Manuals and User Guides for Tuttnauer 5075. We have 7 Tuttnauer 5075 manuals available for free PDF download: Technician Manual, Operation And Maintenance Manual, Operation & Maintenance Manual, Installation, Operation & Maintenance Manual
Tuttnauer 5075 Technician Manual (134 pages)
Laboratory Vertical Steam Sterilizers ELV, ELVC, ELVPRC
Brand: Tuttnauer
|
Category: Laboratory Equipment
|
Size: 2.78 MB
Table of Contents
-
Table of Contents
3
-
1 Introduction
6
-
2 Symbol Description
6
-
3 Insta Llation Instructions
7
-
Installation Site
8
-
Connection of the Pressure Regulator
8
-
Rear View Model 2540
9
-
Rear View Models 3150, 3170
10
-
Rear View Models 3850, 3870
11
-
Rear View Models 5050, 5075
12
-
-
4 Tests
13
-
Installation Tests
13
-
Periodical Tests
13
-
-
5 Water Quality
14
-
Water for Generating Steam
14
-
Water for the Vacuum Pump and Drain Cooling
14
-
Reverse Osmosis
14
-
-
6 Description of the Control System
15
-
Digital Board DIG — T2
15
-
Control System Block-Diagram
15
-
DIG- T2 Board
16
-
Analog Board ANL-T2
17
-
-
ANL — T2 Board
17
-
AC — Board — AC-T1
18
-
-
AC-T1 Board
18
-
-
7 Calibration of Temperature and Pressure
19
-
Method of Calibration
19
-
Temperature Calibration Procedure
20
-
Pressure Calibration Procedure
22
-
-
8 Test Points
23
-
9 Software Programming Procedures
24
-
General
24
-
Changing Cycle Parameters
24
-
Resetting the Autoclave
32
-
Test Mode
32
-
-
10 Replacing Elements
33
-
Safety Tests after Repair
33
-
Replacing the Circuit Breaker
34
-
Replacing the Safety Valve
35
-
Replacing the Door Gasket
36
-
Replacing the Electronics Board (Control Panel)
37
-
Replacing the Electronics Box
38
-
Cut-Out Thermostat
41
-
Replacing Heating Elements
42
-
Safety Door Locking System for Models 2540, 3150, 3170, 3850, 3870
43
-
Safety Door Locking System for Models 5050, 5075
45
-
Disassembling and Assembling the Door Cover, Models 2540, 3150, 3170
46
-
Disassembling and Assembling the Door Cover, Models 5050, 5075
48
-
Replacing the Locking Microswitch (Models 5050, 5075)
51
-
Replacing the Safety-Opening Valve (Models 5050, 5075)
52
-
Replacing the «DOOR CLOSED» Microswitch (Models 5050, 5075)
53
-
Replacing the Solenoid Lock (Models 5050, 5075)
54
-
10.17 Cleaning and Replacing the Water Level Electrodes
55
-
10.18 Replacing the Printer
56
-
Replacing the Door Switch (Models 2540, 3150, 3170, 3850, 3870)
58
-
Replacing the Locking Device (Models 2540, 3150, 3170, 3850, 3870)
59
-
10.21 Replacing the Plunger or Coil of the BACCARA Solenoid Valve
60
-
-
11 In-Out Test
61
-
12 Troubleshooting
62
-
Displayed Messages and Reference to Trouble Shooting
62
-
Pre-Process Malfunction
63
-
In Process Malfunction
69
-
Mechanical Malfunction
88
-
-
13 List of Spare Parts
89
-
Vessel Assembly Models 2540, 3150, 3170, 3850, 3870
94
-
Vessel Assembly Models 5050, 5075
95
-
Door Tightening Bolt — Assembly
96
-
Door Locking System
97
-
Water Outlet Strainer
98
-
-
14 Pressure Vs Temperature for Saturated Steam
99
-
15 XPCS Manual
103
-
16 Valves Numbering
116
-
Piping Drawing: 2540 ELV &, ELVPRC
118
-
Piping Drawing: 2540 ELVC
119
-
Piping Drawing: 3150, 3170, 3850, 3870 ELV & ELVPRC
120
-
Piping Drawing: 3150, 3170, 3850, 3870 ELVC
121
-
Piping Drawing: 5050, 5075 ELV & ELVPRC
122
-
Piping Drawing: 5050, 5075 ELVC
123
-
Electrical Wiring Diagram for Autoclave Model 2540 ELV
124
-
Electrical Wiring Diagram for Autoclave Models 3150/3170 ELV
125
-
Electrical Wiring Diagram for Autoclave Models 3850/3870 ELV 3X400V
126
-
Electrical Wiring Diagram for Autoclave Models 3850/3870 ELV 3X230V
127
-
Electrical Wiring Diagram for Autoclave Models 3850/3870 ELV 3X208V
128
-
Electrical Wiring Diagram for Autoclave Models 5050/5070 ELV 3X400V
129
-
Electrical Wiring Diagram for Autoclave Models 5050/5070 ELV 3X230V
130
-
Electrical Wiring Diagram for Autoclave Models 5050/5070 ELV 3X208V
131
-
Switch Box Wiring Diagram
132
-
Open Switch Box
133
-
Closed Switch Box
134
-
Advertisement
Tuttnauer 5075 Operation And Maintenance Manual (95 pages)
Electronic Laboratory Autoclaves
Brand: Tuttnauer
|
Category: Laboratory Equipment
|
Size: 8.41 MB
Table of Contents
-
Table of Contents
3
-
General
6
-
Incoming Inspection
6
-
Warranty
6
-
Warranty Statement
6
-
Accessories
7
-
Introduction
7
-
Safety Instructions
10
-
Technical Data
12
-
Operating Conditions
12
-
Directives and Standards
12
-
Environmental Emission Information
13
-
Electrical Data
13
-
Water Quality
14
-
Specifications
15
-
Construction
16
-
Utilities
16
-
Stickers Description
18
-
Front View
19
-
Front View (WR Configuration, Inside Reservoir, Only Specific Items Are Shown)
20
-
Rear View
21
-
Rear View (WR Configuration, Inside Reservoir, Only Specific Items Are Shown)
22
-
Overall Dimensions — Model 5050ELV (MM)
23
-
Overall Dimensions — Model 5075ELV
24
-
Overall Dimensions — Model 5075ELV WR Configuration
24
-
Safety Features Include Built-In Safety Features such as
25
-
Description of Operation
25
-
Control Panel
27
-
Control Panel Drawing
27
-
Description and Functions of the Front Panel Keyboard
28
-
Displayed Error Messages / Symbols
30
-
Displayed Operational Messages / Symbols
30
-
Sterilization Programs
32
-
Program 1: Glass
35
-
Program 2: Plastic
36
-
Program 3: Liquid a
37
-
Program 4: Liquid B — Waste
38
-
Program 5: Liquid a — Cooling (C — Cooling Models Only)
39
-
Program 6: Liquid B — Waste Cooling (C — Cooling Models Only)
40
-
Program 7: Bio Hazard 1 (BH, Bio-Hazard Models Only)
41
-
Program 8: Bio Hazard 2 (BH, Bio-Hazard Models Only)
42
-
Program 9: Bio Hazard Liquids (BH, Bio-Hazard Models Only)
43
-
Program 10: Vacuum Test (PV, Pre-Vacuum Models Only)
45
-
Program 11: Warm-Up
46
-
Program 12: Isothermal
47
-
Program 13: Air Mixture
48
-
Program 14: Glass Test
49
-
Program 15: Durham
50
-
Checking and Changing Parameters and Other Data
52
-
Browsing through the Menus
52
-
Changing a Parameter
53
-
Quick Options Screen
55
-
Logging in and Entering the Main Menu
59
-
Changing Parameters
60
-
System Parameters
61
-
Maintenance
62
-
Cycle Parameters
63
-
Screens
65
-
Screens Following a Complete Successfully Cycle — «Cycle Ended
65
-
Screens Following Aborted Cycles after Complete Sterilization Stage
65
-
Screens Following a Fail Cycle
66
-
Printer
68
-
Printer Output
68
-
Printer Handling
70
-
Preparation before Sterilization
73
-
Instruments
73
-
Liquids
74
-
Loading
74
-
Operation
75
-
Draining and Filling the Water Reservoir (WR Only)
75
-
Turning on the Autoclave
76
-
Opening the Door — MD Models (Mechanical Door)
77
-
Opening the Door — D Models (Automatic Door)
77
-
Loading
78
-
Selecting Program
79
-
Closing and Locking the Door — MD Models (Mechanical Door)
79
-
Closing and Locking the Door — D Models (Automatic Door)
79
-
Starting a Cycle
81
-
Unloading
81
-
Stopping the Process and Cancelling the ERROR Message
81
-
Start Cycle by Clock Mode
82
-
Moving the Autoclave
82
-
Loading and Unloading the Device
82
-
Service and Maintenance
84
-
Preventive Maintenance
84
-
Replacing the Safety Valve — PED Type
85
-
Replacing the Safety Valve — ASME Approved Type
87
-
Checking the Safety Valve
87
-
Troubleshooting
89
-
Baskets and Containers
94
-
Spare Parts List
95
-
Accessories
95
Tuttnauer 5075 Operation & Maintenance Manual (87 pages)
Laboratory Vertical Steam Sterilizers
Brand: Tuttnauer
|
Category: Steriliser
|
Size: 5.71 MB
Table of Contents
-
Table of Contents
3
-
General
7
-
Introduction
7
-
Incoming Inspection
8
-
Warranty
8
-
Warranty Statement
9
-
-
Safety Instructions
10
-
Technical Data
12
-
Stand — by Heating Mode
12
-
Storage Conditions
12
-
Operating Conditions
12
-
Utilities
12
-
Construction
13
-
Environment Emission Information
13
-
Directives and Standards
13
-
Electrical Data
14
-
Overall Dimensions Models 5050, 5075 el
15
-
Symbol Description
16
-
Water Quality
17
-
Safety Features
18
-
-
Control Panel
21
-
Control Panel Drawing
21
-
Description and Functions of the Front Panel Keyboard
22
-
Displayed Error Messages / Symbols
24
-
Displayed Operational Messages / Symbols
24
-
Description of Operation
25
-
Leakage Test
26
-
Exhaust
26
-
Drying (PV — Pre-Vacuum Nodel Only)
26
-
Vacuum Test Program (PV — Pre-Vacuum Model Only)
26
-
-
Sterilization Programs
27
-
Program 1: Glass
29
-
Program 2: Plastic
30
-
Program 3: Liquid a
31
-
Program 4: Liquid B — Waste
32
-
Program 5: Liquid a — Cooling (ELC — Cooling Models Only)
33
-
Program 6: Liquid B — Waste Cooling (ELC — Cooling Models Only)
34
-
Program 7: Waste
35
-
Program 8: Hollow Load
36
-
Program 9: Vacuum Test (PV, Pre-Vacuum Model Only)
37
-
Program 10: Bio Hazard Liquid Cooling (BH, Bio-Hazard Models Only)
38
-
Program 11: Bio Hazard Liquid (BH, Bio-Hazard Models Only)
39
-
Program 12: Bio Hazard (BH, Bio-Hazard Models Only)
40
-
Program 13: Warm-Up
41
-
Program 14: Isothermal
42
-
-
Checking and Changing Parameters and Other Data
43
-
Directories and Subdirectories
43
-
Entering the Main Menu
43
-
System Parameters
45
-
History
47
-
Maintenance
49
-
Advanced Options
53
-
Version Information
56
-
-
Screens
59
-
Screens Following a Completely Successful Cycle — «Cycle Ended
59
-
Screens Following Aborted Cycles after Complete Sterilization Stage
60
-
Screens Following a Fail Cycle
60
-
-
Printer
62
-
Printer Output
62
-
Printer Handling
64
-
Treating the Thermal Papers
66
-
-
Preparation before Sterilization
67
-
Instruments
67
-
Liquids
68
-
Tubing
69
-
Loading
69
-
-
10 Operating Instructions
70
-
Turning on the Autoclave
70
-
Opening the Door
70
-
Safety
71
-
Loading
71
-
Selecting the Program
71
-
Closing the Door
71
-
Starting Cycle
71
-
Unloading
73
-
Stopping the Process and Cancelling the ERROR Message
73
-
10.10 Start Cycle by Clock Mode
74
-
-
11 Service and Maintenance Instructions
75
-
Preventive and Scheduled Maintenance
75
-
Checking the Safety Valve
76
-
Moving the Autoclave
81
-
-
12 Troubleshooting
82
-
13 Baskets and Containers
86
-
Spare Parts List — 5075
87
-
15 Accesories List
87
Advertisement
Tuttnauer 5075 Operation & Maintenance Manual (85 pages)
Laboratory Vertical Steam Sterilizers
Brand: Tuttnauer
|
Category: Laboratory Equipment
|
Size: 1.85 MB
Table of Contents
-
Table of Contents
3
-
General
6
-
Incoming Inspection
6
-
Warranty
6
-
Warranty Statement
6
-
Accessories
7
-
Safety Instructions
8
-
Technical Data
10
-
Introduction
10
-
Operating Conditions
11
-
Directives and Standards
11
-
Environment Emission Information
12
-
Electrical Data
12
-
Specifications
12
-
Construction
12
-
Loading Capacities
13
-
Utilities
13
-
Symbol Description
14
-
Front View
15
-
Rear View
16
-
OVERALL DIMENSIONS DRAWING (MM)
17
-
Water Quality
18
-
Safety Features
19
-
Description of Operation
20
-
Control Panel
21
-
Control Panel Drawing
21
-
Description and Functions of the Front Panel Keyboard
22
-
Displayed Error Messages / Symbols
24
-
Displayed Operational Messages / Symbols
25
-
Sterilization Programs
26
-
Program 1: Unwrapped Instruments
27
-
Program 2: Wrapped Instruments
28
-
Program 3: Unwrapped Pouches
29
-
Program 4: Wrapped Pouches
30
-
Program 5: Unwrapped Delicate Instruments
31
-
Program 6: Wrapped Delicate Instruments
32
-
Program 7: Custom 1
33
-
Program 8: Custom 2
34
-
Program 9: Liquid a
35
-
Program 10: Liquid B
36
-
Checking and Changing Parameters and Other Data
37
-
Directories and Subdirectories
37
-
Table of Parameters
38
-
Entering the Main Menu
39
-
Cycle Parameters (Custom 1)
41
-
System Parameters
47
-
History
50
-
Maintenance
52
-
Advanced Options
57
-
Version Information
60
-
Screens
63
-
Screens Following a Complete Successfully Cycle — «Cycle Ended
63
-
Screens Following Aborted Cycles after Complete Sterilization Stage
64
-
Screens Following a Fail Cycle
65
-
Printer
66
-
Printer Output
66
-
Printer Handling
68
-
Preparation before Sterilization
71
-
Instruments
71
-
Liquids
72
-
Loading
72
-
Operation
73
-
Turning on the Autoclave
73
-
Opening the Door
73
-
Loading
74
-
Selecting Program
74
-
Closing the Door
74
-
Starting Cycle
74
-
Unloading
74
-
Stopping the Process and Cancelling the ERROR Message
75
-
Start Cycle by Clock Mode
75
-
10.10 Moving the Autoclave
75
-
10.11 Loading and Unloading the Device
75
-
Door Safety System
77
-
Pressure Switch and Locking Solenoid
77
-
Service and Maintenance
78
-
Preventive Maintenance
78
-
Checking the Safety Valve
79
-
Troubleshooting
81
-
Baskets and Containers
84
-
Spare Parts List
85
-
Accessories
85
Tuttnauer 5075 Operation & Maintenance Manual (68 pages)
Electronic Table — Top Autoclaves (With cooling option)
Brand: Tuttnauer
|
Category: Laboratory Equipment
|
Size: 1.37 MB
Table of Contents
-
Table of Contents
3
-
1 General
6
-
Incoming Inspection
6
-
Warranty Statement
6
-
-
2 Safety Instructions
8
-
3 General Information
10
-
Stand — by Heating Mode
10
-
Operating Conditions
11
-
Utilities
11
-
Load on Counter
11
-
Construction
11
-
Environment Emission Information
12
-
Directives and Standards
12
-
Electrical Data
12
-
Overall Dimensions Model 2540 el
13
-
Overall Dimensions Models 3150 el
14
-
Overall Dimensions Models 3850, 3870 el
15
-
Overall Dimensions Models 5050, 5075 el
16
-
Loading Capacities
17
-
Symbol Description
17
-
Technical Specifications el
18
-
Water Quality
19
-
-
Front View
21
-
Rear View Model 2540
22
-
Rear View Models 3150, 3850, 3870
23
-
Rear View Models 5050, 5075
24
-
4 Sterilization Programs
25
-
Program 1 — Unwrapped Instruments (1 — Instruments)
25
-
Program 2 (2- Instruments)
26
-
Program 3 (3 -Waste)
27
-
Program 4 (4 — Liquids)
28
-
Program 5 (5- Liquids)
29
-
Program 6 (6 — Liq+Cool)
30
-
-
Front Panel Keyboard
31
-
Description and Functions of the Front Panel Keyboard
32
-
Description of the Display
35
-
Description of Displayed Messages and Safety Measures
37
-
-
5 KEYBOARD (Keys and Display)
31
-
6 Printer
39
-
Printer Operation
39
-
DPU-20 Printer Handling
41
-
DPU 30 Printer Handling
42
-
-
7 Preparation before Sterilization
43
-
Filling the Water Reservoir
46
-
-
8 Operating Instructions
47
-
Operation
47
-
Loading and Unloading the Device
48
-
-
9 Maintenance Instructions
50
-
Preventive and Scheduled Maintenance
50
-
Draining the Reservoir
51
-
Cleaning Water Strainer
52
-
Checking the Safety Valve
53
-
Replacing the Door Gasket
55
-
Door Safety System for Models 2540, 3150, 3850, 3870
56
-
Door Safety System for Models 5050, 5075
57
-
Cleaning Table Top Autoclaves with Chamber Brite
60
-
-
10 Troubleshooting
62
-
Pouch Rack
64
-
Tray — Standard
65
-
Tray, Special ELC Version
66
-
Tray Holder, Special ELC Version
66
-
Baskets and Containers
67
-
11 Spare Parts List
68
-
12 Acssesories List
68
Tuttnauer 5075 Operation & Maintenance Manual (59 pages)
Brand: Tuttnauer
|
Category: Laboratory Equipment
|
Size: 1.56 MB
Table of Contents
-
Table of Contents
3
-
1 General
6
-
Incoming Inspection
6
-
Warranty
6
-
Warranty Statement
6
-
-
2 Safety Instructions
8
-
3 Technical Data
10
-
Introduction
10
-
Stand — by Heating Mode
11
-
Operating Conditions
11
-
Utilities
11
-
Load on Counter
12
-
Construction
12
-
Environment Emission Information
12
-
Directives and Standards
12
-
Electrical Data
13
-
Overall Dimensions Models 5050, 5075 el
14
-
Symbol Description
15
-
Technical Specifications EL-D
16
-
Water Quality
17
-
-
4 Control Panel
21
-
Description and Functions of the Front Panel Keyboard
22
-
Displayed Error Messages / Symbols
24
-
Displayed Operational Messages / Symbols
24
-
-
5 Description of Programs
26
-
Operations Sequence
26
-
Vacuum Test Program (ELPV Model Only)
26
-
-
6 Sterilization Programs
27
-
Program 1: Glass
29
-
Program 2: Plastic
30
-
Program 3: Liquid a
31
-
Program 4: Liquid B — Waste
32
-
Program 5: Vacuum Test (ELPV Model Only)
33
-
-
7 Screens
34
-
Screens Following a Completely Successful Cycle — «Cycle Ended
34
-
Screens Following Aborted Cycles after Complete Sterilization Stage
35
-
Screens Following a Fail Cycle
35
-
-
8 Printer
37
-
Printer Output
37
-
Printer Handling
39
-
Treating the Thermal Papers
41
-
-
9 Preparation before Sterilization
42
-
Instruments
42
-
Tubing
43
-
Sterilization of Liquids
44
-
Filling the Water Reservoir
44
-
-
10 Operating Instructions
45
-
Turning on the Autoclave
45
-
Opening the Door
45
-
Safety
45
-
Loading
46
-
Selecting the Program
46
-
Closing the Door
46
-
Starting Cycle
46
-
Unloading
47
-
Start Cycle by Clock Mode
47
-
-
11 Service and Maintenance Instructions
48
-
Preventive and Scheduled Maintenance
48
-
Draining the Reservoir
49
-
Cleaning Water Strainer
50
-
Checking the Safety Valve
51
-
Moving the Autoclave
54
-
-
12 Troubleshooting
55
-
13 Spare Parts List
59
-
14 Acssesories List
59
Tuttnauer 5075 Installation, Operation & Maintenance Manual (59 pages)
Laboratory Vertical Steam Sterilizers ELV, ELVC, ELVPRC
Brand: Tuttnauer
|
Category: Laboratory Equipment
|
Size: 0.99 MB
Table of Contents
-
Table of Contents
2
-
1 General
5
-
Incoming Inspection
5
-
Warranty
5
-
Warranty Statement
5
-
Ordering Information
6
-
-
2 Safety Instructions
7
-
3 Technical Data
9
-
Introduction
9
-
Operating Conditions
10
-
Directives and Standards
10
-
Environment Emission Information
10
-
Electrical Data
11
-
Specifications
11
-
Loading Capacities
12
-
Utility
12
-
Symbol Description
13
-
-
Overall Dimensions 2540 ELV
14
-
Overall Dimensions Drawing for the 3150 / 3170 ELV
15
-
Overall Dimensions Drawing for the 3850 / 3870 ELV
16
-
Overall Dimensions Drawing for the 5050/ 5075 ELV
17
-
Water Quality
18
-
Safety Features
19
-
Description of Operation
20
-
-
4 Sterilization Programs
21
-
Program 1 — Unwrapped Instruments (1 — Instruments)
21
-
Program 2 (2- Instruments)
22
-
Program 3 (3 -Waste)
23
-
Program 4 — (4 — Liquid)
24
-
Program 5 (5- Liquid)
25
-
Program 6 (6-Liquid + Cool) — Option on ELVC Only
26
-
-
Front Panel Keyboard
27
-
Description and Functions of the Front Panel Keyboard
28
-
Description of the Operational Messages
31
-
Displayed Error Messages and Safety Measures
33
-
-
5 KEYBOARD (Keys and Display)
27
-
6 Printer
35
-
Printer Operation
35
-
DPU-20 Printer Handling
37
-
DPU 30 Printer Handling
38
-
-
7 Preparation before Sterilization
39
-
Instruments
39
-
Tubing
40
-
Liquids
40
-
Loading
40
-
-
8 Operation
41
-
Operating Instructions
41
-
Moving the Autoclave
42
-
Loading and Unloading the Device
42
-
-
9 Door Safety System
44
-
Solenoid Locking Device
44
-
Door Safety System for Models 5050, 5075
44
-
Piston Lifting Device for 3850/3870/5050/5075 ELV
48
-
-
10 Service and Maintenance
49
-
Preventive Maintenance
49
-
Replacing the Air Filter
50
-
Replacing the Door Gasket
51
-
Checking the Safety Valve
51
-
Cleaning Water Outlet Strainer
54
-
-
11 Troubleshooting
55
-
Baskets and Containers
57
-
12 Spare Parts List
59
-
13 Accessories
59
Advertisement
Related Products
-
Tuttnauer 5050
-
Tuttnauer 5075 HSG
-
Tuttnauer 5075 EL
-
Tuttnauer 5075 GS-2A
-
Tuttnauer 50125 GS-2A
-
Tuttnauer 5050 ELV-D
-
Tuttnauer 5075 ELV-D
-
Tuttnauer 5075 EL-MD
-
Tuttnauer 5075 EL-D
-
Tuttnauer 5050 EL
Tuttnauer Categories
Laboratory Equipment
Medical Equipment
Steriliser
Accessories
Cleaning Equipment
More Tuttnauer Manuals
-
LEEC W100
1 USER MANUAL LEEC WARMING CABINET W100, W157 and W330 CONTENTS 1) GENERAL DESCRIPTION 2) INSTALLATION AND SWITCHING ON WARMING CABINET 3) PROGRAMMING TEMPERATURE 4) OVERTEMPERATURE CUT-OUT 5) WARMING CABINET USEAGE 6) CLEANING & DISINFE …
W100 Laboratory Equipment, 8
-
Interacoustics Sera
D-0122934-A – 2019/02 Page 1 of 2 Quick Guide SeraTM Cart Assembly About this quick guide This quick guide provides instructions about how to place and attach the SeraTM and accessories on the cart. Follow the cart manufacturer’s instructions to assemble the cart prior to installing the SeraTM and accessories. …
Sera Measuring Instruments, 2
-
Dynojet Power commander III
i303-411 www.powercommander.com 1998-2003 Suzuki TLR1000 — PCIII USB — 11998-2003 Suzuki TLR1000Installation InstructionsDynojet Research 2191 Mendenhall Drive North Las Vegas, NV 89081 (800) 992-4993 www.powercommander.comParts List1 Power Commander1 USB Cable1 CD-ROM1 Installation Guide1 Power Adapter2 Power …
Power commander III Motorcycle Accessories, 4
-
Barnstead Thermolyne Corporation Lab-Line 4628
(217) 352-9330 | [email protected] | artisantg.com-~ ARTISAN® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment. Artisan Technology Group Full-service, independent repair center with experienced engineers and technicians on staff. We buy your excess, underutilized, and idle equipment along w …
Lab-Line 4628 Laboratory Equipment, 26
-
Thermo Scientific MaxQ 4000
MaxQ 4000 Incubated andRefrigerated ShakersOperating Manual and Parts List 057-287-00 Rev. 1_________________________________________________________________________________Part of Thermo Fisher Scientific …
MaxQ 4000 Laboratory Equipment, 44
-
Gilson ASPEC GX-274
Gilson,Inc. | PO Box 620027 | Middleton, WI 53562-0027 | Tel: 608-836-1551 OR 800-445-7661 | Fax: 608-831-4451GilsonS.A.S. | 19, avenue des Entrepreneurs | BP 145, F-95400 Villiers-le-bel, FRANCEwww.gilson.com | [email protected] | [email protected] | [email protected] Qualication ProceduresGX-27 …
ASPEC GX-274 Laboratory Equipment, 5
-
Julabo HT60-M2
19533727-V1.docx Print date: 13.01.14 Operating Manual High Temperature Circulator HT60-M2 HT60-M3 C.U.-cooling unit 1.953.3727-V1 us 01/14 Forte HT with cooling unit Version: V 4.01-J JULABO USA, Inc. 884 Marcon Boulevard Allentown, PA 18109 Phone: +1(610) 231-0250 Fax: +1(610) 231 …
HT60-M2 Laboratory Equipment, 67
-
TESTO 875i
Brief instructions entesto 875i · Thermal imagerContactGREAT BRITAIN / IRELANDTesto Ltd.Alton, Hampshire GU34 2QJ Tel. (14 20) 54 44 33, Fax (14 20) 54 44 E-mail: [email protected] Inc.Flanders, NJ. 07836Tel. (973) 2 52 17 20, Fax (973) 2 52 17 29E-mail: [email protected] Pty LtdCroydon South VIC 313 …
875i Thermal cameras, 2
В наличии документация на медицинское оборудование фирмы Tuttnauer (в т.ч. на русском языке):
Modification: 06 September 2023
Инструкция по применению и обслуживанию (User and Service manual) на Автоклав Model 4483 1R — EP [Tuttnauer] Стерилизаторы
Эксплуатационная и сервисная документация (Operating and Service Documentation) на Автоклав Model 5596 EP-1 [Tuttnauer] Стерилизаторы
Инструкция по экспл. и обслуживанию (Operating and Service Documentation) на Автоклав Model 5596 SP-1 [Tuttnauer] Стерилизаторы
Эксплуатационная и сервисная документация (Operating and Service Documentation) на Автоклав Model 66120 [Tuttnauer] Стерилизаторы
Эксплуатационная и сервисная документация (Operating and Service Documentation) на Автоклав Model 69150 [Tuttnauer] Диагностика
Эксплуатационная и сервисная документация (Operating and Service Documentation) на Автоклавы модели 1730,2340,2540,3850,3870 серии E, EK, EA & EKA [Tuttnauer] Стерилизаторы
Техническое описание, инструкция по эксплуат. (Technical description, instructions) на Модели 1730,2540,3850,3870,5050,5075 EL [Tuttnauer] Стерилизаторы
Техническое описание, инструкция по эксплуат. (Technical description, instructions) на Модели 2540 3850 3870 5050 5075 ELV [Tuttnauer] Стерилизаторы
Эксплуатационная и сервисная документация (Operating and Service Documentation) на Модели 2540 3850 3870 5050 5075 MLV [Tuttnauer] Стерилизаторы
Архив технической документации медицинского оборудования © 2006 … 2023
В связи с нестабильным курсом валют, цены могут отличаться. Обращайтесь за уточнениями к менеджерам.
- КОД: ЦБ-00012814
-
Артикул:
- Бренд: Tuttnauer
Товар снят с производства
Его сняли с производства и скорее всего у других продавцов
его
больше нет.
Доставка по всей России
- Самовывоз — бесплатно
- В офис или домой — от 250 ₽
- До ПВЗ — от 250 ₽
Условия доставки
Характеристики
Артикул:
Бренд: Tuttnauer
Страна:
Израиль
Описание
Серия автоклавов Tuttnauer ELV D-Line – это современные многофункциональные паровые стерилизаторы с большим количеством настраиваемых параметров и функций, разработаны для покрытия широкого спектра задач лабораторий, исследовательских институтов и биотехнологических учреждений.
ОСОБЕННОСТИ:
- температурный диапазон стерилизации от 105°C до 138°C
- удобная система управления с цветным дисплеем
- до 30 программ стерилизации
- два гибких датчика температуры PT100 внутри камеры обеспечивают контроль температуры стерилизуемых жидкостей, чувствительных к воздействию температур и времени стерилизации
- защитное устройство, предотвращающее открывание крышки автоклава если камера находится под давлением
- защитное устройство, предотвращающее начало цикла стерилизации при условии открытой крышки
- рабочая камера оснащена предохранительным клапаном, позволяющем выпускать избыток давления в случае превышения давления в камере выше установленного значения
- защита встроенного парогенератора: система слежения за уровнем воды поддерживает постоянный уровень воды для безопасной работы нагревательных элементов
- камера автоклава из нержавеющей стали 316L
- высококачественные лабораторные автоклавы Tuttnauer выполнены в соответствии со строгими международными директивами и стандартами
ДОПОЛНИТЕЛЬНЫЕ ОПЦИИ:
- система быстрого охлаждения за счёт контура водяного охлаждения
- вакуумный насос для предвакуумного удаления воздуха и поствакуумного удаления влаги. Для более эффективной сушки используется в комбинации с парогенератором (EL модели)
- независимый встроенный парогенератор
- система контроля процесса стерилизации F0 для чувствительных материалов
- дезинфекционный/изотермический цикл от 60°C до 94°C для мягкого нагрева и охлаждения агаризованных сред
- цикл прогрева при температуре от 95°C до 104°C
- система биологической фильтрации с фильтром 0,2 мкм для очистки выводимого из автоклава воздуха
- встроенный принтер
- внешний независимый самописец
- удалённое управление
- камера автоклава из нержавеющей стали 316Ti вместо стандартной 316L
АКСЕССУАРЫ:
- контейнеры с вентиляционными отверстиями
- корзины для вертикальных автоклавов
- передвижное подъемное устройство для вертикальных автоклавов
- ролики для вертикальных автоклавов
Отзывов пока нет, но ваш может стать первым
о
товаре 5075 ELV D-Line — лабораторный автоклав с вертикальной загрузкой, объём камеры 160 л
Оформление заказа
Оформление заказа
Укажите ваши данные
Запросить аналог товара
Введите поисковый запрос
Описание Лабораторный автоклав вертикальный Tuttnauer 5075 ELV-WR D-line
Лабораторный автоклав вертикальный Tuttnauer 5075 ELV-WR D-line. Новая линейка вертикальных автоклавов Tuttnauer WR со
встроенным резервуаром для обессоленной воды разработана для случаев, когда
отсутствует возможность подключения стерилизатора к воде и дренажной системе.
Вода из резервуара автоматически подается в камеру, а конденсат и отработанная
жидкость после завершения цикла сливаются обратно в резервуар.
Автоклавы D-line оборудованы простой русскоязычной системой
управления, которая полностью соответствует современным требованиям и позволяет
вам успешно решать
Области применения: любые задачи в современной лаборатории. Лабораторный автоклав вертикальный Tuttnauer 5075 ELV-WR D-line купить в Тольятти по приемлемой цене.
Лабораторный автоклав с вертикальной загрузкой
5075 ELV-WR оснащён резервуаров для обессоленной воды, микропроцессорной
панелью управления и камерой объёмом 160 литров,
изготовленной из нержавеющей стали.
Области применения:
— Исследовательские лаборатории;
— Медико-биологические лаборатории;
— Учебные заведения;
— Производство.
Преимущества автоклавов серии EL D-Line:
— Стерилизация жидкости с различными опциями охлаждения;
— Стерилизация пипеток и стекол микроскопа;
— Стерилизация инструментов (обернутых и необернутых);
— Контроль биологической опасности и стерилизация отходов;
— Приготовление агара;
— Лабораторные автоклавы оснащены рядом независимых механических
и цифровых средств защиты. Защитное устройство не позволяет оператору открыть
дверцу, пока камера находится под давлением. При открытой дверце пар в камеру
не попадает.
Если дверца открыта или не заблокирована надлежащим образом,
цикл не запускается.
Дверца не может быть разблокирована до тех пор, пока
температура жидкости не достигнет предварительно установленной конечной
температуры. Дверца не может быть разблокирована до тех пор, пока давление в
камере не достигнет комнатного давления;
— Двойной независимый контроль – это сочетание электронного
и механического контроля, который обеспечивает оператора двумя независимыми
средствами контроля давления;
— Камера оснащена предохранительными клапанами: если
давление превышает допустимое предельное значение, предохранительные клапаны
будут разгружены.
Особенности 5075 ELV-WR D-line:
— Продвинутая система управления. Информация о 200 последних
циклах автоклавирования хранится во встроенной памяти; есть два температурных
сенсора; есть возможность удаленного мониторинга с ПК;
— Автоматический замок двери;
— Цветной дисплей;
— Русскоязычное меню;
— До 10 фиксированных программ стерилизации;
— До 20 настраиваемых программ стерилизации;
— Два погружных температурных датчика, которые обеспечивают
контроль температуры стерилизуемой жидкости, что особенно важно при
стерилизации растворов, чувствительных к температурному режиму (например,
микробиологических сред);
— USB-порт для передачи данных.
Максимальная загрузка колб Эрленмайера или флаконов
с винтовой крышкой в автоклаве 5075 ELV-WR:
Объём колб или |
250 |
500 |
1000 |
2000 |
3000 |
5000 |
Количество колб |
3×21 |
3×14 |
3×8 |
2×5 |
2×4 |
1×2 |
Количество флаконов |
3×32 |
3×21 |
3×15 |
2×8 |
— |
2×4 |
Дополнительные опции:
— Встроенный принтер EL-D/ELV-D/ELV-WR/EL;
— Ролики для вертикальных автоклавов;
— Независимое записывающее устройство для автоклавов
Tuttnauer;
— Дополнительный температурный датчик PT100 для автоклавов
Tuttnauer;
— Распределительная коробка для автоклавов Tuttnauer серии
D-Line;
— Передвижное подъемное устройство для вертикальных
автоклавов;
— Микробиологический фильтр для биол. опасных
материалов BH для настольных автоклавов Tuttnauer;
— Камера из нержавеющей стали 316 Ti для настольных
автоклавов Tuttnauer;
— Программа R.PC.R для создания отчетов на ПК;
— Защита информации 21 CFR part 11;
— Пакет валидационных протоколов IQ/OQ/PQ;
— Загрузочные корзины из нержавеющей стали для вертильных
автоклавов Tuttnauer серии D-Line;
— Загрузочные контейнеры из нержавеющей стали для
вертикальных автоклавов Tuttnauer серии D-Line.
Технические характеристики 5075 ELV-WR D-line:
— Полезный объем камеры – 160 л;
— Диаметр/глубина камеры – 500×750 мм;
— Габариты, Д×В×Ш – 770×1090×770 мм;
— Вес – 171
кг;
— Расход воды на цикл – 20 л;
— В/Мощность – 208/230/380-400, 9 кВт.