Bookmarks
Quick Links
Description and operating instructions
Industrial Ethernet Rail Switch 2
Hirschmann. Simply a good Connection.
RS2-TX
1
2
P
FAULT
1
3
5
7
DA/STAT
2
4
6
8
0 1
LA1
LA2
LA3
LA4
LA5
LA6
LA7
LA8
1
2
3
4
5
6
7
8
RS2-TX
Order No.
943 686-003
The Rail Switch RS2 has been especially
designed for use in industrial environments.
It supports ETHERNET 10 MBit/s and Fast
ETHERNET 100 MBit/s.
The Rail Switch modules support switched
ETHERNET networks in accordance with
IEEE standard 802.3 using copper technolo-
gy. The switch modules are plugged onto
the standard bar.
The RS2-TX modules have eight 10/100
MBit/s twisted pair ports (RJ45 connectors).
It is possible to connect up to eight data ter-
minal equipments or other network seg-
ments to the 10/100 Mbit/s ports using twi-
sted pair cabling. The ports support auto
negotiation, autopolarity and autocrossing.
Summary of Contents for Belden Hirschmann RS2-TX
File Specifications:1483/1483350-hirschmann_rs2tx.pdf file (25 Mar 2023) |
Accompanying Data:
Belden Hirschmann RS2-TX Network Router PDF Description And Operating Instructions (Updated: Saturday 25th of March 2023 02:47:37 AM)
Rating: 4.2 (rated by 22 users)
Compatible devices: HIRSCHMANN BRS20, 200EW/E, HIRSCHMANN RS2-xTX/xFX EEC Series, Hirschman RSPS20, 1821n Wireless, GarrettCom Magnum DX940e, HIRSCHMANN RSR20 Series, HIRSCHMANN EAGLE40-03.
Recommended Documentation:
Manual, Description And Operating Instructions (Text Version):
(Ocr-Read Summary of Contents of some pages of the Belden Hirschmann RS2-TX Document (Main Content), UPD: 25 March 2023)
-
1, Description and operating instructions Industrial Ethernet Rail Switch 2 RS2-TX Order No. 943 686-003 The Rail Switch RS2 has been especially designed for use in industrial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s. The Rail Switch modules support switched ETHERNET networks in accordance with IEEE standard 802.3 using copper technolo- gy. The switch modules are plugged onto…
-
2, Belden Hirschmann RS2-TX 2 The performance features described here are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi- ble to rule out deviations completely, so we are unable to guarantee complete agree- ment. However, the details in the technical publication are checked regularly. Any cor- recti…
-
3, Belden Hirschmann RS2-TX 3 CONTROL DRAWING for Industrial ETHERNET Rail Switch 2 and Rail Transceiver 2 Family According to ANSI / ISA 12.12.01-2012 Rev.: 0 Date: 2012-07-13 Document No.: 000163806DNR Page 1 of 1 NON HAZARDOUS LOCATION Power Supply: (Redundant: P1, P2) 24 V DC Relay Contacts: Associated Apparatus: Equipment with nonincendive fi eld wiring 1 HAZARDOUS LOCATION Class I, Division 2 Groups A, B, C, D The Use in Hazardous Locations is only allowed for Rail Switch 2 …
-
4, 4 Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions. Correct transport, storage, and assembly as well as careful operati- on and maintenance are essential in ensuring safe and reliable operation of this device. Use only undamaged parts! 䡺 …
-
5, 5 1. Functional description The 10/100BASE-T(X) ports of an RS2-TX represent a terminal connection for the connected LAN segment. You can connect single devices or complete network seg- ments. 1.1 FRAME SWITCHING FUNCTIONS Store and Forward All data received by the RS2-TX from the system bus or at the ports are stored and checked for validity. Invalid and defective frames (> 1.522 byte or CRC error) as well as fragments (< 64…
-
6, 6 3.3 STARTUP PROCEDURE 䡺 You start up the RS2-TX by connecting the supply voltage via the 5-pin terminal block. 3.4 DISMANTLING 䡺 To take the RS2-TX off the ISO/DIN rail, insert a screwdriver horizontally under the housing into the locking slide, pull it (with- out tipping the screwdriver) downwards and lift the RS2-TX upwards. 4. Further support In the event of technical queries, please talk to the Hirschmann contract part…
-
7, 7 5. Technical data General data Operating voltage NEC Class 2 power source 24 V DC (-25% +33%) safety extra-low voltage (SELV) (redundant inputs decoupled), 5 A maximum Buffer time min. 10 ms at 24 VDC Potential difference between input Potential difference to input voltage, +24 VDC: 32 V DC voltage and housing Potential difference to input voltage, ground: -32 V DC Current consumption at 24 VDC 7.0 W maximum; 24 Btu (IT)/h Overload current protection at input non-changeable …
-
8, Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 72654 Neckartenzlingen Germany Tel.: +49 (0)1805 14-1538 Fax: +49 (0)7127 14-1551 E-mail: [email protected] Internet: http://www.hirschmann.com 039 663-001-08-0415
…
-
Belden Hirschmann RS2-TX User Manual
-
Belden Hirschmann RS2-TX User Guide
-
Belden Hirschmann RS2-TX PDF Manual
-
Belden Hirschmann RS2-TX Owner’s Manuals
Recommended: UA-11, FRS237, 48UP910, MG323, Instant Press
Links & Tools
Operating Impressions, Questions and Answers:
Specifications:
|
Accompanying Data:
Belden Hirschmann RS2-TX Network Router PDF Description And Operating Instructions (Updated: Saturday 1st of April 2023 08:38:11 AM)
Rating: 4.4 (rated by 55 users)
Compatible devices: HIRSCHMANN RS2-xTX/xFX EEC Series, HIRSCHMANN RSR20 Series, 400 Family, Hirschman RSPS20, Hirschmann OWL LTE M12, GarrettCom Magnum DX940e, HIRSCHMANN EAGLE40-03, S5500-EI series.
Recommended Documentation:
Belden Hirschmann RS2-TX: Text of Manual, Description And Operating Instructions
(Ocr-Read Version Summary of Contents, UPD: 01 April 2023)
-
1, Description and operating instructions Industrial Ethernet Rail Switch 2 RS2-TX Order No. 943 686-003 The Rail Switch RS2 has been especially designed for use in industrial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s. The Rail Switch modules support switched ETHERNET networks in accordance with IEEE standard 802.3 using copper technolo- gy. …
-
2, 2 The performance features described here are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi- ble to rule out deviations completely, so we are unable to guarantee complete agree- ment. However, the details in the technical publicatio…
-
3, 3 CONTROL DRAWING for Industrial ETHERNET Rail Switch 2 and Rail Transceiver 2 Family According to ANSI / ISA 12.12.01-2012 Rev.: 0 Date: 2012-07-13 Document No.: 000163806DNR Page 1 of 1 NON HAZARDOUS LOCATION Power Supply: (Redundant: P1, P2) 24 V DC Relay Contacts: Associated Apparatus: Equipment with nonincendive fi eld wiring 1 HAZARDOUS LOCATION Class…
-
4, 4 Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions. Correct transport, storage, and assembly as well as careful operati- on and maintenance are essential in ensuring safe and reliable operation of this device. Us…
-
5, 5 1. Functional description The 10/100BASE-T(X) ports of an RS2-TX represent a terminal connection for the connected LAN segment. You can connect single devices or complete network seg- ments. 1.1 FRAME SWITCHING FUNCTIONS Store and Forward All data received by the RS2-TX from the system bus or at the ports are stored and checked for validity. Invalid and defective frames (…
-
6, 6 3.3 STARTUP PROCEDURE 䡺 You start up the RS2-TX by connecting the supply voltage via the 5-pin terminal block. 3.4 DISMANTLING 䡺 To take the RS2-TX off the ISO/DIN rail, insert a screwdriver horizontally under the housing into the locking slide, pull it (with- out tipping the screwdriver) downwards and lift the RS2-TX upwards. 4. Further support In the event o…
-
7, 7 5. Technical data General data Operating voltage NEC Class 2 power source 24 V DC (-25% +33%) safety extra-low voltage (SELV) (redundant inputs decoupled), 5 A maximum Buffer time min. 10 ms at 24 VDC Potential difference between input Potential difference to input voltage, +24 VDC: 32 V DC voltage and housing Potential difference to input voltage, ground: -32 V DC Current consumption at 2…
-
8, Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 72654 Neckartenzlingen Germany Tel.: +49 (0)1805 14-1538 Fax: +49 (0)7127 14-1551 E-mail: [email protected] Internet: http://www.hirschmann.com 039 663-001-08-0415
…
Belden Hirschmann RS2-TX: Recommended Instructions
JUICEMAX, WEBCOACH EASYVIEW, NS-13T001, 1-1024UF, Compaq TC1 100
-
43Cisco Systems, Inc. www.cisco.comConnecting the Router to PowerThis section describes how to connect the Cisco 1120 Connected Grid Router to AC and DC power sourceThese topics are discussed: Before You Begin, page 43 AC Power Connection Information, page 45 Connect to AC Power, page 49 Connect to DC Power, page 50 Power Cycling the Router, page 51Before You Be …
1120 10
-
Moxa EtherDevice™ Switch EDS-600 Series Hardware Installation Guide First Edition, August 2009 © 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan, R.O.C. TEL: +886-2-8919-1230 P/N: 1802006000010 …
EDS-600 Series 20
-
TRENDnet’s TEM100-56R PC Card with XpressPort is the perfect solution for LAN/WAN applications. The 16-bit PC Card adapter combines both 10/100Mbps dual speed Fast Ethernet and the optimal power of V.90/K56Flex dual mode 56K fax/modem capabilities. The TEM100-56R makes it simple to combine numerous communication jobs at the same time. The TEM100-56R lets you dial into any on-line service and …
TEM100-56R 2
-
QFX10002See the complete QFX Series documentation at http://www.juniper.net/techpubs/.To install and configure any model of the Juniper Networks QFX10002 switch, you need:z Either an electric lift or two people to lift the switch into place. An additional person is needed for securing the switch to the rack.z Electrostatic discharge (ESD) grounding strap (not provided).z …
QFX10002 2
-
Quick Start Cisco IP Phone 8800 Series1 Place a Call2 Answer a Call3 Hold4 Transfer5 Conference6 Mute Audio7 Forward All8 Voicemail9 Divert10 Call History11 Directories12 Settings13 Phone Buttons and Hardware14 USB Charging15 Intelligent Proximity16 Tips17 For More InformationNote For best results, print on 8.5inch x 14inch (legal-sized) paper.1 Place a CallTo place a call, pick up …
8800 2
-
Matrix Switch CorporationMSC-1HD1608LProduct Manual1RU 16 input 8 output 3G-SDI Video Router with Button Control PanelRevision 1.7Page 1 of 60 © 2013-2018 Matrix Switch Corporation www.matrixswitchcorp.com …
MSC-1HD1608L 60
-
Mission-Critical Connectivity for VehiclesCOR IBR1700 SeriesPower / GPIO Cable Spare SIM / Modem Door ScrewsWHAT’S INCLUDED: + Cloud-managed + 3 WiFi Radios + Ignition sensing + 9-33 DC voltage input range + Active GPS support + SIM-based auto-carrier selection + Fully ruggedized + Metal housing + Dual-SIM + Integrated 600Mbps LTE/HSPA+ modem + MC400 slot for 2nd modem + …
COR IBR1700 Series 2
-
You’ll be entered into a quarterly drawing for free Cisco Press books by returning this survey! Cisco is dedicated to customer satisfaction and would like to hear your thoughts on these printed manuals. Please visit the Cisco Product Comments on-line survey at www.cisco.com/go/crc to submit your comments about accessing Cisco technical manuals. Thank you for your time.General Information1 …
XR 12404 292
-
Quick start NL | EN | DE6000-0083-01 Adam HAModel 159- 01 [email protected] B.V. Wattstraat 56, 2171 TR SassenheimNLInstallatie » Softwareconguratie zonever-warming, via de webpagina van Adam. » Aansluiten op de warmtebron. » Verbind Adam met het internet. » Controleer de instellingen en vul een postcode in voor de weersvoorspelling.EU-con …
Adam HA 2
-
Operation Manual – SNMP H3C S9500 Series Routing Switches Table of Contents i Table of Contents Chapter 1 SNMP Configuration……………………………………………………………………………………….1-1 1.1 SNMP Overview………………………………………………………………………………………………….. 1- …
S9500 Series 14
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
1. Functional description
The 10/100BASE-T(X) ports of an RS2-TX
represent a terminal connection for the
connected LAN segment. You can connect
single devices or complete network seg-
ments.
1.1 FRAME SWITCHING FUNCTIONS
Store and Forward
All data received by the RS2-TX from the
system bus or at the ports are stored and
checked for validity. Invalid and defective
frames (> 1.522 byte or CRC error) as well
as fragments (< 64 byte) are discarded. The
RS2-TX forwards the valid frames.
Multi address capability
An RS2-TX learns all source addresses per
port. Only packets with
– unknown addresses
– addresses learnt at this port
– a multi/broadcast address
in the destination address field are sent to
this port.
An RS2-TX learns up to 1,000 addresses.
This becomes necessary if more than one
terminal device is connected to one or more
ports. In this way several independent sub-
networks can be connected to an RS2-TX.
Learnt addresses
An RS2-TX monitors the age of the learned
addresses. The RS2-TX deletes address
entries from the address table which exceed
a certain age (300 seconds).
Note: Restarting deletes the learned
address entries.
Tagging (IEEE 802.1Q)
The IEEE 802.1 Q standard designates the
VLAN tag to be included in a MAC data
frame for the VLAN and prioritizing func-
tions. The VLAN tag consists of 4 bytes (2
bytes tag protocol identifier TPID, 2 bytes
tag control information TCI). It is inserted
between the source address field and the
type field. Data packets with VLAN tag are
transmitted unchanged by the RS2-TX.
1.2 SPECIFIC FUNCTIONS OF THE
TP/TX INTERFACE
Link control
The RS2-TX monitors the connected TP/TX
line segments for short-circuit or interrupt
using regular link test pulses in accordance
with IEEE standard 802.3 10/100BASE-T/TX.
The RS2-TX does not transmit any data to a
TP/TX segment from which it does not
receive a link test pulse.
Note: A non-occupied interface is assessed
as a line interrupt. The TP/TX line to termi-
nal equipment which is switched off is like-
wise assessed as a line interrupt as the de-
energised bus coupler cannot transmit link
test pulses.
Auto polarity exchange
If the receive line pair is incorrectly connec-
ted (RD+ and RD- switched) polarity is auto-
matically reversed.
Autocrossing
The RS2-TX detects the transmit and re-
ceive pairs (MDI, MDI-X). The RS2-TX auto-
matically configures its port for the correct
transmit and receive pins. Consequently it
does not matter whether you connect devi-
ces using a cross-over or straight cable.
1.3 FURTHER FUNCTIONS
AND FEATURES
Reset
The RS2-TX will be reset by the following
action:
– input voltages fall below a threshold
After a reset the following action is carried
through:
– initialization
1.4 DISPLAY ELEMENTS
Equipment status
These LEDs provide information about sta-
tuses which affect the function of the entire
RS2-TX.
P1 – Power 1 (green LED)
– lit:
– supply voltage 1 present
– not lit: – supply voltage 1 less than 9.6 V
P2 – Power 2 (green LED)
– lit:
– supply voltage 2 present
– not lit: – supply voltage 2 less than 9.6 V
FAULT – Failure (red LED)
– lit:
– The indicator contact is
open, i.e. it indicates an
error.
– not lit:
– The indicator contact is
closed, i.e. it does not
indicate an error.
Port Status
These LEDs display port-related informati-
on.
DA/STAT 1 to 8 – Data, Link status
(green/yellow LED)
– not lit:
– no valid link
– lit green:
– valid link
– flashes yellow:– receiving data
1.5 CONTROLS
8-pin DIP switch
Using the 8-pin DIP switch on the RS2-TX
front panel
– the message about the link statuses can
be suppressed by the indicator contact on
a port-by-port basis. Using switches LA1
to LA8, the message about the link status
of ports 1 to 8 is suppressed. State on
delivery: switch position 1 (on), i.e. messa-
ge not suppressed.
0
1
LA1
Port 1
LA2
Port 2
LA3
Port 3
Suppress message
LA4
Port 4
about link status
LA5
Port 5
via indicator contact
LA6
Port 6
LA7
Port 7
LA8
Port 8
Fig. 2: 8-pin DIP switch on RS2-TX
1.6 INTERFACES
10/100 MBit/s connection
Eight 10/100 Mbit Ports (ports 1 to port 8, 8-
pin R45 sockets) on RS2-TX allow terminal
equipment or eight independent network
segments complying with the standards
IEEE 802.3 100BASE-TX / 10BASE-T to be
connected. These ports support autonego-
tiation and the autopolarity function.
The socket casings are electrically connec-
ted to the front panel of the RS2-TX.The pin
configuration complies with MDI-X.
– Pin configuration of the RJ45 socket:
– 1 line pair: pin 3 and pin 6
– 1 line pair: pin 1 and pin 2
– remaining pins: not used.
n.c.
Pin 8
n.c.
Pin 7
TD-
Pin 6
n.c.
Pin 5
n.c.
Pin 4
TD+
Pin 3
RD-
Pin 2
RD+
Pin 1
Fig. 3: Pin configuration of an TP/TX
interface
5pin terminal block
The supply voltage and the indicator
contact are connected via a 5pin terminal
block.
z
Warning!
The RS2-TX equipment is designed
for operation with a safety extra-low
voltage. Thus, they may only be
connected to the supply voltage
connections with SELV circuits with
the voltage restrictions in accordan-
ce with IEC/EN 60950-1.
– Voltage supply: Redundant voltage sup-
plies are supported. Both inputs are
decoupled. There is no load distribution.
With redundant supply, the power pack
supplies the RS2-TX only with the higher
output voltage. The supply voltage is elec-
trically isolated from the housing.
– Indicator contact:
The indicator contact is used to supervise
the functions of the RS2-TX and thus faci-
litates remote diagnosis without manage-
ment software.
Contact interrupt indicates the following
by means of a potential-free indicator
contact (relay contact, closed circuit):
– the failure of at least one of the two
supply voltages.
– a permanent fault in the RS2-TX (inter-
nal 3,3 V DC voltage, supply voltage 1 or
2 < 9.6 V, …).
– the faulty link status of at least one port.
The indication of the link state on the
RS2-TX can be masked on a port-by-port
basis using the DIP switches LA1 to LA8.
State of delivery: there is no link test.
Note: In the case of the voltage supply
being routed without redundancy, the RS2-
TX indicates the failure of a supply voltage.
You can prevent this message by feeding in
the supply voltage through both inputs.
= 0V
Fig. 5: Pin configuration of 5pin terminal
block
Ground connection
The RS2-TX is grounded via a separate
screw connection.
5
-
Redback Networks SmartEdge 400
Mounting the Chassis4-8 SmartEdge 400 Router Hardware GuideInstall the Cable Management BracketsThe SmartEdge 400 router is shipped with a pair of cable management brackets; the bracket for the front of the chassis is approximately 1.0 in (2.54 cm) longer than the bracket for the rear of the chassis. When installed at …
SmartEdge 400 Network Router, 28
-
Linksys WAP54G — Wireless-G Access Point
A Division of Cisco Systems, Inc.®Model No.Model No.WirelessQuick Installation GuideWireless1Model No.Quick Installation GuideWAP54G (EU/LA/UK)Access PointWireless-GPackage Contents• Wireless-G Access Point• Detachable Antennas• Power Adapter• Setup CD with User Guide• Ethernet Network Cable• Quick Install …
WAP54G — Wireless-G Access Point Wireless Access Point, 293
-
Zte ZXHN H108L
ZXHN H108L Wireless ADSL Router Maintenance Manual Version 1.0 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected] …
ZXHN H108L Network Router, 89
-
Teltonika RUT104 HSUPA
4 STEP 6. Configure wireless network settings It is recommended to use WPA-PSK- TKIP or WPA-PSK- AES data encryption. The passphrase for data encryption must be 8-63 characters long. Passphrase can include symbols (!?*&) and spaces. This passphrase must be the same as Network key in the PC wireless network secur …
RUT104 HSUPA Network Router, 2
-
Makita 3621
INSTRUCTION MANUALMANUEL D’INSTRUCTIONMANUAL DE INSTRUCCIONESWARNING:For your personal safety, READ and UNDERSTAND before using.SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.AVERTISSEMENT:Pour votre propre sécurité, prière de lire attentivement avant l’utilisation.GARDER CES INSTRUCTIONS POUR RÉFÉRENCE ULTÉ …
3621 Network Router, 24
-
NetComm NL1901ACV
Restore Factory Defaults Settings Guide NL1901ACV NL1901ACV – Restore Factory Defaults Settings Guide 1 of 4 FQ01131 v. 1.1 March 2019 © NetComm Wireless 2019 About Factory Resets A factory reset on the NL1901ACV returns all settings to the default settings as it was when shipped from the factory. Important …
NL1901ACV Network Router, 4
-
HP NAS 1200s
Addendum© Copyright 2004 Hewlett-Packard Development Company, L.P. 367499-001Printed in the U.S.A. March 2004Product names mentioned herein may be trademarks of their respective companies as reflectedby an associated footnote. The information in this document is subject to change without notice.This addendum applies …
NAS 1200s Storage, 7
-
H3C S3610 Series
Operation Manual – SSL-HTTPS H3C S3610&S5510 Series Ethernet Switches Table of Contents i Table of Contents Chapter 1 SSL Configuration …………………………………………………………………………………………. 1-1 1.1 SSL Overview ……………………………………………. …
S3610 Series Switch, 15
Hirschmann Automation and Control GmbH
www.beldensolutions.com
05-08-2014
Page 1 of 2
Product information
RS2-3TX/2FX EEC
Industrial Ethernet:Unmanaged Industrial Ethernet Switches:RS2-Switches:RS2-3TX/2FX EEC
Name
RS2-3TX/2FX EEC
Unmanaged Industrial ETHERNET Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Delivery informations
Availability
available
Product description
Description
Unmanaged Industrial ETHERNET Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity
3 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100BASE-FX, MM cables, SC sockets
Type
RS2-3TX/2FX EEC
Order No.
943 771-001
More Interfaces
Power supply/signaling contact
1 plug-in terminal block, 5-pin
Network size — length of cable
Twisted pair (TP)
0 — 100 m
Multimode fiber (MM) 50/125 µm
0 — 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm
0 — 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Network size — cascadibility
Line — / star topology
any
Power requirements
Operating voltage
24 V DC (-25% to +30%)
Current consumption at 24 V DC
max. 230 mA
Power consumption
max. 5,9 at 24 V DC
Service
Diagnostics
LEDs (power, link status, data, error), signal contact / fault relais (24 V DC / 1 A)
Redundancy
Redundancy functions
redundant 24 V power supply
Ambient conditions
Operating temperature
-40 ºC to +70 ºC
Storage/transport temperature
-40 ºC to +85 ºC
Relative humidity (non-condensing)
10% to 95%
MTBF
43.4 years; MIL-HDBK 217F: Gb 25 ºC
Mechanical construction
Dimensions (W x H x D)
47 mm x 135 mm x 111 mm
Mounting
DIN Rail 35 mm
Weight
320 g
Protection class
IP 20
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
1 mm, 2 Hz — 13.2 Hz, 90 min.; 0.7g, 13.2 Hz — 100 Hz, 90 min.; 3.5 mm, 3 Hz — 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz — 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 — 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity
3 V (10 kHz — 150 kHz), 10 V (150 kHz — 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC CFR47 Part 15 Class A