-
Contents
Table of Contents -
Bookmarks
Quick Links
FREQUENCY COUNTER
USER MANUAL
CONTENTS
1.
PRODUCT INTRODUCTION………………………………………
2.
3.
4.
5.
APPLICATION……………………………………………….
6.
MAINTENANCE……………………………………………..
6-2.Cleaning……………………………………………………
PAGE
1
2
4
4
4
5
6
9
11
11
12
FREQUENCY COUNTER
USER MANUAL
1. PRODUCT INTRODUCTION
The intelligent counters are measuring frequency and period from
the range of 0.01Hz to 120MHz on channel A, and 50MHz to
1.3(2.7)GHz on channel B.
The products also provide special features of high resolution and
sensitivity for value reading expediency.
1
Summary of Contents for GW Instek GFC-8131H
FREQUENCY COUNTER |
|
USER MANUAL |
|
CONTENTS |
PAGE |
1. PRODUCT INTRODUCTION……………………………………… |
1 |
2.TECHNICAL SPECIFICATION…………………………… 2
3. |
PRECAUTIONS BEFORE OPERATION…….…………… |
4 |
3-1.Unpacking the Instrument………………….…………… |
4 |
|
3-2.Checking the Line Voltage…………………..…………. |
4 |
|
3-3.Equipment Installation and Operation………………… |
5 |
|
4. |
PANEL INTRODUCTION……………………..…………… |
6 |
5.APPLICATION………………………………………………. 9
6.MAINTENANCE…………………………………………….. 11
6-1.Standard Method for Calibration……………………… |
11 |
6-2.Cleaning…………………………………………………… |
12 |
FREQUENCY COUNTER
USER MANUAL
1. PRODUCT INTRODUCTION
The intelligent counters are measuring frequency and period from the range of 0.01Hz to 120MHz on channel A, and 50MHz to 1.3(2.7)GHz on channel B.
The products also provide special features of high resolution and sensitivity for value reading expediency.
1
FREQUENCY COUNTER
USER MANUAL
2. TECHNICAL SPECIFICATIONS |
||||||
CHANNEL A |
||||||
Range |
Coupling |
AC |
DC |
|||
FREQ A |
30Hz to 120MHZ 0.01Hz to 120MHz |
|||||
PRID A |
8ns to 30ms |
8ns to 100s |
||||
50mVrms Max. to 10kHz. |
||||||
Sensitivity |
25mVrms Max. to 80MHz. |
|||||
35mVrms Max. to 120MHz. |
||||||
(rms) |
||||||
(If frequency |
10MHz, sensitivity figures are for 4 |
|||||
stable digits of reading.) |
||||||
Coupling |
AC or DC switchable. |
|||||
Filter |
Low pass, switchable in or out on channel A. |
|||||
3dB point of nominally 100kHz. |
||||||
Impedance |
1MΩ nominal shunted by less than 40pF. |
|||||
Attenuator |
×1 or ×20 nominal. |
|||||
Trigger Level |
Variable between +2.5V DC and –2.5V DC. |
|||||
Damage Level |
AC & DC ×1 |
|||||
DC to 2.4kHz |
250V(DC+AC rms) |
|||||
2.4kHz to 100kHz |
600kV rms Hz |
FREQ |
||||
100kHz |
6V rms |
|||||
AC & DC × 20 |
||||||
DC to 20kHz |
500V(DC+AC peak) |
|||||
20kHz to 100kHz |
10MV rms Hz |
FREQ. |
||||
100kHz |
100V rms |
|||||
CHANNEL B |
||||||
Range |
50MHz to 1.3GHz (GFC-8131H) |
|||||
50MHz to 2.7GHz (GFC-8270H) |
||||||
Sensitivity |
GFC-8131H |
GFC-8270H |
||||
25mVrms Max. to 80MHz |
25mVrms Max. to 80MHz |
|||||
15mVrms Max. to 700MHz |
15mVrms Max. to 1GHz |
|||||
25mVrms Max. to 1GHz |
25mVrms Max. to 2GHz |
|||||
40mVrms Max. to 1.3GHz |
50mVrms Max. to 2.7GHz |
FREQUENCY COUNTER
USER MANUAL
Coupling |
AC |
|
Impedance |
50Ω |
|
Max. Input Level |
3Vrms sine wave |
|
General |
||
Gate time displays at least 7 digits for 1s, 6 digits for |
||
100ms, 5 digits for 10ms respectively. |
||
Resolution |
The maximum resolution for frequency measurement is |
|
100nHz for 1Hz, and 0.1Hz for 100MHz input |
||
respectively, and for period measurement is 10nS for |
||
1Hz, 0.1fs (f=10-15 ) for 100MHz input respectively. |
||
Frequency————10MHz |
||
Time Base |
Aging Rate————1ppm per month |
|
Temperature———-5ppm, 23 ±5 |
||
Line Voltage———±0.005ppm for ±10% variation |
||
Accuracy |
±Resolution ± Time base error. |
|
Gate Time |
Continuously vary from 10ms to 10s or 1 period of the |
|
input depending on whichever is greater. |
||
Display |
8 digits and overflow indicators |
|
Operation |
0 ~40 |
|
Temperature |
||
Operation |
10~80% RH |
|
Humidity |
||
Power |
100/120/220/230±10%, 50/60Hz selectable internally. |
|
Requirement |
Max. consumption power is 15VA. |
|
Dimension |
Approx. 230(W) × 95(H) × 280(D) m/m. |
|
Weight |
Approx. 2.0 kgs. |
|
Instruction manual……………× 1 |
||
Accessories |
Power cord……………………× 1 |
|
Test lead GTL-101 …………..× 1 |
||
GTL-110 …………..× 1 |
FREQUENCY COUNTER
USER MANUAL
3.PRECAUTIONS BEFORE OPERATION
3-1.Unpacking the Instrument
The instrument has been fully inspected and tested before shipping from the factory. Upon receiving the instrument, please unpack and inspect it to check if there is any damages caused during transportation. If any sign of damage is found, notify the bearer and/or the dealer immediately.
3-2.Checking the Line Voltage
The instrument can be applied any kind of line voltage shown in the table below. Please check the line voltage indicated in the label attached on the real panel to replace correct fuses.
WARNING. To avoid electrical shock the power cord protective grounding conductor must be connected to ground.
When line voltages are changed, replace the required fuses shown as below:
Line voltage |
Range |
Fuse |
Line voltage |
Range |
Fuse |
100V |
90-110V |
T200mA |
220V |
198-242V |
T100mA |
120V |
108-132V |
250V |
230V |
207-253V |
250V |
WARNING. To avoid personal injury, disconnect the power cord before removing the fuse holder.
FREQUENCY COUNTER
USER MANUAL
3-3.Equipment Installation, and Operation
Ensure there is proper ventilation for the vents in the case. If this equipment is used not according to the specification, the protection provided by the equipment may be impaired.
Loading…
You can only view or download manuals with
Sign Up and get 5 for free
Upload your files to the site. You get 1 for each file you add
Get 1 for every time someone downloads your manual
Buy as many as you need
FREQUENCY COUNTER
USER MANUAL
CONTENTS PAGE
1.
PRODUCT INTRODUCTION………………………………………
1
2.
TECHNICAL SPECIFICATION……………………………
2
3.
PRECAUTIONS BEFORE OPERATION…….……………
3-1.Unpacking the Instrument………………….……………
3-2.Checking the Line Voltage…………………..………….
3-3.Equipment Installation and Operation…………………
4
4
4
5
4.
PANEL INTRODUCTION……………………..……………
6
5.
APPLICATION……………………………………………….
9
6.
MAINTENANCE……………………………………………..
6-1.Standard Method for Calibration………………………
6-2.Cleaning……………………………………………………
11
11
12
FREQUENCY COUNTER
USER MANUAL
1
1. PRODUCT INTRODUCTION
The intelligent counters are measuring frequency and period from
the range of 0.01Hz to 120MHz on channel A, and 50MHz to
1.3(2.7)GHz on channel B.
The products also provide special features of high resolution and
sensitivity for value reading expediency.
File Specifications:899/899812-gfc8131h.pdf file (30 May 2023) |
Accompanying Data:
GW Instek GFC-8131H Measuring Instruments PDF Operation & User’s Manual (Updated: Tuesday 30th of May 2023 05:17:43 AM)
Rating: 4.1 (rated by 32 users)
Compatible devices: GCM-302, PEL-3111H, GSP-9300B, LCR-6300, GSP-818-TG, GLP-1A, gpm-8212, GOM-802.
Recommended Documentation:
Operation & User’s Manual (Text Version):
(Ocr-Read Summary of Contents of some pages of the GW Instek GFC-8131H Document (Main Content), UPD: 30 May 2023)
-
1, FREQUENCY COUNTER USER MANUAL CONTENTS PAGE 1. PRODUCT INTRODUCTION……………………………………… 1 2. TECHNICAL SPECIFICATION…………………………… 2 3. PRECAUTIONS BEFORE OPERATION…….…………… 3-1.Unpacking the Instrument………………….…………… 3-2.Checking the Line Voltage…………………..…………. 3-3.Equipment Installation and Operation………………… 4 4 4 5 4. PANEL I…
-
2, GW Instek GFC-8131H FREQUENCY COUNTER USER MANUAL 2 2. TECHNICAL SPECIFICATIONS CHANNEL A Range Coupling AC DC FREQ A 30Hz to 120MHZ 0.01Hz to 120MHz PRID A 8ns to 30ms 8ns to 100s Sensitivity (rms) 50mVrms Max. to 10kHz. 25mVrms Max. to 80MHz. 35mVrms Max. to 120MHz. (If frequency < 10MHz, sensitivity figures are for 4 stable digits of reading.) Coupling AC or DC switchable. Filter Low pass, swi…
-
3, FREQUENCY COUNTER USER MANUAL 4 3.PRECAUTIONS BEFORE OPERATION 3-1.Unpacking the Instrument The instrument has been fully inspected and tested before shipping from the factory. Upon receiving the instrument, please unpack and inspect it to check if there is any damages caused during transportation. If any sign of damage is found, notify the bearer and/or the dealer immediately. 3-2.Checking the Line Voltage The instrument can be applied any kind of line…
-
4, FREQUENCY COUNTER USER MANUAL 6 4. PANEL INTRODUCTION (1). Power ON/OFF Power on or off by using the button. (2). Reset Restart counting by resetting counter to zero. (3). FREQ A Select frequency mode of operation for input A. (4). PRID A Select period mode of operation for input A. (5) FREQ B Select frequency mode of operation for input B. (6). Gate Time(LED) When Gate time LED is on, the counter’s main gate circuit is open and the measuremen…
-
5, FREQUENCY COUNTER USER MANUAL 8 z Front Panel Fig. 1 Front panel FREQUENCY COUNTER USER MANUAL 9 5. APPLICATION (1) Signal Measurements Frequency range between 0.01Hz and 120MHz, press FREQ A switch, then connect input signal to the channel A input BNC. Frequency range between 50MHz and 1.3(2.7) GHz, press FREQ B switch, then connect input signal to the channel B input BNC. Press “PRID” switch to select period mode of operation for …
-
6, FREQUENCY COUNTER USER MANUAL 10 (4) LP FILTER An unstable reading is caused from measuring noise of low frequency signals on channel A. The LP FILTER minimizes high frequency noise, permitting the counter to measure only the desired low frequency component. For more stable reading, insert a 100kHz low pass filter into the channel A input circuit by pushing in the LP FILTER button. (5) Attenuator An attenuator is provided in the channel A input …
-
7, FREQUENCY COUNTER USER MANUAL 12 6-2.Cleaning To clean the instrument, use a soft cloth dampened in a solution of mild detergent and water. Do not spray cleaner directly onto the instrument because it may leak into the cabinet and cause damage. Do not use chemicals containing benzine, benzene, toluene, xylene, acetone, or similar solvents. Do not use abrasive cleaners on any portion of the instrument.
…
-
GW Instek GFC-8131H User Manual
-
GW Instek GFC-8131H User Guide
-
GW Instek GFC-8131H PDF Manual
-
GW Instek GFC-8131H Owner’s Manuals
Recommended: VIVICAM T024, PIXMA MP860, 260, GLS-ODT-C-2000, XT20sx4.7 BRM exceed series
Links & Tools
Operating Impressions, Questions and Answers:
FREQUENCY COUNTER
USER MANUAL
CONTENTS PAGE
1. PRODUCT INTRODUCTION……………..……………….……… 1
2. TECHNICAL SPECIFICATION…………………………… 2
3. PRECAUTIONS BEFORE OPERATION…….……………
3-1.Unpacking the Instrument………………….……………
3-2.Checking the Line Voltage…………………..………….
3-3.Equipment Installation and Operation…………………
4
4
4
5
4. PANEL INTRODUCTION……………………..…………… 6
5. APPLICATION………………………………………………. 9
6. MAINTENANCE……………………………………………..
6-1.Standard Method for Calibration………………………
6-2.Cleaning……………………………………………………
11
11
12
FREQUENCY COUNTER
USER MANUAL
1
1. PRODUCT INTRODUCTION
The intelligent counters are measuring frequency and period from
the range of 0.01Hz to 120MHz on channel A, and 50MHz to
1.3(2.7)GHz on channel B.
The products also provide special features of high resolution and
sensitivity for value reading expediency.