Operating Instructions | EN
Inverter
Inverter i550-Cabinet
0.25 … 132 kW
As easy as that.
Related Manuals for Lenze i550
Summary of Contents for Lenze i550
-
Page 1
Operating Instructions | EN Inverter Inverter i550-Cabinet 0.25 … 132 kW As easy as that. -
Page 2
Hardware overview of the inverter PE connec on X100 Mains connec on/DC bus Relay output Network status LEDs X2xx Network Interface Diagnos c module Memory module Control terminals IT-screws Safety module X105 PTC input Motor connec on X109 Operating Instructions i550-Cabinet… -
Page 3: Table Of Contents
5.6 1-phase mains connection 120 V …………….11 5.7 1-phase mains connection 230/240 V ……………12 5.8 3-phase mains connection 230/240 V ……………13 5.9 3-phase mains connection 400 V …………….14 5.10 3-phase mains connection 480 V …………….16 6 Initial switch-on ………………….18 Operating Instructions i550-Cabinet…
-
Page 4: General Information
The product is designed for the installation into electrical systems or machinery. The i500 product family is designed for the power range of 0.25 … 132 kW. The inverter i550 is suitable for conveyor and travelling drives, pumps, fans, winders, lifting systems and many other machine tasks.
-
Page 5: Identification Of The Products
Design types Standard I/O without network 000S The product may cause EMC interferences. The operator is responsible for executing the (examples) Application I/O without network 001S interference suppression measures. Operating Instructions i550-Cabinet…
-
Page 6: Layout Of Warning Notices
In the event of a short circuit of two power transistors, a residual movement of up to 180°/ number of pole pairs on the motor may occur (e.g. 4-pole motor): residual movement max. 180 °/2 = 90°). Operating Instructions i550-Cabinet…
-
Page 7: Standards And Operating Conditions
200 % for 3 s; 150 % for 60 s (120-V network and 230-V network) TX10 Overload capacity 200 % for 3 s; Heavy Duty: 150 % for 60 s; (400-V network) Light Duty: 125 % for 60 s TX10 Operating Instructions i550-Cabinet…
-
Page 8: Mechanical Installation
75 … 90 Device width (Y not visible in the illustration) I55AExxxF 110 … 132 35.6 Device depth X — X: Hole spacing over center of device Hole dimension for top/bottom fixing Top mounting clearance Bottom mounting clearance Operating Instructions i550-Cabinet…
-
Page 9: Electrical Installation
< 150/300 pF/m ≥ 4 mm²) Control terminals +24 V +10 V 100 mA Alternatively, the motor cable can be shielded on an optional motor shield plate. » » » DC 24 V SELV/PELV (+19.2 … +28.8 V) Operating Instructions i550-Cabinet…
-
Page 10: Control Terminals
Inverter [kW] 0.25 … 132 Connection PTC or thermal contact Front X109 Terminal X109: T1 Back Terminal X109: T2 Sensor types PTC single sensor PTC triplet sensor Thermal contact DC 24 V SELV/PELV (+19.2 … +28.8 V) Operating Instructions i550-Cabinet…
-
Page 11: 1-Phase Mains Connection 120 V
Max. output current (15 s) Operation without mains choke Rated mains current 16.8 22.9 Fuse Characteristic gG/gL or gRL Motor connection Max. rated current Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 1-phase mains connection ≥ 30 mA, type B Operating Instructions i550-Cabinet…
-
Page 12: 1-Phase Mains Connection 230/240 V
AC 208 V … 240 V Circuit breaker Characteristic … 2/PE Max. rated current AC 170 V … 264 V Earth-leakage circuit breaker 45 Hz … 65 Hz 1-phase mains connection ≥ 30 mA, type B Motor connection Operating Instructions i550-Cabinet…
-
Page 13: 3-Phase Mains Connection 230/240 V
Operation without mains choke Rated mains current 13.6 20.6 28.8 Fuse Characteristic gG/gL or gRL Max. rated current Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 30 mA, type B ≥ 300 mA, type B Operating Instructions i550-Cabinet…
-
Page 14: 3-Phase Mains Connection 400 V
Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 30 mA, type B ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 22 kW, a mains choke must be used. Operating Instructions i550-Cabinet…
-
Page 15
Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 22 kW, a mains choke must be used. Operating Instructions i550-Cabinet… -
Page 16: 3-Phase Mains Connection 480 V
Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 30 mA, type B ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 30 kW, a mains choke must be used. Operating Instructions i550-Cabinet…
-
Page 17
Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 30 kW, a mains choke must be used. Operating Instructions i550-Cabinet… -
Page 18: Commissioning
• The analog input X3/AI1 must not be wired or connected to GND. Switch on mains voltage ► Switch on mains voltage and check readiness for operation. Observe LED status displays “RDY” and “ERR” on the inverter front panel. See „LED status“. Operating Instructions i550-Cabinet…
-
Page 19: Functions Of The Keys
3 s. P211.00 7.1.2 Example of the keypad handling Example for DO1 function assignment with parameter P420.02. P430.03 I/O setting GROUP 4 P430.02 P430.02 P210.00 Fct. dig. outputs P420.XX Time DO1 func on P420.02 Operating Instructions i550-Cabinet…
-
Page 20: Extended Terminal Control
A USB module and a standard USB cable (A plug to micro-B plug) is required for this. *P420.02 Release brake GND for analog and digital signals http://www.Lenze.com Relay activated at Relay NO contact *P420.01 Ready for operation Relay common contact Relay NC contact Operating Instructions i550-Cabinet…
-
Page 21: The Most Important Parameters At A Glance
Commissioning The most important parameters at a glance This chapter contains the most important parameters and selections. You can find a detailed description in the commissioning document. http://www.Lenze.com The parameters are divided into the following function groups: • Pxxx.xx group 0: Favorites •…
-
Page 22
V/f characteristic control The control mode is used for speed control of an asynchronous motor via a V/f characteristic with speed feedback. (VFC closed loop) This motor control mode is described in the commissioning manual. http://www.Lenze.com P302.00 V/f characteristic Linear Linear characteristic for drives with constant load torque over the speed. -
Page 23
Reverse rot. dir. Digital input 3 [13] Assignment of a trigger to the “Reverse rotating direction” function. Trigger = TRUE: The setpoint specified is inverted (i.e. the sign is inverted). Trigger = FALSE: No action / deactivate function again. Operating Instructions i550-Cabinet… -
Page 24
• The standard setpoint source for operating mode is selected in P201.01. P440.01 AO1 output area Inhibited Definition of the output range. 0 … 10 V DC 0 … 5 V DC 2 … 10 V DC 4 … 20 mA 0 … 20 mA Operating Instructions i550-Cabinet… -
Page 25
Parameterizable frequency setpoints (preset 2). P450.03 Freq. preset 3 0.0 … 50.0 – 40.0 … 599.0 Hz Parameterizable frequency setpoints (preset 3). P450.04 Freq. preset 4 0.0 … 0.0 … 599.0 Hz Parameterizable frequency setpoints (preset 4). * Default setting dependent on the model Operating Instructions i550-Cabinet… -
Page 26: Group 2: Basic Setting
In progress • When the inverter is switched on, all parameters are automatically loaded from the user memory of the memory module to the RAM Action cancelled memory of the inverter. No access No access (Inverter disabled) Operating Instructions i550-Cabinet…
-
Page 27: Troubleshooting
2. Via P400.04 (default setting of digital input 2). • Cause of error has been eliminated and no blocking time is active. • The error is reset if a signal is applied to digital input 2 (P400.04). Operating Instructions i550-Cabinet…
-
Page 28: Error Codes
• Clean fan and ventilation slots. If required, replace fan. The fans can be unlocked via locking hooks and can then be removed. Error: Motor overtemperature Fault • Check drive sizing. 4310 • Check motor temperature sensor and wiring (X109/T1 and X109/T2). Operating Instructions i550-Cabinet…
-
Page 29
Note: The warning will be reset if the thermal load falls below the warning threshold (P707.08) of — 20 %. Automatic start disabled Fault • Deactivate start command and reset error. FF37 FF85 Keypad full control active Warning • To exit the control mode, press the keypad key. Operating Instructions i550-Cabinet… -
Page 30: Led Status
Fundamental information on project planning and ordering the product Commissioning document Fundamental information for the installation and commissioning of the product Mounting instructions Fundamental information on mounting the product The documents can be found in the Lenze Doc Finder. Operating Instructions i550-Cabinet…
-
Page 31
Further documents Operating Instructions i550-Cabinet… -
Page 32
© 01/2020 | 3.0 Lenze Drives GmbH Postfach 10 13 52, 31763 Hameln Breslauer Straße 3, 32699 Extertal GERMANY HR Lemgo B 6478 Phone: +49 5154 82-0 Fax: +49 5154 82-2800 E-mail: Sales.de@Lenze.com Web: www.Lenze.com Lenze Service GmbH Breslauer Straße 3, 32699 Extertal…
Перейти к контенту
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
Operating Instructions | EN
Inverter
Inverter i550-Cabinet
0.25 … 132 kW
As easy as that.
Related Manuals for Lenze i550
Summary of Contents for Lenze i550
-
Page 1
Operating Instructions | EN Inverter Inverter i550-Cabinet 0.25 … 132 kW As easy as that. -
Page 2
Hardware overview of the inverter PE connec on X100 Mains connec on/DC bus Relay output Network status LEDs X2xx Network Interface Diagnos c module Memory module Control terminals IT-screws Safety module X105 PTC input Motor connec on X109 Operating Instructions i550-Cabinet… -
Page 3: Table Of Contents
5.6 1-phase mains connection 120 V …………….11 5.7 1-phase mains connection 230/240 V ……………12 5.8 3-phase mains connection 230/240 V ……………13 5.9 3-phase mains connection 400 V …………….14 5.10 3-phase mains connection 480 V …………….16 6 Initial switch-on ………………….18 Operating Instructions i550-Cabinet…
-
Page 4: General Information
The product is designed for the installation into electrical systems or machinery. The i500 product family is designed for the power range of 0.25 … 132 kW. The inverter i550 is suitable for conveyor and travelling drives, pumps, fans, winders, lifting systems and many other machine tasks.
-
Page 5: Identification Of The Products
Design types Standard I/O without network 000S The product may cause EMC interferences. The operator is responsible for executing the (examples) Application I/O without network 001S interference suppression measures. Operating Instructions i550-Cabinet…
-
Page 6: Layout Of Warning Notices
In the event of a short circuit of two power transistors, a residual movement of up to 180°/ number of pole pairs on the motor may occur (e.g. 4-pole motor): residual movement max. 180 °/2 = 90°). Operating Instructions i550-Cabinet…
-
Page 7: Standards And Operating Conditions
200 % for 3 s; 150 % for 60 s (120-V network and 230-V network) TX10 Overload capacity 200 % for 3 s; Heavy Duty: 150 % for 60 s; (400-V network) Light Duty: 125 % for 60 s TX10 Operating Instructions i550-Cabinet…
-
Page 8: Mechanical Installation
75 … 90 Device width (Y not visible in the illustration) I55AExxxF 110 … 132 35.6 Device depth X — X: Hole spacing over center of device Hole dimension for top/bottom fixing Top mounting clearance Bottom mounting clearance Operating Instructions i550-Cabinet…
-
Page 9: Electrical Installation
< 150/300 pF/m ≥ 4 mm²) Control terminals +24 V +10 V 100 mA Alternatively, the motor cable can be shielded on an optional motor shield plate. » » » DC 24 V SELV/PELV (+19.2 … +28.8 V) Operating Instructions i550-Cabinet…
-
Page 10: Control Terminals
Inverter [kW] 0.25 … 132 Connection PTC or thermal contact Front X109 Terminal X109: T1 Back Terminal X109: T2 Sensor types PTC single sensor PTC triplet sensor Thermal contact DC 24 V SELV/PELV (+19.2 … +28.8 V) Operating Instructions i550-Cabinet…
-
Page 11: 1-Phase Mains Connection 120 V
Max. output current (15 s) Operation without mains choke Rated mains current 16.8 22.9 Fuse Characteristic gG/gL or gRL Motor connection Max. rated current Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 1-phase mains connection ≥ 30 mA, type B Operating Instructions i550-Cabinet…
-
Page 12: 1-Phase Mains Connection 230/240 V
AC 208 V … 240 V Circuit breaker Characteristic … 2/PE Max. rated current AC 170 V … 264 V Earth-leakage circuit breaker 45 Hz … 65 Hz 1-phase mains connection ≥ 30 mA, type B Motor connection Operating Instructions i550-Cabinet…
-
Page 13: 3-Phase Mains Connection 230/240 V
Operation without mains choke Rated mains current 13.6 20.6 28.8 Fuse Characteristic gG/gL or gRL Max. rated current Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 30 mA, type B ≥ 300 mA, type B Operating Instructions i550-Cabinet…
-
Page 14: 3-Phase Mains Connection 400 V
Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 30 mA, type B ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 22 kW, a mains choke must be used. Operating Instructions i550-Cabinet…
-
Page 15
Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 22 kW, a mains choke must be used. Operating Instructions i550-Cabinet… -
Page 16: 3-Phase Mains Connection 480 V
Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 30 mA, type B ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 30 kW, a mains choke must be used. Operating Instructions i550-Cabinet…
-
Page 17
Circuit breaker Characteristic Max. rated current Earth-leakage circuit breaker 3-phase mains connection ≥ 300 mA, type B In case of Light Duty above 15 kW and Heavy Duty above 30 kW, a mains choke must be used. Operating Instructions i550-Cabinet… -
Page 18: Commissioning
• The analog input X3/AI1 must not be wired or connected to GND. Switch on mains voltage ► Switch on mains voltage and check readiness for operation. Observe LED status displays “RDY” and “ERR” on the inverter front panel. See „LED status“. Operating Instructions i550-Cabinet…
-
Page 19: Functions Of The Keys
3 s. P211.00 7.1.2 Example of the keypad handling Example for DO1 function assignment with parameter P420.02. P430.03 I/O setting GROUP 4 P430.02 P430.02 P210.00 Fct. dig. outputs P420.XX Time DO1 func on P420.02 Operating Instructions i550-Cabinet…
-
Page 20: Extended Terminal Control
A USB module and a standard USB cable (A plug to micro-B plug) is required for this. *P420.02 Release brake GND for analog and digital signals http://www.Lenze.com Relay activated at Relay NO contact *P420.01 Ready for operation Relay common contact Relay NC contact Operating Instructions i550-Cabinet…
-
Page 21: The Most Important Parameters At A Glance
Commissioning The most important parameters at a glance This chapter contains the most important parameters and selections. You can find a detailed description in the commissioning document. http://www.Lenze.com The parameters are divided into the following function groups: • Pxxx.xx group 0: Favorites •…
-
Page 22
V/f characteristic control The control mode is used for speed control of an asynchronous motor via a V/f characteristic with speed feedback. (VFC closed loop) This motor control mode is described in the commissioning manual. http://www.Lenze.com P302.00 V/f characteristic Linear Linear characteristic for drives with constant load torque over the speed. -
Page 23
Reverse rot. dir. Digital input 3 [13] Assignment of a trigger to the “Reverse rotating direction” function. Trigger = TRUE: The setpoint specified is inverted (i.e. the sign is inverted). Trigger = FALSE: No action / deactivate function again. Operating Instructions i550-Cabinet… -
Page 24
• The standard setpoint source for operating mode is selected in P201.01. P440.01 AO1 output area Inhibited Definition of the output range. 0 … 10 V DC 0 … 5 V DC 2 … 10 V DC 4 … 20 mA 0 … 20 mA Operating Instructions i550-Cabinet… -
Page 25
Parameterizable frequency setpoints (preset 2). P450.03 Freq. preset 3 0.0 … 50.0 – 40.0 … 599.0 Hz Parameterizable frequency setpoints (preset 3). P450.04 Freq. preset 4 0.0 … 0.0 … 599.0 Hz Parameterizable frequency setpoints (preset 4). * Default setting dependent on the model Operating Instructions i550-Cabinet… -
Page 26: Group 2: Basic Setting
In progress • When the inverter is switched on, all parameters are automatically loaded from the user memory of the memory module to the RAM Action cancelled memory of the inverter. No access No access (Inverter disabled) Operating Instructions i550-Cabinet…
-
Page 27: Troubleshooting
2. Via P400.04 (default setting of digital input 2). • Cause of error has been eliminated and no blocking time is active. • The error is reset if a signal is applied to digital input 2 (P400.04). Operating Instructions i550-Cabinet…
-
Page 28: Error Codes
• Clean fan and ventilation slots. If required, replace fan. The fans can be unlocked via locking hooks and can then be removed. Error: Motor overtemperature Fault • Check drive sizing. 4310 • Check motor temperature sensor and wiring (X109/T1 and X109/T2). Operating Instructions i550-Cabinet…
-
Page 29
Note: The warning will be reset if the thermal load falls below the warning threshold (P707.08) of — 20 %. Automatic start disabled Fault • Deactivate start command and reset error. FF37 FF85 Keypad full control active Warning • To exit the control mode, press the keypad key. Operating Instructions i550-Cabinet… -
Page 30: Led Status
Fundamental information on project planning and ordering the product Commissioning document Fundamental information for the installation and commissioning of the product Mounting instructions Fundamental information on mounting the product The documents can be found in the Lenze Doc Finder. Operating Instructions i550-Cabinet…
-
Page 31
Further documents Operating Instructions i550-Cabinet… -
Page 32
© 01/2020 | 3.0 Lenze Drives GmbH Postfach 10 13 52, 31763 Hameln Breslauer Straße 3, 32699 Extertal GERMANY HR Lemgo B 6478 Phone: +49 5154 82-0 Fax: +49 5154 82-2800 E-mail: Sales.de@Lenze.com Web: www.Lenze.com Lenze Service GmbH Breslauer Straße 3, 32699 Extertal…
Достоинства
- Интегрированные функции.
- V/f управление (линейное, квадратичное).
- Векторное управление синхронным и асинхронным двигателем (с датчиком обратной связи по скорости и без него).
- Сервоуправление асинхронной машиной.
- Безопасное отключение крутящего момента двигателя.
Экономия средств
- Широкий диапазон входного напряжения и номинальной мощности.
- Поддержка всех сетей автоматизации: CANopen, EtherCAT, EtherNET/IP, Modbus, PROFIBUS, PROFINET.
- Различные конфигурации продукта в зависимости от Ваших индивидуальных требований.
- Компактный размер:
- Книжное исполнение корпуса.
- Глубина 130 мм (до 11кВт) и ширина 60 мм (до 2.2 кВт).
- Возможность установки в один ряд, корпус к корпусу.
- Уменьшение размера шкафа управления.
- Возможность установки в ограниченном пространстве.
Быстрый ввод в эксплуатацию
- Монтаж на панель.
- Зажимные клеммы.
- Готов к работе сразу «из коробки».
- Сменный модуль памяти.
- Настройка с помощью смартфона через WLAN.
Эффективность
- Сокращение потерь электроэнергии благодаря использованию передовых технологий.
- Режим энергосбережения.
- Лучший класс эффективности для инверторов IE2 — EN 50598-2.
Область применения
- Привода насосов, вентиляторов, конвейеров, намотчиков, формовщиков, подъемников.
- Привода систем перемещения и обработки.
Категория товара
частотный преобразователь / регулятор частоты
Применение
Вентиляторы / Конвееры / Насосы / Подъемное оборудование /
Мощность, [кВт]
0.25 / 2.2 / 0.25 / 5.5 / 0.37 / 30 / 37 / 45 / 55 / 75 / 90 / 110 /
Напряжение питающей сети
1-фазное / 3-фазное /
Cетевые возможности
CANopen / EtherCAT / EtherNet/IP / Modbus TCP/IP / POWERLINK / PROFIBUS /
Энерготехсервис
Производство и поставка электрооборудования
+7 (495) 134-15-56
info@et-serv.ru
Заказать звонок
Войти
Главная
Каталог
Преобразователи частоты
Преобразователи частоты LENZE
Преобразователи частоты Lenze серии i550
Фильтры
- «
- 1
- 2
- »
Преобразователи частоты Lenze серии i550
I55AE137F10V10000S Преобразователь частоты (0.37 КВТ, 3ф, 380В)
Мощность (кВт): 0.37
Ток, Iном. (А): 1.30
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE155F10V10000S Преобразователь частоты (0.55 КВТ, 3ф, 380В)
Мощность (кВт): 0.55
Ток, Iном. (А): 1.80
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE175F10V10000S Преобразователь частоты (0.75 КВТ, 3ф, 380В)
Мощность (кВт): 0.75
Ток, Iном. (А): 2.40
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE215F10V10000S Преобразователь частоты (1.5 КВТ, 3ф, 380В)
Мощность (кВт): 1.50
Ток, Iном. (А): 3.90
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE222F10V10000S Преобразователь частоты (2.2 КВТ, 3ф, 380В)
Мощность (кВт): 2.20
Ток, Iном. (А): 5.60
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE230F10V10000S Преобразователь частоты (3 КВТ, 3ф, 380В)
Мощность (кВт): 3.00
Ток, Iном. (А): 7.30
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE240F10V10000S Преобразователь частоты (4 КВТ, 3ф, 380В)
Мощность (кВт): 4.00
Ток, Iном. (А): 9.50
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE255F10V10000S Преобразователь частоты (5.5 КВТ, 3ф, 380В)
Мощность (кВт): 5.50
Ток, Iном. (А): 13.00
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE275F10V10000S Преобразователь частоты (7.5 КВТ, 3ф, 380В)
Мощность (кВт): 7.50
Ток, Iном. (А): 16.50
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE311F10V10000S Преобразователь частоты (11 КВТ, 3ф, 380В)
Мощность (кВт): 11.00
Ток, Iном. (А): 23.50
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE315F10V10000S Преобразователь частоты (15 КВТ, 3ф, 380В)
Мощность (кВт): 15.00
Ток, Iном. (А): 32.00
Напряжение, В: 380.00
Преобразователи частоты Lenze серии i550
I55AE318F10V10000S Преобразователь частоты (18.5 КВТ, 3ф, 380В)
Мощность (кВт): 18.50
Ток, Iном. (А): 40.00
Напряжение, В: 380.00
- «
- 1
- 2
- »
Наши эксперты помогут Вам подобрать нужное оборудование и составят индивидуальную смету
Заполните форму, и специалист свяжется с вами в ближайшее время
Имя *
Телефон *
Email *
Сообщение *
Отправляя данные через эту форму, Вы выражаете согласие
на обработку персональных данных
Преобразователи частоты
Преобразователи частоты DeltaПреобразователи частоты VEDA DRIVE (DANFOSS)Преобразователи частоты ВЕСПЕРПреобразователи частоты РусэлкомПреобразователи частоты OptimusDriveПреобразователи частоты SAJЧастотный преобразователь DanfossПреобразователи частоты VaconПреобразователи частоты TOSHIBAПреобразователи частоты LENZEПреобразователи частоты HyundaiПреобразователи частоты Advanced ControlПреобразователи частоты ESQПреобразователи частоты Триол
Электрощитовое оборудование
Вводно-распределительные устройства ВРУ, УВРЩиты распределительные ЩРШкаф автоматического ввода резерва, АВРГлавный распределительный щит, ГРЩУстройства этажные распределительные многоящичные, УЭРМЩит автоматического переключения, ЩАПЩитки освещения для производственных и общественных зданий ЩОПанели распределительных щитов серий ЩО70, ЩО90Щиты этажные, ЩЭ
Устройства плавного пуска
Устройства плавного пуска DanfossУстройства плавного пуска AUCOM
Сервопривод
Сервопривод Delta
Шкафы управления насосами и вентиляторами
Шкафы управления насосами ЦТП, ИТП, ВНС, котельныхШкафы управления насосами КНСШкафы управления дымососами и вентиляторамиШкафы управления погружными насосами
Контроллеры
Контроллеры DeltaАксессуарыПанели оператора
Станции и щиты управления СУ-ЧЭ, СУ-ПП, ЩУ-ЧЭ
Станции управления частотно-регулируемым приводом (СУ-ЧЭ)Станции управления устройством плавного пуска (СУ-ПП)Щиты управления частотным электроприводом (ЩУ — ЧЭ)
Фильтры
Цена
Производитель
Lenze 18
Напряжение, В
380 18
Мощность, кВт
Ток, А
Преобразователь частоты (инвертор) i550 motec для использования в диапазоне мощности 0.37…5.5 кВт (запланировано расширение до 45 кВт), устанавливаемый на двигатель или стену и обеспечивающий степень защиты IP66, служит для создания децентрализованной приводной системы.
Основные особенности этого инвертора — быстрый монтаж и простой ввод в эксплуатацию благодаря использованию удобных инструментов, а также возможности подключения с помощью стандартных разъемов. Параметры, характеристики привода и удобство использования полностью соответствуют нашим преобразователям частоты, которые хорошо зарекомендовали себя в эксплуатации. В дополнение к высокой энергоэффективности мы предлагаем современное устойчивое решение для создания приводной системы.
Требования Рекомендации по экологическому проектированию выполнены полностью.
Области применения: приводы конвейера, ходовые приводы, приводы намоточного устройства, подъемные приводы, экструдеры, упаковочные машины, насосы, вентиляторы и т.д.
Достоинства
- Компактное решение для децентрализованной приводной системы, настенный монтаж или установка на двигатель
- Высокая степень защиты IP66 для универсального применения даже в самых тяжелых условиях эксплуатации
- Быстрый монтаж благодаря стандартизированным разъемным соединениям (plug & play)
- Поддержка функциональности ведущего устройства IO-Link для простого обмена данными между датчиками и исполнительными механизмами IO-Link
- Встроенный режим регенеративной обратной связи для очень высокой энергоэффективности — тормозной резистор больше не требуется
Технические данные и особенности
Технические данные |
0.37 … 45 кВт |
---|---|
Возможности подключения |
3 фазы 230 В пер. тока |
Связь |
EtherCAT |
Lenze i550 Inverter PDF User Guides and Manuals for Free Download: Found (17) Manuals for Lenze i550 Device Model (Software Manual, Mounting And Switch-on Instructions)
More DC Drives Device Models:
-
Parker
Compax3S025V2
Electromechanical AutomationProduct Management & Application11.02.2008Klaus ZimmerParker Hannifin GmbH & Co KGEME — Electromechanical Automation EuropePostfach 17 20 * 77607 OffenburgRobert-Bosch-Straße 22 * 77656 OffenburgE-Mail: [email protected] I20 T11 ControlManager application note eng.docSeite …
Compax3S025V2 Servo Drives, 20
-
Kieback&Peter
DS230
Kieback&Peter GmbH & Co. KGTempelhofer Weg 50, 12347 Berlin/GermanyTelefon: +49 30 60095-0, Telefax: +49 30 60095-164www.kieback-peter.de, [email protected] 3.50-32.020-01-ENDS230/4..32 Actuating DrivesIssue 2009-03-15AÄnderungen vorbehalten — Contents subject to change — Sous réserve de modific …
DS230 DC Drives, 10
-
Siemens
COMBIMASTER 411
1 Getting Started Guide – March 2002 A5E00157510A COMBIMASTER 411 & MICROMASTER 411 English This Getting Started Guide allows for easy and efficient commissioning of the Siemens COMBIMASTER 411 and MICROMASTER 411 Inverters. For further technical information, please refer to the Operating Instructions an …
COMBIMASTER 411 Inverter, 20
-
ABB
ACH550-UH HVAC
ACH550Installation, Operation and Maintenance Manual (I, O & M)ACH550-UH HVAC Drives (1…550 HP)ACH550-BCR/BDR/VCR/VDR E-Clipse Bypass Drives (1…400 HP)ACH550-PCR/PDR Packaged Drives with Disconnect (1…550 HP) …
ACH550-UH HVAC Controller, 94
Recommended Documentation: