3.568.5275.400
Electropneumatic Smart Positioner
IM-P343-37
CH Issue 3
Printed in Italy
SP400
5. Installation
7. Gyorsbeállítási folyamat
8. Programozási
folyamatábra
9. Programozás és
beüzemelés
11. Default values and
program settings
12. Glossary of
display data
IM-P343-37
CH Issue 3
1
© Copyright 2011
Related Manuals for Spirax Sarco SP400
Summary of Contents for Spirax Sarco SP400
-
Page 1
3.568.5275.400 IM-P343-37 CH Issue 3 SP400 Electropneumatic Smart Positioner Installation and Maintenance Instructions 1. Index 2. Safety information 3. Technical information 4. Options 5. Installation 6. Electrical connections 7. Gyorsbeállítási folyamat 8. Programozási folyamatábra 9. Programozás és beüzemelés 10. Maintenance 11. -
Page 2
Programmable functions 4. Options Pressure gauge block Mounting the SP400 positioner — General informaton Sequence for mounting an SP400 positioner to 5. Installation a linear actuator Sequence for mounting an SP400 positioner to a rotary actuator Air supply and connections… -
Page 3
IP65 (see BS EN 60534-1 1998). 2.2 Electrical safety requirements The SP400 is a class III product which must only be powered from Safe Extra Low Voltage (SELV) sources whether by virtue of a 4 — 20 mA control signal or from a separate power supply. -
Page 4
3. Technical information 3.1 Description The SP400 smart valve positioner is loop powered from a 4 — 20 mA input signal to provide accurate adaptive positional control of pneumatic actuated linear and quarter turn valves. Precise control is maintained through valve position feedback that automatically varies the pneumatic output pressure to overcome the effects of stem friction and flow forces to maintain desired valve position. -
Page 5
No. Features indicates all is OK ! Indicates a delay in positioning, this disappears when the position is reached Indicates that the value displayed is a percentage Indicates that the value displayed is the input current measured in mA Indicates that the value displayed is a time measured in seconds Indicates that you’re accessing the main programming menus… -
Page 6
3.3 Materials Part Material Finish Case and cover Die cast aluminium Anti-corrosive paint to RAL5010 Magnet bracket Die cast aluminium 3.4 Programmable functions Autostroke Automatic commissioning routine Valve type 2-port or 3-port Selectable 0 to 100% or 100% to 0% % travel depending on valve / actuator configuration Control action… -
Page 7
4. Options 4.1 Pressure gauge block An optional pressure gauge block (Figure 3) can be fitted onto the SP400 positioner which includes two pressure gauges indicating air supply pressure and output air signal pressure to the actuator. The pressure gauge block can be retrospectively fitted using 2 off M5 socket head screws. -
Page 8
VDI / VDE 3845 compliant mounting kit for rotary actuators. 5.1.2 The SP400 has an enclosure rating of IP65 and should be installed in a location that will not exceed its ambient temperature limits of -10°C minimum and +80°C maximum. -
Page 9
5.2 Sequence for mounting an SP400 positioner to a linear actuator Fig. 4 Pillar mounting kit for a linear actuator 5.2.1 Loosely attach the magnet bracket (2) to the valve / actuator connector (refer to Figures 4 and 5). Be sure it is positioned horizontally (as shown in Figure 5). -
Page 10
PN1000 Fig. 7 Bracket markings 5.2.3 If you’re not using a Spirax Sarco actuator, slide the bracket till the distance ‘A’ between the center of the magnet and the inner side of the mounting plate is 25 mm (Figure 8). -
Page 11
Fig. 9 Pillar actuator assembly Mounting plate Assembled Yoke actuator Fig.10 Yoke actuator assembly 5.2.5 Locate the protection plate onto the back of the SP400 positioner housing and fix in place (Figures 11 and 12). Protection plate Assembled Fig. 11 Fig. -
Page 12
5.2.6 5.2.7 Attach the positioner mounting plate to the Adjust the vertical position of the SP400 positioner as shown in Figures 26 and 27. positioner and mounting plate assembly, by sliding it up or down on the pillar style actuators,… -
Page 13
5.3 Sequence for mounting an SP400 positioner to a rotary actuator 5.3.1 Assembly for fitting an SP400 on to a ¼ turn valve. Fig. 17 Mounting kit IM-P343-37 CH Issue 3… -
Page 14
Fig. 19 Fig. 18 Fig. 20 IM-P343-37 CH Issue 3… -
Page 15
Fig. 21 Assembled Fig. 22 IM-P343-37 CH Issue 3… -
Page 16
5.3.2 Adjust the magnet orientation as illustrated in Figures 23 and 24 and tighten the bolt to fix the magnet into position. There should be a distance of between 5 and 14 mm between the magnet and the positioner. Refer to Figure 23 for actuator with clockwise rotation. Refer to Figure 24 for actuator with anti-clockwise rotation. -
Page 17
/ regulator is fitted in the mains air supply to the positioner. The filter / regulator should have a coalescing filter such as a Spirax Sarco type MPC2, or suitable compressed air pipework is used. -
Page 18
Systems: Installation design and practice or local equivalent. 6.2 Wiring diagrams 6.2.1 Terminal block MENU MANUAL AUTOS AUTOMATIC TUNE AUTOSTROKE keep pressed SP400 Fig. 26 Pole Description Not used 4-20 mA current signal input Mainboard Not used Not used Not used… -
Page 19
6.2.2 Single loop applications The SP400 is loop powered using the 4 — 20 mA input signal source providing a minimum signal of 3.6 mA can be maintained. Minimum current 3.6 mA Maximum current 30 mA Maximum voltage drop < 7 V… -
Page 20
7. Gyors beállítási funkció 2-utú szelep Akövetkező leírás a 2 utú szelepeknél használható melyhez pneumatikus működtetőt szereltek direct működésú és a vezérlőjele 4-20 mA kivétel ha egyébb különleges beállítást igényel. Megjegyzés:: A PN5000 és PN6100 sotrozathoz egyéb beállítások is szükségesek. (lásd a 9.5.2). -
Page 21
(with travel setting (TRAVL) 0 — 100%, refer to Figures 14 and 15) Proceed as above up to Section 7.1.8. 7.2.1 On completion of a successful autostroke press and hold the key for 3 seconds to access the SP400 MENU. 7.2.2 key three times to access SET. Press the 7.2.3 Press the key once to advance to VALVE TYPE. -
Page 22
8. Programozási folyamatábra Beállítás Software SP400 verzió (Ver X.XX ) MENÜ Kézi működtetés RETRN PSWRD (MCTL ) parancstól MANOP % Úthosz Autostroke aktiválása (TRAVL AUTOS (AUTOS ) 0-100% / 100-0% ) Megjegyzés: A TUNE, SET, és RUN parancsok csak a sikeres AUTOSTROKE lefútatása… -
Page 23
3 sec enter Enter Auto vissza Tarolt adatok torlese (RESET) Tarolt adatok visszaallitasa (RETRN) atmeneti adatok tarolasa (RTAIN) C-CAL DBAND VALVE SPLIT RANGE CTRLA AUTO mA INPUT OPERATION (% TRAVEL) SP400 MENU-be) IM-P343-37 CH Issue 3… -
Page 24
Gyors beállítás Programozási megjegyzések A szabályzó szelephez ilesztett poziciónáló beállítást igényel. A minimálisműködtető jel 3.6 mA, amely a poziciónáló működéséhez szükséges. A programozáshoz a SP400-as menűjébe kell belépni és futatni a az AUTOSROKE funkciót mielőtt az automata állásba lehetne kapcsolni. -
Page 25
9.2.1 VER -.— szoftver verzió Programozási megjegyzések A szofver verzió kijelzéséhez az enter gombot kell megnyomni Az enter gomb megnyomásával visszatér a menűbe. Automatikusan is visszatér 10 másodperc mulva a SP400-as menűbe. Nyomd és tarsd az enter gombot lenyomva a PSWRD menűhőz. IM-P343-37… -
Page 26
Resetting to default values (refer to Section 9 for default values) should be used if it is intended to use the positioner on a different control valve. If the SP400 positioner has been moved on its mounting or is to be fitted on a different control valve it will be necessary to undertake a new autostroke (AUTOS). -
Page 27
9.3 MANOP 3 second enter Manual operation C-CAL MANOP (MCTL) Fig. 31 Programming notes Press and hold the key for 3 seconds to enter manual control mode (MCTL). The display will count the 3 seconds. Press the key to enter the current calibration mode (C-CAL). Press the key to return to MANOP. -
Page 28
12 mA 100% 20 mA 20 mA In this way a perfect match is achieved between the setpoint of the PLC and the setpoint of the of the SP400 (i.e. the input current read by the SP400). IM-P343-37 CH Issue 3… -
Page 29
AUTOS — automatic autostroke commissioning % Travel 3 second (TRAVL Autostroke activate enter AUTOS 0-100% / (AUTOS) 100-0%) Fig. 32 Programming notes AUTOS provides access to: 1. Autostroke commissioning (AUTOS). 2. % travel display (TRAVL). AUTOS Autostroke provides an automatic commissioning routine which will take approximately 1 to 3 minutes to complete. -
Page 30
9.4.1 TRAVL — % travel display Programming notes Press the key to access TRAVL. Provides selection of valve travel display with option of 0 — 100% or 100 — 0%. Default is 0 — 100%. Use the keys to toggle selection. key to return to AUTOS. -
Page 31
Display = 0% Display = 100% Fig. 35 2-port valve normally open — TRAVL setting = 100% to 0% Display = 100% Display = 0% Fig. 36 2-port valve normally closed — TRAVL setting = 100% to 0% IM-P343-37 CH Issue 3… -
Page 32
100% 100% TRAVEL setting = 0 to 100% TRAVEL setting = 0 to 100% DISPLAY = 0% DISPLAY = 100% TRAVL setting = 100 to 0% TRAVL setting = 100 to 0% DISPLAY = 100% DISPLAY = 0% Fig. 37 3-port valve and spring extend actuator 100% 100% TRAVEL setting = 0 to 100%… -
Page 33
SET — setting of valve functions SPLIT DBAND VALVE CTRLA RANGE Fig. 39 Programming notes Provides access to basic valve set up functions. Press the key to scroll round all SET functions. Functions include: — Valve type (2-port or 3-port) (VALVE) — Control action (direct or reverse) -
Page 34
9.5.1 VALVE — valve type Programming notes 2-port On 2-port valves when the setpoint is 100%, the positioner will open to 95% of the stroke and display 100%, to prevent the back of the plug hitting the bonnet. Tight shut-off is set to 1% on ‘vent’ operation. 3-port On 3-port valves tight shut-off is set to 1% on ‘vent’ and ‘fill’ operations to ensure shut-off on both seats. -
Page 35
9.5.2 CTRLA — direct or reverse control action Programming notes Provides selection of direct (dIRCT) (4 — 20 mA) or reversed (REV) (20 — 4 mA) valve positioning control action. Press the keys to select desired action. Default action is dIRCT. Press the key to accept the displayed action and advance to deadband (DBAND). -
Page 36
Fig. 42 CTRL Control Action dIRCT or REV setting guidance Installed orientation At-rest position Control action 100% dIRCT 4 mA 20 mA 100% 100% 4 mA 20 mA 100% dIRCT 4 mA 20 mA 100% 100% (TRAVL) 0 — 100% 4 mA 20 mA 4 mA… -
Page 37
9.5.3 dbANd — deadband setting (positional sensitivity) Programming notes Dead-band provides adjustment of the valve positioning sensitivity relative to the input signal and is expressed as a % of the input signal span. Default value based on a 4 — 20 mA input signal span is 0.5%. To alter the displayed value press the keys. -
Page 38
The valve will move to a position as dictated by the input control signal. To alter or check SET or TUNE values it is necessary to return to the SP400 MENU. Press key for 3 seconds to return to the SP400 MENU. The display will count the and hold the 3 seconds.The positioner will vent the actuator and the valve will travel to its fail safe position. -
Page 39
At any time during automatic operation the mA input signal can be displayed by pressing the key. To return to the SP400 MENU press and hold the key for 3 seconds. Commissioning notes During normal operation the % valve travel will be continually displayed. A indicates that the valve is performing satisfactorily. -
Page 40
To change the filter proceed as follows: Ensure that the air supply to the positioner is isolated. Unscrew the filter plug (1) from the SP400 housing using a 5 mm hex. head socket key (refer to Figure 65). The replacement filter plug can now be fitted: Fit the ‘O’ ring (4) and filter (3) onto the filter plug (1) (refer to Figure 49). -
Page 41
11. Default values and program settings Default Programmed Main menu Sub-menu Setting options value value 2-PORT Valve type (2-PORT) 3-PORT (VALVE) Control action Direct (dIRCT) (dIRCT) (CTRLA) Reverse (REV) Deadband 0.5%, 1.5%, 0.5% (dBAND) 3.0%, 5.0% (range 4-20 mA) Split range LOW (range 4-13 mA) (SPLIT) HIGH (range 11-20 mA) -
Page 42
12. Glossary of display data 12.1 Main menu display functions Display Description SET UP Indicates that the SP400 positioner fitted to the valve has not been programmed or commissioned. Indicates that you have now entered the SP400 main menu. Provides access to: SP400 • View the version of the embedded software. -
Page 43
12.2 Sub-menu display functions Display Description VER x.xx Indicates the version of software embedded within the SP400 positioner. PSWRD Permits the upgrade from SP400 to SP500. RETRN Enables previously stored function values to be recalled. RTAIN Enables temporary changes made to function values to be retained. -
Page 44
IM-P343-37 CH Issue 3…
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
3.568.5275.300
Electropneumatic Smart Positioner
IM-P343-35 CH Issue 1
Printed in the UK
SP500
5. Installation
8. Programming
flow chart
9. Programming and
commissioning
11. Default values and
program settings
12. Glossary of
display data
IM-P343-35
CH Issue 1
© Copyright 2010
1
Related Manuals for Spirax Sarco SP500
Summary of Contents for Spirax Sarco SP500
-
Page 1
3.568.5275.300 IM-P343-35 CH Issue 1 SP500 Electropneumatic Smart Positioner Installation and Maintenance Instructions 1. Index 2. Safety information 3. Technical information 4. Options 5. Installation 6. Electrical connections 7. Quick start procedure 8. Programming flow chart 9. Programming and commissioning 10. Maintenance 11. Default values and program settings 12. Glossary of… -
Page 2: Table Of Contents
— setting of valve functions TUNE — setting of valve tune functions — automatic operation STRVL and RTIME — valve diagnostics RETRN — return to SP500 MENU in main menu 10. Maintenance and 10.1 Air supply quality troubleshooting 10.2 Fitting replacement filter plug kit 11.
-
Page 3: Safety Information
IP65 (see BS EN 60534-1 1998). 2.2 Electrical safety requirements The SP500 is a class III product which must only be powered from Safe Extra Low Voltage (SELV) sources whether by virtue of a 4 — 20 mA control signal or from a separate power supply.
-
Page 4: Technical Information
3. Technical information 3.1 Description The SP500 smart valve positioner is loop powered from a 4 — 20 mA input signal to provide accurate adaptive positional control of pneumatic actuated linear and quarter turn valves. Precise control is maintained through valve position feedback that automatically varies the pneumatic output pressure to overcome the effects of stem friction and flow forces to maintain desired valve position.
-
Page 5: Options
No. Features indicates all is OK ! Indicates a delay in positioning, this disappears when the position is reached Indicates that the value displayed is a percentage Indicates that the value displayed is the input current measured in mA Indicates that the value displayed is a time measured in seconds Indicates that you’re accessing the main programming menus…
-
Page 6
3.3 Materials Part Material Finish Case and cover Die cast aluminium Anti-corrosive paint to RAL5010 Magnet bracket Die cast aluminium 3.4 Programmable functions Autostroke Automatic commissioning routine Valve type 2-port or 3-port Selectable 0 to 100% or 100% to 0% % travel depending on valve / actuator configuration Control action… -
Page 7
4. Options 4.1 Pressure gauge block An optional pressure gauge block (Figure 3) can be fitted onto the SP500 positioner which includes two pressure gauges indicating air supply pressure and output air signal pressure to the actuator. The pressure gauge block can be retrospectively fitted using 2 off M5 socket head screws. -
Page 8: Electrical Connections
4.2 Retransmission and travel switches option board An option board can be fitted in the positioner to add valve position retransmission functionality and software travel switches functionality. The board generates a 4-20 mA current signal which represents the actual valve position. Moreover 2 output terminals are available to be configured as software travel switches.
-
Page 9
Rotate the mainboard and insert the option board (as shown in Figures 6, 7, 8 and 9). Rotate the mainboard to the initial position, fix it with the 4 screws, close the positioner and switch on the power supply and air supply. Fig. -
Page 10
4.3 External power supply option board The SP500 can host an option board for 24 V power supply. It’s a 4 wiring diagram: 2 wires for current loop and 2 wires for power supply through a 24 V external voltage. This reduces dramatically the voltage drop on the current loop. The drop is 7 V when the unit is powered by the loop (2 wires), it falls to 1 V when the 4 wires configuration is used. -
Page 11
Rotate the mainboard and insert the option board (as shown in Figures 12 and 13). Fig. 12 Fig. 13 Remove the Jumper J4 (Figure 14). Fig. 14 IM-P343-35 CH Issue 1… -
Page 12
Fig. 15 Insert the power supply option board. Collocate Jumper J4 as shown in Figures 15 and 16. Fig. 16 Rotate the mainboard to the initial position, fix it with the 4 screws, close the positioner and switch on the power supply and air supply. Once the option board is mounted, the positioner shall be powered according to the 4 wires connection diagram, refer to Section 6.2.3, ‘4 wires electrical connection’. -
Page 13: Maintenance
VDI / VDE 3845 compliant mounting kit for rotary actuators. 5.1.2 The SP500 has an enclosure rating of IP65 and should be installed in a location that will not exceed its ambient temperature limits of -10°C minimum and +80°C maximum.
-
Page 14
5.2 Sequence for mounting an SP500 positioner to a linear actuator Fig. 17 Pillar mounting kit for a linear actuator 5.2.1 Loosely attach the magnet bracket (2) to the valve / actuator connector (refer to Figures 17 and 18). Be sure it is positioned horizontally (as shown in Figure 18). -
Page 15
PN1000 Fig. 20 Bracket markings 5.2.3 If you’re not using a Spirax Sarco actuator, slide the bracket till the distance ‘A’ between the center of the magnet and the inner side of the mounting plate is 25 mm (Figure 21). -
Page 16
Fig. 22 Pillar actuator assembly Mounting plate Assembled Yoke actuator Fig.23 Yoke actuator assembly 5.2.5 Locate the protection plate onto the back of the SP500 positioner housing and fix in place (Figures 24 and 25). Protection plate Assembled Fig. 24 Fig. -
Page 17
5.2.6 5.2.7 Attach the positioner mounting plate to the Adjust the vertical position of the SP500 positioner as shown in Figures 26 and 27. positioner and mounting plate assembly, by sliding it up or down on the pillar style actuators,… -
Page 18
5.3 Sequence for mounting an SP500 positioner to a rotary actuator 5.3.1 Assembly for fitting an SP500 on to a ¼ turn valve. Fig. 30 Mounting kit IM-P343-35 CH Issue 1… -
Page 19
Fig. 32 Fig. 31 Fig. 33 IM-P343-35 CH Issue 1… -
Page 20
Fig. 34 Assembled Fig. 35 IM-P343-35 CH Issue 1… -
Page 21
5.3.2 Adjust the magnet orientation as illustrated in Figures 36 and 37 and tighten the bolt to fix the magnet into position. There should be a distance of between 5 and 14 mm between the magnet and the positioner. Refer to Figure 36 for actuator with clockwise rotation. Refer to Figure 37 for actuator with anti-clockwise rotation. -
Page 22
/ regulator is fitted in the mains air supply to the positioner. The filter / regulator should have a coalescing filter such as a Spirax Sarco type MPC2, or suitable compressed air pipework is used. -
Page 23
Systems: Installation design and practice or local equivalent. 6.2 Wiring diagrams 6.2.1 Terminal block MENU MANUAL AUTOS AUTOMATIC TUNE SP500 Fig. 39 Pole Description 24 V power supply option board 24 V external power supply (PWS) 4-20 mA current signal input… -
Page 24
6.2.2 Single loop applications The SP500 is loop powered using the 4 — 20 mA input signal source providing a minimum signal of 3.6 mA can be maintained. Minimum current 3.6 mA Maximum current 30 mA Maximum voltage drop < 7 V… -
Page 25
6.2.4 Travel switches- and 4-20 mA retransmission wiring digrams 2 k 22 k Travel switches 1 2 k 22 k Travel switches 2 Fig. 43 Software switches Example of customers external application wiring. 4 — 20 mA retransmit Fig. 44 4 — 20 mA retransmit Table 1 Ratings Supply… -
Page 26: Quick Start Procedure
Provide a minimum input signal of 3.6 mA to the positioner. SET-UP NOW should be displayed. 7.1.3 Ensure that upstream isolation valves are closed. key for 3 seconds to advance to SP500 MENU. Press and hold The display will count down the 3 seconds. 7.1.4 Press to advance to MANOP.
-
Page 27
7.2 3-port valves (with travel setting (TRAVL) 0 — 100%, refer to Figures 27 and 28) Proceed as above up to Section 7.1.9. 7.2.1 key once to advance to SET On completion of a successful autostroke press the in main menu. 7.2.2 key once to advance to VALVE TYPE. -
Page 28: Programming Flow Chart
Mounting position check Software SP500 (CALIB) version MENU (Ver X.XX) Manual operation From RETRN C-CAL (MCTL) (To SP500 MENU) MANOP % Travel (TRAVL Autostroke activate AUTOS 0-100% / (AUTOS) 100-0%) Note: SET, TUNE, and RUN can Valve type Actuator type…
-
Page 29
3 seconds enter Enter Clear stored values (RESET) Auto return Recall stored values (RETRN) Retain temporary values (RTAIN) Minimum Maximum Displayed % Minimum Maximum travel travel travel range range (MIN-T) (MAX-T) (DTRVL)† (MIN-R) (MAX-R) † Only if MIN-T / MAX-T not 0 / 100% Control action (CTRLA) Characterisation… -
Page 30: Programming And Commissioning
The positioner fitted to this control valve requires programming. A minimum input signal of 3.6 mA is required to power the positioner. To program the positioner it is necessary to enter SP500 MENU and carry out an autostroke commissioning routine (AUTOS) prior to putting the control valve into automatic operation.
-
Page 31
9.2.1 VER -.— software version Programming notes To view the version of the embedded software (VER-.—) press key. key to return to SP500 MENU. The display will automatically return to Press SP500 MENU after 10 seconds. IM-P343-35 CH Issue 1… -
Page 32
9.2.2 CALIB — mounting position calibration Programming notes To access CALIB press and hold key for 3 seconds. The display will count down the 3 seconds. You are now in calibrate mode. The LCD shows in % the magnet position in respect to the sensor board of the positioner, without any offset or scale up or down. -
Page 33
Resetting to default values (refer to Section 9 for default values) should be used if it is intended to use the positioner on a different control valve. If the SP500 positioner has been moved on its mounting or is to be fitted on a different control valve it will be necessary to undertake a new autostroke (AUTOS). -
Page 34
9.3 MANOP 3 second enter Manual operation C-CAL MANOP (MCTL) Fig. 47 Programming notes Press and hold key for 3 seconds to enter manual control mode (MCTL). The display will count down the 3 seconds. Press the key to enter the current calibration mode (C-CAL). Press return to MANOP. -
Page 35
12 mA 100% 20 mA 20 mA In this way a perfect match is achieved between the setpoint of the PLC and the setpoint of the of the SP500 (i.e. the input current read by the SP500). IM-P343-35 CH Issue 1… -
Page 36
AUTOS — automatic autostroke commissioning % Travel 3 second (TRAVL Autostroke activate enter AUTOS 0-100% / (AUTOS) 100-0%) Fig. 48 Programming notes AUTOS provides access to: 1. Autostroke commissioning (AUTOS). 2. % travel display (TRAVL). AUTOS Autostroke provides an automatic commissioning routine which will take approximately 1 to 3 minutes to complete. -
Page 37
9.4.1 TRAVL — % travel display Programming notes Press key to access TRAVL. Provides selection of valve travel display with option of 0 — 100% or 100 — 0%. Default is 0 — 100%. keys to toggle selection. key to return to AUTOS. Press Commissioning notes The selection of… -
Page 38
Display = 0% Display = 100% Fig. 51 2-port valve normally open — TRAVL setting = 100% to 0% Display = 100% Display = 0% Fig. 52 2-port valve normally closed — TRAVL setting = 100% to 0% IM-P343-35 CH Issue 1… -
Page 39
100% 100% TRAVEL setting = 0 to 100% TRAVEL setting = 0 to 100% DISPLAY = 0% DISPLAY = 100% TRAVL setting = 100 to 0% TRAVL setting = 100 to 0% DISPLAY = 100% DISPLAY = 0% Fig. 53 3-port valve and spring extend actuator 100% 100% TRAVEL setting = 0 to 100%… -
Page 40
SET — setting of valve functions Valve type Actuator type (VALVE 2-PORT / (ACT) VALVE 3-PORT) Maximum range Control action (MAX-R) (CTRLA) Minimum travel Minimum range (MIN-R) (MIN-T) Displayed % Maximum travel travel (MAX-T) (DTRVL)† † Only if MIN-T / MAX-T not 0 / 100% Fig. -
Page 41
9.5.1 VALVE — valve type Programming notes Provides selection between 2-port and 3-port valves. Default is 2-port valve. Default values for travel limit settings (MIN-T and MAX-T) and early vent / inflate settings (S-MIN and S-MAX) will depend on the valve type (2-port or 3-port) and control action (direct or reverse) as follows: 2-port 3-port… -
Page 42
9.5.3 CTRLA — direct or reverse control action Programming notes Provides selection of direct (dIRCT) (4 — 20 mA) or reversed (REV) (20 — 4 mA) valve positioning control action. Press keys to select desired action. Default action is dIRCT. Default values for travel limit settings (MIN-T and MAX-T) and early shut-off vent / inflate settings (S-MIN and S-MAX) will depend on the valve type (2-port or 3-port) and control action (direct or reverse) as follows:… -
Page 43
Fig. 58 CTRL Control Action dIRCT or REV setting guidance Installed orientation At-rest position Control action 100% dIRCT 4 mA 20 mA 100% 100% 4 mA 20 mA 100% dIRCT 4 mA 20 mA 100% 100% (TRAVL) 0 — 100% 4 mA 20 mA 4 mA… -
Page 44
9.5.4 MIN-T — minimum travel setting Programming notes Enables the minimum valve travel to be set as a percentage of the maximum travel obtained during autostroke. Maximum setting is MAX-T less 33.3%. Default value is 0%. keys to alter the displayed value. Press key to accept the displayed value and advance to the maximum travel setting (MAX-T). -
Page 45
9.5.6 DTRVL — displayed travel percentage Programming notes The full mechanical limits of valve travel (0 to 100%) are measured during autostroke (AUTOS). It is possible to limit the minimum and maximum valve travel by programming MIN-T and MAX-T values, i.e. MAX-T maximum travel limit of 95% (Autostroke default value for 2-port valves). -
Page 46
9.5.7 MIN-R — minimum signal span range Programming notes Enables the minimum mA input signal span range to be set. The value set will correspond to the minimum travel setting. Default value is 4 mA. keys to alter the displayed value. Minimum difference between MIN-R and MAX-R is 4 mA. -
Page 47
9.6 TUNE — setting of valve tune functions Shut-off minimum Dead-band (S-MIN) (dBand) TUNE Travel switch 2 Shut-off maximum (TS2) (S-MAX) Normally closed Travel switch 1 Characterisation (TS1) (LIN / FAST / Normally open EQUAL) Time to close Time to open (T-dWN) (T-UP) Fig. -
Page 48
9.6.1 dbANd — deadband setting (positional sensitivity) Programming notes Dead-band provides adjustment of the valve positioning sensitivity relative to the input signal and is expressed as a % of the input signal span. Default value based on a 4 — 20 mA input signal span is 0.5% with a minimum setting of 0.2%. -
Page 49
9.6.3 S-MAX — valve shut-off maximum Programming notes Provides the facility to fully inflate the actuator at a pre-determined input signal. The value set is a percentage of the input signal span range, i.e. setting a value of 10% with an input span range of 4 — 20 mA (16 mA), will cause the valve to close with an input signal of 18.4 mA i.e. -
Page 50
9.6.5 T-UP — valve slow opening action Programming notes This function slows down the time taken for the valve to travel from 0 to 100% lift. The time displayed is the fastest travel time measured during autostroke (AUTOS). 4 seconds may be displayed if ACT is set to ‘ON’ (refer to Section 9.5.2, page 41). -
Page 51
9.6.7 TS1 and TS2 software travel switches Two switches are available TS1 and TS2. TS1 is normally open and TS2 is normally closed. Switching action is set as a % of valve travel (refer to Figures 61 and 62). TS1 — software configured travel switch 1 (normally open) Programming notes The switching point can be set as a percentage of the valve travel between 0 to100%. -
Page 52
TS2 — software configured travel switch 2 (normally closed) Programming notes The switching point can be set as a percentage of the valve travel between 0 to 100%. A value can be set outside the limits of the travel settings (MIN-T) and (MAX-T). -
Page 53
The valve will move to a position as dictated by the input control signal. To alter or check SET or TUNE values it is necessary to return to SP500 MENU. Press and key for 3 seconds to return to SP500 MENU. The display will count down the 3 seconds. -
Page 54
At any time during automatic operation the mA input signal can be displayed by pressing key. To return to SP500 MENU press and hold key for 3 seconds. The display will count down the 3 seconds. You will advance to RETRN with the option of AUTO (automatic operation) or VENT (venting air from actuator). -
Page 55
9.8 STRVL and RTIME — valve diagnostics Provides visibility of total number of valve strokes (STRVL) and total valve run time in hours (RTIME). 9.8.1 STRVL — total stem travel Programming notes The number displayed should be multiplied by a factor of 10 to obtain the total number of complete valve strokes. -
Page 56
Press and hold key for 3 seconds. The display will count down the 3 seconds. This provides the facility to return to SP500 MENU with the option of staying in automatic operation (AUTO) or venting the actuator (VENT). Use keys key to select and return to SP500 MENU. -
Page 57
To change the filter proceed as follows: Ensure that the air supply to the positioner is isolated. Unscrew the filter plug (1) from the SP500 housing using a 5 mm hex. head socket key (refer to Figure 65). The replacement filter plug can now be fitted: Fit the ‘O’ ring (4) and filter (3) onto the filter plug (1) (refer to Figure 49). -
Page 58
11. Default values and program settings Programmed Main menu Sub-menu Setting options Default value value 2-PORT Valve type (2-PORT) 3-PORT (VALVE) Actuator type (ACT) Control action Direct (dIRCT) (dIRCT) (CTRLA) Reverse (REV) Minimum travel 0 to 66% (MIN-T) Maximum travel 33 to 100% 95% for 2-port (MAX-T) -
Page 59: Description
12. Glossary of display data 12.1 Main menu display functions Display Description SET UP Indicates that the SP500 positioner fitted to the valve has not been programmed or commissioned. Indicates that you have now entered the SP500 main menu. Provides access to: SP500 •…
-
Page 60: Port Valves
12.2 Sub-menu display functions Display Description VER x.xx Indicates the version of software embedded within the SP500 positioner. CALIb Provides facility for mounting position adjustment. RETRN Enables previously stored function values to be recalled. RTAIN Enables temporary changes made to function values to be retained.
-
Page 61: Sp500 Menu
Indicates the total number of valve strokes (x10). STRVL Value can be retained (RTAIN) or reset (RESET). Indicates the total run time of the SP500 in hours. RTIME Value can be retained (RTAIN) or reset (RESET) IM-P343-35 CH Issue 1…
-
Page 62
IM-P343-35 CH Issue 1… -
Page 63
IM-P343-35 CH Issue 1… -
Page 64
IM-P343-35 CH Issue 1…
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
3.568.5275.300
Electropneumatic Smart Positioner
IM-P343-35 CH Issue 1
Printed in the UK
SP500
5. Installation
8. Programming
flow chart
9. Programming and
commissioning
11. Default values and
program settings
12. Glossary of
display data
IM-P343-35
CH Issue 1
© Copyright 2010
1
Related Manuals for Spirax Sarco SP500
Summary of Contents for Spirax Sarco SP500
-
Page 1
3.568.5275.300 IM-P343-35 CH Issue 1 SP500 Electropneumatic Smart Positioner Installation and Maintenance Instructions 1. Index 2. Safety information 3. Technical information 4. Options 5. Installation 6. Electrical connections 7. Quick start procedure 8. Programming flow chart 9. Programming and commissioning 10. Maintenance 11. Default values and program settings 12. Glossary of… -
Page 2: Table Of Contents
— setting of valve functions TUNE — setting of valve tune functions — automatic operation STRVL and RTIME — valve diagnostics RETRN — return to SP500 MENU in main menu 10. Maintenance and 10.1 Air supply quality troubleshooting 10.2 Fitting replacement filter plug kit 11.
-
Page 3: Safety Information
IP65 (see BS EN 60534-1 1998). 2.2 Electrical safety requirements The SP500 is a class III product which must only be powered from Safe Extra Low Voltage (SELV) sources whether by virtue of a 4 — 20 mA control signal or from a separate power supply.
-
Page 4: Technical Information
3. Technical information 3.1 Description The SP500 smart valve positioner is loop powered from a 4 — 20 mA input signal to provide accurate adaptive positional control of pneumatic actuated linear and quarter turn valves. Precise control is maintained through valve position feedback that automatically varies the pneumatic output pressure to overcome the effects of stem friction and flow forces to maintain desired valve position.
-
Page 5: Options
No. Features indicates all is OK ! Indicates a delay in positioning, this disappears when the position is reached Indicates that the value displayed is a percentage Indicates that the value displayed is the input current measured in mA Indicates that the value displayed is a time measured in seconds Indicates that you’re accessing the main programming menus…
-
Page 6
3.3 Materials Part Material Finish Case and cover Die cast aluminium Anti-corrosive paint to RAL5010 Magnet bracket Die cast aluminium 3.4 Programmable functions Autostroke Automatic commissioning routine Valve type 2-port or 3-port Selectable 0 to 100% or 100% to 0% % travel depending on valve / actuator configuration Control action… -
Page 7
4. Options 4.1 Pressure gauge block An optional pressure gauge block (Figure 3) can be fitted onto the SP500 positioner which includes two pressure gauges indicating air supply pressure and output air signal pressure to the actuator. The pressure gauge block can be retrospectively fitted using 2 off M5 socket head screws. -
Page 8: Electrical Connections
4.2 Retransmission and travel switches option board An option board can be fitted in the positioner to add valve position retransmission functionality and software travel switches functionality. The board generates a 4-20 mA current signal which represents the actual valve position. Moreover 2 output terminals are available to be configured as software travel switches.
-
Page 9
Rotate the mainboard and insert the option board (as shown in Figures 6, 7, 8 and 9). Rotate the mainboard to the initial position, fix it with the 4 screws, close the positioner and switch on the power supply and air supply. Fig. -
Page 10
4.3 External power supply option board The SP500 can host an option board for 24 V power supply. It’s a 4 wiring diagram: 2 wires for current loop and 2 wires for power supply through a 24 V external voltage. This reduces dramatically the voltage drop on the current loop. The drop is 7 V when the unit is powered by the loop (2 wires), it falls to 1 V when the 4 wires configuration is used. -
Page 11
Rotate the mainboard and insert the option board (as shown in Figures 12 and 13). Fig. 12 Fig. 13 Remove the Jumper J4 (Figure 14). Fig. 14 IM-P343-35 CH Issue 1… -
Page 12
Fig. 15 Insert the power supply option board. Collocate Jumper J4 as shown in Figures 15 and 16. Fig. 16 Rotate the mainboard to the initial position, fix it with the 4 screws, close the positioner and switch on the power supply and air supply. Once the option board is mounted, the positioner shall be powered according to the 4 wires connection diagram, refer to Section 6.2.3, ‘4 wires electrical connection’. -
Page 13: Maintenance
VDI / VDE 3845 compliant mounting kit for rotary actuators. 5.1.2 The SP500 has an enclosure rating of IP65 and should be installed in a location that will not exceed its ambient temperature limits of -10°C minimum and +80°C maximum.
-
Page 14
5.2 Sequence for mounting an SP500 positioner to a linear actuator Fig. 17 Pillar mounting kit for a linear actuator 5.2.1 Loosely attach the magnet bracket (2) to the valve / actuator connector (refer to Figures 17 and 18). Be sure it is positioned horizontally (as shown in Figure 18). -
Page 15
PN1000 Fig. 20 Bracket markings 5.2.3 If you’re not using a Spirax Sarco actuator, slide the bracket till the distance ‘A’ between the center of the magnet and the inner side of the mounting plate is 25 mm (Figure 21). -
Page 16
Fig. 22 Pillar actuator assembly Mounting plate Assembled Yoke actuator Fig.23 Yoke actuator assembly 5.2.5 Locate the protection plate onto the back of the SP500 positioner housing and fix in place (Figures 24 and 25). Protection plate Assembled Fig. 24 Fig. -
Page 17
5.2.6 5.2.7 Attach the positioner mounting plate to the Adjust the vertical position of the SP500 positioner as shown in Figures 26 and 27. positioner and mounting plate assembly, by sliding it up or down on the pillar style actuators,… -
Page 18
5.3 Sequence for mounting an SP500 positioner to a rotary actuator 5.3.1 Assembly for fitting an SP500 on to a ¼ turn valve. Fig. 30 Mounting kit IM-P343-35 CH Issue 1… -
Page 19
Fig. 32 Fig. 31 Fig. 33 IM-P343-35 CH Issue 1… -
Page 20
Fig. 34 Assembled Fig. 35 IM-P343-35 CH Issue 1… -
Page 21
5.3.2 Adjust the magnet orientation as illustrated in Figures 36 and 37 and tighten the bolt to fix the magnet into position. There should be a distance of between 5 and 14 mm between the magnet and the positioner. Refer to Figure 36 for actuator with clockwise rotation. Refer to Figure 37 for actuator with anti-clockwise rotation. -
Page 22
/ regulator is fitted in the mains air supply to the positioner. The filter / regulator should have a coalescing filter such as a Spirax Sarco type MPC2, or suitable compressed air pipework is used. -
Page 23
Systems: Installation design and practice or local equivalent. 6.2 Wiring diagrams 6.2.1 Terminal block MENU MANUAL AUTOS AUTOMATIC TUNE SP500 Fig. 39 Pole Description 24 V power supply option board 24 V external power supply (PWS) 4-20 mA current signal input… -
Page 24
6.2.2 Single loop applications The SP500 is loop powered using the 4 — 20 mA input signal source providing a minimum signal of 3.6 mA can be maintained. Minimum current 3.6 mA Maximum current 30 mA Maximum voltage drop < 7 V… -
Page 25
6.2.4 Travel switches- and 4-20 mA retransmission wiring digrams 2 k 22 k Travel switches 1 2 k 22 k Travel switches 2 Fig. 43 Software switches Example of customers external application wiring. 4 — 20 mA retransmit Fig. 44 4 — 20 mA retransmit Table 1 Ratings Supply… -
Page 26: Quick Start Procedure
Provide a minimum input signal of 3.6 mA to the positioner. SET-UP NOW should be displayed. 7.1.3 Ensure that upstream isolation valves are closed. key for 3 seconds to advance to SP500 MENU. Press and hold The display will count down the 3 seconds. 7.1.4 Press to advance to MANOP.
-
Page 27
7.2 3-port valves (with travel setting (TRAVL) 0 — 100%, refer to Figures 27 and 28) Proceed as above up to Section 7.1.9. 7.2.1 key once to advance to SET On completion of a successful autostroke press the in main menu. 7.2.2 key once to advance to VALVE TYPE. -
Page 28: Programming Flow Chart
Mounting position check Software SP500 (CALIB) version MENU (Ver X.XX) Manual operation From RETRN C-CAL (MCTL) (To SP500 MENU) MANOP % Travel (TRAVL Autostroke activate AUTOS 0-100% / (AUTOS) 100-0%) Note: SET, TUNE, and RUN can Valve type Actuator type…
-
Page 29
3 seconds enter Enter Clear stored values (RESET) Auto return Recall stored values (RETRN) Retain temporary values (RTAIN) Minimum Maximum Displayed % Minimum Maximum travel travel travel range range (MIN-T) (MAX-T) (DTRVL)† (MIN-R) (MAX-R) † Only if MIN-T / MAX-T not 0 / 100% Control action (CTRLA) Characterisation… -
Page 30: Programming And Commissioning
The positioner fitted to this control valve requires programming. A minimum input signal of 3.6 mA is required to power the positioner. To program the positioner it is necessary to enter SP500 MENU and carry out an autostroke commissioning routine (AUTOS) prior to putting the control valve into automatic operation.
-
Page 31
9.2.1 VER -.— software version Programming notes To view the version of the embedded software (VER-.—) press key. key to return to SP500 MENU. The display will automatically return to Press SP500 MENU after 10 seconds. IM-P343-35 CH Issue 1… -
Page 32
9.2.2 CALIB — mounting position calibration Programming notes To access CALIB press and hold key for 3 seconds. The display will count down the 3 seconds. You are now in calibrate mode. The LCD shows in % the magnet position in respect to the sensor board of the positioner, without any offset or scale up or down. -
Page 33
Resetting to default values (refer to Section 9 for default values) should be used if it is intended to use the positioner on a different control valve. If the SP500 positioner has been moved on its mounting or is to be fitted on a different control valve it will be necessary to undertake a new autostroke (AUTOS). -
Page 34
9.3 MANOP 3 second enter Manual operation C-CAL MANOP (MCTL) Fig. 47 Programming notes Press and hold key for 3 seconds to enter manual control mode (MCTL). The display will count down the 3 seconds. Press the key to enter the current calibration mode (C-CAL). Press return to MANOP. -
Page 35
12 mA 100% 20 mA 20 mA In this way a perfect match is achieved between the setpoint of the PLC and the setpoint of the of the SP500 (i.e. the input current read by the SP500). IM-P343-35 CH Issue 1… -
Page 36
AUTOS — automatic autostroke commissioning % Travel 3 second (TRAVL Autostroke activate enter AUTOS 0-100% / (AUTOS) 100-0%) Fig. 48 Programming notes AUTOS provides access to: 1. Autostroke commissioning (AUTOS). 2. % travel display (TRAVL). AUTOS Autostroke provides an automatic commissioning routine which will take approximately 1 to 3 minutes to complete. -
Page 37
9.4.1 TRAVL — % travel display Programming notes Press key to access TRAVL. Provides selection of valve travel display with option of 0 — 100% or 100 — 0%. Default is 0 — 100%. keys to toggle selection. key to return to AUTOS. Press Commissioning notes The selection of… -
Page 38
Display = 0% Display = 100% Fig. 51 2-port valve normally open — TRAVL setting = 100% to 0% Display = 100% Display = 0% Fig. 52 2-port valve normally closed — TRAVL setting = 100% to 0% IM-P343-35 CH Issue 1… -
Page 39
100% 100% TRAVEL setting = 0 to 100% TRAVEL setting = 0 to 100% DISPLAY = 0% DISPLAY = 100% TRAVL setting = 100 to 0% TRAVL setting = 100 to 0% DISPLAY = 100% DISPLAY = 0% Fig. 53 3-port valve and spring extend actuator 100% 100% TRAVEL setting = 0 to 100%… -
Page 40
SET — setting of valve functions Valve type Actuator type (VALVE 2-PORT / (ACT) VALVE 3-PORT) Maximum range Control action (MAX-R) (CTRLA) Minimum travel Minimum range (MIN-R) (MIN-T) Displayed % Maximum travel travel (MAX-T) (DTRVL)† † Only if MIN-T / MAX-T not 0 / 100% Fig. -
Page 41
9.5.1 VALVE — valve type Programming notes Provides selection between 2-port and 3-port valves. Default is 2-port valve. Default values for travel limit settings (MIN-T and MAX-T) and early vent / inflate settings (S-MIN and S-MAX) will depend on the valve type (2-port or 3-port) and control action (direct or reverse) as follows: 2-port 3-port… -
Page 42
9.5.3 CTRLA — direct or reverse control action Programming notes Provides selection of direct (dIRCT) (4 — 20 mA) or reversed (REV) (20 — 4 mA) valve positioning control action. Press keys to select desired action. Default action is dIRCT. Default values for travel limit settings (MIN-T and MAX-T) and early shut-off vent / inflate settings (S-MIN and S-MAX) will depend on the valve type (2-port or 3-port) and control action (direct or reverse) as follows:… -
Page 43
Fig. 58 CTRL Control Action dIRCT or REV setting guidance Installed orientation At-rest position Control action 100% dIRCT 4 mA 20 mA 100% 100% 4 mA 20 mA 100% dIRCT 4 mA 20 mA 100% 100% (TRAVL) 0 — 100% 4 mA 20 mA 4 mA… -
Page 44
9.5.4 MIN-T — minimum travel setting Programming notes Enables the minimum valve travel to be set as a percentage of the maximum travel obtained during autostroke. Maximum setting is MAX-T less 33.3%. Default value is 0%. keys to alter the displayed value. Press key to accept the displayed value and advance to the maximum travel setting (MAX-T). -
Page 45
9.5.6 DTRVL — displayed travel percentage Programming notes The full mechanical limits of valve travel (0 to 100%) are measured during autostroke (AUTOS). It is possible to limit the minimum and maximum valve travel by programming MIN-T and MAX-T values, i.e. MAX-T maximum travel limit of 95% (Autostroke default value for 2-port valves). -
Page 46
9.5.7 MIN-R — minimum signal span range Programming notes Enables the minimum mA input signal span range to be set. The value set will correspond to the minimum travel setting. Default value is 4 mA. keys to alter the displayed value. Minimum difference between MIN-R and MAX-R is 4 mA. -
Page 47
9.6 TUNE — setting of valve tune functions Shut-off minimum Dead-band (S-MIN) (dBand) TUNE Travel switch 2 Shut-off maximum (TS2) (S-MAX) Normally closed Travel switch 1 Characterisation (TS1) (LIN / FAST / Normally open EQUAL) Time to close Time to open (T-dWN) (T-UP) Fig. -
Page 48
9.6.1 dbANd — deadband setting (positional sensitivity) Programming notes Dead-band provides adjustment of the valve positioning sensitivity relative to the input signal and is expressed as a % of the input signal span. Default value based on a 4 — 20 mA input signal span is 0.5% with a minimum setting of 0.2%. -
Page 49
9.6.3 S-MAX — valve shut-off maximum Programming notes Provides the facility to fully inflate the actuator at a pre-determined input signal. The value set is a percentage of the input signal span range, i.e. setting a value of 10% with an input span range of 4 — 20 mA (16 mA), will cause the valve to close with an input signal of 18.4 mA i.e. -
Page 50
9.6.5 T-UP — valve slow opening action Programming notes This function slows down the time taken for the valve to travel from 0 to 100% lift. The time displayed is the fastest travel time measured during autostroke (AUTOS). 4 seconds may be displayed if ACT is set to ‘ON’ (refer to Section 9.5.2, page 41). -
Page 51
9.6.7 TS1 and TS2 software travel switches Two switches are available TS1 and TS2. TS1 is normally open and TS2 is normally closed. Switching action is set as a % of valve travel (refer to Figures 61 and 62). TS1 — software configured travel switch 1 (normally open) Programming notes The switching point can be set as a percentage of the valve travel between 0 to100%. -
Page 52
TS2 — software configured travel switch 2 (normally closed) Programming notes The switching point can be set as a percentage of the valve travel between 0 to 100%. A value can be set outside the limits of the travel settings (MIN-T) and (MAX-T). -
Page 53
The valve will move to a position as dictated by the input control signal. To alter or check SET or TUNE values it is necessary to return to SP500 MENU. Press and key for 3 seconds to return to SP500 MENU. The display will count down the 3 seconds. -
Page 54
At any time during automatic operation the mA input signal can be displayed by pressing key. To return to SP500 MENU press and hold key for 3 seconds. The display will count down the 3 seconds. You will advance to RETRN with the option of AUTO (automatic operation) or VENT (venting air from actuator). -
Page 55
9.8 STRVL and RTIME — valve diagnostics Provides visibility of total number of valve strokes (STRVL) and total valve run time in hours (RTIME). 9.8.1 STRVL — total stem travel Programming notes The number displayed should be multiplied by a factor of 10 to obtain the total number of complete valve strokes. -
Page 56
Press and hold key for 3 seconds. The display will count down the 3 seconds. This provides the facility to return to SP500 MENU with the option of staying in automatic operation (AUTO) or venting the actuator (VENT). Use keys key to select and return to SP500 MENU. -
Page 57
To change the filter proceed as follows: Ensure that the air supply to the positioner is isolated. Unscrew the filter plug (1) from the SP500 housing using a 5 mm hex. head socket key (refer to Figure 65). The replacement filter plug can now be fitted: Fit the ‘O’ ring (4) and filter (3) onto the filter plug (1) (refer to Figure 49). -
Page 58
11. Default values and program settings Programmed Main menu Sub-menu Setting options Default value value 2-PORT Valve type (2-PORT) 3-PORT (VALVE) Actuator type (ACT) Control action Direct (dIRCT) (dIRCT) (CTRLA) Reverse (REV) Minimum travel 0 to 66% (MIN-T) Maximum travel 33 to 100% 95% for 2-port (MAX-T) -
Page 59: Description
12. Glossary of display data 12.1 Main menu display functions Display Description SET UP Indicates that the SP500 positioner fitted to the valve has not been programmed or commissioned. Indicates that you have now entered the SP500 main menu. Provides access to: SP500 •…
-
Page 60: Port Valves
12.2 Sub-menu display functions Display Description VER x.xx Indicates the version of software embedded within the SP500 positioner. CALIb Provides facility for mounting position adjustment. RETRN Enables previously stored function values to be recalled. RTAIN Enables temporary changes made to function values to be retained.
-
Page 61: Sp500 Menu
Indicates the total number of valve strokes (x10). STRVL Value can be retained (RTAIN) or reset (RESET). Indicates the total run time of the SP500 in hours. RTIME Value can be retained (RTAIN) or reset (RESET) IM-P343-35 CH Issue 1…
-
Page 62
IM-P343-35 CH Issue 1… -
Page 63
IM-P343-35 CH Issue 1… -
Page 64
IM-P343-35 CH Issue 1…
В ранее вышедшей статье мы подробно рассказали об особенностях клапанов серии Spira-TrolTM и рассмотрели варианты их применения в различных процессах. Но, как известно, сам клапан это всего лишь часть устройства для регулирования потока среды, которое также включает в себя исполнительный механизм, например, пневматический привод, который, в свою очередь, может быть оснащен позиционером.
Позиционер – это дополнительное устройство, которое обычно монтируют на стойках пневмопривода и которое имеет бесконтактную или механическую связь со штоком привода/клапана для получения обратной связи о его положении. Электропневматический позиционер преобразует электрический сигнал в пневматический сигнал сжатого воздуха, который направляется в пневмопривод для перемещения штока клапана в требуемое положение.
Часто задают вопрос: «В каком случае следует использовать позиционер?»
Рассматривать необходимость использования позиционера нужно в следующих обстоятельствах:
1. Когда требуется точное позиционирование штока клапана.
2. Когда нужно ускорить отклик клапана на изменение управляющего сигнала, что обеспечивается более высоким давлением воздуха управляющего сигнала, поступающего с позиционера на пневмопривод.
3. Для возможности работы клапана на более высоком перепаде давления на клапане (позиционер действует в качестве усилителя сигнала).
4. В случаях, когда трение в уплотнении штока клапана приводит к слишком сильному запаздыванию в реакции на изменение управляющего сигнала.
5. Для обеспечения линейности отклика при использовании нелинейного привода.
6. В случаях, когда изменения перепада давления в клапане могут приводить к изменению положения плунжера клапана.
Для систем регулирования большинство процессов с такими средами, как пар и вода, обычно используют либо электрические, либо пневматические привода. Пневматические более востребованные в технологических процессах благодаря быстродействию (по сравнению с электрическими) и возможности занимать безопасное положение при потере питания или управляющего сигнала под действием пружин.
Темой данной статьи будут являться электропневматические позиционеры, которые являются неотъемлемой частью системы регулирования. Мы опишем производимые нашей компанией позиционеры, их технические характеристики и отличительные особенности.
На сегодняшний день наша компания производит три различных электропневматических позиционера (нажмите на картинку, чтобы узнать больше о каждом продукте):
Модель ЕР500 – это по сути обновленная версия позиционера ЕР5, который имеет достаточно простую и надежную конструкцию. Данный тип электропневматического позиционера зарекомендовал себя как надежное и высокоточное устройство, которое востребовано на рынке.
Более подробно хотелось бы остановиться на типе SP400/500. Эта серия была специально разработана с учетом требований и пожеланий наших заказчиков.
Отличительными особенностями данной серии являются:
- простая и быстрая функция авто-настройки (запускается нажатием одной кнопки, длительность процедуры 1,5-2 минуты)
- для обеспечения контакта со штоком клапана используется бесконтактный датчик Холла, что позволяет обеспечит более точную обратную связь по положению клапана, исключает ошибки и выход из строя из-за нарушения механической связи;
- программируемые функции и встроенная клавиатура (для корректировки параметров не требует подключения сторонних устройств);
- электрические соединения с низким сопротивлением. Позиционер не требует внешних источников питания, достаточно питания от управляющего сигнала;
- цифровой контроль расхода сжатого воздуха – благодаря данному решению позиционер практически не потребляет воздух в стационарных режимах.
Таким образом позиционеры имеют очень низкую стоимость эксплуатации. Учитывая постоянно растущие цены на энергоносители значение потребления сжатого воздуха становится важнее с каждым годом.
- расширенное меню программируемых функций для более точного управления клапаном
- возможность установки (опционально) платы ретрансляции сигнала о фактическом положении клапана
- доступна версия с HART протоколом
Дополнительную информацию по электропневматических позиционерах производства Spirax Sarco вы можете найти на нашем сайте или позвонить по телефону 8 800 551-00-25.
Download Installation and maintenance instructions manual of Spirax Sarco SP500 Controller, Valve Positioners for Free or View it Online on All-Guides.com.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
IM-P343-35 CH Issue 1 1
SP500
Electropneumatic Smart Positioner
Installation and Maintenance Instructions
IM-P343-35
CH Issue 1
3.568.5275.300
1. Index
2. Safetyinformation
3. Technical information
4. Options
5. Installation
6. Electricalconnections
7. Quickstartprocedure
8. Programming
flowchart
9. Programmingand
commissioning
10. Maintenance
11. Defaultvaluesand
programsettings
12. Glossaryof
displaydata
Printed in the UK
© Copyright 2010
Spirax Sarco SP500: Available Instructions
Note for Owners:
Guidesimo.com webproject is not a service center of Spirax Sarco trademark and does not carries out works for diagnosis and repair of faulty Spirax Sarco SP500 equipment. For quality services, please contact an official service center of Spirax Sarco company. On our website you can read and download documentation for your Spirax Sarco SP500 device for free and familiarize yourself with the technical specifications of device.
-
Eaton CGLine+ Touchscreen Controller
CGLine+ Web ControllerManual Betriebsanleitung ManuelTarget group: Skilled electricians Zielgruppe: ElektrofachkraftPublic cible : Électriciens confirmésCGLine+ Touchscreen ControllerEnglish …………………………….. 3Deutsch …………………………. 29Français …………………………. 55 …
CGLine+ Touchscreen Controller Controller, 82
-
EZPull MTX-8
OverviewEZPull MTX-8 is a multi-target controller for use in Five-Stand, FITASC, Super-Sporting andother clay target sports that require multiple traps. EZPull MTX-8 is designed to control up to 8traps. The MTX-8 can be used in manual mode for all multiple traps clay target sports. The MTX-8 also features automatic sequencing from six programmable 5-Stand menus.EEZZPPuullllMMTTXX—88UUsseerrMMaann …
MTX-8 Recording Equipment, 3
-
Sony BDV-E780W
Watch Full HD 1080p Blu-ray Disc™ movies and immerse yourself in powerful 5.1 channel HD surround sound with the integrated Sony® smart 3D Blu-ray Disc™ Home Theater System — BDV-E780W.3 Wirelessly stream movies, TV episodes, music and live sports events from Netix®, YouTube™, HuluPlus™, Pandora®, and more.1 Plus enjoy the convenience of wireless rear speakers, 2 HDMI® inputs, and a …
BDV-E780W Home Theater System, 4
-
Graco Series A
309445Rev. ETo find your local Graco authorized servicecenter: Call us at 1–800–690–2894 Visit our website at www.graco.comINSTRUCTIONS–PARTS LISTImportant Safety Instructions Read all warnings and instructionsin this manual. Save theseinstructions.Pressure Roller with 20” Heavy Duty Extension, EvenFlowt RollerFrame and Contractort Inline Valve– For the rolled application of …
Series A Paint Sprayer, 10
-
HP MSM710
InMSM710 Controller QuickstartThis Quickstart applies to both the MSM710 Access Controller (J9328A) and the MSM710 Mobility Controller (J9325A).This Quickstart introduces the HP ProCurve Networking MSM710 Controller and shows you how to get started using it. After following the directions in this Quickstart, see the MSM7xx Controllers Management and Configuration Guide available at: www.hp.com/go/ …
MSM710 Controller, 6
-
YASKAWA NX100
Part Number: 174074-1CDRevision: 0MANUAL NO. 1HW0482711NX100 OPTIONSINSTRUCTIONSFOR CONVEYOR SYNCHRONIZED FUNCTIONUpon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.MOTOMAN INSTRUCTIONSMOTOMAN- INSTRUCTIONSNX100 INSTRUCTIONSNX100 OPERATOR’S MANUALNX100 MAINTENANCE MANUALThe NX100 operator’s manual above corre …
NX100 Controller, 86
-
Eaton RTC-100
Contents1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22. Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53. Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …
RTC-100 Controller, 20
-
Azbil BC-R35 Series
1 ADD FURNACE CO.,LTD. 44 ซอยบรมราชชนนี � …
BC-R35 Series Controller, 17
-
Resol DeltaSol CS/2
Thank you for buying this RESOL product.Please read this manual carefully to get the best performance from this unit. Please keep this manual carefully.Manualwww.resol.com enSolar controllerManual for the specialised craftsmanInstallationOperationFunctions and optionsTroubleshootingVersion 1.11*11204303*11204303DeltaSol® CS/2 …
DeltaSol CS/2 Controller, 32
Popular Controller User Guides:
3.1 Description
The SP500 smart valve positioner is loop powered from a 4 — 20 mA input signal to provide
accurate adaptive positional control of pneumatic actuated linear and quarter turn valves.
Precise control is maintained through valve position feedback that automatically varies the
pneumatic output pressure to overcome the effects of stem friction and flow forces to maintain
desired valve position. Indication of valve position is provided through a continuous digital
display of % travel. Valve position feedback is retrieved by means of a non contact technology
based on Hall effect. The pneumatics are based on piezovalve technology — Therefore, high
resolution, high reliability, vibration insensitivity and extremely low air consumption is
guaranteed at steady state.
The SP500 includes many smart functions that can be fully programmed through menu driven
software using an integral keypad and LCD alphanumeric data. Valve commissioning is
simplified through an autostroke routine and display of programming status, software travel
switch status, mA input signal and valve diagnostics data. Moreover, the absence of
mechanical linkages between valve stem and positioner, drastically simplifies the mounting
procedure and reduces the time required. The SP500 is supplied with a NAMUR standard
mounting kit for attachment to yoke or pillar mounted actuators. For quarter turn valves, a
mounting kit compliant to VDI / VDE 3845 is supplied.
4
12
11
Fig. 1
No. Part
1.
LCD display
2.
Main menu functions with LCD flag indication
3.
Signal pressure to activator
4.
Gland connection for wiring M20
5.
Terminal block
6.
Increase value or toggle value key
7.
Decrease value or toggle value key
8.
Enter key
9.
Supply pressure to positioner
10.
Optional pressure gauge block with gauges
11.
Spare M20 gland connection for wiring a 4-20 mA retransmission or software switches
12.
External earth
13.
Internal earth
4
1
13
5
6
2
7
8
IM-P343-35 CH Issue 1
3
10
9
|
Related Devices:
|
Types of Manuals:
The main types of Spirax Sarco SP500 instructions:
- User guide — rules of useing and characteristics
- Service manual — repair, diagnostics, maintenance
- Operation manual — description of the main functions of equipment
Controller, Valve Positioners Instructions by Spirax Sarco:
-
Aircraft Extras FPS-Plus-nt
4908 McKenna Ct., Columbus, Ohio, 43221 USA (614) 876-6345www.aircraftextras.com [email protected] INSTALLATION MANUALTHANK YOU! . . . for purchasing the FPS-Plus-nt system from Aircraft Extras, Inc. Please review ALLinstructions thoroughly before you install and program the FPS- …
FPS-Plus-nt Valve Positioners, 8
-
XERYON XRT-A
V1.2 Page 1 of 14 www.xeryon.com XRT-A Manual © Copyright by Xeryon BVBA, Interleuvenlaan 62, 3001 Leuven, Belgium All rights reserved. No part of this manual may be duplicated, reproduced, stored in an information system or processed or transferred in any other form without prior ex …
XRT-A Valve Positioners, 14
-
Bosch Rexroth PE 2/XP
PE 2/XHPE 2/XP3 842 523 895/2015-02Replaces: –DE+EN+FR+IT+ESMontageanleitung • Assembly instructions • Instructions de montage Istruzioni per il montaggio • Instrucciones de montajePositioniereinheit PE 2/XPPE 2/XP Positioning unitUnité de positionnement PE 2/XP Unità di posizionamento PE 2/XPUnidad de posici …
Rexroth PE 2/XP Valve Positioners, 32
-
Siemens SIPART PS2
1 English ………………………………………………………………………………….. 3 Deutsch ……………………………………………………………………………….. 21 Français ………………………………………………………………………………. 39 Ita …
SIPART PS2 Kitchen Appliances, 112
-
Parker 406LXR Series
Parker -- � …
406LXR Series Valve Positioners, 68
-
YOKOGAWA Juxta UZ011
User’sManualNetwork Solutions Business Divisiion2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JapanPhone: +81-422-52-7179 Facsimile: +81-422-52-6793Please read through this User’s Manual before use for correct handling.Please keep this User’s Manual for future reference.Model UZ011Analog Positioner1. CAUTIONARY …
Juxta UZ011 Valve Positioners, 2
-
Spirax Sarco SP8-10
IM-P707-01 CTLS Issue 11SP8-10 Smart positioner© Copyright 2021SP8-10Smart positionerInstallation and Maintenance InstructionsIM-P707-01CTLS Issue 11. Safety information2. General product information3. Installation4. Commissioning5. Operation6. Troubleshooting7. Maintenance3440650/1 …
SP8-10 Valve Positioners, 88
Spirax Sarco SP500 Valve Positioners PDF User Guides and Manuals for Free Download: Found (2) Manuals for Spirax Sarco SP500 Device Model (Installation And Maintenance Instructions Manual)
More Valve Positioners Device Models:
-
Fisher
3582
www.Fisher.comFisherr 3582 and 3582i Positioners, 582iElectro‐Pneumatic Converter, and 3583 ValveStem Position TransmitterContentsIntroduction 2……………………………Scope of Manual 2………………………..Description 2……………………………Type Number Descriptions 6…………….Specifi …
3582 Valve Positioners, 56
-
Ros
PT-25FB-24VDC-RS-485
20-02245 REV E RS-485 CONTROLLED UNDERWATER POSITIONERS MODEL PT-25FB-24VDC-RS-485 MODEL R-25FB-24VDC-RS-485 OPERATING AND MAINTENANCE MANUAL SERIAL NUMBER: __________ SALES ORDER: __________ 5618 Copley Drive San Diego, CA 92111-7902 TEL: (858) 565-8500 FAX: (858) 565-880 …
PT-25FB-24VDC-RS-485 Valve Positioners, 22
-
Becker
HPP-SB
Section Page Introduction 2 Scope of Manual 2 Description 2 Technical Information 3 Specifications 3 Mat …
HPP-SB Valve Positioners, 26
-
KAUP
T456Z
SAP 100105 en Operating Manual Original Operating Manual 1 Edition 07/15 Subject to modifications Rotating Fork Positioner 3T456ZA, 3T496Z, 3T496ZA 4T456Z, 4T456ZA, 4T496Z, 4T496ZA T456Z T496Z Rotating Fork Positioner without sideshift Rotating Fork Positioner with sideshift T456ZA T496ZA Rotating Fork Posi …
T456Z Forklifts, 24
Recommended Documentation: