Grundfos cue руководство

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

GRUNDFOS PRODUCT GUIDE

Grundfos CUE

Frequency converters for pump control

60 Hz

loading

Related Manuals for Grundfos CUE Series

Summary of Contents for Grundfos CUE Series

  • Page 1
    GRUNDFOS PRODUCT GUIDE Grundfos CUE Frequency converters for pump control 60 Hz…
  • Page 2: Table Of Contents

    Operating range …………24 IP21/NEMA1 kit …………55 Motor bearing monitoring ……….24 Output filters …………..56 Standstill heating …………24 Grundfos differential pressure sensor, DPI ….59 Ramps …………….25 Proportional differential pressure, parabolic ….25 Hmax update …………..26 Further product documentation Differential pressure from two sensors ……26 Start delay after power-up……….26…

  • Page 3
    Mission Grundfos CUE — to successfully develop, produce and sell high-quality pumps and pumping systems worldwide, contributing to a better quality of life and a healthy environment Bjerringbro, Denmark Fresno, California Olathe, Kansas Monterrey, Mexico Allentown, Pennsylvania Oakville, Ontario • One of the 3 largest pump companies in the world •…
  • Page 4: Introduction

    Fig. 1 Grundfos CUE solution Built-in E-pump functionality The CUE solution contains the same control functionality as the Grundfos E-pumps and is thus a supplement to the E-pump range. See the table below. All CUE Solutions are available in two enclosure classes: IP21 (NEMA 1) or IP55 (Nema 12).

  • Page 5
    The CUE can be used in both new and existing instal- lations, but the pump and motor should be suitable for use with frequency converters. The table below shows which Grundfos pump types the CUE is designed for. Pump type…
  • Page 6: Features And Benefits

    The duty/standby function is used to alternate between known system from Grundfos E-pumps. two pumps. Each pump is connected to a CUE unit. The • Remote operation via external signals, for instance primary task is to start the standby pump if the duty via digital inputs or GENIbus.

  • Page 7: Accessories

    Features and benefits Grundfos CUE Accessories Grundfos offers a number of accessories for the CUE. MCB 114 sensor input module The MCB 114 is an option offering additional analog inputs for the CUE: • 1 analog input, 4-20 mA • 2 inputs for Pt100/Pt1000 temperature sensors.

  • Page 8: Applications

    Applications Grundfos CUE Overview applications The CUE is a multi-purpose frequency converter suita- ble for a variety of applications demanding reliable and cost-efficient pump operation. The CUE is used in five main fields of application: Water supply and pressure boosting…

  • Page 9: Identification

    Identification Grundfos CUE Nameplate The CUE can be identified by means of the nameplate. An example is shown below. Fig. 2 Example of nameplate Text Description CUE (product name) T/C: 202P132… (internal code) Prod.no: Product number: 96754515* Serial number: 123456G123…

  • Page 10: Product Range

    Product range Grundfos CUE Overview The CUE cabinet sizes are characterised by their enclosures. The table shows the relation between power size (P2), mains supply (V) and enclosure class (IP). It shows the complete range of the CUE. Mains supply and enclosure class…

  • Page 11: Functions

    Functions Grundfos CUE Overview The table below shows the functions settings offered by the CUE. Setting or reading via: CUE functions GENIbus PC Tool* Operating modes, see page 13 Normal Stop Min. Max. Control modes, see page 14 Open loop…

  • Page 12
    Functions Grundfos CUE Setting or reading via: CUE functions GENIbus PC Tool* Digital inputs, see page 27 Start/stop Min. (Min. curve) Max. (Max. curve) External fault Flow switch Alarm reset Dry running (from external sensor) Accumulated flow (from pulse flow sensor)
  • Page 13: Operating Modes

    Functions Grundfos CUE Operating modes These operating modes can be selected with the CUE: • Normal • Stop • Min. • Max. The operating modes can be set without changing the setpoint setting. Normal The pump operates in the control mode selected. See page 14.

  • Page 14: Control Modes

    Functions Grundfos CUE Control modes The CUE has a built-in PID controller that provides closed-loop control of the value you want to control. The CUE can also be set to open-loop control where the setpoint represents the desired pump speed.

  • Page 15
    Functions Grundfos CUE Open loop, constant curve Constant differential pressure, pump The speed is kept at a set value in the range between The differential pressure of the pump is kept constant, the min. and max. curves. See fig. 4.
  • Page 16
    Functions Grundfos CUE Constant pressure with stop function Constant level with stop function The outlet pressure is kept constant at high flow rate. The liquid level is kept constant at high flow rate. On/off On/off operation at low flow rate. See fig. 8.
  • Page 17: Setpoints

    Functions Grundfos CUE Constant temperature In control mode Open loop, the setpoint is set in% cor- responding to the required speed. The setting range is The liquid temperature is kept constant, independently between the min. and max. curves. of the flow rate. See fig. 12.

  • Page 18
    Functions Grundfos CUE External setpoint influence (default) Inverse external setpoint The actual setpoint is a linear function of the external The actual setpoint is an inverse linear function of the setpoint signal. See fig. 15. external setpoint signal. See fig. 17.
  • Page 19
    Functions Grundfos CUE External setpoint with stop function The linear function is defined as an interpolation between the points in a table. The table has of up to 8 Setting via PC Tool. points. The actual setpoint with stop is a linear function of the…
  • Page 20: Setting The Direction Of Rotation

    Functions Grundfos CUE Setting the direction of rotation Operating hours The value of operating hours is an accumulated value The start-up guide begins the first time the CUE is con- calculated from the pump’s birth and cannot be reset. nected to supply voltage. While going through the start- No additional sensor is required.

  • Page 21: Pid Controller

    Functions Grundfos CUE PID controller Suggested controller settings The CUE has a built-in PID controller for speed control System/application Heating Cooling of pumps. The factory setting of gain (K ) and integral system system time (T ) can easily be changed in the control panel.

  • Page 22: Stop Functions

    Functions Grundfos CUE Stop functions Note: The non-return valve must always be installed before the pressure sensor. See figs 23 and 24. Constant pressure with stop function The purpose of the stop function is to stop the pump Diaphragm tank when low or no flow is detected.

  • Page 23: Dry-Running Protection

    The two pumps use their own local operating mode. For instance, pump 1 can operate in Normal mode, and pump 2 can operate in Max. mode. ® • a Grundfos Liqtec dry-running switch • a pressure switch installed on the suction side of the Control mode pump Both pumps must have the same control mode.

  • Page 24: Operating Range

    Functions Grundfos CUE Operating range Extended function The bearing temperature is also included in the calcu- The area between the min. and max. speed is the lation. actual operating range of the pump. The extended function requires an MCB 114 sensor…

  • Page 25: Ramps

    Functions Grundfos CUE Ramps Proportional differential pressure, parabolic The controller incorporates two types of ramp: Setting via PC Tool. • ramp-up and ramp-down (default) • initial and final ramps (setting via PC-Tool). The proportional differential pressure can be selected with one of these flow dependencies: Speed •…

  • Page 26: Hmax Update

    Functions Grundfos CUE Hmax update Sensor 2 is connected to the sensor input 2 of an MCB 114 sensor input module. Setting via PC Tool. Start delay after power-up This function is used in connection with the control mode Proportional differential pressure. The purpose is Setting via PC Tool.

  • Page 27: Limit Exceeded

    Functions Grundfos CUE Limit exceeded Digital inputs Setting via PC Tool. As standard, the CUE offers these digital inputs: This is a monitoring function offering information, warn- • one digital input for external start/stop ing or alarm when a low or high limit is exceeded. See •…

  • Page 28: Signal Relays

    Functions Grundfos CUE Predefined ramps (setting via PC Tool) Analog inputs The ramp-up and ramp-down time can be remote-set As standard, the CUE offers these analog inputs: from the default setting to a predefined setting by • one analog input for external setpoint means of PC Tool.

  • Page 29: Mcb 114 Sensor Input Module

    The MCB 114 sensor input module offers three addi- RS-485 port must be selected to GENIbus, and the tional analog inputs for the CUE: communication must be set according to the Grundfos • one analog 4-20 mA input for an additional sensor GENIbus standard.

  • Page 30: Copy Of Setting

    • Make a copy of the setup from the present CUE to the Grundfos Local Control Panel • Make a copy of the setup stored in the Grundfos Lo- cal Control Panel to the CUE Both functions must be used in the correct order to copy a setup from one CUE to another.

  • Page 31: Installation

    Installation Grundfos CUE Mechanical installation Required free space in front of the CUE Furthermore, there must be sufficient space in front of The CUE cabinet sizes are characterised by their the CUE for opening the door of the CUE. See fig. 37.

  • Page 32: Electrical Installation

    8 AWG [10 mm Protection against short-circuit, fuses The CUE and the supply system must be protected against short-circuit. Grundfos demands that the fuses mentioned on 48 are used for protection against short-circuit.

  • Page 33
    Installation Grundfos CUE Mains and motor connection Wiring diagram, signal terminals The supply voltage and frequency are marked on the CUE nameplate. Make sure that the CUE is suitable for 0/4-20 mA 4-20 mA Terminals the electricity supply of the installation site.
  • Page 34: Rfi Filters

    • motor cable length from the frequency converter-driven motor. • the required reduction of the acoustic noise from the motor. Grundfos offers two types of output filter as accessories for the CUE: • dU/dt filters • sine-wave filters The filters are IP20/NEMA1 enclosure.

  • Page 35: Emc-Correct Installation

    Installation Grundfos CUE EMC-correct installation Typical shaft Sine-wave Pump type dU/dt filter This section gives guidelines for good practice when power P2 filter installing the CUE. Follow these guidelines to meet EN 0-1000 ft Up to 10 Hp – 61800-3, first environment.

  • Page 36
    Installation Grundfos CUE Fig. 43 Example of stripped cable with screen Fig. 44 Do not twist the screen ends Controller Fig. 45 Example of connection of a 3-conductor bus cable with screen connected at both ends Controller Fig. 46 Example of connection of a 3-conductor bus cable…
  • Page 37: Operation

    Operation Grundfos CUE Control panel Start-up guide The control panel is used for local setting of the CUE. Use the start-up guide for the general setting of the The functions available depend on the pump family. CUE including the setting of the correct direction of rotation.

  • Page 38: Warning And Alarm List

    Operation Grundfos CUE Warning and alarm list Warning The CUE will continue the operation as long as the Status warning is active. The warning remains active until the cause no longer exists. Some warnings may switch to Operat- alarm condition if the warning has been present for a…

  • Page 39: Cue Selection

    CUE selection Grundfos CUE How to select a CUE The size of the CUE is determined quickly and precisely based on the max. motor current. See fig. 48. The power size, which is the typical shaft power P2, is only an approximate value and cannot be used to select the nominal size of the CUE.

  • Page 40: Special Conditions

    CUE selection Grundfos CUE Special conditions High ambient temperature If the output current is reduced to 80 % of the nominal Derating must be taken into account when using the output current of the CUE in questions, the ambient CUE in these situations: may be 5 °C higher.

  • Page 41: Selection Tables

    CUE selection Grundfos CUE Selection tables Mains supply 1 x 200-240 V Rated CUE constant output filter enclosure CUE only Input output pressure* Enclosure conductor Efficiency rating part number dU/dt Sine wave Voltage amps part number (AWG) IP21 91136746 91136789 0.96…

  • Page 42
    CUE selection Grundfos CUE Mains supply 3 x 200-240 V Rated CUE constant output filter enclosure CUE only Input output pressure* Enclosure conductor Efficiency rating part number dU/dt Sine wave Voltage amps part number (AWG) IP21 91136747 91136790 0.95 96754973…
  • Page 43
    CUE selection Grundfos CUE Mains supply 3 x 440 — 500V Rated CUE constant output filter enclosure CUE only Input output pressure* Enclosure conductor Efficiency rating part number dU/dt Sine wave Voltage amps part number (AWG) IP21 91136762 91136805 0.95…
  • Page 44
    CUE selection Grundfos CUE Mains supply 3 x 525-600 V Rated CUE constant output filter enclosure CUE only Input output pressure* Enclosure conductor Efficiency rating part number dU/dt Sine wave Voltage amps part number (AWG) IP21 91136781 91136824 0.97 96755040…
  • Page 45: Technical Data

    Technical data Grundfos CUE Main dimensions and weight B4, C3, C4 Fig. 50 Enclosures A2 and A3 Fig. 51 Enclosures A5, B1, B2, B3, B4, C1, C2, C3 and C4 Fig. 52 Enclosures D1 and D2 Screw holes [in (mm)]…

  • Page 46
    Technical data Grundfos CUE Screw holes [in (mm)] Height [in (mm)] Width [in (mm)] Depth [in (mm)] Weight Enclosure [lb (kg)] ∅d ∅e 30.31 29.09 14.57 13.15 13.19 13.19 .472 .748 .354 .386 143.3 (770) (739) (370) (334) (335) (335) (12.0)
  • Page 47: Surroundings

    Technical data Grundfos CUE Surroundings Terminal tightening torques Relative humidity 5-95 % RH Tightening torque [Nm] Enclosure Minimum ambient temperature at full operation 32° F (0 °C) Mains Motor Ground Relay Minimum ambient temperature at reduced op- 14° F (–10 °C) eration –13°…

  • Page 48: Fuses

    Technical data Grundfos CUE Fuses Non-UL fuses and conductor cross-section to mains and motor Maximum conductor Typical shaft Maximum Fuse Maximum conductor Typical shaft Maximum Fuse power P2 fuse size type cross-section power P2 fuse size type cross-section [kW] [AWG] (mm…

  • Page 49
    Technical data Grundfos CUE UL fuses and conductor cross-section to mains and motor Fuse type Maximum conductor CUE Output Amps cross-section Bussmann Bussmann Bussmann SIBA Littel Fuse Ferraz-Shawmut Ferraz-Shawmut [Amp (kW)] [AWG] 1 x 200-240 V KTN-R20 – – –…
  • Page 50
    Technical data Grundfos CUE Fuse type Maximum conductor CUE Output Amps cross-section Bussmann Bussmann Bussmann SIBA Littel Fuse Ferraz-Shawmut Ferraz-Shawmut [Amp (kW)] [AWG] 11 (7.5) KTS-R30 JKS-30 JJS-30 5012406-032 KTN-R30 ATM-R30 A2K-30R 3 x 525-690 V – – – –…
  • Page 51: Inputs And Outputs

    Technical data Grundfos CUE Inputs and outputs Signal relays Mains supply (L1, L2, L3) Relay 01, terminal number 1 (C), 2 (NO), 3 (NC) Relay 02, terminal number 4 (C), 5 (NO), 6 (NC) Supply voltage 200-240 V ± 10 %…

  • Page 52: Accessories

    Kit* 0-580 psi (0-40 bar) 91136173 Kit* 0-870 psi (0-60 bar) 91136174 Grundfos differential pressure sensor option, 0.9 m screened cable 0-8.7 psi (0-0.6 bar) 96611522 0-14.5 psi (0-1.0 bar) 96611523 Pressure connection: 7/16” Including fittings for pressure connection (1/4″ — 7/16″), 0-23 psi (0-1.6 bar)

  • Page 53: Mcb 114 Sensor Input Module

    Accessories Grundfos CUE MCB 114 sensor input module Technical data Relative humidity 5-95% RH 14 to 131° F Ambient temperature during operation (–10 to 55° C) –13 to 158° F Temperature during storage and transportation (–25 to 70° C) Maximum length, signal cable…

  • Page 54: Grundfos Local Control Panel, Glcp

    Accessories Grundfos CUE Grundfos Local Control Panel, GLCP Remote-mounting option for GLCP GLCP is used for local setting of the CUE. By means of a remote-mounting option, the GLCP can also be moved to the front of a cabinet. The enclosure The CUE unit comes default with a GLCP fitted, but the is IP65.

  • Page 55: Floor-Mounting Option

    Accessories Grundfos CUE Floor-mounting option IP21/NEMA1 kit By means of a pedestal, the CUE can also be mounted An IP20 enclosure can be upgraded to IP21/NEMA1 on the floor. A pedestal has been designed for that pur- with the IP20/NEMA1 kit. The power terminals (mains pose.

  • Page 56: Output Filters

    Accessories Grundfos CUE Output filters Grundfos offers two types of output filter as accessories for the CUE: • dU/dt filters • sine-wave filters. The filters are in IP20/NEMA1 enclosure. Fig. 62 Wall-mounted sine-wave filters Use of output filters The table below explains in which cases an output filter is required.

  • Page 57
    Accessories Grundfos CUE Dimensions and weight of output filters Fig. 63 Wall mounting Fig. 64 Floor mounting Height [in (mm)] Width [in (mm)] Depth [in (mm)] Screw holes [in (mm)] Weight Product number Mounting ∅d ∅e [lbs (kg)] Sine-wave filters…
  • Page 58: Grundfos Differential Pressure Sensor, Dpi

    Accessories Grundfos CUE Grundfos differential pressure Wiring diagram sensor, DPI Product description A cable (pos. 1) goes through an M12 x 1.5 pg connec- tion. See fig. 65. The sensor housing and parts in contact with the medium are made of Inox DIN W.-Nr. 1.4305 (pos. 3) with composite PA top (pos.

  • Page 59: Further Product Documentation

    WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalogue • Literature •…

  • Page 60: Wincaps

    The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

  • Page 61
    Further product Grundfos CUE documentation…
  • Page 62
    Further product Grundfos CUE documentation…
  • Page 63
    Further product Grundfos CUE documentation…
  • Page 64
    1009 Subject to alterations. Rep. 1108 The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registered trademarks © 2008, 2009 Grundfos Pumps Corp. owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS Pumps Corporation GRUNDFOS Canada Inc.

(Ocr-Read Summary of Contents of some pages of the Grundfos CUE Document (Main Content), UPD: 28 March 2023)

  • 13, For single-phase connection, use L1 and L2. 6.5.8 Motor connection, enclosures B1 and B2 1. Connect the earth conductor to terminal 99 (PE). See the figure below. 2. Connect the motor conductors to terminals 96 (U), 97 (V) and 98 (W). 3. Fix the screened cable with a cable clamp. TM039020 Motor connection, B1 and B2 6.5.9 Mains connection, enclosures B3 and B4 Enclosure Torque Nm [ft-lb] Mains Motor Protective…

  • 14, Grundfos CUE 6.5.12 Motor connection, enclosures C1 and C2 1. Connect the earth conductor to terminal 99 (PE). See the figure below. 2. Connect the motor conductors to terminals 96 (U), 97 (V) and 98 (W). 3. Fix the screened cable with a cable clamp. TM039016 Mains and motor connection, C1 and C2 Related information 6.5.11 Mains connection, enclosures C1 and C2 6.5.13 Mains connection, enclosures C3 and C4 Enclosure Torque Nm [ft-…

  • 19, Grundfos CUE TM059654 Access to signal terminals, D1h and D2h 1 2 3 TM039025 Signal terminals, all enclosures 6.7.2.2 Fitting the conductor 1. Remove the insulation at a length of 9 to 10 mm. 2. Insert a screwdriver with a tip of maximum 0.4 × 2.5 mm into the square hole. 3. Insert the conductor into the corresponding round hole. Remove the screwdriver. The conductor is now fixed in the terminal. TM039026 Fitting the conductor into the signal termina…

  • 11, Related information 6.8.3.1 Enclosures A2, A3 and B3 6.8.3.2 Enclosures A5, B1, B2, B4, C1, C2, C3, C4, D1 and D2 6.5.1 Main switch A main switch can be installed before the CUE cabinet according to local regulations. See the figure in the EMC-correct installation section. Related information 6. Electrical connection 6.5.2 Wiring diagram The wires in the terminal box must be as short as possible. Excepted from this is the protective conductor which must be so long that it is the last one …

  • 31, 11. Fault finding the product 11.1 Overview of warnings and alarms Type LED indicator Warning Yellow Alarm Flashing red Trip lock Yellow and red Number Description Warning Alarm Alarm, trip lock 1 10 V low ● — — 2 Live zero error (●) (●) — 3 No motor (●) — — 4 Mains phase loss (●) (●) (●) 5 DC voltage high ● — — 6 DC voltage low ● — — 7 DC overvoltage ● ● — 8 DC undervoltage ●…

  • 12, 6.5.4 Motor connection, enclosures A2 and A3 1. Connect the earth conductor to terminal 99 (PE) on the mounting plate. 2. Connect the motor conductors to terminals 96 (U), 97 (V) and 98 (W) of the motor plug. TM074879 Connecting the earth conductor and motor conductors 1. Insert the motor plug into the socket marked «MOTOR». 2. Fix the screened cable to the mounting plate with a cable clamp. Related information 6.8.3.1 Enclosures A2, A3 and B3 6.5.5 Mains connection, e…

  • 23, 8. Control functions The display contrast can be adjusted by pressing [Status] and then pressing [Up] or [Down]. 8.1 Operating panel The operating panel consists of a display and several buttons. It enables manual setting and monitoring of the system, such as follows: • Start, stop and control of speed. • Reading of operating data and warnings and alarms. • Setting functions for the frequency converter. • Manual reset of the frequency converter. 1 AUTO ON RESET HAND ON OFF …

  • 44, Cb A a A B B VIEW B DETAIL A ø d TM077502 Dimensions for enclosure D7h Enclosure Max. height [mm] Max. width [mm] Max. depth [mm] Screw holes [mm] Weight [kg] A a B b C c ∅d ∅e f D1h 901 844 325 180 378 20 11 11 25 62 D2h 1107 1051 420 280 378 20 11 11 25 125 D5h 1324 1276 325 180 381 20 11 11 25 166 D7h 1998 1953 420 280 386 20 11 11 25 200 Shipping dimensions Enclosure Max. height [mm] Max. width [mm] Max. dept…

  • 5, Grundfos CUE If you have any questions, contact the nearest Grundfos company or service workshop. 2. Product introduction 2.1 Product description CUE is a series of external frequency converters especially designed for pumps. With the startup guide in CUE, the installer can quickly set central parameters and put CUE into operation. Connected to a sensor or an external control signal, CUE quickly adapts the pump speed to the actual demand. The operating panel displays any alarms or warnings. If the pump spee…

  • 45, 12.6.2 STO application The STO signal must be SELV or PELV supplied. European directive Machinery Directive (2006/42/EC) EN ISO 13849-1 EN IEC 62061 EN IEC 61800-5-2 EMC Directive (2004/108/EC) EN 50011 EN 61000-6-3 EN 61800-3 Low Voltage Directive (2006/95/EC) EN 50178 EN 61800-5-1 Safety standards Safety of machinery EN ISO 13849-1, IEC 62061, IEC 60204-1 Functional safety IEC 61508-1 to -7, IEC 61800-5-2 Safety function IEC 61800-5-2 (Safe Torque Off, STO) IEC 60204-1 (Stop Category 0…

  • 34, Grundfos CUE 12. Technical data 12.1 Enclosure The individual CUE cabinet sizes are characterised by their enclosures. The table shows the relationship of enclosure class and enclosure type. The enclosure can be identified on the basis of typical shaft power, voltage and IP class. Example: Read from the nameplate: • Supply voltage = 3 × 380-500 V. • Typical shaft power = 1.5 kW (2 hp). • Enclosure class = IP20. The table shows that the CUE enclosure is A2. Typical shaft power P2 Encl…

  • 37, Typical shaft power P2 Maximum fuse size Fuse type Maximum conductor cross-section 1 3 x 525-600 V 0.75 (1) 10 gG 4 1.1 (1.5) 10 gG 4 1.5 (2) 10 gG 4 2.2 (3) 20 gG 4 3 (4) 20 gG 4 4 (5) 20 gG 4 5.5 (7.5) 32 gG 4 7.5 (10) 32 gG 4 11 (15) 40 gG 10 15 (20) 40 gG 10 18.5 (25) 50 gG 10 22 (30) 60 gG 35 30 (40) 80 gG 35 37 (50) 100 gG 35 45 (60) 150 gG 50 55 (75) 160 gG 50 75 (100) 225 aR 150 90 (125) 250 aR 150 3 x 525-690 V 11 (15) 63 gG 35 1…

  • 18, 39 42 50 53 54 55 61 68 69 61 68 69 12 13 18 19 27 29 32 33 20 37 A53 U I U I A54 TM075269 3-wire sensor Terminal Type Function 12 +24 V out Supply to sensor 13 +24 V out Additional supply 18 DI 1 Digital input, programmable 19 DI 2 Digital input, programmable 20 GND Common frame for digital inputs 27 DI/O 1 Digital input/output, programmable 29 DI/O 2 Digital input/output, programmable 32 DI 3 Digital input, programmable 33 DI 4 Digital…

  • 20, OFF ON BUS TER TM039006 Setting the termination contact to ON 6.8 Connecting the signal relays As a precaution, signal cables must be separated from other cable groups by reinforced insulation in their entire lengths. TM038801 Terminals for signal relays in normal state (not activated) Terminal Function C 1 C 2 Common NO 1 NO 2 Normally open contact NC 1 NC 2 Normally closed contact 6.8.1 Access to signal relays The relay outputs are posi…

  • 3, CUE English (GB) Installation and operating instructions ………………………………………………….4 Български (BG) Упътване за монтаж и експлоатация…………………………………………………46 Čeština (CZ) Montážní a provozní návod ………………………………………………………..89 Deutsch (DE) Montage- und Betriebsanleitung ………………………………….…

  • 21, TM039442 Terminals for relay connection, B3 TM039441 Terminals for relay connection, B4 TM039440 Terminals for relay connection, C3, C4, D1h, D2h, D5h and D7h, in the upper right corner of CUE 6.8.2 Connecting the MCB 114 sensor input module MCB 114 is an option offering additional analog inputs for CUE. 6.8.2.1 Configuration of MCB 114 MCB 114 is equipped with three analog inputs for the following sensors: • One additional sensor 0/4-20 mA. • Two Pt100/Pt1000 temperature sensors for mea…

  • 27, 5. Select the required motor type (Asynchronous motor, PM Assisted Sync. Reluctance motor, IPM motor, SPM motor) and follow the startup guide. It is possible to skip the motor settings and the thermal protection parameters. Based on the motor type, the related parameters appear for adjustment. 1(1) Please select the motor of the pump or select “skip motor setup” Asynchronous motor Start-up Guide TM077492 Motor types 6. I…

  • 9, TMA06789TM006789 ELCB/RCD The circuit breaker is type B. The total leakage current of all the electrical equipment in the installation must be taken into account. The leakage current of CUE in normal operation can be seen in the electrical data section. During startup and in asymmetrical supply systems, the leakage current can be higher than normal and may cause the ELCB/RCD to trip. Related information 12.4 Electrical data 6.1.4 Motor protection The motor requires no external motor pr…

Бренд: Grundfos

Категория для инструкций: Частотные преобразователи, фильтры

Алфавит (англ.): G

Описание: Преобразователи частоты Grundfos серии CUE 0,55–90 кВт специально разработанные для управления насосами. Руководство по монтажу и эксплуатации.

Размер файла: 1712723 байт

Инструкция на преобразователи частоты Grundfos серии CUE 0,55–90 кВт

Table of Contents for Grundfos CUE Series:

  • 33 10.7.4 Signal relays 1 and 2 (3.4 and 3.5) The CUE has two signal relays. In the display below, select in which operating situations the signal relay should be activated. 10.7.5 Buttons on the CUE (3.6) The editing buttons (+, –, On/Off, OK) on the control panel can be set to these values: • Active • Not active. When set to Not active (locked), the editing buttons do not function. Set the buttons to Not active if the pump should be controlled via an external control system. Activate the buttons by pressing the arrow up and arrow down buttons s

  • 32 The table below shows the suggested controller settings: * T i = 100 seconds (factory setting). 1. Heating systems are systems in which an increase in pump performance will result in a rise in temperature at the sensor. 2. Cooling systems are systems in which an increase in pump performance will result in a drop in temperature at the sensor. L 1 = Distance in [m] between pump and sensor. L 2 = Distance in [m

  • 11 6.2.6 Enclosures B1 and B2 For information about enclosure, see table in section 16.1. Mains connection 1. Connect the ground conductor to terminal 95 (PE). See fig. 14. 2. Connect the mains conductors to the terminals 91 (L1), 92 (L2), 93 (L3). 3. Fix the mains cable with a cable clamp. Fig. 14 Mains connection, B1 and B2 Motor connection 1. Connect the ground conductor to terminal

  • 87 16.2 Dimensions principales et poids 1) Les dimensions sont poids max., largeur et profondeur. TM03 9000 2807 TM03 9002 2807 Fig. 59 Boîtiers A2 et A3 Fig. 60 Boîtiers A5, B1, B2, B3, B4, C1, C2, C3 et C4 B4, C3, C4 Puissance à l’arbre typique P2 Boîtier 1 x 200-240 V 3 x 200-240 V 3 x 380-500 V 3 x 525-600 V 3 x 525-690 V [kW] [HP] IP20 NEMA0 IP21 NEMA1 IP55 NEMA12 IP20 NEMA0 IP55 NEMA12 IP20 NEMA0 IP55 NEMA12 IP20 NEMA0 IP55 NEMA12 IP21 N

  • 53 3. Fixer le câble secteur à la plaque de montage. Fig. 9 Fixation du câble secteur 6.2.4 Branchement moteur, boîtiers A2 et A3 Pour informations sur le boîtier, voir tableau du paragr. 16.1. 1. Brancher le conducteur de mise à terre à la borne 99 (PE), sur la plaque de montage. Brancher les conducteurs moteur aux bornes 96 (U), 97 (V), 98 (W) de la fiche moteur. Fig. 10 Branchement du conducteur de mise à terre et des conducteurs moteur 2. Placer la fiche moteur dans la prise marquée MOTOR. Fixer le câble blind�

  • 14 6.3.3 Access to signal terminals All signal terminals are behind the terminal cover of the CUE front. Remove the terminal cover as shown in figs 23 and 24. Fig. 23 Access to signal terminals, A2 and A3 Fig. 24 Access to signal terminals, A5, B1, B2, B3, B4, C1, C2, C3 and C4 Fig. 25 Signal terminals (all enclosures) 6.3.4 Fitting the conductor 1. Remove the insulation at a length of 0.34 — 0.39 in (9-10 mm). 2. Insert a screwdriver with a tip of maximum 0.015 x 0.1 in (0.4 x 2.5 mm) into the square hole. 3. Insert the

  • 74 Le délai estimé jusqu’au remplacement des paliers du moteur prend en compte la réduction de vitesse de la pompe. Voir paragr. 10.7.17 Confirmation lubrification/remplacement des paliers du moteur (3.20). 10.6.12 Capteur de température 1 (2.12) Écran affiché uniquement si un module d’entrée capteur MCB 114 est installé. Cet écran affiche le point de mesure et la valeur réelle mesurée par le capteur de température 1 Pt100/Pt1000 branché au MCB 114. Le point de mesure est sélection

  • 7 4. Identification 4.1 Nameplate The CUE can be identified by means of the nameplate. An example is shown below. Fig. 1 Example of nameplate 4.2 Packaging label The CUE can also be identified by means of the label on the packaging. 5. Mechanical installation The individual CUE cabinet sizes are characterised by their enclosures. The table in section 16.1 shows the relationship of enclosure class and enclosure type. 5

  • 45 16.6.3 UL fuses and conductor cross-section (gauge size) to mains and motor 1) Screened motor cable, unscreened supply cable. 2) American Wire Gauge. Typical shaft power P2 Fuse type Maximum conductor cross-section 1) Bussmann RK1 Bussmann J Bussmann T SIBA RK1 Littel Fuse RK1 Ferraz-Shawmut CC Ferraz-Shawmut RK1 [kW] [AWG] 2) 1 x 200-240 V 1.1 KTN-R20 – – – – – – 10 1.5KTN-R30–––– – – 7 2.2KTN-R40–––

  • 49 2.3 Références Documentation technique pour le CUE Grundfos. • Le manuel comprend toutes les informations nécessaires à la mise en fonction du CUE. • La brochure d’informations comprend toutes les informations techniques concernant la construction et les applications de l’unité CUE. • Les instructions de service comprennent toutes les informa- tions pour démonter et réparer le convertisseur de fréquence. Documentation technique disponible sur www.grundfos.com > S

  • 124 Descripciones La función de parada se utiliza para cambiar entre funciona- miento on/off a bajo caudal y funcionamiento continuo a alto caudal. Fig. 50 Presión constante con función de parada. Diferencia entre las presiones de arranque y de parada (ΔH) Puede detectarse caudal bajo de dos maneras diferentes: 1. Una «función de detección de caudal bajo» integrada que fun- ciona si la entrada digital no está configurada para interruptor de caudal. 2. Un interruptor de caudal conectado a la entrada d

  • 109 9. Resumen de menús Fig. 46 Resumen de menús Estructura de menús El CUE tiene una guía de puesta en marcha, que se inicia en el primer arranque. Después de la guía de puesta en marcha, el CUE tiene una estructura de menús dividida en cuatro menús principales: 1. GENERAL da acceso a la guía de puesta en marcha para el ajuste general del CUE. 2. FUNCIONAMIENTO permite regular el punto de ajuste, seleccionar el modo de funcionamiento y reset

  • 34 Dry running When this function is selected, lack of inlet pressure or water shortage can be detected. This requires the use of an accessory, such as: • a Grundfos Liqtec ® dry-running switch • a pressure switch installed on the suction side of a pump • a float switch installed on the suction side of a pump. When lack of inlet pressure or water shortage (Dry running) is detected, the pump will be stopped. The pump cannot restart as long as the input is activated. Restarts m

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Grundfos CUE Series device using right now.

Понравилась статья? Поделить с друзьями:
  • 4g93 мануал на русском
  • Пульт автономки скания 5 серии инструкция по применению
  • Коэффициент руководства в компаниях
  • Бионекс кеми растворимый инструкция по применению отзывы
  • Скачать руководство по эксплуатации ваз в фотографиях