Руководство по эксплуатации компрессора кайзер

  1. Manuals
  2. Brands
  3. KAESER Manuals
  4. Air Compressor

ManualsLib has more than 51 KAESER Air Compressor manuals

Click on an alphabet below to see the full list of models starting with that letter:

A
C
E
M
P
S

Models

Document Type

A

Aircenter SX 3

Service Manual

Aircenter SX 4

Service Manual

Aircenter SX 5

Service Manual

Aircenter SX 7.5

Service Manual

AIRTOWER 3C

Operator’s Manual

AIRTOWER 4C

Operator’s Manual

AIRTOWER 5C

Operator’s Manual

AIRTOWER 7.5C

Operator’s Manual

ASK 27

Service Manual

ASK 32

Service Manual

ASK 35

Service Manual

ASK T series

Service Manual

C

CSD 102

Service Manual

CSD 122

Service Manual

CSD 75

Service Manual

CSD 82

Service Manual

CSD series

Service Manual

E

EPC 1000-2-500

Service Manual

EPC 1500-G

Assembly And Operating Manual

EPC 230-2-100

Service Manual

EPC 230-2-250

Service Manual

EPC 340-G

Assembly And Operating Manual

EPC 420-2-250

Service Manual

EPC 440-G

Assembly And Operating Manual

EPC 550-2-250

Service Manual

EPC 550-2-350

Service Manual

EPC 630-G

Assembly And Operating Manual

EPC 750-2-500

Service Manual

EPC 840-G

Assembly And Operating Manual

EPC Series

Service Manual

EPC-G Series

Assembly And Operating Manual

EPC1100-G

Assembly And Operating Manual

ESD 352 SFC

Technical Documentation Manual

ESD 442 SFC

Technical Documentation Manual

ESD.2C

Technical Documentation Manual

M

M 64

Operator’s Manual

M100

Operator’s Manual

M122

Service Manual

M135 SIGMA CONTROL MOBIL

Service Manual

M26

Service Manual

M27

Operator’s Manual

M43

Service Manual

P

Premium Compact W 200/4

Service Manual

Premium Compact W 250/4

Service Manual

Premium Compact W 300/4

Service Manual

Premium Compact W 160/4

Service Manual

S

SK 19

Service Manual

SM 10

Operator’s Manual

SM 15

Operator’s Manual

SM 7.5

Operator’s Manual

SM 8

Service Manual

(Ocr-Read Summary of Contents of some pages of the KAESER M43 Document (Main Content), UPD: 08 February 2023)

  • 137, KAESER M43 11 Spares, Operating Materials, Service 11.5 Spares for service and repair No.: 9_9432 02 E Service Manual Screw Compressor M43 127 RAMIRENT

  • 192, 11 Spares, Operating Materials, Service 11.5 Spares for service and repair 182 Service Manual Screw Compressor M43 No.: 9_9432 02 E RAMIRENT

  • 97, 3. If the machine is to be unused for a number of weeks, remove the battery and store in a frost proof room. In extreme cases, the use of heavy-duty cold-start batteries (to DIN 75311) and/or additional batteries is recommended. 10.3.6.3 Battery removal and installation Precondition The machine is shut down. The machine is standing level. The machine is fully vented, the pressure gauge reads 0 bar. Machine cooled down. 1. WARNING! There is danger of batteries b…

  • 88, Bleeding the fuel system The electric fuel pump is used to bleed the system. The negative battery terminal must be connec‐ ted for the pump to operate and bleeding to be carried out. When the starter switch is turned to the «II» position, the pump starts and bleeds the fuel system. The engine is not started! Air can find its way into the fuel system under certain conditions or maintenance tasks: ■ Fuel tank empty. ■ Replacing the filter element/cartridge of: ─ Fuel p…

  • 170, KAESER M43 11 Spares, Operating Materials, Service 11.5 Spares for service and repair 160 Service Manual Screw Compressor M43 No.: 9_9432 02 E RAMIRENT

  • 73, Possible cause Action Where can I get help? Special‐ ised work‐ shop KAESER Service Engine service manual Oil pressure switch sensing in‐ sufficient oil pressure. Check the engine oil level. – – X Have the engine repaired or ex‐ changed. X – – Tab. 46 Alarm: Engine refuses to start or comes to a stop. 9.2.2 Engine does not reach full speed. Possible cause Action Where can I get help? Special‐ ised work‐ shop KAESER Service Engine ser…

  • 58, 2. If necessary, use a metal rod to adjust until the hole is flush with the sleeve 3 . 3. Push the ball coupling 5 on to the towbar 6 . 4. Check the alignment of the holes in the towbar tube 6 and coupling 5 . 5. Push the fixing bolts 2 through the holes in the coupling 5 and towbar tube 6 . 6. Screw on and tighten the self-locking nuts 4 . 6.3.3.4 Option se Changing a fixed height towbar with overrun brake from e…

  • 222, 13 Annex 13.3 Dimensional drawings 212 Service Manual Screw Compressor M43 No.: 9_9432 02 E RAMIRENT

  • 194, 11 Spares, Operating Materials, Service 11.5 Spares for service and repair 184 Service Manual Screw Compressor M43 No.: 9_9432 02 E RAMIRENT

  • 112, 10.6 Maintain rubber sealing strips The rubber sealing strips between the lower body and the canopy serve both as a soundproofing measure and to prevent ingress of rain water. Care of the rubber sealing strips is very necessary during the winter months to prevent the strips from sticking and tearing when the canopy is opened. ➤ Lubricate the rubber sealing strips regularly with silicone oil or Vaseline. 10.7 Options ➤ Carry out maintena…

  • 117, KAESER M43 3. Check if the interior of the shut-off valve 4 is clean. Blow out any dirt with compressed air. The valve cannot be completely cleaned with a compressed air blast. ➤ Remove the engine air intake shut-off valve, noting its mounted position. ➤ Clean the valve with cleaning fluid or spirit and allow to dry. ➤ Refit the valve. Check the engine air intake shut-off valve for correct function and movement 1. Check the valve for signs of excessive wear…

  • 90, Fig. 27 Fuel filter with water trap 1 Filter head 2 Filter element 3 Water trap 4 Drain plug Checking the water trap The water trap is semi-transparent so the fuel level can be seen from outside. ■ Water, being denser than diesel fuel, sinks to the bottom of the water trap. ■ The presence of water can be verified by its different colour to the fuel. A check should be made daily as to whether water and dirt has accumulated. …

  • 200, 11 Spares, Operating Materials, Service 11.5 Spares for service and repair 190 Service Manual Screw Compressor M43 No.: 9_9432 02 E RAMIRENT

  • 32, 3.8 In Emergency 3.8.1 Correct fire fighting Suitable extinguishing agents: ■ Foam ■ Carbon dioxide ■ Sand or earth Unsuitable extinguishing agents: ■ Strong jet of water 1. Keep calm. 2. Give the alarm. 3. Shut down the machine from the instrument panel if possible. 4. Move to safety. ■ Warn persons in danger. ■ Help incapacitated persons. ■ close the doors. 5. Try to extinguish the fire if you have the skill to do so. 3.8.2 Contact with operating materials The following ope…

  • 110, 10.5.2 Towbar maintenance Clean and lubricate all sliding and rotating bearings as necessary but at least every 6 months. Material Lithium enriched multi-purpose grease Non-corroding oil Cleaning rags Precondition The machine is shut down. The machine is disconnected from the towing vehicle and safely parked. 1. Check the towbar for correct function and movement. Make sure the coupling is fully locked. 2. Clean and oil all sliding and rotating beari…

  • 219, 13.3 Dimensional drawings 13.3.1 Option sa Dimensional drawing — chassis with height-adjustable tow bar 13 Annex 13.3 Dimensional drawings No.: 9_9432 02 E Service Manual Screw Compressor M43 209 RAMIRENT

  • 171, 11 Spares, Operating Materials, Service 11.5 Spares for service and repair No.: 9_9432 02 E Service Manual Screw Compressor M43 161 RAMIRENT

  • 43, KAESER M43 CAUTION Danger of short circuit Damage to the machine electrics is possible. ➤ Use the «battery isolating switch» only when the machine is at standstill. ➤ Do not use the «battery isolating switch» as a main or emergency switch. Fig. 8 Battery isolating switch 1 «Battery isolating switch» 2 Lifting eye Further information See 8.2 for operating the battery isolating switch. 4.6.5 Option ne Fuel filter with water trap Dies…

Table of Contents for KAESER SK 19:

  • Initial Start 7 — 2 3 — During installation of the compressor unit, ensure that a distance of at least 40 ”is kept between the cooling air intake of the unit and any wall.  Check the oil level in the oil separator tank (see chapter 9.12). — Check that the airend rotates in the correct direction (see chapter 7.4).  Check the tension of the drive belts (see chapter 9.4).  The ball valve (6.6, see chapter 5.3) must be c

  • Operation 8 — 3 1 8Operation 8.1 Control Panel 1 2 1 SIGMA CONTROL 2 EMERGENCYSTOP pushbutton 8.2 SIGMA controller The SIGMA controller (1) is fitted in the control cabinet in the compressor package and serves as the control panel. It has 11 keys and 9 LEDs. Operation of the compressor pack- age is determined by the settings programmed into the controller. Further details on individual function keys, LEDs and plain text display relating to possible alarms and service messages, display of events, etc. are given in the service manual sup- plied for the SIGM

  • Initial Start 7 — 2 5 7.4 Direction of Rotation Check The compressor is wired for connection to a clockwise phase se- quence power supply. A check of the direction of rotation can be made by testing the phase sequence. Arrows showing the direction of rotation are located on the motor and on the airend hous- ing.  On your initial start, ”bump” the unit and verify the direction of rotation. If the direction of rotation is incorrect, change over the supply conductors L1 and L2. If the aire

  • Transport 4 — 13 4.3 Storage If the equipment is to stand idle for a long period the prescribed measures must be taken to avoid damage. If any measures can not be taken, advice should be sought from an authorized KAESER distribitor. Basically, the equipment should be stored in a dry, frost—free room. Protect against ingress of moisture or formation of condensation. See chapter 7.8 for instructions on start—up. Storage up to 6 months (temporarily out of

  • Transport 4 — 12 4 Transport 4.1 Transport Instructions We recommend a fork lift truck or lifting equipment for transporting the compressor pack- age to avoid damage to the cabinet and framework. min. 40” Do not exert any side forces on the compressor package when trans- porting with lifting equipment! 4.2 Packaging Always observe the instructions in chapter 4.3 when packaging the machine for storage. Use packaging suitable for the intended route if the machine is to be transported further by the customer. Overland The machine should be protected from mechanical d

  • Initial Start 7 — 2 7 1 2 3 4 1 Motor overload (rated power supply) 2 Motor overload (alternative power supply) 3 Reset button 4 Motor overload adjustment 7.6 Setting the Air System Pressure The air system pressure is preset at the factory. It can be changed in SIGMA CONTROL to match customer’s operational requirements if the password is known. For further details, consult the SIGMA CONTROL service manual. Switching from full load to idle running may take place no more fre- quently than 2 time

  • Initial Start 7 — 2 6 7.5 Motor Overload Relay Adjustment and Changing Lock the main disconnect in the “off” position in accordance with ap- plicable lock out/tag out procedures (example: OSHA CFR 29 § 910.147) to ensure that the compressor does not restart. See chap- ter 2.3 for the main disconnect switch. The power supply voltage (see circuit diagram) must be fitted and con- nected with the compatible motor overload relay, and the set point must be adjusted. The relay is set to the standard adjustment at the factory. Compressor motor: Wye—delta start Over

  • Construction and Operation 5 — 1 9 — If the air systems pressure rises to the upper switching point and the running period has already expired, the compressor package is switched off after the run—on period has expired (2). — If the air systems pressure rises to the upper switching point before the running period has expired then the pressure decay time of the previous switching cycle is taken as the criterium for the selection of the operating mode: — If the pressure decay time t p decay was longer than

  • Maintenance 9 — 5 5 Perform a test run When the operating temperature is reached (see chapter 1.1), shut down the compressor package (see chapter 8.3) and lock the main disconnect in the ”off” position in accordance with applicable lock out/ tag out procedures (example: OSHA CFR 29 § 1910.147) to ensure the compressor does not restart. Afterwards, carry out a visual check for leaks. 9.15 Changing the Oil Separator Cartridge The service life of the oil separator cartridge is strongly influenced by the degree of conta- mination of inlet air and o

  • Maintenance 9 — 4 8  Venting the compressor package (see chapter 9.10). 8 7 9 10 B A 11 3 1 2 4 5 6 1 Ball valve 4 Filler plug 8 Maximum oil level A shut (oil top — up) 9 Ball valve — oil drain B open 5 Oil separator tank 10 Oil drain hose 2 Pressure gauge 6 Nozzle 11 External pressurization 3 Hose coupling 7 Minimum oil level  Unscrew the oil filler plug (4) on the oil separator tank.  Top off the oi

  • Operation 8 — 3 8 Possible cause: Remedy: Oil separator cartridge mountings are loose. Tighten mounting bolts. Oil level in separator tank is too high. Drain oil to correct level. Scavenger line is clogged. Inspect dirt trap strainer in scavenger line. Clean or replace clogged parts as necessary.

  • Installation 6 — 2 0 6 Installation 6.1 Installation Requirements The compressor should be mounted on level surface. For any special application please consult with the manufacturer. Safe operation of the compressor package is only ensured if the ambient temperature re- mains within the limits stated in chapter 1.6). If the compressor is used in the open, take care that it is protected against the direct rays of the sun and against the ingress of dust and rain. Install the c

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of KAESER SK 19 device using right now.

Реклама на портале

ЭйрТехник

  • Ответить с цитатой

Мануал для KAISER .

Всем доброго дня!
Имеем в обслуживание компрессор KAISER, к сожалению не профильное наше оборудование, нет инструкции для контроллера и кодов доступа для сброса сервиса. Ранее кем-то компрессор обслуживался, а может и нет, и тоже сервис не сброшен, походу сначала его жизни. Может у кого есть инструкция. Фото прилагаю.

Ведущий специалист
 
Сообщений: 129
Зарегистрирован: 28 июн 2013, 06:22

  • Ответить с цитатой

Re: Мануал для KAISER .

Сообщение Android13 » 23 июл 2019, 17:15

Всегда занимайся самообразованием, научись учиться.
89037913622

Авторитетный компрессорщик
 
Сообщений: 444
Зарегистрирован: 11 янв 2013, 20:14
Откуда: Г. Москва
Откуда (город): Г. Москва
  • Сайт



Вернуться в Обмен, помощь в поиске ГОСТов, ОСТов, регламентов и инструкций: скачать бесплатно

Перейти:

Кто сейчас на форуме:

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 1

Реклама на портале

Report abuse

Libble takes abuse of its services very seriously. We’re committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we’ll investigate it and take the appropriate action. We’ll get back to you only if we require additional details or have more information to share.

Product:

Get your user manual by e-mail

Enter your email address to receive the manual of Kaeser M26 in the language / languages: Dutch as an attachment in your email.

The manual is 9,95 mb in size.

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

Понравилась статья? Поделить с друзьями:
  • Галерия мелонелла инструкция по применению отзывы
  • Октолипен инструкция по применению цена таблетки 300 мг взрослым отзывы
  • Инструкция для часов g shock на русском ga100
  • Руководство роспотребнадзора по орловской области
  • Пак стрелец мониторинг инструкция по эксплуатации