Ge d60 руководство по эксплуатации

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Title Page

GE Multilin

215 Anderson Avenue, Markham, Ontario

Canada L6E 1B3

Tel: (905) 294-6222 Fax: (905) 201-2098

Internet:

http://www.GEindustrial.com/multilin

D60 Line Distance Relay

Instruction Manual

D60 Revision: 4.6x

Manual P/N: 1601-0089-K1 (GEK-113007)

Copyright © 2005 GE Multilin

GE Industrial Systems

837766A1.CDR

ISO9001:2000

GE Multilin’s Quality Management

System is registered to

ISO9001:2000

QMI # 005094

UL # A3775

loading

Summary of Contents for GE D60

File Reference Title Publish Date Format 1601-0089-AN2 D60 Instruction Manual for 8.4x (Rev. AN2) 2023-07-06  [21M] 1601-0401-AN1 UR Family Communication Guide 8.4x (Rev. AN1) 2022-12-22  [5.4M] 1601-0089-AM2 D60 Instruction Manual for 8.3x (Rev. AM2) 2022-10-25  [19.8M] 1601-0401-AM2 UR Family Communication Guide 8.3x (Rev. AM2) 2022-10-25  [3.9M] 1601-0905-A2 UR Family Enhanced to Graphical Front Panel Retrofit Instructions 2021-05-05  [1.7M] 1601-0089-AL2 D60 instruction manual for 8.2x product version (Rev. AL2) 2021-07-29  [19.5M] 1601-0089-AL1 D60 instruction manual for 8.2x product version (Rev. AL1) (Русский) 2022-01-31  [53.3M] 1601-0401-AL2 UR Family Communication Guide 8.2x (Rev. AL2) 2021-07-29  [3.8M] 1601-0089-AK1 D60 instruction manual for 8.1x product version (Rev. AK1) 2020-12-24  [20.7M] 1601-0401-AK1 UR Family Communication Guide 8.1x (Rev. AK1) 2020-12-24  [3.8M] 1601-0401-AJ3 UR Family Communication Guide 8.0x (Rev. AJ3) 2020-09-18  [3.7M] 1601-0089-AJ3 D60 instruction manual for 8.0x product version (Rev. AJ3) 2020-09-18  [20.3M] 1601-0089-AI3 D60 Instruction Manual for 7.9x (Rev. AI3) 2020-10-22  [19.6M] 1601-0401-AI3 UR Family Communication Guide 7.9x (Rev AI3) 2020-10-22  [3.7M] GEK-131055 D60 instruction Manual for 7.8x (Rev. AH1) 2019-02-27  [18.8M] GEK-131048 UR Family Communication Guide 7.8x 2019-02-27  [3.6M] GEK-130951 UR D60 7.6x Instruction Manuals (Język polski) (Rev. AF2) 2018-06-01  [31.8M] 1601-0089-X6 D60 Instruction Manual for 6.0x product version (Rev. X6) 2021-09-09  [15.5M] GEK-131036A D60 Instruction Manual for 7.7x product version (Rev. AG2) 2018-05-28  [15.5M] GEK-131029A UR Series Communications Guide for 7.7x 2018-05-28  [4.1M] 1601-0089-AF3 D60 Instruction Manual for 7.6x product version (Rev. AF3) 2021-09-09  [49.9M] 1601-0401-AF3 UR Series Communications Guide for 7.6x 2021-09-09  [3.5M] 1601-0089-AE4 D60 Instruction Manual for 7.4x product version (Rev. AE4) 2021-04-08  [46.8M] 1601-0401-AE4 UR Series Communications Guide for 7.4x 2021-04-08  [3.3M] 1601-0089-AB3 D60 Instruction Manual for 7.3x product version (Rev. AB3) 2021-04-08  [15M] 1601-0401-AB3 UR Series Communications Guide for 7.3x 2021-04-08  [2.5M] 1601-0089-AA7 D60 Instruction Manual for 7.2x product version (Rev. AA7) 2021-09-09  [15.7M] GEK-119515C D60 Instruction Manual for 7.1x product version (Rev. Z4) 2020-01-20  [12.9M] GEK-113665C D60 Instruction Manual for 7.0x product version (Rev. Y4) 2015-09-29  [12M] GEK-113377B D60 instruction manual for 5.9x product version (Rev. W3) 2019-04-15  [12.7M] GEK-113549B D60 instruction manual for 5.8x product version (Rev. V3) 2019-04-15  [11.7M] GEK-113519D D60 instruction manual for 5.7x product version (Rev. U5) 2019-04-15  [11.7M] GEK-113482B D60 instruction manual for 5.6x product version (Rev. T3) 2019-02-08  [13.2M] GEK-113411E D60 instruction manual for 5.5x product version (Rev. S6) 2019-03-28  [11.2M] GEK-113317A D60 Instruction Manual for 5.2x product version (Rev. P2) 2014-11-24  [9.4M] GEK-113007 D60 instruction manual for 4.6x product version (Rev. K1) 2005-03-03  [6.5M] GEK-113204 D60 instruction manual for 4.9x product version (Rev. M2) 2006-03-07  [9.1M] GEK-106440D D60 Instruction Manual for 3.4x product (Rev. F5) 2010-05-07  [7.6M] GEK-119681 D60 Instruction Manual for 7.6x product version (日本語) (Rev. AF2) 2018-03-16  [61.5M] GEK-131021 UR Series Communications Guide for 7.6x (日本語) 2018-03-16  [4.4M] GEK-113430A D60 Manuel d’Instructions pour la version 5.5x (français) (Rev. S2) 2010-01-19  [10.2M] GEK-113177 D60 Manuel d’Instructions pour la version 5.2x (français) (Rev. P1) 2006-11-21  [8.2M] GEK-106522 D60 Manuel d’Instructions pour la version 3.4x (français) (Rev. F1) 2005-04-12  [6.5M] GEK-119601 D60 Instruction Manual for 6.0x (Русский) (Rev. X1) 2013-11-26  [34.3M] GEK-113299A D60 Instruction Manual for 5.7x (Русский) (Rev. U2) 2010-08-12  [25.4M] GEK-113222 D60 Instruction Manual for 5.2x (Русский) (Rev. P1) 2007-04-20  [12.3M] GEK-113070 D60 Instruction Manual for 4.6x product version (简体中文) (Rev. K1) 2005-05-19  [9M] GEK-113608 D60 Instruction Manual for 6.0x product version (Türkçe) (Rev. X1) 2012-12-19  [15.6M] GEK-119577A D60 Instruction Manual for 7.2x product version (Deutsch) (Rev. AA2) 2015-01-21  [17.3M] GEK-113422 UR Switch Module Instruction Manual (Rev. A1) 2008-07-25  [9M] GEK-113423 UR Switch Module Quickstart Guide (Rev. A1) 2008-07-25  [3.7M] GEK-119546D UR Series IP20 Cover Installation Instructions 2018-01-18  [2.3M] GEK-119570 Gamme de relais UR Capot IP20 Guide d’Installation (français) 2013-06-28  [1.7M] 1601-0724-A1 UR Series IP54 Front Panel Remote Mounting Instructions 2021-01-25  [1.5M] GEK-113180 UR-V Front panel assembly instructions 2008-11-24  [161k] UR-series UR-V side-mounting front panel assembly instructions GEK-113181B Front panel vertical mounting instruction sheet 2018-01-12  [680k] Connecting the side-mounted UR-V enhanced front panel to a vertical UR-series device GEK-113182B Front panel horizontal mounting instruction sheet 2018-01-12  [790k] Connecting the side-mounted UR-V enhanced front panel to a vertically-mounted horizontal UR-series device 1601-0904-A2 UR Family Basic to Enhanced or Graphical Front Panel Retrofit Instructions 2021-05-05  [1.9M] 1601-0910 UR Family Secure Deployment Guide (Rev. A2) 2021-05-05  [782k] Applies to version 8.1 and above

Table of Contents for GE D60:

  • C-10 D60 Line Distance Protection System GE Multilin C.4 GENERIC SUBSTATION EVENT SERVICES: GSSE AND GOOSE APPENDIX C C C.4.5 ETHERNET MAC ADDRESS FOR GSSE/GOOSE Ethernet capable devices each contain a unique identifying address called a Media Access Control (MAC) address. This address cannot be changed and is unique for each Ethernet device produced worldwide. The address is six bytes in length and is usually represented as six hexadecimal values (for example, 00 A0 F4 01 02 03). It is used in all Ethernet frames as the ‘source’ addres

  • G-4 D60 Line Distance Protection System GE Multilin G.1 CHANGE NOTES APPENDIX G G 5- 5-91 Add Added UR Synchrophasor Implementation of IEC61850-90-5 to the PMU software option description 5-91 5-91 Update Updated Figure: Complete Synchrophasor Implementation 5- 5-92 Add Added Figure: N60 Support For Four Logical Device PMU 5-92 5-92 Update Updated Table: Implementation By Model Number 5- 5-93 Add Added Figure: Lo

  • 5-128 D60 Line Distance Protection System GE Multilin 5.4 SYSTEM SETUP 5 SETTINGS 5 PATH: SETTINGS  SYSTEM SETUP  PHASOR MEASUREMENT UNIT PMU AGGREGATOR 1 90-5 AGGR 1 CONFIGU- RATION • PMU AGGREGATOR1 PROTOCOL: This setting selects if the IEEE C37.118 or IEC 61850 standard is used. • PMU AGGREGATOR1 IDCODE: Numeric identifier of the Aggregator / PDC function. In an IEEE C37.118 output stream, this identifies th

  • GE Multilin D60 Line Distance Protection System 1-17 1 GETTING STARTED 1.3 ENERVISTA UR SETUP SOFTWARE 1 If using EnerVista, navigate to Settings > Product Setup > Security. Change the Local Administrator Password, for example. It is strongly recommended that the password for the Administrator be changed from the default. Changing the passwords for the other three roles is optional. Figure 1–11: CHANGING THE DEFAULT PASSWORD

  • GE Multilin D60 Line Distance Protection System 6-7 6 ACTUAL VALUES 6.2 STATUS 6 b) STATISTICS PATH: ACTUAL VALUES  STATUS  REMOTE DEVICES STATISTICS  REMOTE DEVICE 1(16) Statistical data (two types) for up to 16 programmed remote devices is shown here. The STNUM number is obtained from the indicated remote device and increments whenever a change of state of at least one item

  • GE Multilin D60 Line Distance Protection System 5-295 5 SETTINGS 5.7 CONTROL ELEMENTS 5 The OPEN POLE REM CURR PKP setting specifies pickup level for the remote-end current estimated by the relay as the local current compensated by the calculated charging current. The latter is calculated based on the local voltages and the capac- itive reactances of the line. This setting is relevant if open pole condition at the remote end of the line is to b

  • GE Multilin D60 Line Distance Protection System B-39 APPENDIX B B.4 MEMORY MAPPING B 66C6 Load Encroachment Reset Delay 0 to 65.535 s 0.001 F001 0 66C7 Load Encroachment Block 0 to 4294967295 — 1 F300 0 66C9 Load Encroachment Target 0 to 2 — 1 F109 0 (Self-reset) 66CA Load Encroachment Events 0 to 1 — 1 F102 0 (Disabled) 66CB Reserved (6 items) 0 to 65535 — 1 F001 0 Trip Output (Read/Write Setting) 6760 Trip Mode 0 to 2 — 1 F195 0 (Disabled) 6761 Trip 3-Pole Input1 0 to 4294967295 — 1 F300 0 6763 Trip 3-Pole Input2 0 to 4294967295 — 1 F300 0 6

  • GE Multilin D60 Line Distance Protection System B-79 APPENDIX B B.4 MEMORY MAPPING B E280 …Repeated for PMU Aggregator 3 E2B0 …Repeated for PMU Aggregator 4 Phasor Measurement Unit Recording Command (Read/Write Command) E4D4 PMU 1 Recording Clear Command 0 to 1 — 1 F126 0 (No) E4D5 PMU 1 Recording Force Trigger 0 to 1 — 1 F126 0 (No) Phasor Measurement Unit Recording (Read/Write Setting) E4DC PMU 1 Record Function 0 to 1 — 1 F102 0 (Disa

  • ii D60 Line Distance Protection System GE Multilin INDEX CLEANING…………………………………………………………….. 2-29 CLEAR RECORDS ……………………………………………. 5-25, 7-2 CLEAR RELAY RECORDS Modbus registers …………………………………………………..B-69 settings ……………………………………………………………….5-25 CLOCK setting date and time ……………………………………………….7-2 settin

  • GE Multilin D60 Line Distance Protection System 3-27 3 HARDWARE 3.3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 3.3.2 FIBER: LED AND ELED TRANSMITTERS The following figure shows the configuration for the 7A, 7B, 7C, 7H, 7I, and 7J fiber-only modules. Figure 3–28: LED AND ELED FIBER MODULES 3.3.3 FIBER-LASER TRANSMITTERS The following figure shows the configuration for the 72, 73, 7D, and 7K fiber-laser module. Figure 3–29: LASER FIBER MODULES When using a laser

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of GE D60 device using right now.

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Title Page

g

GE Multilin

215 Anderson Avenue, Markham, Ontario

Canada L6E 1B3

Tel: (905) 294-6222 Fax: (905) 201-2098

Internet:

http://www.GEindustrial.com/multilin

D60 Line Distance Relay

Instruction Manual

D60 Revision: 4.9x

Manual P/N: 1601-0089-M2 (GEK-113204A)

Copyright © 2006 GE Multilin

GE Industrial Systems

837766A1.CDR

ISO9001:2000

GE Multilin’s Quality Management

System is registered to

ISO9001:2000

QMI # 005094

UL # A3775

loading

Summary of Contents for GE D60

(Ocr-Read Summary of Contents of some pages of the GE D60 Document (Main Content), UPD: 20 April 2023)

  • 729, GE Multilin D60 Line Distance Protection System B-107 APPENDIX B B.4 MEMORY MAPPING B 299 RBRF11.ST.OpEx.general 300 RBRF11.ST.OpIn.general 301 RBRF12.ST.OpEx.general 302 RBRF12.ST.OpIn.general 303 RBRF13.ST.OpEx.general 304 RBRF13.ST.OpIn.general 305 RBRF14.ST.OpEx.general 306 RBRF14.ST.OpIn.general 307 RBRF15.ST.OpEx.general 308 RBRF15.ST.OpIn.general 309 RBRF16.ST.OpEx.general 310 RBRF16.ST.OpIn.general 311 RBRF17.ST.OpEx.general 312 RBRF17.ST.Op…

  • 322, GE D60 5-188 D60 Line Distance Protection System GE Multilin 5.6 GROUPED ELEMENTS 5 SETTINGS 5 Figure 5–85: GROUND DISTANCE ZONES 2 AND HIGHER SCHEME LOGIC GROUND DIRECTIONAL SUPERVISION: A dual (zero-sequence and negative-sequence) memory-polarized directional supervision applied to the ground distance protection elements has been shown to give good directional integrity. However, a reverse double-line-to-ground fault can lead to a maloperation of the ground element in a sound phase if the zo…

  • 263, GE Multilin D60 Line Distance Protection System 5-129 5 SETTINGS 5.4 SYSTEM SETUP 5 • PMU 1 VA… IG CALIBRATION MAGNITUDE: These settings recognize applications with protection class voltage and current sources, and allow the user to calibrate each channel (four voltages and four currents) individually to offset errors introduced by VTs, CTs. The setting values are effectively a multiplier of the measured magnitudes. Therefore, enter a multiplier …

  • 656, B-34 D60 Line Distance Protection System GE Multilin B.4 MEMORY MAPPING APPENDIX B B 4446 User Programmable Battery Fail Function 0 to 1 — 1 F102 1 (Enabled) 4447 User Programmable SNTP Fail Function 0 to 1 — 1 F102 1 (Enabled) 4448 User Programmable IRIG-B Fail Function 0 to 1 — 1 F102 1 (Enabled) 444A Process Bus Failure Operand 0 to 4294967295 — 1 F300 0 444C PTP Fail Function 0 to 1 -…

  • 12, 1-2 D60 Line Distance Protection System GE Multilin 1.1 IMPORTANT PROCEDURES 1 GETTING STARTED 1 1.1.2 INSPECTION PROCEDURE 1. Open the relay packaging and inspect the unit for physical damage. 2. View the rear nameplate and verify that the correct model has been ordered and delivered. The model number is at the top right. Figure 1–1: REAR NAMEPLATE (EXAMPLE) 3. Ensure that the following items are included: • Instructi…

  • 318, 5-184 D60 Line Distance Protection System GE Multilin 5.6 GROUPED ELEMENTS 5 SETTINGS 5 on the parallel line. Mutual coupling compensation is applied when distance source is assigned with 8F or 8L type DSP module only and when the ratio of the protected line ground current to parallel line ground current is greater than 1.22. • GND DIST Z1 ZOM/Z1 ANG: This setting specifies the angle difference between the mutual zero-sequence imped- ance betwe…

  • 113, GE Multilin D60 Line Distance Protection System 4-11 4 HUMAN INTERFACES 4.2 EXTENDED ENERVISTA UR SETUP FEATURES 4 The following window is displayed. Figure 4–10: TYPICAL SETTINGS FILE PROPERTIES WINDOW 3. Enter the serial number of the D60 device to lock to the settings file in the Serial # Lock field. The settings file and corresponding secure FlexLogic equations are now locked to the D60 device specified by the serial number. 4.2.3 SETTINGS FILE …

  • 410, 5-276 D60 Line Distance Protection System GE Multilin 5.7 CONTROL ELEMENTS 5 SETTINGS 5 If one or both sources are de-energized, the synchrocheck programming can allow for closing of the circuit breaker using undervoltage control to by-pass the synchrocheck measurements (dead source function). • SYNCHK1 V1 SOURCE: This setting selects the source for voltage V1 (see NOTES below). • SYNCHK1 V2 SOURCE: This setting selects the source for voltage V2, which must not be the same as used for the V1…

  • 198, 5-64 D60 Line Distance Protection System GE Multilin 5.2 PRODUCT SETUP 5 SETTINGS 5 5.2.5 MODBUS USER MAP PATH: SETTINGS  PRODUCT SETUP  MODBUS USER MAP The Modbus user map provides read-only access for up to 256 registers. To obtain a memory map value, enter the desired address in the ADDRESS line (converted from hex to decimal format). The corresponding value displays in the VALUE line. A value of “0” in subsequent regi…

  • 280, 5-146 D60 Line Distance Protection System GE Multilin 5.5 FLEXLOGIC 5 SETTINGS 5 ELEMENT: Directional comparison unblocking scheme DCUB TX1 DCUB TX2 DCUB TX3 DCUB TX4 DCUB TRIP A DCUB TRIP B DCUB TRIP C DCUB TRIP 3P DCUB OP Directional comparison unblocking scheme asserts transmit bit 1 Directional comparison unblocking scheme asserts transmit bit 2 Directional comparison unblocking scheme asserts transmit bit 3 Directional comparis…

  • 794, F-2 D60 Line Distance Protection System GE Multilin F.1 DEVICE PROFILE DOCUMENT APPENDIX F F Requires Application Layer Confirmation:  Never  Always  When reporting Event Data  When sending multi-fragment responses  Sometimes  Configurable Timeouts while waiting for: Data Link Confirm:  None  Fixed at ____  Variable  Configurable Complete Appl. Fragment:  None  Fixed at ____  Variable  Configurable Application Confirm:  None  F…

  • 521, GE Multilin D60 Line Distance Protection System 6-13 6 ACTUAL VALUES 6.3 METERING 6 6.3METERING 6.3.1 METERING CONVENTIONS a) UR CONVENTION FOR MEASURING POWER AND ENERGY The following figure illustrates the conventions established for use in UR-series relays. Figure 6–1: FLOW DIRECTION OF SIGNED VALUES FOR WATTS AND VARS 827239AC.CDR PER IEEE CONVENTIONS PARAMETERS AS SEEN BY THE UR RELAY Voltage WATTS = Positive VARS = Positive PF = Lag Cu…

  • 526, 6-18 D60 Line Distance Protection System GE Multilin 6.3 METERING 6 ACTUAL VALUES 6 The metered phase voltage values are displayed in this menu. The «SRC 1» text will be replaced by whatever name was programmed by the user for the associated source (see SETTINGS  SYSTEM SETUP  SIGNAL SOURCES). e) AUXILIARY VOLTAGE METERING PATH: ACTUAL VALUES  METERING  SOURCE SRC 1  AUXILIARY VOLTAGE The met…

  • 402, GE D60 5-268 D60 Line Distance Protection System GE Multilin 5.7 CONTROL ELEMENTS 5 SETTINGS 5 • TRIP PILOT PRIORITY: This setting is used to set an interval equal to the inter-relay channel communications time, plus a margin, during which outputs are not asserted. This delay permits fault identification information from a remote terminal to be used instead of local data only. • REVERSE FAULT: Use this setting to guarantee accuracy of single-pole tripping under evolving external to …

  • 248, GE D60 5-114 D60 Line Distance Protection System GE Multilin 5.4 SYSTEM SETUP 5 SETTINGS 5 Figure 5–33: RECLOSER CURVES GE101 TO GE106 Figure 5–34: RECLOSER CURVES GE113, GE120, GE138 AND GE142 GE104 1 1.2 1.5 2 2.5 3 4 5 6 7 8 9 10 12 15 20 0.01 0.02 0.05 0.1 0.2 0.5 1 2 CURRENT (multiple of pickup) TIME (sec) GE101 GE102 GE103 GE106 GE105 842723A1.CDR 1 1.2 1.5 2 2.5 3 4 5 6 7 8 9 10 12 15 20 0.05 0.1 0.2 0.…

  • 644, B-22 D60 Line Distance Protection System GE Multilin B.4 MEMORY MAPPING APPENDIX B B Fault Report Indexing (Read Only Non-Volatile) 3020 Number of Fault Reports 0 to 65535 — 1 F001 0 Fault Report Actuals (Read Only Non-Volatile) (15 Modules) 3030 Fault Report 1 Time 0 to 4294967295 — 1 F050 0 3032 Fault Report 2 Time 0 to 4294967295 — 1 F050 0 3034 Fault Report 3 Time 0 to 4294967295 — 1 F050 0 3036 Fault Report 4 Time 0 to 4294967295 — …

  • 665, GE D60 GE Multilin D60 Line Distance Protection System B-43 APPENDIX B B.4 MEMORY MAPPING B 6767 Trip 3-Pole Input4 0 to 4294967295 — 1 F300 0 6769 Trip 3-Pole Input5 0 to 4294967295 — 1 F300 0 676B Trip 3-Pole Input6 0 to 4294967295 — 1 F300 0 676D Trip 1-Pole Input1 0 to 4294967295 — 1 F300 0 676F Trip 1-Pole Input2 0 to 4294967295 — 1 F300 0 6771 Trip 1-Pole Input3 0 to 4294967295 — 1 F300 0 6773 Trip 1-Pole Input4 0 to 4294967295 — 1 F300 0 6775 Trip …

  • 442, 5-308 D60 Line Distance Protection System GE Multilin 5.7 CONTROL ELEMENTS 5 SETTINGS 5 Figure 5–158: BREAKER RESTRIKE SCHEME LOGIC RUN Current interruption detection logic <0.05pu for > ¼ cycle I t mag ARMED RESET SETTING = Enabled BREAKER RESTRIKE 1 FUNCTION SETTING =Off BKR RSTR 1 BLK AND SETTING =IA BREAKER RESTRIKE 1 SOURCE =IB =IC SETTING =Off BKR RSTR 1 BKR OPEN SETTING =Off BKR RSTR 1 OPEN CMD SETTING =Off BKR RSTR …

Понравилась статья? Поделить с друзьями:
  • Приказ мо рф 300 руководство по учету вооружения техники
  • Сироп энцефабол для детей инструкция по применению цена
  • Бронхо ваксом 7мг инструкция отзывы цена
  • Возврат налога с ипотеки пошаговая инструкция через госуслуги
  • Общее руководство гражданской обороной в российской федерации осуществляет министр