POSDION REXTAR X Operation & Service Manual

  1. Manuals
  2. Brands
  3. POSDION Manuals
  4. Dental equipment
  5. REXTAR X
  6. Operation & service manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

POSDION Co., Ltd.

Room 905, B-dong, Awish-Yedain Building, 452, Yangcheon-ro, Gangseo-gu, Seoul, 07574, Korea

Tel : +82-2-3664-2874,

Fax : +82-2-3661-2267

Home

E-mail: info@posdion.com

Distributed in the USA by: GoodDrs USA

17609 Ventura Blvd. #110

Encino, CA 91316 Toll Free (844)-448-5050

loading

Summary of Contents for POSDION REXTAR X

  • Page 1
    OPERATION & SERVICE MANUAL POSDION Co., Ltd. Room 905, B-dong, Awish-Yedain Building, 452, Yangcheon-ro, Gangseo-gu, Seoul, 07574, Korea Tel : +82-2-3664-2874, Fax : +82-2-3661-2267 Http://www.posdion.com E-mail: info@posdion.com Distributed in the USA by: GoodDrs USA 17609 Ventura Blvd. #110 Encino, CA 91316 Toll Free (844)-448-5050…
  • Page 2
    (This page intentionally left blank)
  • Page 3
    Requirements for after sales service If a malfunction or fault occurs, stop using the unit immediately, and check against the related article in this operation & service manual. Posdion Co.,Ltd. is not responsible for indirect harm caused by the unit. Posdion Co.,Ltd. cannot warrant for defect or harm after the warranty period.
  • Page 5
    POSDION Co., Ltd. TABLE OF CONTENTS *Note Updated Safety Unlock Procedure………………..28 Part I. OPERATION MANUAL ………………….1 1. Basic Instructions ……………………….3 2. Notes to the User ……………………….6 3. Storage and Operation conditions ………………….11 4. Caution : Radioactivity ……………………..12 5.
  • Page 6
    (This page intentionally left blank)
  • Page 7
    POSDION Co., Ltd. Explanation of symbols Refer to instruction manual/ booklet General warning sign Radiation exposure symbol used on operator console. Lights to indicate that an exposure is in progress. This is accompanied by an audible tone from the console…
  • Page 8
    POSDION Co., Ltd. Manufactured Date Manufacturer’s address European representative Serial number Symbol for temperature limitation ON/OFF (POWER) Page:2 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 9
    1. Basic Instructions 1) Outline REXTAR-X is one of the POSDION battery-powered portable dental series. REXTAR-X is the smallest and most lightweight, yet the most powerful High-Frequency X-ray device on the portable devices market. All X-ray devices in the battery-powered portable devices series are Ripple-free HF- type X-ray generating devices.
  • Page 10
    POSDION Co., Ltd. does not accept liability for casualties or losses arising from misuse or abuse of the REXTAR-X portable X-ray unit. Additional questions concerning safety or miscellaneous matters should be referred to the POSDION Co., Ltd. Service Team or to the regional retailer or distributor.
  • Page 11
    POSDION Co., Ltd. 5) Caution and Warning Signs Latent hazards may arise through improper use of X-ray devices. Such hazards are noted by warning notices as shown below concerning crucial safety and prevention measures ※ Information ※ The Operation Manual details operation procedures for the safe and efficient use of the REXTAR-X product for X-ray technicians, radiation technician, and other medical institutions using the REXTAR-X X-ray unit.
  • Page 12
    REXTAR-X may not be altered or manipulated at the discretion of the individual. In the case that such changes cannot be avoided, all inquiries must be directed to the POSDION Co., Ltd. Service Team, or to a retail center licensed for service.
  • Page 13
    Throwing, taking apart, or having external push are applied to batteries increases the risk of bodily harm, as well as of fire and explosion. Using batteries not approved by POSDION Co., Ltd. with this device increases the risk of fire and explosion.
  • Page 14
    POSDION Co., Ltd. 4) Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability.
  • Page 15
    POSDION Co., Ltd. a. Conducted Emission The AMN placed 0,8 m from the boundary of the unit under test and bonded to a ground reference plane. This distance was between the closest points of the AMN and the EUT. All other units of the EUT and associated equipment were at least 0,8 m from the AMN. All power was connected to the system through Artificial Mains Network (AMN).
  • Page 16
    POSDION Co., Ltd. j. Magnetic Field Immunity Measurements were made on a ground plane that extends 1-meter minimum beyond sides of the system under test. Tabletop EUT is located 80cm above the reference ground plane and floor-standing EUT is located 10cm above the reference ground plane. The indicated field was pre-calibrated prior to placement of the EUT under test.
  • Page 17
    POSDION Co., Ltd. 3. Storage and Operation conditions 1) Storage This device must NOT be stored: ◈ In direct light. ◈ In overly dusty environments. ◈ In high humidity. ◈ In poor ventilation. ◈ In highly saline environments. ◈ With chemicals or gases.
  • Page 18
    POSDION Co., Ltd. 4. Caution: CAUTION※ ※ Ionizing radiation may pose a significant hazard to both the patient and the operator if safety rules are not strictly followed 1) The user and/or the operator must be wearing the appropriate clothing and safety devices.
  • Page 19
    POSDION Co., Ltd. 5. Parts and Components REXTAR-X is an X-ray device for medical use. This device may be applied to diagnostic purposes, and must be operated by a licensed dentist. The user must follow health and safety regulations relating to electric and chemical safety, and the safeguarding of medical equipment with ionizing potential.
  • Page 20
    POSDION Co., Ltd. 6. Specifications Classifications : Type of protection against electric shock : Class II / Internally Powered Equipment Degree of protection against electric shock : Type B Applied part Degree of protection against the ingress of water : IPX0…
  • Page 21
    POSDION Co., Ltd. Items Specifications Tube Inherent Filtration 1.0mmAL Eq. Total Addition Filtration 0.5mmAL filteration Total 1.5mm AL Eq. @ 70 kV Size 146×155×139mm 2 kg Weight (main body+built-in Battery) < Table1.6.1.1 Device Specification > * Back-Scatter Shield is 12mm thick, x 6″ in diameter and has a lead equivalence of 0.5 or greater mmPb…
  • Page 22
    POSDION Co., Ltd. 2) Measurement of Main body and components (1) Main body < Pic1.6.2.1 Main body> Page:16 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 23
    POSDION Co., Ltd. (2) Carrying bag < Pic1.6.2.2 Carrying bag> (3) Packing BOX < Pic1.6.2.3 Packing BOX > REXTAR-X Manual PN# 100304-00 Rev.02 Page:17…
  • Page 24
    POSDION Co., Ltd. (4) Short Cone 1 ( 40mm ) Long Cone 2 ( 140mm ) (For Export outside of the USA) (For Sale with-in the USA or as requested) < Pic1.6.2.4 Cone1 (40mm) > < Pic1.6.2.5 Cone2 (140mm) >…
  • Page 25
    POSDION Co., Ltd. 3) X-ray Tube Specification (1) Basic Specification Model name(Manufactured by) : D – 041 ( TOSHIBA ) Voltage Range (Maximum Voltage) : 50 ~ 70kV ( 77kV ) Focal Spot Size : 0.4 × 0.4mm Input Electrical Power (per second) : 430W…
  • Page 26
    POSDION Co., Ltd. 7. Name of Each parts 1) Main body Power ON/OFF Button (2) Hand strap Exposure time decrease Button (3) X-RAY Exposure Exposure time Button increase Button 140mm Cone Must remain in place Lead/Acrylic Anti- back scatter shield…
  • Page 27
    POSDION Co., Ltd. (1) POWER ON Button Power Of/ Off button . Turned on when you push in OFF state, and turned off when you push in ON state. (2) Hand Strap Used for easy operation when you hold REXTAR-X.
  • Page 28
    POSDION Co., Ltd. (13) Battery Pack Cover Cover for battery attach/detach. Battery cannot be disassembled or separated at your discretion. (14) Charger connection terminal Charger plug terminal for battery charging. Only enclosed charger should be used. (15) Hand switch connection terminal Terminal for connect with hand switch.
  • Page 29
    POSDION Co., Ltd. 2) Label (1) Model name label (2) Main Label < Pic1.7.2.2 Main body Label – bottom> REXTAR-X Manual PN# 100304-00 Rev.02 Page:23…
  • Page 30
    POSDION Co., Ltd. (3) Tank Label < Pic1.7.2.3 TANK Label – bottom> Page:24 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 31
    POSDION Co., Ltd. 8. Operation 1) Prepare for Operation (1) Lead aprons must be worn by patients during Exposure. (2) In order to minimize the time required per session and gain the best results, the device must be kept from being shaken or otherwise disturbed when pressing the exposure button.
  • Page 32
    POSDION Co., Ltd. 2) Pre-Heating (1) Outline All portable X-RAY devices require preliminary preparatory measures such as written below. Pre-heating is a necessary step to protect the X-RAY tube from a sudden increase in electric current flow, and for the safe continued use of the device.
  • Page 33
    POSDION Co., Ltd. 9. Operating Instructions 1) REXTAR-X POWER ON/OFF Push and hold the power button for 3 seconds to turn ON the power. And the power may turned OFF by the same way as above. When power turned ON, Firmware version displays on the LCD panel as below.
  • Page 34
    POSDION Co., Ltd. 2) Exposure time control Exposure time control is available by push the increase/decrease buttons. However, in charging state or during X-ray exposure not available to control time. Exposure control time is 0.01 ~ 1.30 sec ( 43 Step ).
  • Page 35
    POSDION Co., Ltd. 3) X-ray Exposure Operation Instruction ※ NOTICE ※ X-ray exposure is controllable with one button. Keep depressed til the x -ray emission light goes out and the beep sound stops. (1) Prepare the X-ray exposure By pushing Exposure Button, you can start X-RAY Exposure.
  • Page 36
    POSDION Co., Ltd. (2) Ready to X-ray Exposure < Time to complete preparations: 2 seconds > After ‘(1) Prepare the X-ray exposure’, The READY indicator lights up on LCD panel. < Pic1.9.3.2 Ready to X-ray> (3) X-ray Exposure ※ NOTE※…
  • Page 37
    POSDION Co., Ltd. (5) Stand-by Complete ※ NOTE※ In order to protect the X-RAY tube, the Exposure button must be released after each Exposure conducted to allow the next Exposure conduct. During standby, the Exposure button must be released. Standby will only be concluded once the Exposure button is released.
  • Page 38
    POSDION Co., Ltd. 5) How to set APR function (1) Start to APR function SETTING MODE Push the APR MODE Switch button longer than 3 seconds what you want to set among four APR mode Switch buttons on the REXTAR-X.
  • Page 39
    POSDION Co., Ltd. (3) APR function SETTING (APR human size selection) This switch button is for selection between adult and child. If you push the switch button, the pictures of adult and child will be changed. Selected human size will be appeared on the LCD.
  • Page 40
    To operate REXTAR-X, you can hold “Hand Strap’ of device with one hand, and you can manipulate Exposure time control button with another hand. At only 2mA, the Rextar X is extremely low dose and we recommend having the end of the cone as close to the receptor as possible.
  • Page 41
    POSDION Co., Ltd. 10. How to use Battery 1) How to attach/detach Battery ※ NOTE※ Batteries should only be detached when being replaced. Overly frequent detachment causes reduced battery life. **When detaching the battery cover, the 2.6 PIE six-sided bolts affixing the cover must also be removed.
  • Page 42
    POSDION Co., Ltd. 2) Charging Batteries To charge batteries, connect the Battery Charger to the Battery Charger Connection Terminal. Battery Charger can be directly connected to the Battery Charger Connection Terminal. (International export plug shown) (1) AC/DC Adaptor < Pic 1.10.2.2 AC Plug >…
  • Page 43
    POSDION Co., Ltd. 3) Charging Precautions Charge was 1.5 m of outside the Patient Environment to Medically used room. ※ Caution ※ 1.5m-access areas outside the charge to the patient. 4) Battery Use Cycles Batteries wear down with use. Old batteries must be recharged more often. When the length of time a battery could function after each charging has shrunk to half or less compared to when the battery was new, it is time to replace the battery.
  • Page 44
    *Zone of Significant Occupancy Rextar X requires the presence of an operator, with at least one significant zone of occupancy with a floor not smaller than 60 × 60 cm wide, and not shorter than 200 cm height, including the logical information as follow.
  • Page 45
    — the operator remains within the Significant Zone of Occupancy immediately behind the device shield. Incorrect placement Correct placement Rextar X Do not enable until patient and operator are positioned and ready for the exposure, reducing the likelihood of interruption and preventing inadvertent exposure of anyone to x-rays.
  • Page 46
    10) As shown in the table below, maximum protection (white area) from backscatter radiation (red area) exists when the Rextar X is positioned near the patient, is perpendicular to the operator (with the patient’s head tilted if needed), and the backscatter shield is fully extended toward the patient and parallel to the operator.
  • Page 47
    50 mSv Average Exposure Using Rextar X with D — Speed Film 0.40 mSv Average Exposure Using Rextar X with F — Speed Film or Digital 0.20 mSv Sensor 1) Standards for Protection against Radiation, 10 CFR 20 (US Federal Standards), 1994 (see also NCRP Report No. 116) 2) Normalized average (includes leakage and backscatter radiation) assumes 7,200 exposures per year, and the average length of exposure for E-speed Film = 0.20 seconds, digital sensor = 0.10 seconds…
  • Page 48
    Controls are not waterproof.) 3) Rextar X and the accompanying battery charger are not designed to be subjected by any kind of sterilization procedure. Rextar X is not designed to be sterilized.
  • Page 49
    2.7 Storage and Transportation • Store the unit in a place which is not affected by air pressure, temperature (cool), humidity (dry), ventilation, sunlight, dust, salt, sulfur, etc. for long term storage. Please be careful not to drop or hit the device during storage or transportation. •…
  • Page 50
    5) Use only the power cables, software, and miscellaneous accessories developed and distributed by POSDION Co., Ltd. 6) POSDION Co., Ltd. will not accept liability for third-party or patient claims. 7) Store this manual near the REXTAR-X device, in an easy-to-find place Page:38 Rev.02…
  • Page 51
    POSDION Co., Ltd. 2. Regular Maintenance 1) Introduction The REXTAR- X-ray unit is designed for a service life of 7 years. The performance of the batteries however may decline during the lifetime, depending on the number and time of the charging cycles.
  • Page 52
    POSDION Co., Ltd. 3. Block diagram Page:40 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 53
    Re-start from Power on and Keep pushing X-ray exposure button until Exposure setting time for enough exposure. If the same error occurs, enquire with the POSDION Co., Ltd. Service Team, or to a retail center licensed for service ※ CAUTION※…
  • Page 54
    POSDION Co., Ltd. 5. Circuit Diagrams For Authorized Service and Test Technicians Page:42 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 55
    POSDION Co., Ltd. For Authorized Service and Test Technicians REXTAR-X Manual PN# 100304-00 Rev.02 Page:43…
  • Page 56
    POSDION Co., Ltd. For Authorized Service and Test Technicians Page:44 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 57
    POSDION Co., Ltd. For Authorized Service and Test Technicians REXTAR-X Manual PN# 100304-00 Rev.02 Page:45…
  • Page 58
    POSDION Co., Ltd. For Authorized Service and Test Technicians Page:46 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 59
    POSDION Co., Ltd. For Authorized Service and Test Technicians REXTAR-X Manual PN# 100304-00 Rev.02 Page:47…
  • Page 60
    POSDION Co., Ltd. For Authorized Service and Test Technicians Page:48 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 61
    POSDION Co., Ltd. For Authorized Service and Test Technicians REXTAR-X Manual PN# 100304-00 Rev.02 Page:49…
  • Page 62
    POSDION Co., Ltd. For Authorized Service and Test Technicians Page:50 Rev.02 PN# 100304-00 REXTAR-X Manual…
  • Page 63
    POSDION Co., Ltd. (This page intentionally left blank) REXTAR-X Manual PN# 100304-00 Rev.02 Page:51…
  • Page 64
    POSDION Co., Ltd. For Authorized Service and Test Technicians 1. Basic Instruction 1) Outline When there is a change in X-ray output in initial use or during use, you can control output value with Calibration. ※ WARNING※ Always keep in mind that calibration must be handled by a…
  • Page 65
    For Authorized Service and Test Technicians POSDION Co., Ltd. — How to check Digital Oscilloscope : mA is fixed so 2mA will come out. — mA Feedback is calculated 1mA as 1V output. Therefore, 2V should come out in mA.
  • Page 66
    For Authorized Service and Test Technicians POSDION Co., Ltd. — How to calibrate mA when Filament is abnormal : Control Filament Preheat value with VR1 *DRV Baord — VR101 : Volume Resistor 200Ω < Pic3.1.3.4 Filament calibration Volume Resistor location>…
  • Page 67
    For Authorized Service and Test Technicians POSDION Co., Ltd. — Notice for Calibration Below table is normal mA output waveform after control completion. As Filament preheat value is high, Overshoot also increases. Therefore, when you control it, you should Check Overshoot value and proceed Final control.
  • Page 68
    For Authorized Service and Test Technicians POSDION Co., Ltd. This form must be completed fully and submitted with any POSDION generator returned for warranty considerations or repair requests. A. GENERAL INFORMATION 1) Product Name : 2) Serial Number : 3) Date Received :…
  • Page 69
    POSDION Co., Ltd. Distributed by POSDION Co., Ltd. Room 905, B-dong, Awish-Yedain Building, 452, Yangcheon-ro, Gangseo-gu, Seoul, 07574, Korea Tel : 82–02–3664–2874, Fax : 82–2–3661–2267 Http://www.posdion.com E-mail: info@posdion.com Manufactured by ISO 13485 CERTIFIED COMPANY Distributed in the USA by: GoodDrs USA 17609 Ventura Blvd.
  • Page 70
    Rextar X Operator Safety and Training Course Test Name: Date: Results: Passed Failed A Parent must wear a lead apron if they stay in the room when X-rays are taken of their child. True False How is the unit locked and secured when not in use?
  • Page 71
    What type of disinfectant should you use to clean the device? Non-acetone and non-alcohol disinfectant wipes Xylene Rubbing alcohol The correct way to hold the device is with one hand on the cone. True False How would you change the radiology settings from adult to child? a.
  • Page 72
    Required exposure times typically differ from film to sensor. True False The Posdion Rextar -X should be inspected at least once per year by a qualified technician. True b. False What is the source to skin distance in accordance with FDA regulations?
  • Page 73
    Does your state department have any restrictions for a handheld x-ray device? How do you register the Rextar X with the state department? Call the state department and let them know you have the Rextar X. Send a letter to the state health department on our letterhead and state that you have the Rextar X.
  • Page 74
    13 Operator Training Test Answers 1. A 2. C 3. B 4. C 5. A 6. A 7. B 8. A 9. C 10. A 11. C 12. B 13. A 14. A 15. A 16. A or B – depends on each state’s regulation 17.
  • Page 75
    Rextar X Operator Training Course Th is Ac know le dge s that: Recipient’s Name HAS SUCCE SSF ULL Y COM P LE TE D THE Course Rextar X User Safety Your Business name or logo here Date SIGNED…

Рентген Rextar X — высокочастотный портативный дентальный рентген-аппарат.

Преимущества

1. Компактный и легкий
Удобно делать снимок одной рукой. Вес: 1.6 кг, один из самых лёгких рентген-аппаратов, легко держится в руке, отсутствуют дополнительные вибрации.

2. Автоматическая (программируемая) и ручная настройка времени экспозиции
Интеллектуальная система контроля времени экспозиции, позволяет запоминать нужные настройки времени экспозиции для обеспечения оптимальной контрастности и яркости снимка, а также получить быстрый доступ к запрограммированным настройкам.

3. Рентгеновская трубка: Toshiba D-041
Напряжение в трубке: 70kV/2mA
Более высокие технические характеристики по сравнению с конкурентами, при напряжении 70 кВ рентгеновские лучи лучше проникают в ткани, на датчик попадает больше информации. Наличие патента (оборудование запатентовано).

4. Фокальное пятно: 0.4 мм
На качество изображения влияет размер фокального пятна, а также угол расхождения лучей, чем они меньше, тем лучше изображение, сфокусированнее. У рентген-аппарата Rextar фокальное пятно равно 0.4 мм, а угол расхождения лучей 12 градусов.

5. Повышенная безопасность
Отличительной особенностью данного рентген аппарата является дополнительная защита от радиации: во время использования рентген аппарата Rextar нет необходимости применять отдельный защитный щит для обратного рассеивания, так как в корпусе аппарата уже предусмотрена двойная защита из свинцовых пластин. Такая надёжная защита обеспечивает полную безопасность от рассеиваемой радиации.

Аппарат может работать со всеми видами приемников

Цифровой сенсор, дентальная плёнка или фосфорная пластина.
Во всех случаях вы получите превосходное изображение.

Дозы получаемые при работе с аппаратом Rextar

При максимальном использовании
При времени экспозиции в 1,3 секунды и 60-ти снимков в день (примерно 15600 снимков/год) = за 1 год оператор получит 3,988 миллиЗивертов в год (допустимая доза по нормам для персонала группы «Б» 5,0 миллиЗивертов).

При реальном использовании
При времени экспозиции в 0,2 секунды и 10-ти снимков в день (примерно 2500 снимков/год) = за 1 год оператор получит 0,04 милиЗивертов (или 40 мкЗивертов).

Для сравнения

  • Трансатлантический перелет добавит вам 0,07 милиЗивертов (70 микроЗивертов).
  • Полет из Москвы во Владивосток — 0,03 милиЗиверта (30 мкЗв).
  • Примерные дозы радиации, получаемые от общего радиационного фона:
    в США — 6,2 милиЗиверта,
    в Великобретании — 2,7 милиЗиверта,
    в Корее — 1,6 милиЗиверта,
    т.е. cущественно больше, чем рассеянная радиация, которая получается при использовании аппарата Рекстар.
  • Средний радиационный фон по Москве — 0,09-0,20 мкЗв/час (9-20 мкР/час).
  • Средний радиационный фон в Московском метрополитене — 0,14-0,37 мкЗв/час (14-37 мкР/час).
  • Безопасный уровень радиационного фона — до 30 мкР/час.

Разрешенная допустимая доза  соответствии с СанПиН 2.6.1-1192-03

  • Для персонала группы А: 20 мЗв в год.
  • Для персонала группы Б: 5 мЗв в год.
  • Для населения: 1 мЗв в год.
  • *1 мЗв = 1000 мкЗв.

Инструкция к портативному рентгену Rextar (Инструкция_rextar.pdf, 3,852 Kb) [Скачать]

Протокол испытаний (Протокол_испытаний_rextar.pdf, 786 Kb) [Скачать]

Презентация (Презентация_rextar-ppt.pdf, 2,791 Kb) [Скачать]


Отзыв о портативном рентгене Rextar X


Отзыв о портативном рентгене Rextar X

Posdion

Описание товара:

Аппарат рентгеновский стоматологический интраоральный «Poskom» с принадлежностями, вариант исполнения Rextar X

Страна производитель

Южная Корея

Размер упаковки (ШхВхД) (см)

14,6х13,9х15,5

На ваш почтовый адрес отправлено письмо с файлом

Закрыть окно

Описание товара

Rextar X — высокочастотный портативный дентальный рентген | POSDION (Ю. Корея)

Преимущества:

  • Компактный и легкий
  • Удобно делать снимок одной рукой
  • Вес: 1.6 кг, самый легкий из всех существующих портативных аппаратов, рука не устает, отсутствуют дополнительные вибрации
  • Автоматическая (программируемая) и ручная настройка времени экспозиции
  • Интеллектуальная система контроля времени экспозиции, позволяет запоминать нужные настройки времени экспозиции для обеспечения оптимальной контрастности и яркости снимка, а также получить быстрый доступ к запрограммированным настройкам.
  • Рентгеновская трубка: Toshiba D-041
  • Напряжение в трубке: 70kV/2mA
  • Более высокие технические характеристики по сравнению с конкурентами, при напряжении 70 кВ рентгеновские лучи лучше проникают в ткани, на датчик попадает больше информации.
  • Наличие патента (оборудование запатентовано)
  • Фокальное пятно: 0.4 мм На качество изображения влияет размер фокального пятна, а также угол расхождения лучей, чем они меньше, тем лучше изображение, сфокусированнее. У рентген-аппарата Rextar фокальное пятно равно 0.4 мм, а угол расхождения лучей 12 градусов.

Отличительной особенностью данного аппарата является дополнительная защита от радиации: во время использования аппарата Rextar нет необходимости применять отдельный защитный щит для обратного рассеивания, так как в корпусе аппарата уже предусмотрена двойная защита из свинцовых пластин. Такая надёжная защита обеспечивает полную безопасность от рассеиваемой радиации.

Технические характеристики

  • Источник питания аппарата: 19 В постоянного тока; 3,16 А
  • Зарядное устройство: 100-240 В переменного тока; 50-60 Гц; 1,5 А
  • Источник питания изделия: 1,1 В постоянного тока (аккумуляторная батарея)
  • Аккумуляторная батарея: 11,1 В (полимерная ионно-литиевая батарея)
  • Рентгеновская трубка: Toshiba D-041
  • Фокальное пятно: 0.4×0.4 мм
  • Выходная мощность: 140 Вт
  • Частота: 70 кГц (высокочастотная)
  • Значение кВ/мА: Фиксированное 70 кВ / 2 мА
  • Время экспозиции: от 0,01 до 1,30 с (всего 43 уровня)
  • Максимальное отклонение параметров, кВ: ± 7%
  • Максимальное отклонение параметров, с: ± 10%
  • Внутренняя фильтрация: Минимум 1,0 мм AI
  • Дополнительная фильтрация трубки: 0,5 мм AI
  • Общая фильтрация: 1,5 мм при 70 кВ
  • Дисплей: ЖК-дисплей (4 символа высота 0,5 дюйма)
  • Размеры: 146×155×139 мм
  • Вес: 1,88 кг (корпус с установленным аккумулятором)

Высококачественный снимок и максимальная безопасность определяется следующими параметрами:

В рентгене используется рентген-трубка последней модели Toshiba D-041 (Япония), которая обеспечивает:

  • Напряжение 70 КВт – при минимальном времени экспозиции дает четкое изображение
  • Минимальное фокальное пятно 0,4 мм
  • Минимальный угол расхождения лучей 12 градусов
  • Последние два параметра дают очень узкий и направленный луч. Сравнение качества снимка при разных величинах фокального пятна и угла расхождения лучей.

Источник рентген излучения надежно защищен свинцовым корпусом. Аппарат высокочастотный, в комплекте с визиографом разрешен к использованию непосредственно в стоматологическом кабинете (при наличие ширмы и средств индивидуальной защиты врача и пациента). (Методические указания МУ 2.6.1.2043-06). Аппарат имеет самые высокие характеристики среди аналогов, что позволяет делать снимки самого высокого качества. Аппарат даёт чистое изображение дополнительных каналов и апикальной области. Аппарат может работать со всеми видами приемников: цифровой сенсор, дентальная плёнка или фосфорная пластина. Во всех случаях вы получите превосходное изображение.

Дополнительные преимущества портативного аппарата Rextar:

  • Легок и абсолютно мобилен (можно делать снимок одной рукой )
  • Информативная панель управления
  • Нет соединительных проводов
  • Простое и понятное управление
  • Одной зарядки хватает на сотни снимков

Дозы получаемые при работе с аппаратом Rextar:

При максимальном использовании

При времени экспозиции в 1,3 секунды и 60 -ти снимков в день (примерно 15600 снимков/год) = за 1 год оператор получит 3,988 миллиЗивертов в год (допустимая доза по нормам для персонала группы «Б» 5,0 миллиЗивертов)

При реальном использовании

При времени экспозиции в 0,2 секунды и 10 снимков в день (примерно 2500 снимков/год) = за 1 год оператор получит 0,04 миллиЗивертов (или 40 мкЗивертов)

Для сравнения:

  • Трансатлантический перелет добавит вам 0,07 миллиЗивертов (70 микроЗивертов)
  • Полет из Москвы во Владивосток  — 0,03 миллизиверта (30 мкЗв)
  • Примерные дозы радиации, получаемые от общего радиационного фона в таких странах как США (6,2 миллизиверта), в Великобритании (2,7 миллизиверта), Корея (1,6 миллизиверта) = Существенно больше, чем рассеянная радиация, которая получается при использовании аппарата Рекстар.
  • Средний радиационный фон по Москве      0,09-0,20 мкЗв/час (9-20 мкР/час)
  • Средний радиационный фон в Московском метрополитене      0,14-0,37 мкЗв/час (14-37 мкР/час)
  • Безопасный уровень радиационного фона     до 30 мкР/час
  • Разрешенная допустимая доза в соответствии с СанПиН 2.6.1-1192-03:
    • Для персонала группы А     20 мЗв в год
    • Для персонала группы Б     5 мЗв в год
    • Для населения     1 мЗв в год

 *1 мЗв = 1000 мкЗв

  • POSDION

  • Производитель:  POSDION
  • Состояние на складе:  Доступен для заказа
  • Код товара:  2172-AMF
  • Артикул RD-5392X

Доставка

Отправляем заказы от 1 дня при наличии товара на складе.
Доставляем по Москве
Санкт-Петербургу и Всей России

Гарантия качества

Все продаваемые товары имеют соответствующие документы.
Гарантия от производителя.
Сервисное обслуживание.

Онлайн 24/7

Заказы на сайте принимаются 24/7.
Тем не менее обрабатываются заявки в часы работы компании.

В связи с изменением курса ЕВРО и ДОЛЛАРА
цена может отличаться.
Уточняйте цену у менеджера

Характеристики

Технические характеристики

  • Время экспозиции (секунд)0
  • Максимальное анодное напряжение70
  • Размер фокального пятна (мм)0
  • Способ крепленияПортативный
  • Тип трубкиВысокочастотный
  • Страна производителяЮ. Корея

Описание

Преимущества:

  1. Компактный и легкий
  2. Удобно делать снимок одной рукой
  3. Вес: 1.6 кг, самый легкий из всех существующих портативных аппаратов, рука не устает, остутствуют дополнительные вибрации
  4. Автоматическая (программируемая) и ручная настройка времени экспозиции
  5. Интеллектуальная система контроля времени экспозиции, позволяет запоминать нужные настройки времени экспозиции для обеспечения оптимальной контрастности и яркости снимка, а также получить быстрый доступ к запрограммированным настройкам.
  6. Рентгеновская трубка: Toshiba D-041
  7. Напряжение в трубке: 70kV/2mA
  8. Более высокие технические характеристики по сравнению с конкурентами, при напряжении 70 кВ рентгеновские лучи лучше проникают в ткани, на датчик попадает больше информации.
  9. Наличие патента (оборудование запатентовано)
  10. Фокальное пятно: 0.4 мм На качество изображения влияет размер фокального пятна, а также угол расхождения лучей, чем они меньше, тем лучше изображение, сфокусированнее. У рентген-аппарата Rextar фокальное пятно равно 0.4 мм, а угол расхождения лучей 12 градусов.

Отличительной особенностью данного аппарата является дополнительная защита от радиации: во время использования аппарата Rextar нет необходимости применять отдельный защитный щит для обратного рассеивания, так как в корпусе аппарата уже предусмотрена двойная защита из свинцовых пластин. Такая надёжная защита обеспечивает полную безопасность от рассеиваемой радиации.

Конкуренты

Rextar

Технические характеристики:

  • Источник питания аппарата 19 В постоянного тока, 3,16 А
  • Зарядное устройство 100-240 В переменного тока, 50-60 Гц, 1,5 А
  • Источник питания изделия 1,1 В постоянного тока (аккумуляторная батарея)
  • Аккумуляторная батарея 11,1 В (полимерная ионно-литиевая батарея)
  • Рентгеновская трубка Toshiba D-041
  • Фокальное пятно 0.40.4 мм
  • Выходная мощность 140 Вт
  • Частота 70 кГц (высокочастотная)
  • кВ, мА 70 кВ /2 мА (фиксированное значение)
  • Время экспозиции от 0,01 до 1,30 с (всего 43 уровня)
  • Максимальное отклонение параметров, кВ plusmn, 7%
  • Максимальное отклонение параметров, с plusmn, 10%
  • Внутренняя фильтрация Минимум 1,0 мм AI
  • Дополнительная фильтрация трубки 0,5 мм AI
  • Общая фильтрация 1,5 мм при 70 кВ
  • Дисплей ЖК-дисплей (4 символа высота 0,5 дюйма)
  • Размеры 146155139 мм
  • Вес 1,88 кг (корпус с установленным аккумулятором)

Высококачественный снимок и максимальная безопасность определяется следующими параметрами:

В рентгене используется рентген-трубка последней модели Toshiba D-041 (Япония), которая обеспечивает:

  1. Напряжение 70 КВт при минимальном времени экспозиции дает четкое изображение
  2. Минимальное фокальное пятно 0,4 мм
  3. Минимальный угол расхождения лучей 12 градусов
  4. Последние два параметра дают очень узкий и направленный луч. Сравнение качества снимка при разных величинах фокального пятна и угла расхождения лучей.

Источник рентген излучения надежно защищен свинцовым корпусом.

Аппарат высокочастотный, в комплекте с визиографом разрешен к использованию непосредственно в стоматологическом кабинете (при наличие ширмы и средств индивидуальной защиты врача и пациента). (Методические указания МУ 2.6.1.2043-06).

Аппарат имеет самые высокие характеристики среди аналогов, что позволяет делать снимки самого высокого качества. Аппарат даёт чистое изображение дополнительных каналов и апикальной области.

Параметры Rextar Все остальные модели
Фокальное пятно, мм 0,4 0,8
Напряжение, кВ 70 60 — 70
Угол расхождения лучей, градусы 12 24
Сила тока, мА 2 1-2
Время экспозиции на визиограф от 0,01 с от 0,01 с
Время экспозиции на пленку от 0,03 с от 0,03 с

Аппарат может работать со всеми видами приемников: цифровой сенсор, дентальная плёнка или фосфорная пластина. Во всех случаях вы получите превосходное изображение.

Дополнительные преимущества портативного аппарата Rextar:

Легок и абсолютно мобилен (можно делать снимок одной рукой )
Информативная панель управления
Нет соединительных проводов
Простое и понятное управление
Одной зарядки хватает на сотни снимков

Дозы получаемые при работе с аппаратом Rextar:

При максимальном использовании

При времени экспозиции в 1,3 секунды и 60 -ти снимков в день (примерно 15600 снимков/год) = за 1 год оператор получит 3,988 милли Зивертов в год (допустимая доза по нормам для персонала группы Б 5,0 милли Зивертов)

При реальном использовании

При времени экспозиции в 0,2 секунды и 10 снимков в день (примерно 2500 снимков/год) = за 1 год оператор получит 0,04 мили Зивертов (или 40 мк Зивертов)

Для сравнения:

  • Трансатлантический перелет добавит вам 0,07 мили Зивертов (70 микро Зивертов)
  • Полет из Москвы во Владивосток — 0,03 мили Зиверта (30 мкЗв)
  • Примерные дозы радиации, получаемые от общего радиационного фона в таких странах как США (6,2 милизиверта), в Великобретании (2,7 милизиверта), Корея (1,6 милизиверта) = Существенно больше, чем рассеянная радиация, которая получается при использовании аппарата Рекстар.
  • Средний радиационный фон по Москве 0,09-0,20 мкЗв/час (9-20 мкР/час)
  • Средний радиационный фон в Московском метрополитене 0,14-0,37 мкЗв/час (14-37 мкР/час)
  • Безопасный уровень радиационного фона до 30 мкР/час
  • Разрешенная допустимая доза в соответствии с СанПиН 2.6.1-1192-03:
    • Для персонала группы А 20 мЗв в год
    • Для персонала группы Б 5 мЗв в год
    • Для населения 1 мЗв в год

*1 мЗв = 1000 мкЗв

Инструкция по эксплуатации Rextar на русском языке (скачать)

Презентация портативного рентгена Rextar на русском языке (скачать)

Протокол радиационно-гигиенических испытаний аппарата Rextar (скачать)

Рекомендуемые

Технические характеристики
Время экспозиции (секунд) 0
Максимальное анодное напряжение 70
Размер фокального пятна (мм) 0
Способ крепления Портативный
Тип трубки Высокочастотный
Страна производителя Ю. Корея
  • Самовывоз в Санкт-Петербурге
  • Курьерская доставка 
  • Транспортными компаниями по Москве и России
  • Самовывоз или доставка заказов СДЭК

Подробная информация о доставке в Информация о доставке

  • Оплата наличными или картой при самовывозе в Санкт-Петербурге
  • Оплата наличными при курьерской доставке в Санкт-Петербурге
  • Безналичным переводом для юр. лиц
  • Оплата в отделении банка по счету

Подробная информация в Способы оплаты

Понравилась статья? Поделить с друзьями:
  • Bodo hookah кальян инструкция по сборке
  • Жалобы руководству на коллег
  • Гуарана в таблетках инструкция по применению
  • Бутылочки авент натурал инструкция по применению
  • Фигурин для похудения отзывы инструкция цена беларусь