Moxa nport 5250 инструкция на русском

Moxa Technologies NPort IA 5250 series User Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

NPort IA5150/5250 Series

User’s Manual

Second Edition, May 2006

www.moxa.com/product

Moxa Technologies Co., Ltd.

Tel:

+886-2-8919-1230

Fax:

+886-2-8919-1231

Web: www.moxa.com

MOXA Technical Support

Worldwide:

The Americas

support@moxa.com.tw

support@moxa.com

loading

Related Manuals for Moxa Technologies NPort IA 5250 series

Summary of Contents for Moxa Technologies NPort IA 5250 series

  • Page 1
    NPort IA5150/5250 Series User’s Manual Second Edition, May 2006 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.com.tw The Americas support@moxa.com…
  • Page 2: Copyright Notice

    Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.

  • Page 3: Table Of Contents

    Table of Contents Chapter 1 Introduction ………………..1-1 Overview ……………………..1-2 Package Checklist……………………. 1-2 Product Features ……………………1-2 Product Specifications ………………….1-3 Chapter 2 Getting Started ………………2-1 Panel Layout……………………. 2-2 Connecting the Hardware ………………… 2-2 Wiring Requirements………………..2-3 Connecting the Power………………..2-3 Grounding NPort IA5150/5250 Series ……………..

  • Page 4
    Accessible IP Settings………………….5-31 Auto Warning Settings………………….5-32 Auto warning: E-mail and SNMP trap …………… 5-32 Event Type……………………5-33 Monitor……………………..5-36 Monitor Line………………….. 5-36 Monitor Async………………….5-36 Monitor Async-Settings………………..5-36 Monitor Relay Output………………..5-36 Change Password…………………… 5-37 Load Factory Default………………….5-37 Chapter 6 Configuring NPort Administrator………….6-1 Overview ……………………..
  • Page 5: Chapter 1 Introduction

    Introduction Chapter 1 Welcome to the NPort IA Series of industrial serial device servers. In this manual, we refer to the seven products in the series collectively as “NPort IA5150/5250 Series.” The seven models in the NPort IA5150/5250 Series are: 1.

  • Page 6: Overview

    NPort IA5150/5250 Series User’s Manual Introduction Overview The NPort IA5150/5250 series of device servers deliver easy and reliable serial-to-Ethernet connectivity for the industrial automation market. The NPort IA5150/5250 series is designed to allow any serial device to connect to an Ethernet network. The compact size of NPort IA device servers makes them an ideal choice for connecting RS-232/422/485 serial devices, such as PLCs, sensors, meters, motors, drives, barcode readers, and operator displays.

  • Page 7: Product Specifications

    NPort IA5150/5250 Series User’s Manual Introduction Product Specifications NPort IA5150-M-SC/5150I-M-SC/5150-S-SC/5150I-S-SC LAN Fiber Port 1 100BaseFX port (SC connector) NPort IA5150/5150I/5250 LAN Ethernet Switch Ports 2 10/100BaseT(X) ports (RJ45 connector) Protection Built-in 1.5 KV magnetic isolation Optical Fiber Distance Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km) Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km) Min.

  • Page 8
    NPort IA5150/5250 Series User’s Manual Introduction Serial Communication Parameters Parity None, Even, Odd, Space, Mark Data Bits 5, 6, 7, 8 Stop Bit 1, 1.5, 2 Flow Control RTS/CTS (for RS-232 port only), XON/XOFF Transmission Speed 110 bps to 230.4 Kbps Software Features Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS,…
  • Page 9: Chapter 2 Getting Started

    Getting Started Chapter 2 In this chapter, we give instructions on installing NPort IA5150/5250 device servers. Software installation is covered in subsequent chapters. The following topics are covered in this chapter: Panel Layout Connecting the Hardware Wiring Requirements Connecting the Power Grounding NPort IA5150/5250 Series Connecting to the Network Connecting to a Serial Device…

  • Page 10: Panel Layout

    NPort IA5150/5250 Series User’s Manual Getting Started Panel Layout NPort IA5150 Series Top View Front View Bottom View PWR1 PWR2 Indicators Reset Reset Fiber optic RS-422/485 Ethernet RS-232 Dual power input 5150-M-SC and relay output NPort IA 5250 Top View Front View Bottom View PWR1…

  • Page 11: Wiring Requirements

    NPort IA5150/5250 Series User’s Manual Getting Started Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your NPort IA5150/5250 Series. Wiring Caution! Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.

  • Page 12: Connecting To The Network

    NPort IA5150/5250 Series User’s Manual Getting Started SG: The Shielded Ground (sometimes called Protected Ground) contact is the left most contact of the 7-pin power terminal block connector when viewed from the angle shown here. Connect the SG wire to an appropriate grounded metal surface.

  • Page 13: Led Indicators

    NPort IA5150/5250 Series User’s Manual Getting Started LED Indicators The top panels of all NPort IA5150/5250 device servers have four LED indicators, as described in the following table. LED Name LED Color LED Function PWR1, Power is being supplied to power input PWR1, PWR2. PWR2 Steady on: Power is on and NPort IA is booting up.

  • Page 14: Chapter 3 Initial Ip Address Configuration

    Initial IP Address Configuration Chapter 3 When setting up your NPort IA5150/5250 for the first time, the first thing you should do is configure the IP address. This chapter introduces the methods that can be used to configure the device server’s IP address. Select one of the initial IP Address configuration methods to configure NPort IA5150/5250’s IP Address.

  • Page 15: Initializing Nport Ia5150/5250’S Ip Address

    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration Initializing NPort IA5150/5250’s IP Address 1. Determine whether your NPort IA5150/5250 needs to use a Static IP or Dynamic IP (either DHCP or BOOTP application). 2. If NPort IA5150/5250 is used in a Static IP environment, you can use NPort IA5150/5250 Administration Suite, ARP, Web Console, Telnet Console, or Serial Console to configure the new IP address.

  • Page 16: Telnet Console

    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration Take the following steps to use ARP to configure the IP address: 1. Obtain a valid IP address for your NPort IA5150/5250 from your network administrator. 2. Obtain NPort IA5150/5250’s MAC address from the label on its bottom panel. 3.

  • Page 17
    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration 4. Type 2 to select Network settings, and then press Enter. 5. Type 1 to select IP address and then press Enter. 6. Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter.
  • Page 18
    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration 7. Press any key to continue. 8. Type m and then press Enter to return to the main menu. 9. Type s and then press Enter to Save/Restart the system. 10. Type y and then press Enter to save the new IP address and restart NPort IA5150/5250.
  • Page 19: Serial Console (19200, N, 8, 1)

    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration Serial Console (19200, n, 8, 1) You may use the RS-232 console port to set up the IP address for NPort IA5150/5250. We suggest using PComm Terminal Emulator, which is available free of charge as part of the PComm Lite program suite, to carry out the installation procedure, although other similar utilities may also be used.

  • Page 20
    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration 6. Press the “ ` ” key continuously and then power on the NPort IA5150/5250. 7. NPort IA5150/5250 will automatically switch from data mode to console mode as it receives a continuous string of “…
  • Page 21: Choosing The Proper Operation Mode

    Choosing the Proper Operation Mode Chapter 4 In this chapter, we describe the various NPort IA5150/5250 operation modes. The options include an operation mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP socket programming concepts. After choosing the proper operation mode in this chapter, refer to Chapter 5 for detailed configuration parameter definitions.

  • Page 22: Overview

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode Overview NPort IA5150/5250 Serial Device Servers network-enable traditional RS-232/422/485 devices, in which a Serial Device Server is a tiny computer equipped with a CPU, real-time OS, and TCP/IP protocols that can bi-directionally translate data between the serial and Ethernet formats. Your computer can access, manage, and configure remote facilities and equipment over the Internet from anywhere in the world.

  • Page 23: Tcp Server Mode

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode ATTENTION The driver used for Real COM Mode comes with the NPort IA5150/5250 NPort Administrator. The driver is installed automatically on your computer when you install NPort IA5150/5250 Administration Suite. One of the major conveniences of using Real COM Mode is that Real COM Mode allows users to continue using RS-232/422/485 serial communications software that was written for pure serial communications applications.

  • Page 24: Tcp Client Mode

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode TCP Client Mode In TCP Client mode, NPort IA5150/5250 can TCP Client Mode actively establish a TCP connection to a pre-defined host computer when serial data arrives. After the data has been transferred, NPort IA5150/5250 can automatically disconnect from the host computer by using the TCP alive check TCP/IP…

  • Page 25: Ethernet Modem Mode

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode Ethernet Modem Mode Ethernet Modem Mode is designed for use with legacy operating systems, such as MS-DOS, that do not support TCP/IP Ethernet. By connecting one of NPort IA5150/5250’s serial port to the MS-DOS computer’s serial port, it is possible to use legacy software originally designed to transmit data via modem, but now transmit the data over the Ethernet.

  • Page 26: Web Console Configuration

    Web Console Configuration Chapter 5 The Web Console is the most user-friendly method available to configure NPort IA5150/5250. In this chapter, we introduce the Web Console function groups and function definitions. The following topics are covered in this chapter: Opening Your Browser Basic Settings Network Settings Serial Settings…

  • Page 27: Opening Your Browser

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Opening Your Browser 1. Open your browser with the cookie function enabled. (To enable your browser for cookies, right click on your desktop Internet Explorer icon, select Properties, click on the Security tab, and then select the three Enable options as shown in the figure below.) 2.

  • Page 28
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION If you use other web browsers, remember to Enable the functions to “allow cookies that are stored on your computer” or “allow per-session cookies.” NPort IA5150/5250 uses cookies only for “password” transmission. ATTENTION Refer to Chapter 3, “Initial IP Address Configuration,”…
  • Page 29: Basic Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION If you can’t remember the password, the ONLY way to start configuring NPort IA5150/5250 is to load factory defaults by using the Reset button. Remember to use NPort Administrator to export the configuration file when you have finished the configuration.

  • Page 30
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION First time users should select the time zone first. The Console will display the “real time” according to the time zone compared to GMT. If you would like to modify the real time clock, select “Local time.” NPort IA5150/5250’s firmware will modify the GMT time according to the Time Zone.
  • Page 31: Network Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Web console Setting Factory Default Necessity Enable or Disable Enable Required Telnet console Setting Factory Default Necessity Enable or Disable Enable Required ATTENTION If you disable both the “Web console” and “Telnet console,” you can still use NPort Administrator to configure NPort IA5150/5250 either locally or remotely over the network.

  • Page 32
    NPort IA5150/5250 Series User’s Manual Web Console Configuration You must assign a valid IP address to NPort IA5150/5250 before it will work in your network environment. Your network system administrator should provide you with an IP address and related settings for your network. The IP address must be unique within the network (otherwise, NPort IA5150/5250 will not have a valid connection to the network).
  • Page 33: Snmp Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration IP configuration Setting Factory Default Necessity Static Static Required DHCP DHCP/BOOTP BOOTP ATTENTION In Dynamic IP environments, the firmware will retry 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server. The Timeout for each try increases from 1 second, to 3 seconds, to 5 seconds.

  • Page 34: Ip Address Report

    NPort IA5150/5250 Series User’s Manual Web Console Configuration The SNMP contact information usually includes an emergency contact name and telephone or pager number. Location Setting Factory Default Necessity 1 to 39 characters None Optional (E.g., Floor 1, office 2) Specify the location string for SNMP agents such as NPort IA5150/5250. This string is usually set to the street address where the NPort IA5150/5250 is physically located.

  • Page 35: Serial Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Serial Settings Click on Serial Settings, located under Main Menu, to display serial port settings for ports 1 and 2. To modify serial settings for a particular port, click on either Port 1 or Port 2 under Serial Settings, located under Main Menu on the left side of the browser window.

  • Page 36: Operating Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Baud rate Setting Factory Default Necessity 110 bps to 230400 bps 115200 bps Required Data bits Setting Factory Default Necessity 5, 6, 7, 8 Required When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits. Stop bits Setting Factory Default…

  • Page 37: Real Com Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Real COM Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort IA5150/5250 automatically closes the TCP connection if there is no TCP activity for the given time.

  • Page 38
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION When Max connection is set to 2, 3, or 4, this means that NPort IA5150/5250 will be using a “multi connection application” (i.e., 2, 3, or 4 hosts are allowed access to the port at the same time).
  • Page 39
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1 KB, the NPort IA5150/5250 will automatically pack the data and send it to the Ethernet.
  • Page 40: Tcp Server Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration TCP Server Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort IA5150/5250 automatically closes the TCP connection if there is no TCP activity for the given time.

  • Page 41
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION The Inactivity time should at least be set larger than that of Force transmit timeout. To prevent the unintended loss of data due to the session being disconnected, it is highly recommended that this value is set large enough so that the intended data transfer is completed.
  • Page 42
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Delimiter 2 Setting Factory Default Necessity 00 to FF (hex) None Optional Once the NPort IA5150/5250 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort IA5150/5250’s Ethernet port. ATTENTION Delimiter 2 is optional.
  • Page 43: Tcp Client Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration NPort IA5150/5250 should send that series of characters during a time interval less than the Force transmit timeout for NPort IA5150/5250, and the total length of data must be less than or equal to NPort IA5150/5250’s internal buffer size.

  • Page 44
    NPort IA5150/5250 Series User’s Manual Web Console Configuration TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort IA5150/5250 closes the TCP connection automatically if there is no TCP activity for the given time.
  • Page 45
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Packing length Setting Factory Default Necessity 0 to 1024 Optional Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes.
  • Page 46
    NPort IA5150/5250 Series User’s Manual Web Console Configuration only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout. The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate.
  • Page 47
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Connection control Setting Factory Default Necessity Startup/None, Startup/None Required Any Character/None, Any Character/Inactivity Time, DSR ON/DSR OFF, DSR ON/None, DCD ON/DCD OFF, DCD ON/None The meaning of each of the above settings is given in the table below. In general, both the Connect condition and Disconnect condition are given.
  • Page 48: Udp Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration UDP Mode Packing length Setting Factory Default Necessity 0 to 1024 Optional Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes.

  • Page 49
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Delimiter process Setting Factory Default Necessity Do nothing Delimiter + 1 Do Nothing Optional Delimiter + 2 Strip Delimiter [Delimiter + 1] or [Delimiter + 2]: The data will be transmitted when an additional byte (for Delimiter +1), or an additional 2 bytes (for Delimiter +2) of data is received after receiving the Delimiter.
  • Page 50: Pair Connection Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Destination IP address 2/3/4 Setting Factory Default Necessity IP address range Begin: Empty Optional E.g., Begin: 192.168.1.11 End: Empty End: 192.168.1.20 Port: 4001 Local listen port Setting Factory Default Necessity 1 to 65535 4001 Required The UDP port that NPort IA5150/5250 listens to, and that other devices must use to contact NPort…

  • Page 51: Pair Connection Slave Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Destination IP address Setting Factory Default Necessity IP address or Domain Name blank Optional (E.g., 192.168.1.1) TCP port No. 4001 Required The Pair Connection “Master” will contact the network host that has this IP address. Data will be transmitted through the port No.

  • Page 52: Ethernet Modem Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Ethernet Modem Mode Dial-in NPort IA5150/5250 listens for a TCP/IP connection request from the remote Ethernet modem or host. NPort IA5150/5250’s response depends on the ATS0 value, as outlined below. ATS0=0 (default): NPort IA5150/5250 will temporarily accept the TCP connection and then send the “RING”…

  • Page 53
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Ethernet Modem Setting Value Notes Necessity The TCP port that other devices must use to contact this device. To avoid conflicts with TCP port valid port No. Required standard TCP ports, the default is set to 4001. TCP connection is not closed due to an idle serial line.
  • Page 54
    NPort IA5150/5250 Series User’s Manual Web Console Configuration 16 AT&D Serial port DTR control AT&D0=recognize DTE always ready AT&D1, AT&D2=reply DTE when DTR On (default) 17 AT&F Restore manufacturer’s settings 18 AT&G Select guard time reply “OK” only 19 AT&R Serial port RTS option command reply “OK”…
  • Page 55: Reverse Telnet Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The TCP port that other devices must use to contact this device. To avoid conflicts with standard TCP ports, the default is set to 4001. Reverse Telnet Mode TCP alive check time Setting…

  • Page 56: Disabled Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Disabled Mode When Operation mode is set to Disabled, that particular port will be disabled. Check the “Apply the above settings to all serial ports” to apply this setting to the other port. Accessible IP Settings NPort IA5150/5250 uses an IP address based filtering method to control access to itself.

  • Page 57: Auto Warning Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Allowable Hosts Input format Any host Disable 192.168.1.120 192.168.1.120 / 255.255.255.255 192.168.1.1 to 192.168.1.254 192.168.1.0 / 255.255.255.0 192.168.0.1 to 192.168.255.254 192.168.0.0 / 255.255.0.0 192.168.1.1 to 192.168.1.126 192.168.1.0 / 255.255.255.128 192.168.1.129 to 192.168.1.254 192.168.1.128 / 255.255.255.128 Auto Warning Settings Auto warning: E-mail and SNMP trap…

  • Page 58: Event Type

    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION Consult your Network Administrator or ISP for the proper mail server settings. The Auto warning function may not work properly if it is not configured correctly. NPort IA5150/5250 SMTP AUTH supports LOGIN, PLAIN, CRAM-MD5 (RFC 2554). SNMP Trap Server SNMP trap server IP or domain name Setting…

  • Page 59
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Password changed The user has changed NPort IA5150/5250’s password. When the password changes, NPort IA5150/5250 will send an e-mail with the password changed notice before NPort IA5150/5250 reboots. If the NPort IA5150/5250 is unable to send an e-mail message to the mail server within 15 seconds, NPort IA5150/5250 will reboot anyway, and abort the e-mail auto warning.
  • Page 60
    NPort IA5150/5250 Series User’s Manual Web Console Configuration DCD changed A change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, If the DCD signal changes to low, it means that the connection line is down. When the DCD signal changes to low, NPort IA will immediately send a warning.
  • Page 61: Monitor

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Monitor Monitor Line Click on Line under Monitor to show the operation mode and status of each connection (IPx), for each of the two serial ports. Monitor Async Click on Async under Monitor to show the current status of each of the two serial ports. Monitor Async-Settings Click on Async Setting under Monitor to show the run-time settings for each of the two serial ports.

  • Page 62: Change Password

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Change Password Input the “Old password” and “New password” to change the password. Leave the password boxes blank to erase the password. If the password is erased, then NPort IA5150/5250 will not have password protection.

  • Page 63: Configuring Nport Administrator

    Configuring NPort Administrator Chapter 6 The following topics are covered in this chapter: Overview Installing NPort Administrator Configuration Broadcast Search Unlock Password Protection Configuring NPort IA5150/5250 Upgrading the Firmware Export Configuration Import Configuration Monitor Port Monitor COM Mapping On-line COM Mapping Off-line COM Mapping IP Location…

  • Page 64: Overview

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Overview Device Server Administrator lets you install and configure your NPort IA5150/5250 Series products easily over the network. Five function groups are provided to ease the installation process, allow off-line COM mapping, and provide monitoring and IP location server functions. Device Server Administrator is an integrated software suite that bundles Device Server Administrator and the IP Serial Library, and provides everything you need to manage, monitor, and modify your NPort IA5150/5250 from a remote location.

  • Page 65
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. Click on Next to install the program using the default program name, or select a different name. 4. Click on Install to proceed with the installation.
  • Page 66
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 5. The Installing window reports the progress of the installation. 6. Click on Next to proceed with the installation.
  • Page 67: Configuration

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 7. Click on Finish to complete the installation of NPort IA5150/5250 Administration Suite. Configuration The Administrator-Configuration window is divided into four parts. The top section contains the function list and online help area. (Windows NT does not support this .chm file format.) The five Administrator function groups are listed in the left section.

  • Page 68: Broadcast Search

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Broadcast Search The Broadcast Search function is used to locate all NPort IA5150/5250s that are connected to the same LAN as your computer. Since the Broadcast Search function searches by MAC address and not IP address, all NPort IA5150/5250s connected to the LAN will be located, regardless of whether or not they are part of the same subnet as the host.

  • Page 69: Unlock Password Protection

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator ATTENTION Before modifying NPort IA5150/5250’s configuration, use Broadcast Search to locate all NPort IA5150/5250s connected to the LAN, or use Specify by IP Address to locate a particular NPort IA5150/5250. Unlock Password Protection If the NPort IA5150/5250 is password protected (indicated by “Lock”…

  • Page 70: Configuring Nport Ia5150/5250

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. The “Lock” status will change to “Unlock,” and the Administrator utility will keep this NPort IA5150/5250 in the Unlock status throughout this Administrator session. The meanings of the six “Status” states are given below (note that the term Fixed is borrowed from the standard fixed IP address networking terminology): Lock The NPort IA5150/5250 is password protected, “Broadcast Search”…

  • Page 71
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 2. Unlock the NPort IA5150/5250 you wish to configure if it is password protected. Right click on the NPort IA5150/5250 and select Configure to start the configuration. 3. The progress bar shows that Administrator is retrieving configuration information from the specific NPort IA5150/5250.
  • Page 72: Upgrading The Firmware

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 5. You will now be able to modify Time Zone, Local Date, Local Time, and Time Server. ATTENTION You can simultaneously modify the configurations of multiple NPort IA5150/5250s that are of the same model. To select multiple NPort IA5150/5250s, hold down the Ctrl key when selecting additional NPort IA5150/5250s, or hold down the Shift key to select a group of NPort IA5150/5250s.

  • Page 73
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 2. Unlock the NPort IA5150/5250 you wish to configure if it is password protected. Right click on a specific NPort IA5150/5250 and select the Upgrade Firmware function to start upgrading the firmware. 3.
  • Page 74: Export Configuration

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Export Configuration To export the configuration of an NPort IA5150/5250, right click on the NPort IA5150/5250 and select Export Configuration and then follow the onscreen instructions. The Export Configuration function is a handy tool that can be used to produce a text file containing the current configuration of a particular NPort IA5150/5250.

  • Page 75: Monitor

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator ATTENTION You can simultaneously import the same configuration file into multiple NPort IA5150/5250s that are of the same model. To select multiple NPort IA5150/5250s, hold down the Ctrl key when selecting an additional NPort IA5150/5250, or hold down the Shift key to select a block of NPort IA5150/5250s.

  • Page 76
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Monitor Add Target Rescan 1. Click on Monitor under Function. 2. Click on Monitor Add Target from the menu bar, or click the right mouse button and select Add Target. 3. Click on Rescan. 6-14…
  • Page 77
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 4. Select your targets from the list, and then click on OK. Once the Monitor function is running: 1. The NPort IA5150/5250 list will appear on the Monitor screen. 2. Right click the panel and select Settings. 6-15…
  • Page 78
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. Select or de-select Monitor Items. Use the single arrowhead buttons to move highlighted items from one box to the other. Use the double arrowhead buttons to move all items in one box to the other.
  • Page 79
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 5. On the Advanced Settings page, select Display warning message for new event and/or Play warning music for new event. In the second case, you must enter the path to the WAV file that you want to be played.
  • Page 80
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 8. When one of the NPort IA5150/5250s loses connection with the Monitor program, a warning alert will display automatically. The warning music will be played at the same time. 9. In the Monitor screen, you can see that the NPort IA5150/5250s that are “Not Alive” are shown in red color.
  • Page 81: Port Monitor

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 11. The NPort IA5150/5250s that were reconnected, and are now “Alive,” will be shown in black color. Port Monitor The process described here is the same as in the previous “Monitor” section. The only difference is that you can select more items under Port Monitor than under Monitor.

  • Page 82: Com Mapping

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator COM Mapping Windows Administration Suite comes with Windows 95/98/ME/NT/2000/XP Real COM drivers. After you install NPort IA5150/5250 Administration Suite, there are two ways to set up the NPort IA5150/5250 serial port as your host’s remote COM port. The first way is with On-line COM Mapping.

  • Page 83
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. Add the target to which you would like to map COM ports. 4. The NPort IA5150/5250 list that appears is the list generated by the previous Broadcast Search. Select the NPort IA5150/5250 to which you would like to map COM ports. 5.
  • Page 84
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 6. Select the COM No. COM ports that are “In use” or “Assigned” will also be indicated in this drop-down list. If you select multiple serial ports or multiple NPort IA5150/5250s, remember to check the “Auto Enumerating”…
  • Page 85
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator function, the NPort driver will keep querying NPort’s firmware several times to make sure there is really no data queued in the NPort firmware buffer, rather than just flushing the local buffer. This kind of design is used because of some special considerations. However, it might take more time (on the order of several hundred milliseconds) than a native COM1, because it needs to work via Ethernet.
  • Page 86
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 9. After setting the COM Mapping, remember to select Apply Change to save the information in the host system registry. The host computer will not have the ability to use the COM port until after Apply Change is selected.
  • Page 87: Off-Line Com Mapping

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 11. To save the configuration to a text file, select Export COM Mapping. You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host.

  • Page 88
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 2. Modify the port settings as needed. 3. Right click in the NPort list section and select Apply Change. 6-26…
  • Page 89: Ip Location

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator IP Location When NPort IA5150/5250 is used in a dynamic IP environment, users must spend more time with IP management tasks. NPort IA5150/5250 Series products help out by periodically reporting their IP address to the IP location server, in case the dynamic IP has changed. 1.

  • Page 90
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 4. Click Go to start receiving the Auto IP address report from the NPort IA5150/5250 6-28…
  • Page 91: Ip Serial Lib

    IP Serial LIB Chapter 7 The following topics are covered in this chapter: Overview IP Serial LIB Function Groups Example Program…

  • Page 92: Overview

    NPort IA5150/5250 Series User’s Manual IP Serial LIB Overview What is IP Serial Library? IP Serial Library is a Windows library with frequently used serial command sets and subroutines. IP Serial Library is designed to reduce the complexity and poor efficiency of serial communication over TCP/IP.

  • Page 93: Ip Serial Lib Function Groups

    NPort IA5150/5250 Series User’s Manual IP Serial LIB IP Serial LIB Function Groups Server Control Port Control Input/Output Data Port Status Miscellaneous Inquiry nsio_init nsio_open nsio_read nsio_lstatus nsio_break nsio_end nsio_close nsio_SetReadTimeouts nsio_data_status nsio_break_on nsio_resetserver nsio_ioctl nsio_write nsio_break_off nsio_checkalive nsio_flowctrl nsio_SetWriteTimeouts nsio_breakcount nsio_DTR nsio_RTS…

  • Page 94: Appendix A Pinouts And Cable Wiring

    Pinouts and Cable Wiring Appendix A The following topics are covered in this appendix: Port Pinout Diagrams RS-232/422/485 (male DB9) Pinouts 4W/2W RS-485/RS-422 (Terminal Block) Pinouts Power Input and Relay Output Pinouts Cable Wiring Diagrams Serial Cables…

  • Page 95: Port Pinout Diagrams

    NPort IA5150/5250 Series User’s Manual Pinouts and Cable Wiring Port Pinout Diagrams RS-232/422/485 (male DB9) Pinouts 1 2 3 4 5 6 7 8 9 RS-422/ RS-232 RS-485 (2W) RS-485 (4W) TxD-(A) TxD+(B) RxD+(B) Data+(B) RxD-(A) Data-(A) 4W/2W RS-485/RS-422 (Terminal Block) Pinouts RS-422/ RS-485 (2W) RS-485 (4W)

  • Page 96: Cable Wiring Diagrams

    NPort IA5150/5250 Series User’s Manual Pinouts and Cable Wiring Cable Wiring Diagrams Serial Cables Female DB9 to Male DB9 Male DB9 Female DB9 Male DB9 Female DB9 RS-232 NPort IA Device Cable Wiring 9 pins 9 pins Female DB9 to Male DB25 Male DB9 Female DB9 Male DB25…

  • Page 97: Appendix B Well Known Port Numbers

    Well Known Port Numbers Appendix B In this appendix, which is included for your reference, we provide a list of Well Known port numbers that may cause network problems if you set NPort IA5150/5250 to one of these ports. Refer to RFC 1700 for Well Known port numbers, or refer to the following introduction from the IANA.

  • Page 98
    NPort IA5150/5250 Series User’s Manual Well Known Port Numbers TCP Socket Application Service Whois (nickname) (Login Host Protocol) (Login) Domain Name Server (domain) Finger protocol (Finger) World Wibe Web HTTP Netword news Transfer Protocol (NNTP) Network Time Protocol 160 – 223 Reserved for future use UDP Socket Application Service…
  • Page 99
    SNMP Agents with MIB II & RS-232 Appendix C like groups NPort IA5150/5250 has built-in SNMP (Simple Network Management Protocol) agent software that supports SNMP Trap, RFC1317 RS-232 like groups and RFC 1213 MIB-II. The following table lists the standard MIB-II groups, as well as the variable implementation for NPort IA5150/5250.
  • Page 100
    NPort IA5150/5250 Series User’s Manual SNMP Agents System MIB Interfaces MIB IP MIB ICMP MIB SysServices ifInUnknownProtos ipReasmFails IcmpOutTimeExcds ifOutOctets ipFragOKs IcmpOutParmProbs ifOutUcastPkts ipFragFails IcmpOutSrcQuenchs ifOutNUcastPkts ipFragCreates IcmpOutRedirects ifOutDiscards ipAdEntAddr IcmpOutEchos ifOutErrors ipAdEntIfIndex IcmpOutEchoReps ifOutQLen ipAdEntNetMask IcmpOutTimestamps ifSpecific ipAdEntBcastAddr IcmpOutTimestampReps ipAdEntReasmMaxSize IcmpOutAddrMasks IpNetToMediaIfIndex…
  • Page 101
    NPort IA5150/5250 Series User’s Manual SNMP Agents Address Translation MIB TCP MIB SNMP MIB AtNetAddress tcpRetransSegs snmpInTotalSetVars tcpConnState snmpInGetRequests tcpConnLocalAddress snmpInGetNexts tcpConnLocalPort snmpInSetRequests tcpConnRemAddress snmpInGetResponses tcpConnRemPort snmpInTraps tcpInErrs snmpOutTooBigs tcpOutRsts snmpOutNoSuchNames snmpOutBadValues snmpOutGenErrs snmpOutGetRequests snmpOutGetNexts snmpOutSetRequests snmpOutGetResponses snmpOutTraps snmpEnableAuthenTraps RFC1317: RS-232 MIB objects RS-232-like General Port RS-232-like Asynchronous Generic RS-232-like Group…
  • Page 102
    NPort IA5150/5250 Series User’s Manual SNMP Agents The Input Signal Table The Output Signal Table rs232InSigTable rs232OutSigTable rs232InSigEntry rs232OutSigEntry rs232InSigPortIndex rs232OutSigPortIndex rs232InSigName rs232OutSigName rs232InSigState rs232OutSigState…
  • Page 103
    Auto IP Report Protocol Appendix D NPort Series provides several ways to configure Ethernet IP addresses. One is DHCP Client. When you set up NPort to use DHCP Client to configure Ethernet IP addresses, it will automatically send a DHCP request over the Ethernet to find the DHCP Server. And then the DHCP Server will send an available IP address to the NPort.
  • Page 104: Appendix D Auto Ip Report Protocol

    NPort IA5150/5250 Series User’s Manual Auto IP Report Protocol Auto IP Report Format “MOXA”, 4 bytes Info[0] Info[1] … Info[n] Info [n] Field Length Data Variable, Length is “Length Field” Length ID List ID Value Description Length Note Server Name Variable ASCII char Hardware ID…

  • Page 105: Appendix E Service Information

    Service Information Appendix E This appendix shows you how to contact Moxa for information about this and other products, and how to report problems. In this appendix, we cover the following topics. MOXA Internet Services Problem Report Form Product Return Procedure…

  • Page 106: Moxa Internet Services

    NPort IA5150/5250 Series User’s Manual Service Information MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, driver updates, product information, and user’s manual updates.

  • Page 107: Problem Report Form

    NPort IA5150/5250 Series User’s Manual Service Information Problem Report Form MOXA NPort IA5150/5250 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product: NPort IA5150 NPort IA5150-M-SC NPort IA5150-S-SC NPort IA5150I NPort IA5150I-M-SC NPort IA5150I-S-SC NPort IA5250 2. Serial Number: _________________ Problem Description: Please describe the symptoms of the problem as clearly as possible, including any error messages you see.

  • Page 108: Product Return Procedure

    NPort IA5150/5250 Series User’s Manual Service Information Product Return Procedure For product repair, exchange, or refund, the customer must: Provide evidence of original purchase. Obtain a Product Return Agreement (PRA) from the sales representative or dealer. Fill out the Problem Report Form (PRF). Include as much detail as possible for a shorter product repair time.

  • Page 1
    NPort IA5150/5250 Series User’s Manual Second Edition, May 2006 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.com.tw The Americas support@moxa.com…
  • Page 2: Copyright Notice

    Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.

  • Page 3: Table Of Contents

    Table of Contents Chapter 1 Introduction ………………..1-1 Overview ……………………..1-2 Package Checklist……………………. 1-2 Product Features ……………………1-2 Product Specifications ………………….1-3 Chapter 2 Getting Started ………………2-1 Panel Layout……………………. 2-2 Connecting the Hardware ………………… 2-2 Wiring Requirements………………..2-3 Connecting the Power………………..2-3 Grounding NPort IA5150/5250 Series ……………..

  • Page 4
    Accessible IP Settings………………….5-31 Auto Warning Settings………………….5-32 Auto warning: E-mail and SNMP trap …………… 5-32 Event Type……………………5-33 Monitor……………………..5-36 Monitor Line………………….. 5-36 Monitor Async………………….5-36 Monitor Async-Settings………………..5-36 Monitor Relay Output………………..5-36 Change Password…………………… 5-37 Load Factory Default………………….5-37 Chapter 6 Configuring NPort Administrator………….6-1 Overview ……………………..
  • Page 5: Chapter 1 Introduction

    Introduction Chapter 1 Welcome to the NPort IA Series of industrial serial device servers. In this manual, we refer to the seven products in the series collectively as “NPort IA5150/5250 Series.” The seven models in the NPort IA5150/5250 Series are: 1.

  • Page 6: Overview

    NPort IA5150/5250 Series User’s Manual Introduction Overview The NPort IA5150/5250 series of device servers deliver easy and reliable serial-to-Ethernet connectivity for the industrial automation market. The NPort IA5150/5250 series is designed to allow any serial device to connect to an Ethernet network. The compact size of NPort IA device servers makes them an ideal choice for connecting RS-232/422/485 serial devices, such as PLCs, sensors, meters, motors, drives, barcode readers, and operator displays.

  • Page 7: Product Specifications

    NPort IA5150/5250 Series User’s Manual Introduction Product Specifications NPort IA5150-M-SC/5150I-M-SC/5150-S-SC/5150I-S-SC LAN Fiber Port 1 100BaseFX port (SC connector) NPort IA5150/5150I/5250 LAN Ethernet Switch Ports 2 10/100BaseT(X) ports (RJ45 connector) Protection Built-in 1.5 KV magnetic isolation Optical Fiber Distance Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km) Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km) Min.

  • Page 8
    NPort IA5150/5250 Series User’s Manual Introduction Serial Communication Parameters Parity None, Even, Odd, Space, Mark Data Bits 5, 6, 7, 8 Stop Bit 1, 1.5, 2 Flow Control RTS/CTS (for RS-232 port only), XON/XOFF Transmission Speed 110 bps to 230.4 Kbps Software Features Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS,…
  • Page 9: Chapter 2 Getting Started

    Getting Started Chapter 2 In this chapter, we give instructions on installing NPort IA5150/5250 device servers. Software installation is covered in subsequent chapters. The following topics are covered in this chapter: Panel Layout Connecting the Hardware Wiring Requirements Connecting the Power Grounding NPort IA5150/5250 Series Connecting to the Network Connecting to a Serial Device…

  • Page 10: Panel Layout

    NPort IA5150/5250 Series User’s Manual Getting Started Panel Layout NPort IA5150 Series Top View Front View Bottom View PWR1 PWR2 Indicators Reset Reset Fiber optic RS-422/485 Ethernet RS-232 Dual power input 5150-M-SC and relay output NPort IA 5250 Top View Front View Bottom View PWR1…

  • Page 11: Wiring Requirements

    NPort IA5150/5250 Series User’s Manual Getting Started Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your NPort IA5150/5250 Series. Wiring Caution! Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.

  • Page 12: Connecting To The Network

    NPort IA5150/5250 Series User’s Manual Getting Started SG: The Shielded Ground (sometimes called Protected Ground) contact is the left most contact of the 7-pin power terminal block connector when viewed from the angle shown here. Connect the SG wire to an appropriate grounded metal surface.

  • Page 13: Led Indicators

    NPort IA5150/5250 Series User’s Manual Getting Started LED Indicators The top panels of all NPort IA5150/5250 device servers have four LED indicators, as described in the following table. LED Name LED Color LED Function PWR1, Power is being supplied to power input PWR1, PWR2. PWR2 Steady on: Power is on and NPort IA is booting up.

  • Page 14: Chapter 3 Initial Ip Address Configuration

    Initial IP Address Configuration Chapter 3 When setting up your NPort IA5150/5250 for the first time, the first thing you should do is configure the IP address. This chapter introduces the methods that can be used to configure the device server’s IP address. Select one of the initial IP Address configuration methods to configure NPort IA5150/5250’s IP Address.

  • Page 15: Initializing Nport Ia5150/5250’S Ip Address

    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration Initializing NPort IA5150/5250’s IP Address 1. Determine whether your NPort IA5150/5250 needs to use a Static IP or Dynamic IP (either DHCP or BOOTP application). 2. If NPort IA5150/5250 is used in a Static IP environment, you can use NPort IA5150/5250 Administration Suite, ARP, Web Console, Telnet Console, or Serial Console to configure the new IP address.

  • Page 16: Telnet Console

    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration Take the following steps to use ARP to configure the IP address: 1. Obtain a valid IP address for your NPort IA5150/5250 from your network administrator. 2. Obtain NPort IA5150/5250’s MAC address from the label on its bottom panel. 3.

  • Page 17
    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration 4. Type 2 to select Network settings, and then press Enter. 5. Type 1 to select IP address and then press Enter. 6. Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter.
  • Page 18
    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration 7. Press any key to continue. 8. Type m and then press Enter to return to the main menu. 9. Type s and then press Enter to Save/Restart the system. 10. Type y and then press Enter to save the new IP address and restart NPort IA5150/5250.
  • Page 19: Serial Console (19200, N, 8, 1)

    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration Serial Console (19200, n, 8, 1) You may use the RS-232 console port to set up the IP address for NPort IA5150/5250. We suggest using PComm Terminal Emulator, which is available free of charge as part of the PComm Lite program suite, to carry out the installation procedure, although other similar utilities may also be used.

  • Page 20
    NPort IA5150/5250 Series User’s Manual Initial IP Address Configuration 6. Press the “ ` ” key continuously and then power on the NPort IA5150/5250. 7. NPort IA5150/5250 will automatically switch from data mode to console mode as it receives a continuous string of “…
  • Page 21: Choosing The Proper Operation Mode

    Choosing the Proper Operation Mode Chapter 4 In this chapter, we describe the various NPort IA5150/5250 operation modes. The options include an operation mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP socket programming concepts. After choosing the proper operation mode in this chapter, refer to Chapter 5 for detailed configuration parameter definitions.

  • Page 22: Overview

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode Overview NPort IA5150/5250 Serial Device Servers network-enable traditional RS-232/422/485 devices, in which a Serial Device Server is a tiny computer equipped with a CPU, real-time OS, and TCP/IP protocols that can bi-directionally translate data between the serial and Ethernet formats. Your computer can access, manage, and configure remote facilities and equipment over the Internet from anywhere in the world.

  • Page 23: Tcp Server Mode

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode ATTENTION The driver used for Real COM Mode comes with the NPort IA5150/5250 NPort Administrator. The driver is installed automatically on your computer when you install NPort IA5150/5250 Administration Suite. One of the major conveniences of using Real COM Mode is that Real COM Mode allows users to continue using RS-232/422/485 serial communications software that was written for pure serial communications applications.

  • Page 24: Tcp Client Mode

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode TCP Client Mode In TCP Client mode, NPort IA5150/5250 can TCP Client Mode actively establish a TCP connection to a pre-defined host computer when serial data arrives. After the data has been transferred, NPort IA5150/5250 can automatically disconnect from the host computer by using the TCP alive check TCP/IP…

  • Page 25: Ethernet Modem Mode

    NPort IA5150/5250 Series User’s Manual Choosing the Proper Operation Mode Ethernet Modem Mode Ethernet Modem Mode is designed for use with legacy operating systems, such as MS-DOS, that do not support TCP/IP Ethernet. By connecting one of NPort IA5150/5250’s serial port to the MS-DOS computer’s serial port, it is possible to use legacy software originally designed to transmit data via modem, but now transmit the data over the Ethernet.

  • Page 26: Web Console Configuration

    Web Console Configuration Chapter 5 The Web Console is the most user-friendly method available to configure NPort IA5150/5250. In this chapter, we introduce the Web Console function groups and function definitions. The following topics are covered in this chapter: Opening Your Browser Basic Settings Network Settings Serial Settings…

  • Page 27: Opening Your Browser

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Opening Your Browser 1. Open your browser with the cookie function enabled. (To enable your browser for cookies, right click on your desktop Internet Explorer icon, select Properties, click on the Security tab, and then select the three Enable options as shown in the figure below.) 2.

  • Page 28
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION If you use other web browsers, remember to Enable the functions to “allow cookies that are stored on your computer” or “allow per-session cookies.” NPort IA5150/5250 uses cookies only for “password” transmission. ATTENTION Refer to Chapter 3, “Initial IP Address Configuration,”…
  • Page 29: Basic Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION If you can’t remember the password, the ONLY way to start configuring NPort IA5150/5250 is to load factory defaults by using the Reset button. Remember to use NPort Administrator to export the configuration file when you have finished the configuration.

  • Page 30
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION First time users should select the time zone first. The Console will display the “real time” according to the time zone compared to GMT. If you would like to modify the real time clock, select “Local time.” NPort IA5150/5250’s firmware will modify the GMT time according to the Time Zone.
  • Page 31: Network Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Web console Setting Factory Default Necessity Enable or Disable Enable Required Telnet console Setting Factory Default Necessity Enable or Disable Enable Required ATTENTION If you disable both the “Web console” and “Telnet console,” you can still use NPort Administrator to configure NPort IA5150/5250 either locally or remotely over the network.

  • Page 32
    NPort IA5150/5250 Series User’s Manual Web Console Configuration You must assign a valid IP address to NPort IA5150/5250 before it will work in your network environment. Your network system administrator should provide you with an IP address and related settings for your network. The IP address must be unique within the network (otherwise, NPort IA5150/5250 will not have a valid connection to the network).
  • Page 33: Snmp Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration IP configuration Setting Factory Default Necessity Static Static Required DHCP DHCP/BOOTP BOOTP ATTENTION In Dynamic IP environments, the firmware will retry 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server. The Timeout for each try increases from 1 second, to 3 seconds, to 5 seconds.

  • Page 34: Ip Address Report

    NPort IA5150/5250 Series User’s Manual Web Console Configuration The SNMP contact information usually includes an emergency contact name and telephone or pager number. Location Setting Factory Default Necessity 1 to 39 characters None Optional (E.g., Floor 1, office 2) Specify the location string for SNMP agents such as NPort IA5150/5250. This string is usually set to the street address where the NPort IA5150/5250 is physically located.

  • Page 35: Serial Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Serial Settings Click on Serial Settings, located under Main Menu, to display serial port settings for ports 1 and 2. To modify serial settings for a particular port, click on either Port 1 or Port 2 under Serial Settings, located under Main Menu on the left side of the browser window.

  • Page 36: Operating Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Baud rate Setting Factory Default Necessity 110 bps to 230400 bps 115200 bps Required Data bits Setting Factory Default Necessity 5, 6, 7, 8 Required When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits. Stop bits Setting Factory Default…

  • Page 37: Real Com Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Real COM Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort IA5150/5250 automatically closes the TCP connection if there is no TCP activity for the given time.

  • Page 38
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION When Max connection is set to 2, 3, or 4, this means that NPort IA5150/5250 will be using a “multi connection application” (i.e., 2, 3, or 4 hosts are allowed access to the port at the same time).
  • Page 39
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1 KB, the NPort IA5150/5250 will automatically pack the data and send it to the Ethernet.
  • Page 40: Tcp Server Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration TCP Server Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort IA5150/5250 automatically closes the TCP connection if there is no TCP activity for the given time.

  • Page 41
    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION The Inactivity time should at least be set larger than that of Force transmit timeout. To prevent the unintended loss of data due to the session being disconnected, it is highly recommended that this value is set large enough so that the intended data transfer is completed.
  • Page 42
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Delimiter 2 Setting Factory Default Necessity 00 to FF (hex) None Optional Once the NPort IA5150/5250 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort IA5150/5250’s Ethernet port. ATTENTION Delimiter 2 is optional.
  • Page 43: Tcp Client Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration NPort IA5150/5250 should send that series of characters during a time interval less than the Force transmit timeout for NPort IA5150/5250, and the total length of data must be less than or equal to NPort IA5150/5250’s internal buffer size.

  • Page 44
    NPort IA5150/5250 Series User’s Manual Web Console Configuration TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort IA5150/5250 closes the TCP connection automatically if there is no TCP activity for the given time.
  • Page 45
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Packing length Setting Factory Default Necessity 0 to 1024 Optional Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes.
  • Page 46
    NPort IA5150/5250 Series User’s Manual Web Console Configuration only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout. The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate.
  • Page 47
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Connection control Setting Factory Default Necessity Startup/None, Startup/None Required Any Character/None, Any Character/Inactivity Time, DSR ON/DSR OFF, DSR ON/None, DCD ON/DCD OFF, DCD ON/None The meaning of each of the above settings is given in the table below. In general, both the Connect condition and Disconnect condition are given.
  • Page 48: Udp Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration UDP Mode Packing length Setting Factory Default Necessity 0 to 1024 Optional Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes.

  • Page 49
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Delimiter process Setting Factory Default Necessity Do nothing Delimiter + 1 Do Nothing Optional Delimiter + 2 Strip Delimiter [Delimiter + 1] or [Delimiter + 2]: The data will be transmitted when an additional byte (for Delimiter +1), or an additional 2 bytes (for Delimiter +2) of data is received after receiving the Delimiter.
  • Page 50: Pair Connection Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Destination IP address 2/3/4 Setting Factory Default Necessity IP address range Begin: Empty Optional E.g., Begin: 192.168.1.11 End: Empty End: 192.168.1.20 Port: 4001 Local listen port Setting Factory Default Necessity 1 to 65535 4001 Required The UDP port that NPort IA5150/5250 listens to, and that other devices must use to contact NPort…

  • Page 51: Pair Connection Slave Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Destination IP address Setting Factory Default Necessity IP address or Domain Name blank Optional (E.g., 192.168.1.1) TCP port No. 4001 Required The Pair Connection “Master” will contact the network host that has this IP address. Data will be transmitted through the port No.

  • Page 52: Ethernet Modem Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Ethernet Modem Mode Dial-in NPort IA5150/5250 listens for a TCP/IP connection request from the remote Ethernet modem or host. NPort IA5150/5250’s response depends on the ATS0 value, as outlined below. ATS0=0 (default): NPort IA5150/5250 will temporarily accept the TCP connection and then send the “RING”…

  • Page 53
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Ethernet Modem Setting Value Notes Necessity The TCP port that other devices must use to contact this device. To avoid conflicts with TCP port valid port No. Required standard TCP ports, the default is set to 4001. TCP connection is not closed due to an idle serial line.
  • Page 54
    NPort IA5150/5250 Series User’s Manual Web Console Configuration 16 AT&D Serial port DTR control AT&D0=recognize DTE always ready AT&D1, AT&D2=reply DTE when DTR On (default) 17 AT&F Restore manufacturer’s settings 18 AT&G Select guard time reply “OK” only 19 AT&R Serial port RTS option command reply “OK”…
  • Page 55: Reverse Telnet Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The TCP port that other devices must use to contact this device. To avoid conflicts with standard TCP ports, the default is set to 4001. Reverse Telnet Mode TCP alive check time Setting…

  • Page 56: Disabled Mode

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Disabled Mode When Operation mode is set to Disabled, that particular port will be disabled. Check the “Apply the above settings to all serial ports” to apply this setting to the other port. Accessible IP Settings NPort IA5150/5250 uses an IP address based filtering method to control access to itself.

  • Page 57: Auto Warning Settings

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Allowable Hosts Input format Any host Disable 192.168.1.120 192.168.1.120 / 255.255.255.255 192.168.1.1 to 192.168.1.254 192.168.1.0 / 255.255.255.0 192.168.0.1 to 192.168.255.254 192.168.0.0 / 255.255.0.0 192.168.1.1 to 192.168.1.126 192.168.1.0 / 255.255.255.128 192.168.1.129 to 192.168.1.254 192.168.1.128 / 255.255.255.128 Auto Warning Settings Auto warning: E-mail and SNMP trap…

  • Page 58: Event Type

    NPort IA5150/5250 Series User’s Manual Web Console Configuration ATTENTION Consult your Network Administrator or ISP for the proper mail server settings. The Auto warning function may not work properly if it is not configured correctly. NPort IA5150/5250 SMTP AUTH supports LOGIN, PLAIN, CRAM-MD5 (RFC 2554). SNMP Trap Server SNMP trap server IP or domain name Setting…

  • Page 59
    NPort IA5150/5250 Series User’s Manual Web Console Configuration Password changed The user has changed NPort IA5150/5250’s password. When the password changes, NPort IA5150/5250 will send an e-mail with the password changed notice before NPort IA5150/5250 reboots. If the NPort IA5150/5250 is unable to send an e-mail message to the mail server within 15 seconds, NPort IA5150/5250 will reboot anyway, and abort the e-mail auto warning.
  • Page 60
    NPort IA5150/5250 Series User’s Manual Web Console Configuration DCD changed A change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, If the DCD signal changes to low, it means that the connection line is down. When the DCD signal changes to low, NPort IA will immediately send a warning.
  • Page 61: Monitor

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Monitor Monitor Line Click on Line under Monitor to show the operation mode and status of each connection (IPx), for each of the two serial ports. Monitor Async Click on Async under Monitor to show the current status of each of the two serial ports. Monitor Async-Settings Click on Async Setting under Monitor to show the run-time settings for each of the two serial ports.

  • Page 62: Change Password

    NPort IA5150/5250 Series User’s Manual Web Console Configuration Change Password Input the “Old password” and “New password” to change the password. Leave the password boxes blank to erase the password. If the password is erased, then NPort IA5150/5250 will not have password protection.

  • Page 63: Configuring Nport Administrator

    Configuring NPort Administrator Chapter 6 The following topics are covered in this chapter: Overview Installing NPort Administrator Configuration Broadcast Search Unlock Password Protection Configuring NPort IA5150/5250 Upgrading the Firmware Export Configuration Import Configuration Monitor Port Monitor COM Mapping On-line COM Mapping Off-line COM Mapping IP Location…

  • Page 64: Overview

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Overview Device Server Administrator lets you install and configure your NPort IA5150/5250 Series products easily over the network. Five function groups are provided to ease the installation process, allow off-line COM mapping, and provide monitoring and IP location server functions. Device Server Administrator is an integrated software suite that bundles Device Server Administrator and the IP Serial Library, and provides everything you need to manage, monitor, and modify your NPort IA5150/5250 from a remote location.

  • Page 65
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. Click on Next to install the program using the default program name, or select a different name. 4. Click on Install to proceed with the installation.
  • Page 66
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 5. The Installing window reports the progress of the installation. 6. Click on Next to proceed with the installation.
  • Page 67: Configuration

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 7. Click on Finish to complete the installation of NPort IA5150/5250 Administration Suite. Configuration The Administrator-Configuration window is divided into four parts. The top section contains the function list and online help area. (Windows NT does not support this .chm file format.) The five Administrator function groups are listed in the left section.

  • Page 68: Broadcast Search

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Broadcast Search The Broadcast Search function is used to locate all NPort IA5150/5250s that are connected to the same LAN as your computer. Since the Broadcast Search function searches by MAC address and not IP address, all NPort IA5150/5250s connected to the LAN will be located, regardless of whether or not they are part of the same subnet as the host.

  • Page 69: Unlock Password Protection

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator ATTENTION Before modifying NPort IA5150/5250’s configuration, use Broadcast Search to locate all NPort IA5150/5250s connected to the LAN, or use Specify by IP Address to locate a particular NPort IA5150/5250. Unlock Password Protection If the NPort IA5150/5250 is password protected (indicated by “Lock”…

  • Page 70: Configuring Nport Ia5150/5250

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. The “Lock” status will change to “Unlock,” and the Administrator utility will keep this NPort IA5150/5250 in the Unlock status throughout this Administrator session. The meanings of the six “Status” states are given below (note that the term Fixed is borrowed from the standard fixed IP address networking terminology): Lock The NPort IA5150/5250 is password protected, “Broadcast Search”…

  • Page 71
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 2. Unlock the NPort IA5150/5250 you wish to configure if it is password protected. Right click on the NPort IA5150/5250 and select Configure to start the configuration. 3. The progress bar shows that Administrator is retrieving configuration information from the specific NPort IA5150/5250.
  • Page 72: Upgrading The Firmware

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 5. You will now be able to modify Time Zone, Local Date, Local Time, and Time Server. ATTENTION You can simultaneously modify the configurations of multiple NPort IA5150/5250s that are of the same model. To select multiple NPort IA5150/5250s, hold down the Ctrl key when selecting additional NPort IA5150/5250s, or hold down the Shift key to select a group of NPort IA5150/5250s.

  • Page 73
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 2. Unlock the NPort IA5150/5250 you wish to configure if it is password protected. Right click on a specific NPort IA5150/5250 and select the Upgrade Firmware function to start upgrading the firmware. 3.
  • Page 74: Export Configuration

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Export Configuration To export the configuration of an NPort IA5150/5250, right click on the NPort IA5150/5250 and select Export Configuration and then follow the onscreen instructions. The Export Configuration function is a handy tool that can be used to produce a text file containing the current configuration of a particular NPort IA5150/5250.

  • Page 75: Monitor

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator ATTENTION You can simultaneously import the same configuration file into multiple NPort IA5150/5250s that are of the same model. To select multiple NPort IA5150/5250s, hold down the Ctrl key when selecting an additional NPort IA5150/5250, or hold down the Shift key to select a block of NPort IA5150/5250s.

  • Page 76
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator Monitor Add Target Rescan 1. Click on Monitor under Function. 2. Click on Monitor Add Target from the menu bar, or click the right mouse button and select Add Target. 3. Click on Rescan. 6-14…
  • Page 77
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 4. Select your targets from the list, and then click on OK. Once the Monitor function is running: 1. The NPort IA5150/5250 list will appear on the Monitor screen. 2. Right click the panel and select Settings. 6-15…
  • Page 78
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. Select or de-select Monitor Items. Use the single arrowhead buttons to move highlighted items from one box to the other. Use the double arrowhead buttons to move all items in one box to the other.
  • Page 79
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 5. On the Advanced Settings page, select Display warning message for new event and/or Play warning music for new event. In the second case, you must enter the path to the WAV file that you want to be played.
  • Page 80
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 8. When one of the NPort IA5150/5250s loses connection with the Monitor program, a warning alert will display automatically. The warning music will be played at the same time. 9. In the Monitor screen, you can see that the NPort IA5150/5250s that are “Not Alive” are shown in red color.
  • Page 81: Port Monitor

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 11. The NPort IA5150/5250s that were reconnected, and are now “Alive,” will be shown in black color. Port Monitor The process described here is the same as in the previous “Monitor” section. The only difference is that you can select more items under Port Monitor than under Monitor.

  • Page 82: Com Mapping

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator COM Mapping Windows Administration Suite comes with Windows 95/98/ME/NT/2000/XP Real COM drivers. After you install NPort IA5150/5250 Administration Suite, there are two ways to set up the NPort IA5150/5250 serial port as your host’s remote COM port. The first way is with On-line COM Mapping.

  • Page 83
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 3. Add the target to which you would like to map COM ports. 4. The NPort IA5150/5250 list that appears is the list generated by the previous Broadcast Search. Select the NPort IA5150/5250 to which you would like to map COM ports. 5.
  • Page 84
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 6. Select the COM No. COM ports that are “In use” or “Assigned” will also be indicated in this drop-down list. If you select multiple serial ports or multiple NPort IA5150/5250s, remember to check the “Auto Enumerating”…
  • Page 85
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator function, the NPort driver will keep querying NPort’s firmware several times to make sure there is really no data queued in the NPort firmware buffer, rather than just flushing the local buffer. This kind of design is used because of some special considerations. However, it might take more time (on the order of several hundred milliseconds) than a native COM1, because it needs to work via Ethernet.
  • Page 86
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 9. After setting the COM Mapping, remember to select Apply Change to save the information in the host system registry. The host computer will not have the ability to use the COM port until after Apply Change is selected.
  • Page 87: Off-Line Com Mapping

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 11. To save the configuration to a text file, select Export COM Mapping. You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host.

  • Page 88
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 2. Modify the port settings as needed. 3. Right click in the NPort list section and select Apply Change. 6-26…
  • Page 89: Ip Location

    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator IP Location When NPort IA5150/5250 is used in a dynamic IP environment, users must spend more time with IP management tasks. NPort IA5150/5250 Series products help out by periodically reporting their IP address to the IP location server, in case the dynamic IP has changed. 1.

  • Page 90
    NPort IA5150/5250 Series User’s Manual Configuring NPort Administrator 4. Click Go to start receiving the Auto IP address report from the NPort IA5150/5250 6-28…
  • Page 91: Ip Serial Lib

    IP Serial LIB Chapter 7 The following topics are covered in this chapter: Overview IP Serial LIB Function Groups Example Program…

  • Page 92: Overview

    NPort IA5150/5250 Series User’s Manual IP Serial LIB Overview What is IP Serial Library? IP Serial Library is a Windows library with frequently used serial command sets and subroutines. IP Serial Library is designed to reduce the complexity and poor efficiency of serial communication over TCP/IP.

  • Page 93: Ip Serial Lib Function Groups

    NPort IA5150/5250 Series User’s Manual IP Serial LIB IP Serial LIB Function Groups Server Control Port Control Input/Output Data Port Status Miscellaneous Inquiry nsio_init nsio_open nsio_read nsio_lstatus nsio_break nsio_end nsio_close nsio_SetReadTimeouts nsio_data_status nsio_break_on nsio_resetserver nsio_ioctl nsio_write nsio_break_off nsio_checkalive nsio_flowctrl nsio_SetWriteTimeouts nsio_breakcount nsio_DTR nsio_RTS…

  • Page 94: Appendix A Pinouts And Cable Wiring

    Pinouts and Cable Wiring Appendix A The following topics are covered in this appendix: Port Pinout Diagrams RS-232/422/485 (male DB9) Pinouts 4W/2W RS-485/RS-422 (Terminal Block) Pinouts Power Input and Relay Output Pinouts Cable Wiring Diagrams Serial Cables…

  • Page 95: Port Pinout Diagrams

    NPort IA5150/5250 Series User’s Manual Pinouts and Cable Wiring Port Pinout Diagrams RS-232/422/485 (male DB9) Pinouts 1 2 3 4 5 6 7 8 9 RS-422/ RS-232 RS-485 (2W) RS-485 (4W) TxD-(A) TxD+(B) RxD+(B) Data+(B) RxD-(A) Data-(A) 4W/2W RS-485/RS-422 (Terminal Block) Pinouts RS-422/ RS-485 (2W) RS-485 (4W)

  • Page 96: Cable Wiring Diagrams

    NPort IA5150/5250 Series User’s Manual Pinouts and Cable Wiring Cable Wiring Diagrams Serial Cables Female DB9 to Male DB9 Male DB9 Female DB9 Male DB9 Female DB9 RS-232 NPort IA Device Cable Wiring 9 pins 9 pins Female DB9 to Male DB25 Male DB9 Female DB9 Male DB25…

  • Page 97: Appendix B Well Known Port Numbers

    Well Known Port Numbers Appendix B In this appendix, which is included for your reference, we provide a list of Well Known port numbers that may cause network problems if you set NPort IA5150/5250 to one of these ports. Refer to RFC 1700 for Well Known port numbers, or refer to the following introduction from the IANA.

  • Page 98
    NPort IA5150/5250 Series User’s Manual Well Known Port Numbers TCP Socket Application Service Whois (nickname) (Login Host Protocol) (Login) Domain Name Server (domain) Finger protocol (Finger) World Wibe Web HTTP Netword news Transfer Protocol (NNTP) Network Time Protocol 160 – 223 Reserved for future use UDP Socket Application Service…
  • Page 99
    SNMP Agents with MIB II & RS-232 Appendix C like groups NPort IA5150/5250 has built-in SNMP (Simple Network Management Protocol) agent software that supports SNMP Trap, RFC1317 RS-232 like groups and RFC 1213 MIB-II. The following table lists the standard MIB-II groups, as well as the variable implementation for NPort IA5150/5250.
  • Page 100
    NPort IA5150/5250 Series User’s Manual SNMP Agents System MIB Interfaces MIB IP MIB ICMP MIB SysServices ifInUnknownProtos ipReasmFails IcmpOutTimeExcds ifOutOctets ipFragOKs IcmpOutParmProbs ifOutUcastPkts ipFragFails IcmpOutSrcQuenchs ifOutNUcastPkts ipFragCreates IcmpOutRedirects ifOutDiscards ipAdEntAddr IcmpOutEchos ifOutErrors ipAdEntIfIndex IcmpOutEchoReps ifOutQLen ipAdEntNetMask IcmpOutTimestamps ifSpecific ipAdEntBcastAddr IcmpOutTimestampReps ipAdEntReasmMaxSize IcmpOutAddrMasks IpNetToMediaIfIndex…
  • Page 101
    NPort IA5150/5250 Series User’s Manual SNMP Agents Address Translation MIB TCP MIB SNMP MIB AtNetAddress tcpRetransSegs snmpInTotalSetVars tcpConnState snmpInGetRequests tcpConnLocalAddress snmpInGetNexts tcpConnLocalPort snmpInSetRequests tcpConnRemAddress snmpInGetResponses tcpConnRemPort snmpInTraps tcpInErrs snmpOutTooBigs tcpOutRsts snmpOutNoSuchNames snmpOutBadValues snmpOutGenErrs snmpOutGetRequests snmpOutGetNexts snmpOutSetRequests snmpOutGetResponses snmpOutTraps snmpEnableAuthenTraps RFC1317: RS-232 MIB objects RS-232-like General Port RS-232-like Asynchronous Generic RS-232-like Group…
  • Page 102
    NPort IA5150/5250 Series User’s Manual SNMP Agents The Input Signal Table The Output Signal Table rs232InSigTable rs232OutSigTable rs232InSigEntry rs232OutSigEntry rs232InSigPortIndex rs232OutSigPortIndex rs232InSigName rs232OutSigName rs232InSigState rs232OutSigState…
  • Page 103
    Auto IP Report Protocol Appendix D NPort Series provides several ways to configure Ethernet IP addresses. One is DHCP Client. When you set up NPort to use DHCP Client to configure Ethernet IP addresses, it will automatically send a DHCP request over the Ethernet to find the DHCP Server. And then the DHCP Server will send an available IP address to the NPort.
  • Page 104: Appendix D Auto Ip Report Protocol

    NPort IA5150/5250 Series User’s Manual Auto IP Report Protocol Auto IP Report Format “MOXA”, 4 bytes Info[0] Info[1] … Info[n] Info [n] Field Length Data Variable, Length is “Length Field” Length ID List ID Value Description Length Note Server Name Variable ASCII char Hardware ID…

  • Page 105: Appendix E Service Information

    Service Information Appendix E This appendix shows you how to contact Moxa for information about this and other products, and how to report problems. In this appendix, we cover the following topics. MOXA Internet Services Problem Report Form Product Return Procedure…

  • Page 106: Moxa Internet Services

    NPort IA5150/5250 Series User’s Manual Service Information MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, driver updates, product information, and user’s manual updates.

  • Page 107: Problem Report Form

    NPort IA5150/5250 Series User’s Manual Service Information Problem Report Form MOXA NPort IA5150/5250 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product: NPort IA5150 NPort IA5150-M-SC NPort IA5150-S-SC NPort IA5150I NPort IA5150I-M-SC NPort IA5150I-S-SC NPort IA5250 2. Serial Number: _________________ Problem Description: Please describe the symptoms of the problem as clearly as possible, including any error messages you see.

  • Page 108: Product Return Procedure

    NPort IA5150/5250 Series User’s Manual Service Information Product Return Procedure For product repair, exchange, or refund, the customer must: Provide evidence of original purchase. Obtain a Product Return Agreement (PRA) from the sales representative or dealer. Fill out the Problem Report Form (PRF). Include as much detail as possible for a shorter product repair time.

Артикул:
NPort 5250Ai-M12

Официальный дистрибьютор MOXA в России

Ethernet сервер последовательных интерфейсов / 2xRS-232/422/485 / разъемы М12 / EN 50155 / –25…+55°C — MOXA NPort 5250Ai-M12

Цены указаны с НДС

1118,9 USD

Доступно к заказу

Нашли дешевле?

Оплата

Оплата

По счету, банковской картой, наличными и QR. Подробнее

Конcультируйтесь +7 (343) 381-75-75, отправляйте спецификации ipcsales@aveon.ru

АВЕОН – дистрибьютор АСУ и IT | Собственное производство защищенных ПК
Техподдержка | Гарантия | Сервис | Доставка по России от 1 дня!
Самовывоз: Екатеринбург, Челябинск, Пермь, Тюмень, Ханты-Мансийск, Сургут

  • Характеристики
  • Документация
  • Зарегистрировать проект
  • Оплата и доставка

Характеристики

Конструктивное исполнение

  • Конструктив корпусаМеталлический корпус
  • Вид монтажаНастольный, Монтаж на стене
  • Защита корпуса по IPIP40

Интерфейсы ввода-вывода

  • Общее количество COM-портов2
  • Портов RS-232/422/4852
  • Максимальная скорость COM-портов RS-232/422/485921600 Бит/с
  • Тип разъема COM-портов2xDB9M

Сетевые интерфейсы

  • Количество Ethernet портов1
  • Портов 10/100 Megabit/s1
  • Разъем порта 10/100 Megabit/sM12

Сетевые протоколы

  • ПротоколыIGMPv1/v2, SMTP, BootP, HTTP, LLDP, Telnet, ICMP, TCP, UDP, DHCP, DNS, SNMP V1
  • Версия протокола IPIPv4

Охлаждение

  • Тип охладителяБезвентиляторный

Индикаторы и органы управления

  • ИндикаторыИндикатор питания, LED индикаторы 10/100M, LED индикатор READY, LED индикатор COM-портов
  • Установка режимов работыВ сети через Telnet, Web-интерфейс

Требования по питанию

  • Входное напряжение питания. Постоянный ток12 … 48 В
  • Потребляемая мощность4.32 Вт
  • Ток потребления360 мА

Программное обеспечение

  • Совместимость с операционными системамиLinux kernel 2.6, Windows CE 5.0, Windows CE 6.0, Windows Server 2003, Windows Server 2008, Windows XP, Windows XP Embedded, Windows 7, Windows 8, Linux kernel 2.4, Linux kernel 3.x, Windows 95, Windows 98, Windows ME, Windows NT, Windows 2000, Windows Vista, Windows 8.1, Unix, Open Server, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X

Условия эксплуатации

  • Рабочая температура-25 … 55 °С
  • Допустимая влажность эксплуатации5 … 95 %
  • Время наработки на отказ639622 ч

Условия хранения

  • Температура хранения-40 … 85 °С

Габариты

  • Ширина80 мм
  • Высота216.6 мм
  • Глубина52.9 мм

Стандарты и сертификаты

  • СертификатыCE, FCC
  • Вибрация и ударМЭК 60068-2-6
  • БезопасностьUL 60950-1, EN 60950-1
  • Электромагнитная совместимость (EMS)EN 55024
  • Электромагнитные помехи (EMI)EN 55022 Class A, FCC Part 15 Subpart B Class A
  • Железнодорожный транспортEN 50121-4, EN 50155

Производство

  • ПроизводительMOXA
  • СерияСерия MOXA NPort 5250

Зарегистрировать проект

Зарегистрируйте проект, чтобы купить по специальной цене.

АВЕОН напрямую сотрудничает с производителями, поэтому вы можете зафиксировать проект за вашей организацией или за конечным заказчиком, получить скидку, запросить увеличение гарантийного срока.


Напоминаем, что все цены, опубликованные на данном сайте, приведены как справочная информация, не являются публичной офертой, определяемой положениями статьи 437 Гражданского кодекса Российской Федерации, и могут быть изменены в любое время без предупреждения.

Сертифицированные специалисты БЕСПЛАТНО помогут подобрать оборудование под ваш проект, составить спецификацию промышленного компьютера, порекомендуют актуальные замены для снятых с производства компонентов. Позвоните +7 (343) 381-75-75, напишите на ipcsales@aveon.ru или постучитесь в ЧАТ.

Вы можете заказать оборудование для тестирования на вашем предприятии, чтобы оценить характеристики и совместимость с уже установленными устройствами.


Самые ходовые компоненты АСУ ТП всегда на складе в Екатеринбурге и в Москве. Под заказ – 2 недели со склада в Тайване (при наличии у производителя). Самовывоз в Екатеринбурге, Челябинске, Тюмени и Перми. Доставка по России.

Условия оплаты

  • Оплата заказов с сайта по безналичному расчету осуществляется по счету-оферте, который действителен в день его создания. В случае оплаты в последующие дни, стоимость заказа может быть пересчитана на дату оплаты по текущему курсу USD как ЦБ+2% по решению поставщика. При оплате по безналичному расчету с физических лиц может сниматься комиссия банка от 1%.
  • Можно оплатить заказ наличными в офисе АВЕОН или при доставке курьером до двери.
  • После оплаты выдается кассовый чек.

Условия доставки

  • Доставка во все регионы России транспортными компаниями до терминала ТК в городе доставки, либо до двери заказчика.
  • Срок доставки и стоимость определяются тарифами компаний-грузоперевозчиков.
  • Также вы можете самостоятельно забрать товары из пунктов самовывоза в вашем городе.

Более подробная информация
здесь.

  • Промышленные компьютеры

    • ПК в стойку 19″

    • ПК настенно-настольного исполнения

    • Серверы

    • Панельные ПК и рабочие станции

    • Мобильные решения

    • Мониторы и LCD-панели

    • Клавиатуры

  • Встраиваемые решения

    • Встраиваемые компьютеры

    • Встраиваемые процессорные платы

    • Оборудование Compact PCI

    • Оборудование PXI/PXIe

    • AdvancedTCA

    • Процессорные модули и базовые платы

  • Коммуникационное оборудование

    • Промышленные коммутаторы

    • Серверы последовательных интерфейсов

    • Конвертеры и повторители

    • Медиаконвертеры Ethernet Fiber

    • Шлюзы протоколов

    • Мультипортовые платы

    • Беспроводное оборудование

    • KVM-решения

    • Системы видеонаблюдения

  • Системы сбора данных и управления

    • Датчики, измерители

    • Контроллеры

    • Модули удаленного ввода-вывода

    • Платы ввода-вывода

    • Панели оператора

    • Платы и модули АЦП/ЦАП, крейты L-Card

    • Нормализаторы сигналов

    • Корзины расширения

    • Выносные и платы клеммников

  • Комплектующие для промПК, сетей и АСУ

    • Корпусы

    • Объединительные платы

    • Материнские платы

    • Источники и адаптеры питания

    • Накопители

    • Оперативная память

    • Платы клеммников

    • Разъемы и переходники

    • Кабели

    • Элементы крепежа

    • Аксессуары к нормализаторам

    • Прочие аксессуары

    • Шкафы, компоненты СКС

  • Программное обеспечение

    • AdAstra TRACE MODE 6

    • MOXA MXview, SoftCmS, SoftNVR

    • ICP DAS Indusoft, ISaGRAF

    • ПО Advantech

    • Aten

    • Kaspersky

    • Microsoft

  • Скидки! Распродажа!

  • Отраслевые решения

    • Реклама

    • ВПК

    • Машинное зрение и IoT

    • Медицина

    • Морское применение

    • Нефтяная и газовая отрасли

    • Транспорт

    • Энергетика

    • Ритейл

Российские промышленные компьютеры iROBO

Будьте в курсе!

Узнавайте о мероприятиях и акциях первым

Преобразователь NPort IA-5250

  • Кратко о товаре
  • Характеристики
  • Файлы
  • Дополнительное оборудование

Преобразователь NPort IA-5250

2-портовый преобразователь RS-232/422/485 в Ethernet

2-портовый преобразователь RS-232/422/485 в Ethernet

  • Количество последовательных портов 2 
  • Тип последовательных портов RS-232 
    RS-422 
    RS-485 
  • Общее количество портов 2
  • Порты Ethernet 2 
  • Интерфейс управления Telnet-консоль 
    Web-интерфейс 
    Windows-утилита 
    Последовательная консоль 
  • Возможность подключения резервного источника электропитания Есть 
  • Рабочая температура, °C 0 ~ +55 
  • Материал корпуса Пластик 
  • Габаритные размеры, мм 29 х 89 х 119

Интерфейс

  • Общее количество портов

    2

Параметры связи

  • Порты Ethernet

    2 

  • Тип разъема

    RJ45 (8 конт.) 

  • Сетевые протоколы

    ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS, SNMP V1, HTTP, SMTP, SNTP

  • Магнитная изоляция Ethernet-портов

    1,5 кВ 

Параметры последовательной связи

  • Количество последовательных портов

    2

  • Тип последовательных портов

    RS-232/422/485 

  • Разъем последовательного порта

    DB9 ‘папа’ 

  • Передаваемые сигналы

    RS-422: TxD+, TxD-, RxD+, RxD-, GND 
    RS-485 (2-проводный): Data+, Data-, GND 
    RS-485 (4-проводный): TxD+, TxD-, RxD+, RxD-, GND 
    RS-232: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND 

  • Бит данных

    5, 6, 7, 8 

  • Четность

    нет, чет, нечет, 0, 1 

  • Стоповые биты

    1, 1.5, 2 

  • Управление потоками данных

    RTS/CTS и DTR/DSR (только RS-232), XON/XOFF 

  • Скорость передачи данных, бит/с

    110 ~ 230400 

  • Управление направлением передачи данных по RS-485

    ADDC® (автоматическое) 

Управление устройством

  • Интерфейс управления

    Telnet-консоль 
    Web-интерфейс 
    Windows-утилита 
    Последовательная консоль 

  • Кнопка Reset

    Есть 

Требования к электропитанию

  • Рабочее напряжение

    12 ~ 48 В пост. 

  • Потребление тока

    435 мА при 12 В

  • Возможность подключения резервного источника электропитания

    Есть 

  • Разъем электропитания

    Клемма 

Условия эксплуатации

  • Рабочая температура, °C

    0 ~ +55 

  • Температура хранения, °C

    -40 ~ +75 

  • Рабочая влажность, %

    5 ~ 95 

Защита

  • Защита от пыли и влаги

    IP30 

Конструктивные свойства

  • Материал корпуса

    Пластик 

Размеры и вес

  • Габаритные размеры, мм

    29 х 89 х 119

  • Вес нетто, кг

    0.38

Монтаж

  • Монтаж

    На DIN-рейку 
    настольный/настенный (опционально) 

Наличие международных сертификатов

  • Безопасность

    UL508 
    UL60950-1 

  • Взрывобезопасность

    IECEx 
    UL/cUL Class 1 Division 2 
    ATEX Zone 2 

  • Электромагнитная совместимость (EMI)

    FCC Part 15 Subpart B Class A 
    CISPR 22 

  • Электромагнитная совместимость (EMS)

    IEC 61000-4-3 RS 
    IEC 61000-4-5 Surge 
    IEC 61000-4-6 CS 
    IEC 61000-4-8 
    IEC 61000-4-2 (ESD) 
    IEC 61000-4-4 (EFT) 

  • Применение в морских системах

    DNV 

  • Удары

    IEC 60068-2-27 

  • Свободное падение

    IEC 60068-2-32 

  • Вибрации

    IEC 60068-2-6 

  • Среднее время наработки на отказ (MTBF), часов

    194765

Гарантийный срок

  • Гарантийный срок

    5 лет 

Комплект поставки

  • Комплект поставки

    Устройство 
    краткое руководство пользователя 

Страница товара на англоязычном сайте

  • Ссылка на сайт moxa.com

Программное обеспечение

Firmware для серии NPort IA-5000 (версия 2.1 от 23.03.2022):  (0,5 Мб) 

Скачать

  • аппаратная версия 2.0 и выше

Firmware для серии NPort IA-5000 (версия 1.7 от 31.03.2021):  (0,5 Мб) 

Скачать

  • аппаратная версия 1.0

Утилита Moxa CLI Configuration Tool для Windows (версия 1.3 от 29.06.2023):  (2 Мб):

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 10
  • Windows 11
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022

Утилита Moxa CLI Configuration Tool для Linux  (версия 1.3 от 29.06.2023):  (11 Мб):

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Linux Kernel 2.6.x
  • Linux Kernel 3.x
  • Linux Kernel 4.x
  • Linux Kernel 5.x

Утилита для поиска устройств (DSU) (версия 2.7 от 28.06.2023):  (2 Мб)

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 10
  • Windows 11
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows 95
  • Windows 98
  • Windows 98 SE
  • Windows ME
  • Windows NT
  • Windows Server 2003
  • Windows Server 2008
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022
  • Windows Vista
  • Windows XP

Драйвер NPort Fixed TTY Driver для Unix (версия 3.5 от 20.03.2012):  (0,1 Мб):

Скачать

  • Mac OS X
  • HP-UX
  • IBM AIX 5.3
  • FreeBSD 7.x/5.x/6.x
  • QNX 4.25
  • QNX 6.x
  • SCO OpenServer 5/6
  • SCO UnixWare 7
  • Sun Solaris 10

Драйвер NPort Real TTY для Linux (Linux 2.x.x) (версия 2.0 от 24.10.2019):  (0,1 Мб)

Скачать

Драйвер NPort Real TTY для Linux (Linux 3.x.x) (версия 3.0 от 24.10.2019):  (0,1 Мб)

Скачать

Драйвер NPort Real TTY для Linux (Linux 4.x) (версия 4.2 от 17.01.2023):  (0,1 Мб)

Скачать

  • Список изменений: скачать (0,1 Мб)

Драйвер NPort Real TTY для Linux (Linux 5.x) (версия 5.2 от 17.01.2023):  (0,1 Мб)

Скачать

  • Список изменений: скачать (0,1 Мб)

Драйвер NPort Real TTY для Linux (Linux Kernel 6.x) (версия 6.0 от 04.05.2023):  (0,1 Мб)

Скачать

  • Список изменений: скачать (0,4 Мб)

Драйвер для macOS 10.12~10.15 (версия 1.1 от 26.09.2022):  (0,6 Кб) 

Скачать

  • Список изменений: скачать (41 Кб) 
  • macOS 10.12
  • macOS 10.13
  • macOS 10.14
  • macOS 10.15

NPort Windows CE Driver Manager (версия 1.6 от 15.11.2012):  (0,2 Мб):

Скачать

  • Windows CE 6.0/5.0

Windows Driver Manager (версия 3.4 от 24.01.2022): (3 Мб)

Скачать

  • Список изменений: скачать (0,4 Мб)
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012 R2
  • Windows Server 2012
  • Windows Server 2016
  • Windows Server 2019

Windows Driver Manager (версия 4.1 от 01.02.2023): (5 Мб)

Скачать

  • Список изменений: скачать (0,4 Мб)
  • Windows 11
  • Windows Server 2022

Windows Driver Manager (версия 2.0 от 31.07.2019): (3 Мб)

Скачать

  • Список изменений: скачать (0,4 Мб)
  • Windows 2000
  • Windows 95
  • Windows 98
  • Windows 98 SE
  • Windows ME
  • Windows NT
  • Windows Server 2003
  • Windows Server 2008
  • Windows Vista
  • Windows XP

Драйвер WinXP Embedded для серии NPort (версия 1.14 от 05.04.2012):  (1 Мб)

Скачать

Библиотека Android API (версия 1.1 от 22.12.2022):  (18 Мб) 

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Android 3.1.x и выше

Программное обеспечение NPort Administration Suite (версия 2.0 от 15.04.2019):  (4 Мб)  

Скачать

Программное обеспечение NPort Administrator Suite для Windows 10 — Server 2019 и более поздних (версия 4.0 от 17.01.2023):  (7 Мб)  

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 10
  • Windows 11
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022

Программное обеспечение NPort Administration Suite для Windows 7 — 8.1 и Windows Server 2008 R2 или более поздних (версия 3.2 от 17.01.2023):  (4 Мб)  

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2

MXview Plug-in для серии NPort 5000 (версия 1.4 от 02.05.2023):  (32 Мб) 

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 10
  • Windows 7
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019

MXconfig Plug-in для серии NPort 5000 (версия 1.1 от 31.03.2021):  (2 Мб) 

Скачать

  • Windows 10
  • Windows 7
  • Windows 8
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2

MXstudio (версия 3.2 от 30.04.2021):  (650 Мб)

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 10
  • Windows 7
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019

MXview (версия 3.2.8 от 31.10.2022):  (417 Мб)

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 7 Service Pack 1 (64-bit)
  • Windows 10 (64-bit)
  • Windows Server 2012 R2 (64-bit)
  • Windows Server 2016 (64-bit)
  • Windows Server 2019 (64-bit)

MXconfig (Java-версия 2.9 от 23.11.2022):  (120 Мб)

Скачать

  • Список изменений: скачать (0,1 Мб)
  • Windows 10
  • Windows 7
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2

Утилита NPort Search (версия 1.15 от 30.06.2014):  (0,9 Мб) 

Скачать

Терминальная утилита PComm Lite для Windows 2000, XP, 2003, Vista, 2008, 7 (x86 и x64) (версия 1.6 от 14.05.2012):  (2 Мб) 

Скачать

Документация

Руководство по аппаратной части (англ.):  (0,8 Мб)

Скачать

Руководство по аппаратной части (рус.):  (0,3 Мб)

Скачать

Руководство пользователя (англ.):  (16 Мб)

Скачать

Руководство по использованию устройств NPort в режиме удаленного виртуального COM-порта компьютера (режим Real COM Mode) (рус.):  (0,9 Мб)

Скачать

Отладка системы передачи данных RS-232/422/485 по сетям Ethernet. Мониторинг устройств NPort (рус.):  (0,6 Мб)

Скачать

Руководство по использованию устройств NPort для «прозрачного» удлинения последовательной линии связи RS-232/422/485 по сетям Ethernet TCP/IP (режим Pair Connection) (рус.):  (0,9 Мб)

Скачать

Настройка функции Force Tx Timeout в устройствах MOXA NPort. Для режимов Real COM, TCP Client, TCP Server, UDP Mode (рус.):  (0,4 Мб)

Скачать

Руководство по безопасности для серии NPort IA5000 (англ.):  (1 Мб)

Скачать

Чертеж для AutoCAD 2D (dwg): (0,3 Мб)

Скачать

Аксессуары

Блок питания MDR-40-24 MOXA 40W/1.7A DIN-Rail 24V VDC power supply, 85 to 264 VAC input, t:-20/+70

Блок питания MDR-60-24 MOXA 60W/2.5A DIN-Rail 24V VDC power supply, 85 to 264 VAC input, t:-20/+70

Переходник Mini DB9F-to-TB Mini DB9 Female to Terminal Block Adapter

Блок питания NDR-120-24 MOXA 120W Din-Rail 24 VDC Power Supply, 90-264VAC/127-370VDC, 5A

Блок питания HDR-60-24 MOXA 60WUltra Slim Step Shape Din-Rail Power Supply 24 VDC 2.5A 85-264VAC 120-370VDC t: -30/70

Материалы по теме

Запись на мероприятие

Технический тренинг по продукции MOXA в Москве
с 29 мая по 31 мая 2019 года, 10:00 — 18:00

Вы успешно записались на мероприятие

Отправить страницу

Чтобы продолжить работу с сайтом на другом устройстве, можете отправить адрес страницы на свой e-mail

Навигация

Спецификация

Сетевые порты

Количество Ethernet-разъемов 2
Количество 10/100 Mb Ethernet 2
Тип коннектора 10/100 Mb Ethernet 2xRJ-45

Порты ввода-вывода

Всего последовательных портов 2
Количество разъемов RS-232/422/485 2

Протоколы связи

Управление SNTP, SMTP, BootP, HTTP, Telnet, TCP, UDP, DHCP, DNS, SNMP V1, Rtelnet
Безопасность ICMP

Способы оповещения и настройки

Индикация Индикатор скорости 10/100 Мбит, Индикатор готовности, Индикатор питания 1, Индикатор питания 2, Индикатор последовательных портов
Метод настройки Telnet, Консольный порт, WEB-консоль

Порты

Тип коннектора DC input (Клеммная колодка)

Электропитание

DC Входное напряжение Min 12 В
DC Входное напряжение Max 48 В
DC Резервное питание Min 12 В
DC Резервное питание Max 48 В

Требования к условиям использования

Минимальная температура при работе Min 0 °C
Максимальная температура при работе Max 60 °C

Реализация корпуса

Внешний вид и материал Пластик
Монтаж На DIN-рейку
IP-защита изделия IP30

Размеры

Ширина 89.2 мм
Глубина 29 мм
Высота 118.5 мм

Сертификация и поддерживаемые стандарты

Стандарт по свободному падению МЭК 60068-2-32
Стандарты по применению на море DNV
Стандарты по суровым условиям Class I Div.2 Groups A, B, C, D, ATEX Zone 2 Ex nC IIC
Стандарты безопасности UL 60950-1, UL 508, EN 60950-1
Стандарты по вибрации и ударам МЭК 60068-2-6, МЭК 60068-2-27
Стандарты по вибрации и ударам МЭК 60068-2-6, МЭК 60068-2-27

Модификации

Часто задаваемые вопросы / FAQ

Если необходимо, чтобы NPort был доступен по публичному IP-адресу в режиме RealCOM, находясь при этом за NAT/Firewall, необходимо настроить функцию проброса портов на маршрутизаторе. Большинство маршрутизаторов поддерживают данную функцию.

В таблицах перечислены наиболее распространенные порты, необходимые для выполнения различных функций на серверах последовательных интерфейсов NPort.

Подробнее

Интерфейс RS-232 обеспечивает обмен информацией между двумя устройствами на расстоянии до 15 метров. Для преодоления это ограничения компания МОХА предлагает два решения: преобразователи RS-232/422/485 в Ethernet или преобразователи RS-232 в RS-422/485.

Подробнее

Для обновления прошивки NPort запустите утилиту NPort Administrator.

Щелкните правой кнопкой мыши на NPort и выберите функцию Upgrade Firmware для запуска обновления прошивки.

Подробнее

Возможные причины и их решение перечислены в статье.
Подробнее

Преобразователи NPort серии 5100A являются улучшенной версией предыдущей модели NPort 5100 и обладают рядом значительных преимуществ.

Подробнее

  1. В режиме Pair Connection передаются все сигналы.
  2. В режиме TCP Server/Client только Rx, Tx.
  3. Если служебные сигналы не используются – разницы нет.

Подробнее

Руководство предназначено для работы NPort в локальной сети. Убедитесь, что ПК и NPort находятся в одной подсети.

Подробнее

Если NPort имеет больше одного COM-порта, возможно организовать резервирование линии Ethernet через сеть сотовой связи с использованием шлюза OnCell. OnCell подключается к одному из COM-портов.

Подробнее

Функция COM Grouping позволяет работать с несколькими устройствам NPort через один виртуальный COM-порт компьютера.

Подробнее

Количество COM-портов зависит от того, какой драйвер используется.

Подробнее

Если у вас есть NPort с двумя или более портами, то вы можете при необходимости переслать данные, приходящие на один из его COM-портов, в другой COM-порт.

Для этого необходимо выбрать режим работы портов TCP Server и TCP Client.

Подробнее

Для сброса пароля и возврата к заводским настройкам NPort нажмите и удерживайте кнопку Reset в течение 5 секунд. Иного способа восстановить забытый пароль NPort не существует.

Подробнее

Стандартный пароль NPort по умолчанию: moxa
(Раньше был пустым).

Подробнее

NPort серии 5000 поддерживает до 4-ех одновременных подключений.
Серии NPort 5000A (Advanced), NPort 6000 и выше поддерживают до 8-ми одновременных подключений.

Подробнее

Чтобы проверить настройки сетевого окружения и настройки NPort, выполните следующие действия.

Подробнее

  1. Найдите распиновку на подключаемое устройство и на NPort. MOXA придерживается стандартов и определяет сигнал B как положительный, а сигнал A как отрицательный. Во всех устройствах MOXA с разъемом DB9 сигнал B выведен на PIN3, сигнал A на PIN4.

Подробнее

Разница между буфером последовательного порта и журналом последовательных данных показана в таблице.

Подробнее

По стандарту RS-232 напряжение сигналов может находиться в пределах от -25 В до +25 В.
Чтобы соответствовать стандарту RS-232, NPort обеспечивает сигнал в диапазоне от -6 В до +6 В.

Подробнее

Это особенность работы NPort Administrator.

Подробнее

NPort позволяет настраивать каждый СОМ-порт индивидуально, поэтому можно, например, настроить 1 порт RS-485 от NPort 5130 на работу с одним из портов RS-232/422/485 в NPort 5650, причем можно RS-232 настроить на RS-485 или RS-422. Поддерживаются режимы подключения Pair Connection, TCP Client, TCP Server и UDP.

Подробнее

Точную цифру назвать сложно, т.к. помимо самих данных в пакеты Ethernet включается дополнительная информация. Поэтому для простоты расчетов можно считать, что передаваемый трафик в 2 раза больше чем трафик по последовательному интерфейсу. Например, вы передаете 1000 бит данных в секунду на какой-то скорости по СОМ порту, значит трафик в Ethernet будет около 1000*2 = 2000 бит/с.

Подробнее

Правильное заземление устройства позволяет снизить электромагнитные помехи и защититься от неправильной работы или выхода из строя самого NPort.

Подробнее

Устройства с питанием от порта RS-232 компьютера получают питание по линиям Tx, RTS и DTR. В общем случае длина кабеля не должна превышать 15 метров на скорости 9600bps.При использовании кабеля большей длины передаваемой мощности может не хватить для питания устройства.

Подробнее

В устройствах MOXA используется стандартная распайка интерфейса RS-232 для разъема DB9 Male.

Подробнее

В устройствах MOXA используется стандартная распайка интерфейса RS-485 для разъема DB9 Male.

Подробнее

Серийный номер — ряд символов, расположенный после слов «Production S/N:»

Подробнее

  1. Для увеличения показателя надежности и продления срока службы источника питания, мы предлагаем использовать блок питания с 30% запасом по мощности. Например, если устройство потребляем 100 Вт, то лучше выбрать блок питания на 130 Вт или больше.

Подробнее

MTBF (среднее время между отказами) является индикатором надежности.
Для расчета значения MTBF MOXA использует стандарт Telcordia (ранее известный как Bellcore).

Значения MTBF можно посмотреть в карточке товара на нашем сайте или в спецификации на оборудование.

Вы также можете получить официальный отчет MTBF, направив обращение на нашу почту russia@moxa.pro

Подробнее

Буква «I» в конце названия модели обозначает наличие гальванической изоляции СОМ порта.

Подробнее

Понравилась статья? Поделить с друзьями:
  • Тримедат мазь инструкция по применению мазь
  • Руководство службой сервиса
  • Бильтрицид инструкция по применению при дифиллоботриозе схема лечения
  • Ип 212 58м извещатель пожарный дымовой инструкция
  • Резорба инструкция по применению цена отзывы аналоги цена