht von U.S. ROBOTICS bereitgestellt wurden; Schäden durch Feuchtigkeit, Korrosion in der Umgebung, Hochspannungsströme, Transport oder ungewöhnliche Arbeitsbedingungen;…
  • Page 34
    U.S. Robotics Corporation 935 National Parkway Schaumburg, Illinois 60173 Questa documentazione non può essere né parzialmente né interamente riprodotta in alcuna forma o utilizzata per ottenere opere derivate (quali traduzioni, trasformazione o adattamento) senza l’autorizzazione scritta di U.S. Robotics Corporation. U.S.
  • Page 35
    Installazione con tutti i sistemi operativi Windows Fase 1. Preparazione per l’installazione. NOT T T T T A: A: A: A: A: prima di iniziare, si consiglia di disinstallare eventuali altri modem installati nel sistema. Consultare la documentazione fornita con il vecchio modem per ulteriori informazioni.
  • Page 36: Risoluzione Di Problemi

    Next Next Fare clic su OK OK e quindi su Next Next Next (Avanti). Nella scheda delle proprietà del modem verrà visualizzata la porta COM assegnata al modem. Fare clic su Close Close Close Close (Chiudi). Se appare la Close finestra Modifica delle impostazioni di sistema, fare clic su Sì…

  • Page 37
    Windows 2000/XP: fare clic su Start, Impostazioni Start, Impostazioni Start, Impostazioni Start, Impostazioni (se applicabile), quindi su Start, Impostazioni P P P P P annello di controllo annello di controllo annello di controllo annello di controllo. Fare doppio clic sull’icona Opzioni modem e telefono annello di controllo Opzioni modem e telefono Opzioni modem e telefono…
  • Page 38: Supporto Tecnico

    PROBLEMA: il modem non raggiunge una connessione Internet a 56K. PROBLEMA: il modem non raggiunge una connessione Internet a 56K. PROBLEMA: il modem non raggiunge una connessione Internet a 56K. PROBLEMA: il modem non raggiunge una connessione Internet a 56K. PROBLEMA: il modem non raggiunge una connessione Internet a 56K.

  • Page 39: Informazioni Di Conformità

    Paese Telefono E-mail Orario Italia 848 809 903 italy_modemsupport@usr.com 9:00 — 18:00, lunedì — venerdì Regno Unito +44 870 844 4546 uk_modemsupport@usr.com 9:00 — 17:30, lunedì — venerdì Informazioni di conformità Conformità CE U.S. Robotics Corporation (935 National Parkway, Schaumburg, Illinois, 60173-5157, USA) dichiara, sotto la propria responsabilità, che U.S.

  • Page 40
    Garanzia limitata di U.S. Robotics Corporation C C C C C ON ONDIZ DIZION IONI G I GE E E E E N N N N N E E E E E RA RALI LI LI LI LI La presente garanzia limitata è concessa esclusivamente all’utente/acquirente originale (CLIENTE) e non è…
  • Page 41
    · CD-ROM di installazione U.S. ROBOTICS · Guida all’installazione U.S. ROBOTICS SOST T T T T ITU ITUZ Z Z Z Z ION IONE I E I E I E I E IN G N GA A A A A RA RAN N N N N Z Z Z Z Z IA IA IA IA IA Nel caso in cui il supporto tecnico U.S.
  • Page 42
    FATTO O AI SENSI DELLA LEGGE, STATUTARIE O DI ALTRA NATURA, COMPRESE LE GARANZIE O LE CONDIZIONI DI COMMERCIABILITÀ, IDONEITÀ A SCOPI PARTICOLARI, QUALITÀ SODDISFACENTE, CORRISPONDENZA ALLA DESCRIZIONE E NON VIOLAZIONE, RISPETTO ALLE QUALI SI DECLINA OGNI RESPONSABILITÀ. U.S. ROBOTICS NON SI ASSUME NÉ AUTORIZZA ALTRE PERSONE AD ASSUMERE PER SUO CONTO ULTERIORI RESPONSABILITÀ…
  • Page 44
    U.S. Robotics Corporation 935 National Parkway Schaumburg, Illinois 60173 Geen enkel onderdeel van deze documentatie mag worden gereproduceerd in welke vorm of op welke wijze ook, of mag worden gebruikt als bron voor afgeleide materialen (zoals vertalingen, transformaties of aanpassingen), zonder de schriftelijke toestemming van U.S. Robotics Corporation.
  • Page 45
    Installatie voor alle Windows-besturingssystemen Stap 1: installatie voorbereiden OPME E E E E RK RKI I I I I NG: NG: Het is raadzaam andere modems uit uw systeem te verwijderen voordat u begint. Raadpleeg de documentatie bij uw vorige modem voor aanwijzingen.
  • Page 46
    ziet u welke COM-poort aan uw modem is toegewezen. Klik op Sluiten. Als het venster Systeeminstellingen wijzigen verschijnt, klikt u op Ja om uw computer opnieuw op te starten. Gebruikers van Windows 2000: Stap 5: het stuurprogramma bijwerken met de installatie-cd Klik in Windows op Start, Instellingen en Configuratiescherm.
  • Page 47
    Gebruikers van Windows NT: Klik in Windows op S S S S S tart, Instellingen tart, Instellingen tart, Instellingen tart, Instellingen tart, Instellingen, en vervolgens op Configur Configur Configur Configur Configuratiescherm atiescherm atiescherm atiescherm. Dubbelklik op het pictogram Modems atiescherm Modems Modems Modems.

This manual is also suitable for:

5630

More products and manuals for Modems US Robotics

Models Document Type

USR5699B
Installation Guide

  
US Robotics USR5699B modems,

2 pages


USR205630D
Installation Guide

     
US Robotics USR205630D,

47 pages


USR5633A
Installation Guide

    
US Robotics USR5633A Installation guide,

54 pages


56 K SOFTMODEM — COMMAND REFERENCE REV 1
User Manual

 
56K Softmodem Command Reference,

108 pages


56 K SOFTMODEM — COMMAND REFERENCE REV 1
User Manual

 
US Robotics 56 K SOFTMODEM — COMMAND REFERENCE REV 1 Product data,

158 pages


56K PCI FAXMODEM — QUICK REV 1
Installation Guide

 
US Robotics 56K PCI FAXMODEM — QUICK REV 1 Installation guide,

20 pages


56K MESSAGE MODEM — QUICK FOR WINDOWS
User’s Guide

 
US Robotics 56K MESSAGE MODEM — QUICK FOR WINDOWS User`s guide,

84 pages


56K MESSAGE MODEM — QUICK FOR WINDOWS
User’s Guide

 
US Robotics 56K MESSAGE MODEM — QUICK FOR WINDOWS User`s guide,

75 pages


56K FAXMODEM USB — FOR WINDOWS REV 1.1
User Manual

 
US Robotics 56K FAXMODEM USB — FOR WINDOWS REV 1.1 User manual,

26 pages


USR5660A
Installation Guide

  
US Robotics USR5660A Installation guide,

30 pages


3Com
User Manual

 
US Robotics 3Com User manual,

101 pages


USR0756-CB
Installation Guide

 
US Robotics USR0756-CB Installation guide,

24 pages


56K PCI FAXMODEM — QUICK REV 1
Installation Guide

 
US Robotics 56K PCI FAXMODEM — QUICK REV 1 Installation guide,

44 pages


56K INTERNAL VOICE FAXMODEM — QUICK FOR WINDOWS REV 1.2
Installation Guide

    
US Robotics 56K INTERNAL VOICE FAXMODEM — QUICK FOR WINDOWS REV 1.2 Installation guide,

80 pages


56K PCI FAXMODEM — QUICK REV 1
Installation Guide

 
US Robotics 56K PCI FAXMODEM — QUICK REV 1 Installation guide,

16 pages


Sportster Flash x2
User Manual

 
MP/8 x2 MP/16 x2 NETServer/8 x2 NETServer/16 x2,

27 pages


USR5639
Datasheet

 
US Robotics 56K USB Softmodem,

2 pages


USR5686F-VAR-20
Installation Guide

 
US Robotics USR5686F-VAR-20 modems,

2 pages

(Ocr-Read Summary of Contents of some pages of the US Robotics 56K SERIAL CONTROLLER FAXMODEM Document (Main Content), UPD: 18 September 2023)

  • 88, US Robotics 56K SERIAL CONTROLLER FAXMODEM 56K USB Modem User Guide Command Reference — 82 Voice Commands: Telephone Answering Device (TAD) +VLS=?—Analog Source/Destination Selection and DTMF/Tone Reporting Requests for the modem’s DTMF/tone reporting capabilities are made using this command. For each system configuration in voice mode (i.e., speakerphone and answering machine), the modem reports the capabilities that are enabled for the configura…

  • 13, 56K USB Modem User Guide Command Reference — 7 Command Reference How to Use These Commands USRobotics’ AT command set for controller-based modems consists of commands based on data, FAX, and voice communications. The commands presented in this manual follow the conventions set by ITU-T Recommendation V.250 (05/99), which standardized many of the common AT extensions. This section identifies the r…

  • 23, 56K USB Modem User Guide Command Reference — 17 L<value>—Speaker Volume Use this command to set the speaker volume setting when the speaker is on. Result codes: • OK if <value> = 0—3. • ERROR if <value> ≠ 0—3. Receive Signal Power Level (–dBm) The received signal power, although labeled with units of –dBm, is only a relative measure for comparing calls to/from different locations. This value…

  • 85, 56K USB Modem User Guide Command Reference — 79 +VGR=<gain>—Receive Gain Selection Use this command to set the receive microphone gain control. The receive gain has a range of 0—255. However, the values are only significant between 121 and 134. Any value set below 121 uses the same gain as 121. And any value set above 134 uses the same gain as 134. Note: While in TAD mode, this command may be used in TAD local recording to control the recording level from the…

  • 117, 56K USB Modem User Guide Command Reference — 111 Example #2: Initiating a Stored Number Speakerphone Call The speakerphone application is loaded. The modem is initially idle in data mode. The user then decides to place a speakerphone call either by entering the number without first going off-hook or by selecting a number previously stored in the application. When the user tells the application to dial, the follo…

  • 35, 56K USB Modem User Guide Command Reference — 29 &Z<location>=<stored_number>—Store Telephone Number Use this command to store a dialing string. Controller-based modems can save four dialing sting. The format for the command is &Z<storage_location> = <dialing_string>. The dial string may contain up to 40 characters. The ATDS=<storage_location> command (D<di…

  • 21, US Robotics 56K SERIAL CONTROLLER FAXMODEM 56K USB Modem User Guide Command Reference — 15 H<value>—Hook Control This command 1 instructs the modem to go on-hook to disconnect a call or go off-hook to make the telephone line busy. Result codes: • OK if <value> = 0—1. • ERROR if <value> ≠ 0—1. I<value>—Request ID Information Use this command to display product information about the modem. In each case, the information is transmitted to the host system followed by …

  • 114, 56K USB Modem User Guide Command Reference — 108 * EC only appears when the extended result codes configuration option is enabled. EC is replaced by one of the following symbols, depending on the error control method used: V.44—V.44 data compression. V42bis—V.42 error control and V.42bis data compression. V42—V.42 error control only. MNP 5—MNP class 4 error control and MNP class 5 data compression. MNP 4—MNP class 4 error contr…

  • 73, 56K USB Modem User Guide Command Reference — 67 +FMS=<value>—Minimum Phase C Speed Control Use this command to limit the lowest negotiable speed for a session. The value is the same as the BR parameter in the +FCC valid parameter table. Result codes: • OK if <value> = 0—5. • ERROR if <value> ≠ 0—5. +FNC—Report Nonstandard Command (NSC) Frames The +FNC:<NSC FIF string> response reports any received nonstandard command frame, one response pe…

  • 133, US Robotics 56K SERIAL CONTROLLER FAXMODEM 56K USB Modem User Guide Troubleshooting — 127 Troubleshooting General This procedure addresses a number of symptoms that you might experience with your modem. 1. Verify that the cables are connected correctly. This includes all cables connecting the telephone line, the modem, and your computer. 2. If possible, test your modem with a different phone cord and/or wall jack. 3. Try a different USB port on the computer. If a USB hub is being used, try plugging directly …

  • 40, 56K USB Modem User Guide Command Reference — 34 %B—View Numbers in Blacklist When the blacklisting option is active, use this command to display the telephone numbers and status of any failed or troubled calls. The blacklisting option is associated with the country selection. Some countries have national requirements that prohibit repeat calls to the same number through automatic dialing. Blacklisting 1 is a method of ha…

  • 136, 56K USB Modem User Guide Troubleshooting — 130 My communication software does not recognize the modem. Solution 1: Your communication software may not function properly if any of the following are true: • More than one version of the software is installed on your computer. • You are using an old version of the software. • More than one communication software package is installed on your computer. • USRobotics highly recommends using the co…

  • 41, 56K USB Modem User Guide Command Reference — 35 %E<value>—Auto Fallback/Fallforward Control This command provides the option for the modem to automatically monitor line quality, to fall back when line quality is insufficient, and to fall forward when line quality is sufficient. Result codes: • OK if <value> = 0—2. • ERROR if <value> ≠ 0—2. +A8E=<v8o>,<v8a>,<v8cf>,<v8b>—V.8 and V.8bis Operation Controls Use this co…

  • 62, US Robotics 56K SERIAL CONTROLLER FAXMODEM 56K USB Modem User Guide Command Reference — 56 +FAP=<sub>,<sep>,<pwd>—Address and Polling Capabilities +FAP=<sub>,<sep>,<pwd> is used by DTE to indicate its capability regarding subaddressing, selective polling, and passwords. It is also used by DTE to indicate its willingness to accept this information. The remote station is notified of these capabilities in the DIS or DTC frames: bit 47 for SEP, bit 49 for SUB, and bit 50 f…

  • 111, 56K USB Modem User Guide Command Reference — 105 S71—Silence Sensivity This S-register sets the sensivity for detecting silence over the modem. • Range: 0—255 • Default: 128 • Units: dB S72—Silence Detect Timer This register defines length of time that silence (based on the sensitivity setting) waits before reporting silence to the application (in the form of a callback function). • Range: 0—255 • Default: 50 (5 s). • Units: 1/10 s. S82—En…

  • 96, 56K USB Modem User Guide Command Reference — 90 Table 204. #UD Last Call Status Report Format Note: Refer to Table 1 in the Microsoft specification. Key Value(s) Required Definition Implemented 0 2 digits Yes Diagnostic command specification revision number, digit.digit. X 1 See Table 205 on page 92. 0—A Call setup result code. X 2 See Table 3* 0—1 Multimedia mode. — 3 See Table 4* 0 DTE-DCE interface mode. …

  • 24, 56K USB Modem User Guide Command Reference — 18 M<value>—Speaker Control Use this command to turn the speaker on and off. Result codes: • OK if <value> = 0—3. • ERROR if <value> ≠ 0—3. Note: ITU-T Recommendation V.250 (05/99) standardized this command. However, the standard does not include the additional functionality added with the M3 command. N<value>—Modulatio…

[Page 1] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide R46.1999.00 rev 1 5/08

[Page 2] US Robotics 56K SERIAL CONTROLLER FAXMODEM

[Page 3] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide iii Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Physical Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ….

[Page 4] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide iv Uninstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 My PWR LED is not lit….

[Page 5] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide v 56K USB Modem User Guide U.S. Robotics Corporation 935 National Parkway Schaumburg, Illinois 60173-5157 USA No part of this documentation may be reproduced in any form or by any means or used to make any derivative wo…

[Page 6] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide vi

[Page 7] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Introduction — 1 English Introduction The USRobotics 56K USB Modem delivers the performance and reliability USRobotics is known for, in a compact, flexible form factor. This controller-based modem integrates powerful commun…

[Page 8] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Introduction — 2 Physical Features System Requirements Operating System • Windows Vista™, Windows ® XP, or Windows ® 2000 • Linux kernel 2.4.20 or higher • Mac OS X 10.4.3 or later Other • Intel Pentium III 600…

[Page 9] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Installation Instructions — 3 Installation Instructions Step One: Prepare for Installation 1. Go to the USRobotics website to download the most current drivers for your modem: www.usr.com 2. Uninstall all other modems that a…

[Page 10] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Installation Instructions — 4 4. When prompted, insert the USRobotics Installation CD-ROM into your CD-ROM drive. OR If a driver CD was not provided or the driver was downloaded from www.usr.com , browse to the folder where…

[Page 11] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Installation Instructions — 5 8. The PWR LED on the modem will light. Congratulations. You have successfully completed the installation procedure. Please register your 56K USB Modem at www.usr.com/productreg/ . Windows 20…

[Page 12] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Installation Instructions — 6 3. Double click USRobotics 56K USB Modem.pkg to launch the installer, and follow the on-screen instructions. 4. Go to Apple > System Preferences > Network. If prompted, click OK. 5. Selec…

[Page 13] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 7 Command Reference How to Use These Commands USRobotics’ AT command set for controller-based modems consists of commands based on data, FAX, and voice communications. The commands presented in this ma…

[Page 14] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 8 result code.

[Page 15] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 9 Sample Command E<value>—Command Echo Use this command to instruct the modem to echo characters sent to it. When the echo feature is selected, characters sent to the modem are sent back to the h…

[Page 16] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 10 S Register Conventions S registers contain parameters used by the modem. The presentation format for an S register is very similar to the format used for an AT command. Each S register has a standard …

[Page 17] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 11 Synchronous Mode and V.80 AT Commands USRobotics’ controller-based modem AT command set supports synchronous command mode and most of the commands defined in ITU-T Recommendation V.80, which defines…

[Page 18] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 12 escape sequence character. A/—Repeat Last Command Use this command to repeat the last AT command. The modem repeats the command currently in the command buffer. Do not use the AT prefix with this co…

[Page 19] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 13 C<value>—Carrier Control Controller-based modems support this command to ensure backwards compatibility with communication software that issues the C1 command. However controller-based modems …

[Page 20] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 14 E<value>—Echo Command Use this command to enable or disable the modem’s echo feature. When the echo feature is selected and the modem is in command mode, characters sent to the modem are sen…

[Page 21] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 15 H<value>—Hook Control This command 1 instructs the modem to go on-hook to disconnect a call or go off-hook to make the telephone line busy. Result codes: • OK if <value> = 0—1. •…

[Page 22] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 16 5 Final Receive Carrier Rate 49333 6 Protocol Negotiation Result LAPM 7 Data Compression Result V42bis 8 Estimated Noise Level 152 9 Receive Signal Poser Level (–dBm) 25 10 Transmit Signal Power Leve…

[Page 23] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 17 L<value>—Speaker Volume Use this command to set the speaker volume setting when the speaker is on. Result codes: • OK if <value> = 0—3. • ERROR if <value> ≠ 0—3. Receiv…

[Page 24] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 18 M<value>—Speaker Control Use this command to turn the speaker on and off. Result codes: • OK if <value> = 0—3. • ERROR if <value> ≠ 0—3. Note: ITU-T Recommendation V.25…

[Page 25] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 19 * See +++ Escape Sequence section on page 11. P—Select Pulse Dialing Use this command to configure the modem for pulse dialing. All subsequent D<dial_string> commands use pulse dialing until e…

[Page 26] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 20 S<register number>=<value>—S Register Control Use this command to view or change an S-register. S-registers contain parameters used by the modem. This command has two forms, one to show …

[Page 27] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 21 W<value>—Result Code Option Use this command to select the modems CONNECT message options. Result codes: • OK if <value> = 0—2. • ERROR if <value> ≠ 0—2. X<value>…

[Page 28] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 22 Y<value>—Long-Space Disconnect Use this command to disconnect the modem from a call upon receiving a long-space signal from the distant end. This command is only valid in 1200 bits/s and 2400 …

[Page 29] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 23 Z<value>—Reset and Recall Stored Profile Use this command to make the modem go on-hook and restore the profile saved by the last &W command. Note: Both Z0 and Z1 restore the same profile …

[Page 30] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 24 &D<value>—Data Terminal Ready (DTR) Control Use this command to select the modem’s response to the data terminal ready (DTR) signal. The host system generates the DTR signal and supplies…

[Page 31] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 25 &J<value>—Auxiliary Relay Option This command is supported to ensure backward compatibility with communications software that issues the J0 command. The J1 version of this command is not s…

[Page 32] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 26 &P<value>—Pulse Dial Make-to-Break Ratio Selection Use this command to select the make-to-break ratio. This command is effective only for Japan. Result codes: • OK if <value> = 0—…

[Page 33] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 27 &T<value>—Self-Test Commands Use this command to perform diagnostic tests on the modem. Each test is designed to isolate a problem location when experiencing periodic data loss or random e…

[Page 34] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 28 Blind Dial Pause 2 sec S6 NoAnswer Timeout 50 sec S7 «,» Pause Time 2 sec S8 Press any key to continue; ESC to quit. Option Selection AT Cmd No Carrier Disc 2000 msec S10 DTMF Dial Speed 95 m…

[Page 35] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 29 &Z<location>=<stored_number>—Store Telephone Number Use this command to store a dialing string. Controller-based modems can save four dialing sting. The format for the command is &am…

[Page 36] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 30 \J<value>—Adjust Bits/s Rate Control Use this command to specify whether or not the negotiated connect speed of the modem forces the adjustment of the speed of the DTE to the modem’s speed. …

[Page 37] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 31 In the third case, the modem receives a break from a remote modem during a connection. These commands are shown in Table 43. \N<value>—Select Error Control Mode Use this command to select the …

[Page 38] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 32 \R<value>—Ring Indicator Signal Off After Answer This command is supported to ensure backward compatibility with communications software that issues the \R0 command. The \R1 version of this co…

[Page 39] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 33 \X<value>—XON/XOFF Pass Through Use this command to restrict the XON/XOFF flow control to the local DCE for processing or have the local DCE send the flow control characters to the remote DCE….

[Page 40] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 34 %B—View Numbers in Blacklist When the blacklisting option is active, use this command to display the telephone numbers and status of any failed or troubled calls. The blacklisting option is associat…

[Page 41] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 35 %E<value>—Auto Fallback/Fallforward Control This command provides the option for the modem to automatically monitor line quality, to fall back when line quality is insufficient, and to fall fo…

[Page 42] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 36 +A8E Extended Syntax Commands +A8T=<signal>,<1st message>,<2nd message>,<sig en>,<msg en>,<supp delay>—Send V.8bis Signal and/or Message Use this command to send …

[Page 43] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 37 +DCS=<v42bis>,<v44>—Select Data Compression Algorithm Use this command to configure the available compression algorithms. The <v42bis> parameter enables or disables the V.42bis, an…

[Page 44] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 38 +DR<value>—Data Compression Reporting Use this command to enable or disable the compression report. If the compression report is enabled, the +DR:<type> intermediate result code reports …

[Page 45] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 39 * ITU-T Recommendation V.250 (05/99) standardized this command. The standard command includes two additional parameter val- ues (1 and 2), which are not supported by the controller-based AT command set…

[Page 46] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 40 The <max_string_tx> parameter specifies the maximum string length to negotiate in the transmit direction. The <max_string_rx> parameter specifies the maximum string length to negotiate in …

[Page 47] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 41 • ERROR if <break_selection> ≠ 0—3 or <timed> ≠ 0 or <default_length> ≠ 10—90 in increments of 10. +EFCS=<value>—32-bit Frame Check Sequence Use this command to co…

[Page 48] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 42 +ES=<orig_rqst>,<orig_fbk>,<ans_fbk>—Error Control Selection Use this command to select the error correction mode. If the modem is operated in V.80 mode (synchronous buffered mode)…

[Page 49] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 43 +ESA=<trans_idle>,<frame_idle>,<framed_un_ov>,<hd_auto>,<crc_type>,<nrz i_en>,<syn1>—Set Up Error Control Parameters Use this command to set the control para…

[Page 50] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 44 +ETBM=<pending_TD>,<pending_RD>,<timer>—Call Termination Buffer Manage- ment Use this command to set the behavior of the modem upon call termination. Only +ETBM=0,0,0 * is a valid …

[Page 51] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 45 +GCAP—Request Complete Capabilities List Use this command to display the modems supported capabilities. The +GCAP command is an action command that always generates an OK result code and does not ha…

[Page 52] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 46 +GMM—Modem Identification Use this command to display the modem identity string and driver version number. The modem returns the same result codes as those generated by the I0 or I3 commands. Resul…

[Page 53] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 47 +ILRR=<value>—DTE-DCE Local Rate Reporting Use this command to display or hide the local rate report result code. If the rate report is enabled, the reported <rate> is the current DTE-DC…

[Page 54] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 48 +ITF=<off>,<on>—Transmit Flow-Control Threshold Use this command to set the flow-control thresholds. The <off> parameter represents the off signal threshold in octets. When this th…

[Page 55] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 49 +MS=<carrier>,<automode>,<min_rate>,<max_rate>,<min_rx_rate>, <max_rx_rate>—Modulation Selection Use this command to set the modem’s modulation, the modulation�…

[Page 56] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 50 The <max_rate> specifies the highest connections rate for the DCE. The <max_rx_rate> specifies the highest receive rate the modem will negotiate. Once a modulation is selected by the +MS co…

[Page 57] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 51 +PCW=<call_waiting>—Call Waiting Enable Use this command to select how the modem responds to a call waiting signal. The controller-based response is also dependent on the current setting of th…

[Page 58] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 52 Result codes: • OK if <value> = 0, 1 • ERROR if <value> ≠ 0, 1 +PMHD<dialing_string>—Modem On-Hold DTMF Dialing Use this command to switch the line while modem on hold is acti…

[Page 59] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 53 during a modem on-hold procedure. In particular, bits 16—19 of the sequence define hold time. The +PMHR command does not have any extended syntax command forms. Result codes: • OK if the modem on-h…

[Page 60] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 54 +PQC=<value>—V.92 Phase 1 and Phase 2 Control Use this command to configure the V.92 short training sequence. This command selects which short phases are used during initiation of a connection…

[Page 61] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 55 +PSS=<value>—Use Short Sequence Use this command to enable or disable the V.92 short training sequence. Result codes: • OK if <value> = 0. • ERROR if <value> ≠ 0. FAX Command…

[Page 62] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 56 +FAP=<sub>,<sep>,<pwd>—Address and Polling Capabilities +FAP=<sub>,<sep>,<pwd> is used by DTE to indicate its capability regarding subaddressing, selective pollin…

[Page 63] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 57 +FBO=<value>—Phase C Data-Bit Order and Phases B and D Data-Bit Order This command is used to by DCE to offer service to convert Phase C and Phase B/D data bit order transparently to the DTE a…

[Page 64] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 58 (wd), page length (ln), data compression format (df), error correction (ec), file transfer mode (bf), scan time/ line (ST), and JPEG for color and black and white (jp). Result codes: • OK if <vr&g…

[Page 65] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 59 +FCI—DCE Reports Received Remote CSI ID A +FCI response from DCE to DTE reports the identification of the called station. The syntax of the response is as follows: +FCI:<CSI ID string>, where…

[Page 66] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 60 +FCO—Facsimile Connection A +FCO response from DCE to DTE indicates a connection with a facsimile station. DCE makes this determination based on detection of HDLC flags in the first received frame, …

[Page 67] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 61 +FCS—DCE Reports the DCS Frame Information A +FCS response from DCE to DTE reports the digital command signal (DCS) frame information. The syntax of the response is as follows: +FCS:<VR>,<B…

[Page 68] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 62 +FDT—Data Transmission Request A +FDT command from DTE requests the DCE to transmit a Phase C page. This command is issued at the beginning of every page. If DCE receives command during Phase B, it …

[Page 69] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 63 20 21 22 23 24 25 26 27 28 Unspecified transmit Phase B error Remote cannot receive or send COMREC error in transmit Phase B COMREC invalid command received RSPREC error DCS sent three times witho…

[Page 70] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 64 +FHR—Report Received HDLC Frame +FHR:<received HDLC frame octets> reports the HDLC data that was sent by the DCE. Result codes: •NA +FHT—Report Transmitted HDLC frame +FHT:<transmitted H…

[Page 71] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 65 +FLO=<value>—Flow Control Selection Use this command to set the type of flow control used to transmit data between the host and the modem. This command can enable hardware or software flow con…

[Page 72] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 66 +FMI?—Manufacturer Identification This command returns: • U.S. Robotics Result codes: • This command always yields an OK result code. +FMM—Product Identification This command returns the produ…

[Page 73] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 67 +FMS=<value>—Minimum Phase C Speed Control Use this command to limit the lowest negotiable speed for a session. The value is the same as the BR parameter in the +FCC valid parameter table. Res…

[Page 74] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 68 +FNR—Negotiation Message Reporting Control Parameter +FNR=<rpr>,<tpr>,<idr>,<nsr> is used to control the reporting of messages generated during Phase B negotiations. Descript…

[Page 75] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 69 +FPA—Selective Polling Address The +FPA:<selective polling address string> is a 20-digit ASCII string in the range from 0x20—0x7E. This string is sent by the DCE at the time specified by the…

[Page 76] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 70 +FPR=<value>—Select FAX Port Rate This command sets the DTE to DCE FAX port rate. The FAX port rate specifies the rate used by the modem and the host system to transmit data between the two de…

[Page 77] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 71 +FPW—Sending or Polling Password The +FPW:<PassWord string> is a 20-digit ASCII string in the range from 0x20—0x7E. This string is sent by the DCE at the time specified by the T.30 Recommend…

[Page 78] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 72 +FRM=<mod>—Receive Data Use the +FRM command to instruct the modem to received data using the modulation defined by Table 160. Result codes: • CONNECT if <mod> = 3, 24, 48, 72—74, 96…

[Page 79] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 73 +FRQ—Receive Quality Threshold This +FRQ=<pgl>,<cbl> command is used to decide if copy quality is OK. This decision is made based on the percentage of good lines (pgl) and the consecutiv…

[Page 80] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 74 +FSA—Destination Subaddress The +FSA:<destination subaddress string> is a 20-digit ASCII string in the range from 0x20—0x7E. This string is sent by the DCE at the time specified by the T.30 …

[Page 81] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 75 +FTI—DCE Reports Received Transmit Station ID (TSI) A +FTI response from DCE to DTE reports the identification of the transmitting facsimile. The syntax of the response is as follows: +FTI: <TSI …

[Page 82] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 76 +FTM=<mod>—Transmit FAX Data with <mod> Carrier +FTM=<mod> command causes the modem to transmit data using the modulation defined by Table 169. Result codes: • CONNECT if <mod&…

[Page 83] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 77 Voice Commands The AT voice command set follows ITU-T Recommendation V.253. The commands are sent through the com port, but the data path is sent either through the com port or through a DMA channel u…

[Page 84] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 78 +VDR=<enable>,<report>—Distinctive Ringing and Cadence Report Use this command to enable or disable the distinctive ringing feature. Distinctive ringing features are identified by the DR…

[Page 85] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 79 +VGR=<gain>—Receive Gain Selection Use this command to set the receive microphone gain control. The receive gain has a range of 0—255. However, the values are only significant between 121 an…

[Page 86] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 80 +VGT=<level>—Speaker Volume Control Use this command to set the speaker volume control. Result codes: • OK if <level> = 0—255. • ERROR if <level> ≠ 0—255. +VIP—Initializ…

[Page 87] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 81 +VNH=<Hook>—Automatic Hang-Up Control Use this command to enable or disable automatic DCE hang-ups in the data and facsimile modes. The +VNH command is part of a group of commands used for cal…

[Page 88] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 82 Voice Commands: Telephone Answering Device (TAD) +VLS=?—Analog Source/Destination Selection and DTMF/Tone Reporting Requests for the modem’s DTMF/tone reporting capabilities are made using this …

[Page 89] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 83 Events Reported to the DTE The modem returns OK when going off-hook in voice mode (+FCLASS=8). After answering in voice mode, the modem may send any of the following <DLE> shielded event codes t…

[Page 90] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 84 +VRA=<interval>—Ringing Tone Goes Away Timer Use this command to set the ringing tone goes away timer before originating a call. The ringing tone goes away timer defines the amount of time the…

[Page 91] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 85 +VSD=<sds>,<sdi>—Silence Detection (QUIET and SILENCE) Use this command to set the silence detection sensitivity (<sds>) and silence detection interval (<sdi>). The <sds&g…

[Page 92] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 86 +VSP=<value>—Speakerphone On/Off Use this command to turn the speakerphone function on and off. Result codes: • OK if <value> = 0, 1. • ERROR if <value> ≠ 0, 1. * ITU-T Recomm…

[Page 93] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 87 +VTR—Start Voice Transmission and Reception Process Use this command to initiate full-duplex voice mode* in the DCE. In this mode, the DTE selects the analog source and sink through the +VLS command…

[Page 94] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 88 +VTX—Enter Voice Transmit Data State Use this command to initiate the voice transmission process with the voice stream sent through the comm port. Applications using the wave interface do not use th…

[Page 95] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 89 #UD—Unimodem Diagnostics This command is defined by Microsoft’s unimodem diagnostics command specification. The modem implements a subset of the parameters in that specification. #UD is an actio…

[Page 96] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 90 Table 204. #UD Last Call Status Report Format Note: Refer to Table 1 in the Microsoft specification. Key Value(s) Required Definition Implemented 0 2 digits Yes Diagnostic command specification revisi…

[Page 97] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 91 34 4 digits 0—FA00 Final transmit carrier rate. X 35 4 digits 0—FA00 Final receive carrier rate. X 36— 3F — — Reserved. — 40 See Table 207 on page 93. 0—2 Protocol negotiation result (s…

[Page 98] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 92 61 2 digits 0—FF Call waiting event count. X 62— 7F — — Reserved for future versions of the specification. — 80-FF — — Reserved for manufacturer proprietary keys. — Table 205. Call Setu…

[Page 99] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 93 F V.pcm (symmetric). — E—7F Reserved (V.58). — 80 X2. — 81 K56flex. X 82 V.FC. — 83 V.32terbo. — 80-FF Reserved for mfgs. — Table 207. errorControl Active from 3.5.2/V.58 Note: Refer to T…

[Page 100] US Robotics 56K SERIAL CONTROLLER FAXMODEM

56K USB Modem User Guide Command Reference — 94 c Table 210. callCleared Codes from 3.6.4/V.58-1994 Note: callCleared indicates that the DCE has gone on-hook and that the previously existing network con- nection has been cleared. These values are h…

Model 5630D

56K

*

 Faxmodem

Specifications & Standards

General

V.92, V.90, V.34, V.32bis, V.32, V.22bis, V.22, V.23, and V.21

V.42/MNP 2-4 error correction, V.42 bis/MNP 5 compression

V.80 video conferencing support

Fax: EIA 578 (Class 1) and EIA 592 (Class 2.0) with V.17, V.29,

V.27ter

Physical

4 LEDs (Rx, Tx, CD, Power)

DTE Interface: RS232/V.24 — DB25 female connector

Phone Line Interface: One RJ-11 socket

Power Supply: 9Vac 1A

Power Switch

Environmental

Temperature: 

Operating Temperature conditions: 0 to 50 degrees

C, Non-Operating Temperature conditions: -20 to 70 degrees C

Humidity: 

Operating Humidity conditions: 20% to 80% non-

condensing, Non-Operating Humidity conditions: 5% to 95%

non-condensing

Regulatory

CE approved (Class B)

Package Dimensions/Weight

9.57 x 7.36 x 3.625 in. (24.3 x 18.7 x 9.2 cm)

0.44 lb (0.2 kg)

Product Dimensions

6.0 x 4.5 x 1.375 in. (15.24 x 11.43 x 3.49 cm)

Minimum System Requirements

PC with 486DX or Pentium processor or equivalent

Available serial port

Microsoft Windows 95 or later Windows operating system (required

for software)

Analogue phone line

Package Contents

USRobotics 56K Faxmodem

Power supply unit

Telephone lead

Serial cable

Quick Install Guide

USRobotics Installation Essentials CD with modem device drivers,

data/fax software, ControlCenter, ICN, and manuals

Internet/online service provider trial software

Warranty

2-year limited manufacturer warranty from date of  purchase

* Capable of  receiving at up to 56 Kbps and sending at up to 48 Kbps (or 31.2 Kbps with V.90 server). Due to FCC 

regulations on power output, receiving speeds are limited to 53.3 Kbps. Actual speeds may vary. V.92 and V.90 features 

require compatible phone service and support from your Internet Service Provider (ISP). USRobotics modems featuring 

V.92 enhancements are backward compatible and will negotiate the highest possible speed when connecting to an ISP.

† Call Waiting service required for using Internet Call Notification (ICN) and Modem on Hold. Call Waiting/Caller ID 

service required for utilizing Caller ID feature of  ICN.

For connection to the Public Switched Telephone Network (PSTN)

Easily connect your computer’s 

USB port to a serial modem with 

a USR5700 Serial-to-USB Cable

RoHS

2002/95/EC