Optris laser sight пирометр руководство

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

®

LaserSight

optris

¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯

Operators manual

loading

Related Manuals for optris LaserSight

Summary of Contents for optris LaserSight

  • Page 1
    ® LaserSight optris ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ Operators manual…
  • Page 3
    Internet: www.optris.com hard case operators manual You will find the serial number on the unit. Always use this number when you contact the customer service concerning maintenance, additional order of components, spare parts or repairs. optris LS – E2006-01-A…
  • Page 4
    ® Thank you for choosing the optris LaserSight infrared thermometer. Comments on this manual Read the manual carefully before the initial start-up. The producer reserves the right to change the herein described specifications in case of technical advance of the product.
  • Page 5: Table Of Contents

    Setup Menu 2 Factory Default Setting Temperature Unit Troubleshooting Buzzer Maintenance Flip-Display Principle of Operation Ambient Temperature Compensation Emissivity Reset Appendix A – Emissivity Table Metals Data Logger Appendix B – Emissivity Table Non Metals Storing Data optris LS – E2006-01-A…

  • Page 6: Basic Operation

    Your new LaserSight is already equipped with batteries, which are protected with a plastic strip against discharge during the transport (please remove). If the batteries are low the battery symbol will appear in the display.

  • Page 7: Display

    Lower display: HOLD, emissivity, probe temperature, Tamb-value, material and location name Assignment of buttons: Mode I I , Mode II II , Up Λ and Down V Bar graph display Up and Down buttons Mode buttons optris LS – E2006-01-A…

  • Page 8: Measurement

    [2] are turned by 180° [► Flip-Display]. Please note, that at vertical use (Flip mode) in context with a switched display also the assignment of the Mode buttons (I and II) will change. optris LS – E2006-01-A…

  • Page 9: Measurement Functions

    After taking a measurement the following functions can be displayed in turn by pressing the Λ -button (starting from the HOLD mode): Maximum reading [MAX] Minimum reading [MIN] Average reading [AVG] Difference reading [DIF] optris LS – E2006-01-A…

  • Page 10: Display Backlight

    Laser Sighting then Pull the Trigger (keep it pressed) and the II -button to activate/ deactivate the laser. The laser symbol in the display (only if the trigger is pulled) indicates the active laser. Default setting: optris LS – E2006-01-A…

  • Page 11: Optics

    (Diameter: 1mm). To switch between SF and CF mode please shift the Optic switch which is located beside the display, to the corresponding position (see right figure). optris LS – E2006-01-A…

  • Page 12
    D = Distance from front of the unit to the object S = Spotsize depends on the distance. For a correct measurement the spot size should have at least the same size like the object or should be smaller than that at all times. optris LS – E2006-01-A…
  • Page 13: Setup Menu 1

    It can range between 0 and 1 (0 and 100 %) [► Emissivity]. Setting range: 0,100…1,100 (values > 1,000 = amplification) Default setting: 0,950 HOLD⇒ II ⇒ε flashes⇒ Λ ⇒ ε INCREASE ⇒ V ⇒ ε DECREASE optris LS – E2006-01-A…

  • Page 14: High Alarm

    [► Buzzer] will be generated: Setting range: -35…900°C Default setting: -35°C HOLD⇒ II ⇒2x I ⇒L flashes ⇒ Λ ⇒ INCREASE ALUE ⇒ V ⇒ DECREASE ALUE ⇒ II ⇒A ⇒alarm symbol [beside L] on/ off CTIVATION EACTIVATION optris LS – E2006-01-A…

  • Page 15: Long-Term Measurement (Lock Mode)

    You can deactivate the Lock function in the same order, but starting from Measurement mode+Lock. The data logger functions are also available in the Lock mode [► Data Logger]. For a long-term temperature measurement of an object it is recommended to mount the unit on a tripod. optris LS – E2006-01-A…

  • Page 16: Setup Menu 2

    With this function you can switch the temperature unit in the display between °C und °F. Setting range: °C/ °F Default setting: °C 2. Menu⇒ II ⇒Temperature unit flashes ⇒ Λ ⇒°C/ °F ⇒ V ⇒°C/ °F optris LS – E2006-01-A…

  • Page 17: Buzzer

    (preferably in combination with the CF mode), the ability to switch allows a comfortable operation in both positions. Setting range: Auto/ Off/ On Default setting: Auto 2. Menu⇒ II ⇒2x I ⇒current setting ⇒ Λ ⇒A ⇒ V ⇒A optris LS – E2006-01-A…

  • Page 18: Ambient Temperature Compensation

    An activation of this function on the LS for the first time is only possible with the supplied software [► Device Setup]. 2. Menu⇒ II ⇒3x I ⇒Tamb ⇒ Λ ⇒ INCREASE ALUE ⇒ V ⇒ DECREASE ALUE ⇒ II ⇒ ACTIVATE DEACTIVATE optris LS – E2006-01-A…

  • Page 19: Reset

    I ⇒RES⇒ II ⇒RES flashes ⇒ II ⇒R ESET ⇒ I ⇒HOLD ⇒Trigger⇒Measure mode depends on the status of Tamb function The stored values in the data logger will not be deleted with the reset function. optris LS – E2006-01-A…

  • Page 20: Data Logger

    If the storage mode is started the next free position will automatically be shown. If you select an occupied position, the P flashes in the upper display. The storage function can also be executed after recall of the last value [► Recall (Last Value)]. optris LS – E2006-01-A…

  • Page 21: Material And Location Names

    Disc symbol + choosen position [Pxx] ⇒2x II ⇒1. character flashes ⇒ Λ ⇒ CHANGE ALUE ⇒ V ⇒ CHANGE ALUE ⇒ II ⇒next character flashes ⇒ Λ ⇒ CHANGE ALUE ⇒ V ⇒ CHANGE ALUE ⇒ I ⇒S after input of all characters: optris LS – E2006-01-A…

  • Page 22: Data Logger Recall

    P -1⇐ V ⇐P xx⇒ Λ ⇒P +1 TObj Material and location name ⇑ ⇓ ⇑ TObj Emissivity ⇑ ⇑ ⇓ Trigger+ Λ Λ ⇓ ⇓ MAX/ TObj TObj/ MAX/ MIN/ AVG/ DIF TExt [probe temperature] 3 + 4 optris LS – E2006-01-A…

  • Page 23: Thermocouple Probe

    If, in addition, the Tamb-function is activated, the lower display will toggle between Tamb value Emissivity, t/c probe temperature and [► Ambient Temperature Compensation] The t/c probe in combination with the LS can be used to determine an unknown emissivity value [► Emissivity]. optris LS – E2006-01-A…

  • Page 24: Software Optrisconnect

    Please connect the LS with your computer by using the special USB adapter cable. After you have started the software and the communication has been established the status line (below the time axis) will show the following information: optris LS – E2006-01-A…

  • Page 25
    If you cannot establish a communication in spite of correct connection between LS and computer please choose the correct COM port under Menu: Setup\ Interface. If the USB adapter cable is connected this port is marked [Infrared Thermometer Adapter]: Language You can select the desired language under Menu: Setup\ Language. optris LS – E2006-01-A…
  • Page 26: Data Logger Functions

    Logger temperatures, on which the set High-Alarm value has been exceeded, will be shown in the table red and bold. Logger temperatures, on which the set Low-Alarm value has been fallen below, will be shown in the table blue and bold. optris LS – E2006-01-A…

  • Page 27: Time Stamp

    Material- and Location Names You can assign descriptions to each logger position by choosing between 20 predefined descriptions or defining own descriptions. The table of the predefined descriptions can be edited with the software. optris LS – E2006-01-A…

  • Page 28: Digital Displays

    If the LS is connected to your computer and you start the software, the current temperature TObj will be shown as digital display (top right). You can add additional displays for the internal temperature TInt and the temperature of a connected t/c probe TExt [Menu: View\ Digital displays]. optris LS – E2006-01-A…

  • Page 29: Diagram Functions

    To start a measurement, please press the Start button in the tool bar [Menu: Measurement\ Start]. Control elements of the time axis: Scroll bar Zoom in (increase) Zoom out (decrease) Whole range H: Hold/ C: Continue optris LS – E2006-01-A…

  • Page 30
    This option enables an optimum display of the temperature graph. A manual scaling can be done at any time using the control elements of the temperature axis. Activation of the desired option: Control elements (temperature axis) or [Menu: Diagram]. optris LS – E2006-01-A…
  • Page 31
    If none of both options is activated, a new measurement will be started after termination of one measurement and pressing of the Start button. In this case the former data are deleted! optris LS – E2006-01-A…
  • Page 32
    [TObj, TInt, TExt] Pen Width Pen width of the temperature graphs [1…5] Color Color of the temperature graph and digital displays Initial time Time frame on the x-axis, which should be displayed at the beginning of a measurement optris LS – E2006-01-A…
  • Page 33
    Max data count and Recording interval A change of the parameter Max data count will have influence on the Memory and Recording time. A change of the parameter Recording interval will have influence on the Recording time only. optris LS – E2006-01-A…
  • Page 34: Device Setup

    To load the factory default settings into the unit please press the Factory Default button (same functionality as ► Reset). An additional query avoids a reset of the unit by mistake. immediately A change of parameters will be taken over from the connected unit and vice versa. optris LS – E2006-01-A…

  • Page 35: Device Information

    Device type Description from the manufacturer Firmware Rev. Revision number of the internal software Hardware Rev. Revision number of the internal hardware Serial No. Serial number of the unit IR Temperature range Measurement range (IR) optris LS – E2006-01-A…

  • Page 36: Specification

    (red/ blue) Bar graph display: auto scaling Laser: <1mW, class II, 630-650 nm SF: patented crosshair laser (size of crosshairs = spot size@ any distance) CF: two point laser (laser dot size = spot size@ focus distance) optris LS – E2006-01-A…

  • Page 37
    420 g Vibration: IEC 68-2-6: 3G, 11 – 200Hz, any axis Shock: IEC 68-2-27: 50G, 11ms, any axis Tripod mounting: ¼ — 20 UNC at 23°C ambient temperature and object temperature: 20…900°C below 20°C and above 30°C optris LS – E2006-01-A…
  • Page 38: Factory Default Setting

    LS – E2006-01-A…

  • Page 39: Maintenance

    20 minutes for thermal stabilization before the use to prevent the possibility of inaccurate temperature readings. In case of problems or questions, which may arise when you use the optris ® LS, please contact our service department.

  • Page 40: Principle Of Operation

    The specifications of the lens decisively determine the optical path of the infrared thermometer, which is characterized by the ratio Distance-to-Spot-size. The spectral filter selects the wavelength range, which is relevant for the temperature measurement. The detector in cooperation with the processing electronics transforms the emitted infrared radiation into electrical signals. optris LS – E2006-01-A…

  • Page 41: Emissivity

    Now set the emissivity to 0,95 and take the temperature of the sticker. Afterwards, determine the temperature of the adjacent area on the measuring object and adjust the emissivity according to the value of the temperature of the sticker. optris LS – E2006-01-A…

  • Page 42
    (Appendix A and B). These are average values, only. The actual emissivity of a material depends on the following factors: temperature measuring angle geometry of the surface thickness of the material constitution of the surface (polished, oxidized, rough, sandblast) spectral range of the measurement transmissivity (e.g. with thin films) optris LS – E2006-01-A…
  • Page 43: Appendix A — Emissivity Table Metals

    0,7-0,9 Iron non oxidized 0,05-0,2 non oxidized 0,05 rusted 0,5-0,7 Titanium polished 0,05-0,2 oxidized 0,5-0,9 oxidized 0,5-0,6 forged, blunt Wolfram polished 0,03-0,1 Iron, casted non oxidized Zinc polished 0,02 oxidized 0,6-0,95 oxidized Lead polished 0,05-0,1 optris LS – E2006-01-A…

  • Page 44: Appendix B — Emissivity Table Non Metals

    Glass 0,85 Grit 0,95 Gypsum 0,8-0,95 0,98 Limestone 0,98 Paint non alkaline 0,9-0,95 Paper any color 0,95 Plastic >50 µm non transparent 0,95 Rubber 0,95 Sand Snow Soil 0,9-0,98 Textiles 0,95 Water 0,93 Wood natural 0,9-0,95 optris LS – E2006-01-A…

(Ocr-Read Summary of Contents of some pages of the optris LaserSight Document (Main Content), UPD: 09 May 2023)

  • 18, optris LS – E2006-01-A 16 A UTO : automatic position detection (by internal position sensor) and display switch according to the handling of the unit O FF : no switch (for reading at horizontal measurements) O N : permanent switch (for reading at vertical measurements) If O N is activated the display will switch immediately (see the right picture). Please note, that in this context also the assignment of the Mode buttons (I und II) changes. Ambient Temp…

  • 24, optris LS – E2006-01-A 22 Software OptrisConnect Installation and Start Main functions:  Download of logger data  Display and record of temperature trends  Setup of parameters System requirements:  Windows XP, 2000  USB interface  Hard disc with at least 30 MByte free space  At least 128 MByte RAM  CD-ROM drive Insert the installation CD into the according drive on your compu…

  • 35, optris LS – E2006-01-A 33 Device Information The button Info [Menu: Device\ Device Info] will display the following unit-specific information: Device type Description from the manufacturer Firmware Rev. Revision number of the internal software Hardware Rev. Revision number of the internal hardware Serial No. Serial number of the unit IR Temperature range Measurement range (IR)

  • 31, optris LS – E2006-01-A 29 S TOP M EASUREMENT To stop the current measurement please press the Stop button [Menu: Measurement\ Stop]. The Save button [Menu: File\ Save as] opens an explorer window to select destination and file name [file type: *.dat]. S AVING OF D ATA The menu item options [Menu: Setup\ Options] enables the following settings for data protection: Warning if unsaved data exist if activated, each …

  • 30, optris LS – E2006-01-A 28 Any activation of a control element of the time axis will stop the further actualization of the measurement graph. The measurement itself continues in the background. To return to the current measurement graph please press the Pause button [Menu: Measurement\ Pause] or C. During the stopped status any parts of the diagram can be selected with the Time scroll bar. With the zoom in- button + these parts can be st…

  • 15, Long-Term Measurement (Lock Mode) This function allows a continuous measurement without pulling the trigger for that time. The laser is only working if the trigger is pulled. Setting range: On/ Off Default setting: Off HOLD⇒ II ⇒3x I ⇒Lock symbol flashes ⇒ Λ ⇒O N / O FF ⇒ V ⇒O N / O FF after setting to On: 2x I ⇒HOLD+Lock⇒Trigger⇒starting Measurement mode+Lock or: Trigger⇒starting Measurement mode+Lock …

  • 9, optris LaserSight optris LS – E2006-01-A 7 Measurement Functions The measured temperature will be shown in the main display [1]. In the upper display the according maximum temperature [2] and in the lower display the set emissivity [3] will be displayed. The bar graph in the right part of the display [4] shows temperature trends. The scaling will be done automatically between minimum reading (no segment) and maximum reading…

  • 19, optris LS – E2006-01-A 17 If the Tamb-function is activated, the current set Tamb-value can be easily displayed as follows: Trigger+ Λ ⇒Toggle between Emissivity and Tamb in lower display If, in addition, a thermocouple probe is connected, the lower display will toggle between Emissivity, t/c probe temperature and Tamb value. [► Thermocouple Probe] Reset With this function the unit can be set back to the factory default values [► Fact…

  • 1, optris LaserSight optris ® LaserSight ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ Operators manual

  • 26, optris LS – E2006-01-A 24 Data Logger Functions To download the logger data from the unit please press the Logger -button [Menu: Measurement\ Download logger data]. All data from the logger will be displayed in an extra window as a table: Columns in the logger table Index serial number Date date of measurement Time time of measurement TObj object temperature TObj Min min. …

  • 6, Basic Operation Batteries Please do not use old and new batteries together. Please use only alkaline or rechargeable batteries [Type: Mignon AA, R6, UM3]. To open the battery compartment gently press the cover lid on the left side of the handle in direction of the arrow (see picture). Insert the batteries (orientation as shown inside the compartment) and close the cover lid. Your new LaserSight is already equipped with batt…

  • 22, optris LS – E2006-01-A 20 Data Logger Recall To recall a stored measurement protocol the unit must be set into the Measure mode: Trigger+ V [while keeping the trigger pressed]⇒Disc symbol flashes⇒P xx [starting with position 00] To switch between the data logger positions and different displays please proceed as follows: Upper display Main display Lower display Examples P -1�…

  • 3, optris LaserSight optris LS – E2006-01-A 1 CE-Conformity The product complies with the following standards: EMC: EN 61326-1 Safety Regulations: EN 61010-1:1993/ A2:1995 The product accomplishes the requirements of the EMC Directive 89/336/EEC and of the low-voltage directive 73/23/EEC. Optris GmbH Str. 49, Nr. 14 D – 13127 Berlin GERMANY Tel.: +49-30-500 197-0 Fax: +49-30-500 197-10 E-mail: [email protected] Internet: www.optris.com Scope of Su…

  • 25, COMxx: Opened active COM port if a USB adapter cable is connected LS: Connected successful communication with the connected LS SF/ CF selected optics mode on the LS Please use for a connection between the LS and a computer only the supplied USB adapter cable, as otherwise there will be no function. The connection cable supplied is not a standard USB cable! As long as the LS is connected to your computer it will be powered via the USB interfa…

  • 28, optris LS – E2006-01-A 26 To open the table please press the Names button [Menu: Device\ Material and location names]. Then mark the entry which you would like to edit with the cursor and enter the desired name. The maximum length is four digits. The following character set can be used: [A…Z] [0…9] [-/<>] [Space]. If a wrong input is made (no character/ more than 4 characters / invalid character) the position number in the table appears red and the tabl…

  • 44, optris LS – E2006-01-A 42 Appendix B – Emissivity Table Non Metals typical Emissivity Asbestos 0,95 Asphalt 0,95 Basalt 0,7 Carbon non oxidized 0,8-0,9 graphite 0,7-0,8 Carborundum 0,9 Ceramic 0,95 Concrete 0,95 Glass 0,85 Grit 0,95 Gypsum 0,8-0,95 Ice 0,98 Limestone 0,98 Paint non alkaline 0,9-0,95 Paper any color 0,95 Plastic >50 µm non transparent 0,95 Rubber 0,95 Sand 0,9 Snow 0,9 Soil 0,9-0,98 Text…

  • 27, optris LaserSight optris LS – E2006-01-A 25 Save as… opens an explorer window to save the logger data on your computer [*.lgg] Open File… opens an explorer window to open existing logger files 1) Clear Logger… After confirmation of the security query all logger data inside the LS will be deleted [unit display shows: CLR]. The status line inside the data logger window (beneath the table) shows the location and file name of the current data. 1) The logger file …

  • 11, optris LS – E2006-01-A 9 WARNING: Do not point the laser directly at the eyes of persons or animals! Do not stare into the laser beam. Avoid indirect exposure via reflective surfaces! Optics The LS has switchable optics. The two possible operating modes are indicated as SF mode (Standard Focus) and CF mode (Close Focus). In the SF mode (standard operating mode) objects ≥ 16mm can be measured. The measurement spot will be exactly marked with the p…

CE-Conformity

The product complies with the following standards:

EMC:

Safety Regulations:

The product accomplishes the requirements of the EMC Directive 89/336/EEC

and of the low-voltage directive 73/23/EEC.

Scope of Supply

LS unit

2 batteries (type AA)

t/c insertion probe

USB interface cable

software

pouch

hard case

operators manual

You will find the serial number on the unit. Always use this number when you contact the customer service

concerning maintenance, additional order of components, spare parts or repairs.

EN 61326-1

EN 61010-1:1993/ A2:1995

optris LS – E2006-01-A

Optris GmbH

Str. 49, Nr. 14

D – 13127 Berlin

GERMANY

Tel.: +49-30-500 197-0

Fax: +49-30-500 197-10

E-mail: info@optris.de

Internet: www.optris.com

1

Metal Applications

Non-contact temperature measurement for industry and R&D

Optris has been developing and manufacturing innovative infrared measurement devices for non-contact temperature measurement, including infrared cameras, and stationary industrial IR thermometers for area and point  measurement, for more than 20 years.

Our comprehensive product portfolio comprises infrared measurement devices for different industrial applications as well as research & development. Along with our free thermal analysis software, our measurement devices enable constant monitoring and control of virtually every manufacturing process, and reductions in production costs through specific process optimization.

More Industries

The process and product temperature is an important physical indicator for manufacturing processes and ensures a high quality level of the production line. 

All Optris products apply in different areas, covering the non-contact temperature measurement. This covers the plastic industry, the food industry as well as the solar industry and life science. 

Infrared thermometers / pyrometers for

Universal Applications

Metal Applications

Glass Applications

Plastics Applications

Flames Applications

Fast Applications

Hot Applications

Optris infrared thermometers and pyrometers for spot measurements are particularly well suited for precise temperature monitoring of industrial manufacturing processes, research and development, and function checks of a diverse range of devices and systems.

Infrared Cameras / Thermal imagers for

Glass applications

Metal applications

Universal applications

Electronics applications

Optris’ infrared cameras are fully radiometric stationary thermographic systems with an excellent price-performance ratio. The thermal imaging cameras are connected to a PC via USB and they are immediately ready to be used. Temperature data is displayed through the license-free analysis software optris PIX Connect.

Upcoming Events

  • Home
  • Brands
  • optris Manuals
  • Thermometer
  • optris LaserSight

1 docs – User Manuals, Help Guides and Specs – for the optris LaserSight product are present in our data base.

  • optris LaserSight Operator's Manual (44 pages)

    optris LaserSight Operator’s Manual (44 pages)

    optris Thermometer LaserSight : User Guide

    Pages: 44 | Size:

Related Products:

  • optris LT

  • optris CX

  • optris CTlaser LT

  • optris CT video series

  • optris CTratio 1M Series

  • optris CSlaser LT

  • optris CTratio

  • optris P20 Series

  • optris MS

  • optris P20 LT

Product Types:

  • optris Recording Equipment

  • optris Other

  • optris Server

  • optris Kitchen Appliances

  • optris Cables and connectors

  • optris Desktop

  • optris Security Camera

  • optris Camera Accessories

  • optris Thermometer

  • optris Temperature Controller

  • optris IP Camera

  • optris Thermal cameras

  • optris Laboratory Equipment

  • optris Thermographic Cameras

  • optris USB Interfaces

  • optris Industrial Equipment

Tips for Finding Manuals:

This web-page provides a list of 1 accessible operating manuals and information books describing optris LaserSight.
All manuals and instructions for optris LaserSight are introduced in an easy-to-use PDF format and may be gratuitously downloaded or looked through directly from the site.

The page offers the following types of manuals: Thermometer.

Helpful hints: While selecting a necessary guide for optris LaserSight one should pay special attention to the type of the document.
We try to supply you with the fullest possible set of papers we or our users are able to find. These may be overviews and specifications of the device, mounting and installing instructions, the unit operating rules and maintenance regulations and much more.

Haven’t found a required manual for your optris LaserSight?

Check in a while. We update our guides collection and add new documents on a daily basis for you to be always able to find the very paper you need on our web-site. In case you own a directory or an instruction for optris LaserSight, which is absent on our site, and you’d like to share it with the public, please send it to us as a scanned copy or a PDF file, and we’ll definitely place it on our page while providing your name as a supplier of the doc. Lots of our users will be grateful for your assistance!

Понравилась статья? Поделить с друзьями:
  • Должностная инструкция лица ответственного за промышленную безопасность
  • Дифлюкан свечи от молочницы инструкция по применению
  • Пао авиакомпания ютэйр руководство
  • Втор ком руководство
  • Оттеночный бальзам concept медный инструкция по применению