Ga7ff atlas copco инструкция по эксплуатации

Oil-injected rotary screw compressors

GA 5, GA 7, GA 11

Instruction book

Atlas Copco

Oil-injected rotary screw compressors

GA 5, GA 7, GA 11

From following serial No. onwards: CAI 700 000

Instruction book

Original instructions

Copyright notice

Any unauthorized use or copying of the contents or any part thereof is prohibited.

This applies in particular to trademarks, model denominations, part numbers and drawings.

This instruction book is valid for CE as well as non-CE labelled machines. It meets the requirements for instructions specified by the applicable European directives as identified in the Declaration of Conformity.

2009 — 12

No. 2920 7090 51

Replaces No. 2920 7090 50

www.atlascopco.com

Instruction book

2

Table of contents

2

2.1

2.2

2.3

2.4

2.5

2.6

2.7

2.8

2.9

3

3.1

3.2

3.3

3.4

3.5

3.6

3.7

3.8

3.9

1

1.1

1.2

1.3

1.4

1.5

Safety precautions…………………………………………………………………………………………….7

S

AFETY ICONS

…………………………………………………………………………………………………………………..7

S

AFETY PRECAUTIONS

,

GENERAL

……………………………………………………………………………………………..7

S

AFETY PRECAUTIONS DURING INSTALLATION

……………………………………………………………………………….7

S

AFETY PRECAUTIONS DURING OPERATION

………………………………………………………………………………….9

S

AFETY PRECAUTIONS DURING MAINTENANCE OR REPAIR

……………………………………………………………….10

General description…………………………………………………………………………………………12

I

NTRODUCTION

…………………………………………………………………………………………………………………12

A

IR FLOW

………………………………………………………………………………………………………………………16

O

IL SYSTEM

……………………………………………………………………………………………………………………17

C

OOLING SYSTEM

……………………………………………………………………………………………………………..18

C

ONDENSATE SYSTEM

………………………………………………………………………………………………………..19

R

EGULATING SYSTEM

…………………………………………………………………………………………………………20

E

LECTRICAL SYSTEM

………………………………………………………………………………………………………….20

E

LECTRICAL DIAGRAMS

……………………………………………………………………………………………………….21

A

IR DRYER

……………………………………………………………………………………………………………………..24

Elektronikon® controller………………………………………………………………………………….26

E

LEKTRONIKON

®

REGULATOR

……………………………………………………………………………………………….26

C

ONTROL PANEL

………………………………………………………………………………………………………………27

I

CONS USED ON THE DISPLAY

………………………………………………………………………………………………..28

M

AIN SCREEN

………………………………………………………………………………………………………………….30

S

HUT

DOWN WARNING

………………………………………………………………………………………………………..30

S

HUT

DOWN

……………………………………………………………………………………………………………………32

S

ERVICE WARNING

…………………………………………………………………………………………………………….33

S

CROLLING THROUGH ALL SCREENS

………………………………………………………………………………………..35

C

ALLING UP OUTLET AND DEWPOINT TEMPERATURES

…………………………………………………………………….38

2920 7090 51

Instruction book

4

4.1

4.2

4.3

4.4

3.25

3.26

3.27

3.28

3.29

3.30

3.31

3.32

3.33

3.20

3.21

3.22

3.23

3.24

3.15

3.16

3.17

3.18

3.19

3.10

3.11

3.12

3.13

3.14

C

ALLING UP RUNNING HOURS

………………………………………………………………………………………………..39

C

ALLING UP MOTOR STARTS

…………………………………………………………………………………………………40

C

ALLING UP MODULE HOURS

…………………………………………………………………………………………………41

C

ALLING UP LOADING HOURS

………………………………………………………………………………………………..41

C

ALLING UP LOAD RELAY

…………………………………………………………………………………………………….41

C

ALLING UP

/

RESETTING THE SERVICE TIMER

……………………………………………………………………………..42

S

ELECTION BETWEEN LOCAL

,

REMOTE OR

LAN

CONTROL

………………………………………………………………43

C

ALLING UP

/

MODIFYING

CAN

ADDRESS CONTROL

……………………………………………………………………….43

C

ALLING UP

/

MODIFYING

IP, G

ATEWAY AND

S

UBNETMASK

………………………………………………………………45

C

ALLING UP

/

MODIFYING PRESSURE BAND SETTINGS

………………………………………………………………………47

M

ODIFYING THE PRESSURE BAND SELECTION

……………………………………………………………………………..48

C

ALLING UP

/

MODIFYING SERVICE TIMER SETTINGS

………………………………………………………………………..49

C

ALLING UP

/

MODIFYING THE UNIT OF TEMPERATURE

……………………………………………………………………..49

C

ALLING UP

/

MODIFYING UNIT OF PRESSURE

……………………………………………………………………………….50

A

CTIVATING AUTOMATIC RESTART AFTER VOLTAGE FAILURE

…………………………………………………………….50

S

ELECTION BETWEEN

Y-D

OR

DOL

STARTING

…………………………………………………………………………..50

C

ALLING UP MODIFYING LOAD DELAY TIME

…………………………………………………………………………………51

C

ALLING UP MODIFYING MINIMUM STOP TIME

………………………………………………………………………………51

A

CTIVATING PASSWORD PROTECTION

………………………………………………………………………………………52

A

CTIVATE LOAD

/

UNLOAD REMOTE PRESSURE SENSING

…………………………………………………………………..52

C

ALLING UP

/

MODIFYING PROTECTION SETTINGS

…………………………………………………………………………..53

T

EST SCREENS

………………………………………………………………………………………………………………..55

W

EB SERVER

………………………………………………………………………………………………………………….56

P

ROGRAMMABLE SETTINGS

…………………………………………………………………………………………………..64

Elektronikon® Graphic controller…………………………………………………………………….68

E

LEKTRONIKON

®

G

RAPHIC CONTROLLER

…………………………………………………………………………………..68

C

ONTROL PANEL

………………………………………………………………………………………………………………70

I

CONS USED

……………………………………………………………………………………………………………………71

M

AIN SCREEN

………………………………………………………………………………………………………………….74

2920 7090 51 3

Instruction book

7

7.1

7.2

7.3

6.1

6.2

6.3

6.4

5

5.1

5.2

5.3

6

4.10

4.11

4.12

4.13

4.14

4.15

4.16

4.17

4.18

4.5

4.6

4.7

4.8

4.9

C

ALLING UP MENUS

…………………………………………………………………………………………………………..76

I

NPUTS MENU

…………………………………………………………………………………………………………………..77

O

UTPUTS MENU

……………………………………………………………………………………………………………….78

C

OUNTERS

……………………………………………………………………………………………………………………..80

S

ERVICE MENU

………………………………………………………………………………………………………………..81

S

ETPOINT MENU

……………………………………………………………………………………………………………….85

E

VENT HISTORY MENU

………………………………………………………………………………………………………..87

M

ODIFYING GENERAL SETTINGS

……………………………………………………………………………………………..88

I

NFO MENU

……………………………………………………………………………………………………………………..89

W

EEK TIMER MENU

……………………………………………………………………………………………………………90

T

EST MENU

…………………………………………………………………………………………………………………….99

U

SER PASSWORD MENU

…………………………………………………………………………………………………….100

W

EB SERVER

………………………………………………………………………………………………………………..101

P

ROGRAMMABLE SETTINGS

…………………………………………………………………………………………………109

OSD oil/condensate separator (optional)………………………………………………………..113

OSD

UNIT

……………………………………………………………………………………………………………………113

O

PERATING AND MAINTENANCE INSTRUCTIONS

………………………………………………………………………….114

P

ICTOGRAPHS

……………………………………………………………………………………………………………….115

Installation…………………………………………………………………………………………………….117

D

IMENSION DRAWINGS

………………………………………………………………………………………………………117

I

NSTALLATION PROPOSAL

…………………………………………………………………………………………………..123

E

LECTRICAL CONNECTIONS

…………………………………………………………………………………………………126

P

ICTOGRAPHS

……………………………………………………………………………………………………………….131

Operating instructions…………………………………………………………………………………..133

I

NITIAL START

UP

…………………………………………………………………………………………………………….133

B

EFORE STARTING

…………………………………………………………………………………………………………..135

S

TARTING

……………………………………………………………………………………………………………………136

4 2920 7090 51

Instruction book

10

11

9

9.1

9.2

9.3

9.4

9.5

9.6

9.7

9.8

8.1

8.2

8.3

8.4

8.5

7.4

7.5

7.6

7.7

8

D

URING OPERATION

…………………………………………………………………………………………………………137

C

HECKING THE DISPLAY

…………………………………………………………………………………………………….139

S

TOPPING

……………………………………………………………………………………………………………………140

T

AKING OUT OF OPERATION

………………………………………………………………………………………………..141

Maintenance………………………………………………………………………………………………….143

P

REVENTIVE MAINTENANCE SCHEDULE

……………………………………………………………………………………143

O

IL SPECIFICATIONS

…………………………………………………………………………………………………………146

S

TORAGE AFTER INSTALLATION

……………………………………………………………………………………………146

S

ERVICE KITS

………………………………………………………………………………………………………………..147

D

ISPOSAL OF USED MATERIAL

……………………………………………………………………………………………..147

Adjustments and servicing procedures………………………………………………………….148

D

RIVE MOTOR

……………………………………………………………………………………………………………….148

A

IR FILTER

……………………………………………………………………………………………………………………148

O

IL AND OIL FILTER CHANGE

……………………………………………………………………………………………….149

O

IL SEPARATOR CHANGE

…………………………………………………………………………………………………..150

C

OOLERS

…………………………………………………………………………………………………………………….151

B

ELT TENSIONING AND REPLACEMENT

…………………………………………………………………………………….151

S

AFETY VALVES

……………………………………………………………………………………………………………..153

D

RYER MAINTENANCE INSTRUCTIONS

……………………………………………………………………………………..154

Problem solving…………………………………………………………………………………………….156

Technical data……………………………………………………………………………………………….159

11.1

11.2

11.3

11.4

11.5

11.6

R

EADINGS ON DISPLAY

……………………………………………………………………………………………………..159

E

LECTRIC CABLE SIZE

………………………………………………………………………………………………………160

S

ETTINGS FOR OVERLOAD RELAY AND FUSES

……………………………………………………………………………162

D

RYER SWITCHES

……………………………………………………………………………………………………………163

R

EFERENCE CONDITIONS AND LIMITATIONS

………………………………………………………………………………163

C

OMPRESSOR DATA

…………………………………………………………………………………………………………164

2920 7090 51 5

Instruction book

11.7

T

ECHNICAL DATA

E

LEKTRONIKON

®

CONTROLLER

……………………………………………………………………….169

14

15

12

13

Instructions for use……………………………………………………………………………………….171

Guidelines for inspection……………………………………………………………………………….172

Pressure equipment directives………………………………………………………………………173

Declaration of conformity………………………………………………………………………………174

6 2920 7090 51

Instruction book

1 Safety precautions

1.1

Safety icons

Explanation

Danger for life

Warning

Important note

1.2

Safety precautions, general

General precautions

1. The operator must employ safe working practices and observe all related work safety requirements and regulations.

2. If any of the following statements does not comply with the applicable legislation, the stricter of the two shall apply.

3. Installation, operation, maintenance and repair work must only be performed by authorized, trained, specialized personnel.

4. The compressor is not considered capable of producing air of breathing quality. For air of breathing quality, the compressed air must be adequately purified according to the applicable legislation and standards.

5. Before any maintenance, repair work, adjustment or any other non-routine checks, stop the compressor, press the emergency stop button, switch off the voltage and depressurize the compressor. In addition, the power isolating switch must be opened and locked.

6. Never play with compressed air. Do not apply the air to your skin or direct an air stream at people. Never use the air to clean dirt from your clothes. When using the air to clean equipment, do so with extreme caution and wear eye protection.

7. The owner is responsible for maintaining the unit in safe operating condition. Parts and accessories shall be replaced if unsuitable for safe operation.

8. It is not allowed to walk or stand on the roof of the compressor canopy.

1.3

Safety precautions during installation

All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair, even if not expressly stated, will be disclaimed by the manufacturer.

2920 7090 51 7

Instruction book

Precautions during installation

1. The machine must only be lifted using suitable equipment in accordance with the applicable safety regulations. Loose or pivoting parts must be securely fastened before lifting. It is strictly forbidden to dwell or stay in the risk zone under a lifted load. Lifting acceleration and deceleration must be kept within safe limits. Wear a safety helmet when working in the area of overhead or lifting equipment.

2. Place the machine where the ambient air is as cool and clean as possible. If necessary, install a suction duct. Never obstruct the air inlet. Care must be taken to minimize the entry of moisture at the inlet air.

3. Any blanking flanges, plugs, caps and desiccant bags must be removed before connecting the pipes.

4. Air hoses must be of correct size and suitable for the working pressure. Never use frayed, damaged or worn hoses. Distribution pipes and connections must be of the correct size and suitable for the working pressure.

5. The aspirated air must be free of flammable fumes, vapours and particles, e.g. paint solvents, that can lead to internal fire or explosion.

6. Arrange the air intake so that loose clothing worn by people cannot be sucked in.

7. Ensure that the discharge pipe from the compressor to the aftercooler or air net is free to expand under heat and that it is not in contact with or close to flammable materials.

8. No external force may be exerted on the air outlet valve; the connected pipe must be free of strain.

9. If remote control is installed, the machine must bear a clear sign stating: DANGER: This machine is remotely controlled and may start without warning.

The operator has to make sure that the machine is stopped and that the isolating switch is open and locked before any maintenance or repair. As a further safeguard, persons switching on remotely controlled machines shall take adequate precautions to ensure that there is no one checking or working on the machine. To this end, a suitable notice shall be affixed to the start equipment.

10. Air-cooled machines must be installed in such a way that an adequate flow of cooling air is available and that the exhausted air does not recirculate to the compressor air inlet or cooling air inlet.

11. The electrical connections must correspond to the applicable codes. The machines must be earthed and protected against short circuits by fuses in all phases. A lockable power isolating switch must be installed near the compressor.

12. On machines with automatic start/stop system or if the automatic restart function after voltage failure is activated, a sign stating «This machine may start without warning» must be affixed near the instrument panel.

13. In multiple compressor systems, manual valves must be installed to isolate each compressor. Non-return valves (check valves) must not be relied upon for isolating pressure systems.

14. Never remove or tamper with the safety devices, guards or insulation fitted on the machine. Every pressure vessel or auxiliary installed outside the machine to contain air above atmospheric pressure must be protected by a pressure-relieving device or devices as required.

15. Piping or other parts with a temperature in excess of 80˚C (176˚F) and which may be accidentally touched by personnel in normal operation must be guarded or insulated. Other high-temperature piping must be clearly marked.

16. For water-cooled machines, the cooling water system installed outside the machine has to be protected by a safety device with set pressure according to the maximum cooling water inlet pressure.

17. If the ground is not level or can be subject to variable inclination, consult the manufacturer.

Also consult following safety precautions: Safety precautions during operation

and Safety precautions during maintenance .

These precautions apply to machinery processing or consuming air or inert gas.

Processing of any other gas requires additional safety precautions typical to the application which are not included herein.

Some precautions are general and cover several machine types and equipment; hence some statements may not apply to your machine.

8 2920 7090 51

Instruction book

1.4

Safety precautions during operation

All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair, even if not expressly stated, will be disclaimed by the manufacturer.

Precautions during operation

1. Never touch any piping or components of the compressor during operation.

2. Use only the correct type and size of hose end fittings and connections. When blowing through a hose or air line, ensure that the open end is held securely. A free end will whip and may cause injury. Make sure that a hose is fully depressurized before disconnecting it.

3. Persons switching on remotely controlled machines shall take adequate precautions to ensure that there is no one checking or working on the machine. To this end, a suitable notice shall be affixed to the remote start equipment.

4. Never operate the machine when there is a possibility of taking in flammable or toxic fumes, vapours or particles.

5. Never operate the machine below or in excess of its limit ratings.

6. Keep all bodywork doors shut during operation. The doors may be opened for short periods only, e.g. to carry out routine checks. Wear ear protectors when opening a door.

7. People staying in environments or rooms where the sound pressure level reaches or exceeds 90 dB(A) shall wear ear protectors.

8. Periodically check that:

• All guards are in place and securely fastened

• All hoses and/or pipes inside the machine are in good condition, secure and not rubbing

• There are no leaks

• All fasteners are tight

• All electrical leads are secure and in good order

• Safety valves and other pressure-relief devices are not obstructed by dirt or paint

• Air outlet valve and air net, i.e. pipes, couplings, manifolds, valves, hoses, etc. are in good repair, free of wear or abuse

9. If warm cooling air from compressors is used in air heating systems, e.g. to warm up a workroom, take precautions against air pollution and possible contamination of the breathing air.

10. Do not remove any of, or tamper with, the sound-damping material.

11. Never remove or tamper with the safety devices, guards or insulations fitted on the machine. Every pressure vessel or auxiliary installed outside the machine to contain air above atmospheric pressure shall be protected by a pressure-relieving device or devices as required.

Also consult following safety precautions: Safety precautions during installation

and Safety precautions during maintenance .

These precautions apply to machinery processing or consuming air or inert gas.

Processing of any other gas requires additional safety precautions typical to the application which are not included herein.

Some precautions are general and cover several machine types and equipment; hence some statements may not apply to your machine.

2920 7090 51 9

Instruction book

1.5

Safety precautions during maintenance or repair

All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair, even if not expressly stated, will be disclaimed by the manufacturer.

Precautions during maintenance or repair

1. Always use the correct safety equipment (such as safety glasses, gloves, safety shoes, etc.).

2. Use only the correct tools for maintenance and repair work.

3. Use only genuine spare parts.

4. All maintenance work shall only be undertaken when the machine has cooled down.

5. A warning sign bearing a legend such as «work in progress; do not start» shall be attached to the starting equipment.

6. Persons switching on remotely controlled machines shall take adequate precautions to ensure that there is no one checking or working on the machine. To this end, a suitable notice shall be affixed to the remote start equipment.

7. Close the compressor air outlet valve before connecting or disconnecting a pipe.

8. Before removing any pressurized component, effectively isolate the machine from all sources of pressure and relieve the entire system of pressure.

9. Never use flammable solvents or carbon tetrachloride for cleaning parts. Take safety precautions against toxic vapours of cleaning liquids.

10. Scrupulously observe cleanliness during maintenance and repair. Keep dirt away by covering the parts and exposed openings with a clean cloth, paper or tape.

11. Never weld or perform any operation involving heat near the oil system. Oil tanks must be completely purged, e.g. by steam-cleaning, before carrying out such operations. Never weld on, or in any way modify, pressure vessels.

12. Whenever there is an indication or any suspicion that an internal part of a machine is overheated, the machine shall be stopped but no inspection covers shall be opened before sufficient cooling time has elapsed; this to avoid the risk of spontaneous ignition of the oil vapour when air is admitted.

13. Never use a light source with open flame for inspecting the interior of a machine, pressure vessel, etc.

14. Make sure that no tools, loose parts or rags are left in or on the machine.

15. All regulating and safety devices shall be maintained with due care to ensure that they function properly.

They may not be put out of action.

16. Before clearing the machine for use after maintenance or overhaul, check that operating pressures, temperatures and time settings are correct. Check that all control and shut-down devices are fitted and that they function correctly. If removed, check that the coupling guard of the compressor drive shaft has been reinstalled.

17. Every time the separator element is renewed, examine the discharge pipe and the inside of the oil separator vessel for carbon deposits; if excessive, the deposits should be removed.

18. Protect the motor, air filter, electrical and regulating components, etc. to prevent moisture from entering them, e.g. when steam-cleaning.

19. Make sure that all sound-damping material and vibration dampers, e.g. damping material on the bodywork and in the air inlet and outlet systems of the compressor, is in good condition. If damaged, replace it by genuine material from the manufacturer to prevent the sound pressure level from increasing.

20. Never use caustic solvents which can damage materials of the air net, e.g. polycarbonate bowls.

21.

The following safety precautions are stressed when handling refrigerant:

• Never inhale refrigerant vapours. Check that the working area is adequately ventilated; if required, use breathing protection.

10 2920 7090 51

Instruction book

• Always wear special gloves. In case of refrigerant contact with the skin, rinse the skin with water. If liquid refrigerant contacts the skin through clothing, never tear off or remove the latter; flush abundantly with fresh water over the clothing until all refrigerant is flushed away; then seek medical first aid.

Also consult following safety precautions: Safety precautions during installation

and Safety precautions during operation .

These precautions apply to machinery processing or consuming air or inert gas.

Processing of any other gas requires additional safety precautions typical to the application which are not included herein.

Some precautions are general and cover several machine types and equipment; hence some statements may not apply to your machine.

2920 7090 51 11

Instruction book

2 General description

2.1

Introduction

General

GA 5 up to GA 11 are single-stage, oil-injected screw compressors driven by an electric motor. The compressors are air-cooled. The compressors are enclosed in sound insulating bodywork.

Workplace

compressors have no dryer, while

Workplace Full-Feature (FF)

compressors are provided with an integrated air dryer.

The basic version of GA 5 up to GA 11 is equipped with an Elektronikon controller ( see section Elektronikon controller ). The Elektronikon® Graphic controller is available as option (see section

Elektronikon graphic controller ).

The Elektronikon® controller and the emergency stop button are integrated in the door panel of the electric cubicle. An electric cabinet comprising the motor starter is located behind this panel.

Tank-mounted version

The compressors are mounted on an air receiver.

12 2920 7090 51

Instruction book

Ref.

AR

AV

Da

Dc

Dm1

Dm2

ER1

S3

1

Front view, Workplace tank-mounted with Elektronikon® controller

Name

Air receiver

Air outlet valve

Automatic condensate outlet

OSD drain outlet (option)

Manual condensate drain valve

Manual condensate drain valve

Elektronikon® controller

Emergency stop button

Electric cable entry

2920 7090 51 13

Floor-mounted version

The compressors are installed directly on the floor.

Instruction book

14

ER

S3

Dm1

Da

GA 11 Pack, Floor mounted, Front view

Elektronikon® controller

Emergency stop button

Manual condensate drain valve

Automatic condensate outlet

2920 7090 51

Instruction book

Ref.

AF

AV

C

FN

M1

Floor-mounted Workplace Pack compressor, rear view

Name

Air filter

Air outlet valve

Combicooler

Fan motor

Drive motor

2920 7090 51 15

Instruction book

2.2

Air flow

Flow diagrams

For Workplace units

References

B

C

D

Ref.

A

16

For Workplace Full-Feature units

Description

Intake air

Air/oil mixture

Hot compressed air

Oil

2920 7090 51

Instruction book

F

G

Ref.

E

Description

Dry air

Condensate

Dry air (compressors with integrated dryer)

Description

Air drawn through filter (AF) and open inlet valve (IV) into compressor element (E) is compressed.

Compressed air and oil flow into the air receiver/oil separator (OT). The air flows through minimum pressure valve (Vp) to air cooler (Ca).

Minimum pressure valve (Vp) prevents the receiver pressure from dropping below a minimum pressure and includes a check valve which prevents blow-back of compressed air from the net.

On Full-Feature compressors the air flows through air dryer (DR).

Air is discharged through outlet valve (AV).

2.3

Oil system

Flow diagram

Oil system

2920 7090 51 17

Instruction book

B

C

References

A

D

Description

Intake air

Air/oil mixture

Compressed air

Oil

Description

The air/oil mixture coming from the compressor element flows into the oil separator/tank, where most of the oil is separated by centrifugal action. The oil collects in the lower part of air receiver/oil separator (OT) which serves as oil tank. The remaining oil is removed by oil separator (OS). A small pipe returns the separated oil towards the compressor element.

Air pressure forces the oil from oil separator/tank (OT) through oil cooler (Co) and filter (OF) towards compressor element (E).

The system comprises a thermostatic bypass valve (BV). Only when the oil is warm, the valve allows the oil to pass through the oil cooler.

2.4

Cooling system

Flow diagram

Cooling system

18 2920 7090 51

Instruction book

B

C

References

A

D

Description

Intake air

Compressed air/oil

Compressed air

Oil

Description

The cooling system comprises of air cooler (Ca) and oil cooler (Co). The cooling air is generated by a fan

(FN). The fan is set on the shaft of the motor.

2.5

Condensate system

Condensate drains

Condensate drains on a floor-mounted version

Condensate drains on a tank-mounted Full-Feature version

Pack versions are equipped with a condensate trap in the air outlet system. The trap is equipped with a valve for automatic draining during operation and is connected to the automatic drain outlet (Da) and to a manually operated valve (Dm1) for draining after stopping the compressor.

Tank-mounted compressors are also provided with a manual condensate drain valve (Dm2) for draining the condensate trapped in the receiver.

Full-Feature versions are equipped with an electronic water drain for automatic draining of the condensate during operation. The electronic drain is connected to automatic drain outlet (Da) and to a manually operated valve (Dm1) for draining after stopping the compressor.

2920 7090 51 19

Instruction book

2.6

Regulating system

Flow diagram

Unloading

If the air consumption is less than the air output of the compressor, the net pressure increases. When the net pressure reaches the unloading pressure, solenoid valve (Y1) is de-energised.

• The control pressure present in the chambers of loading plunger (LP) and unloading valve (UV) is vented to atmosphere via solenoid valve (Y1).

• Loading plunger (LP) moves upwards and causes inlet valve (IV) to close the air inlet opening.

• Unloading valve (UV) is opened by the pressure in the oil separator vessel. The pressure from the oil separator vessel is released into atmosphere through the unloader (UA).

• The pressure in the oil separator vessel stabilises at low value. A reduced amount of air is compressed to guarantee a minimal pressure, required for lubrication during unloaded operation.

Air output is stopped (0%), the compressor runs unloaded.

Loading

When the net pressure decreases to the loading pressure, solenoid valve (Y1) is energised.

• Control pressure is fed from the oil separator vessel via solenoid valve (Y1) to loading plunger (LP) and unloading valve (UV).

• Unloading valve (UV) closes the air blow-off opening. Loading plunger (LP) moves downwards and causes inlet valve (IV) to open fully.

Air delivery is resumed (100%), the compressor runs loaded.

2.7

Electrical system

General

Also consult sections Electrical diagrams

and Electrical connections

.

The electrical system comprises following components:

20 2920 7090 51

Instruction book

KD

KY

KL

T1

PE

Reference

F1

F2-F3

FM

Electric cabinet

Description

Fuses

Fuses

Overload relay, compressor motor

Delta contactor

Star contactor

Line contactor

Transformer

Earth terminal

2.8

Electrical diagrams

The service diagram and the explanatory designations below are given as typical example only. Some of the texts may not be applicable to a specific case.

The applicable service diagram is situated in the electric cubicle of the compressor.

2920 7090 51 21

Instruction book

22

Designations

Service diagram

2920 7090 51

Instruction book

Reference

PT20

TT11

TT90

TT91

Y1

Reference

M1

M2

T1

KA

S1′

S2′

S3

S3′

Reference

E1

F1-F11

FM1

KMD

KL

KY

KD

I

Reference

0

K01

K02

K03

K04

K05

K06

Reference

A1

B1/B2

KPH

K34/K35

Sensors / solenoid valves / electronic water drain

Pressure sensor, air outlet

Temperature sensor, element outlet

Temperature sensor, dew-point (Full Feature)

Temperature sensor, ambient (Full Feature)

Loading solenoid valve

Motors

Compressor motor

Fan motor, cooler

Electric cabinet

Compressor control module

Fuses

Overload relay, compressor motor

Contactor for dryer (Full-Feature)

Line contactor

Star contactor

Delta contactor

Transformer

Auxiliary relay for heaters and auxiliary fan

Remote Start/programmed stop

Remote Load/unload

Emergency stop

Remote emergency stop

Control module

Start button

Stop button

Blocking relay

Auxiliary relay, star contactor

Auxiliary relay, delta contactor

Auxiliary relay, loading/unloading

Auxiliary relay, general shutdown

Auxiliary relay, dryer

Optional equipment

Dryer (Full-Feature)

Electronic Water Drain (EWD)

Phase sequence relay

Thermistor relay

2920 7090 51 23

Reference

R1/K34

R96

KE

S10

Y2

Optional equipment

Drive motor thermistor protection, shut-down

Anti-condensation heaters

Auxiliary relay, load/unload signal for ES100

Main power isolating switch

Solenoid valve for modulating control

2.9

Air dryer

Flow diagram

Instruction book

24

4

5

2

3

Reference

AI

AO

1

Air dryer

Name

Air inlet

Air outlet

Air/air heat exchanger

Air/refrigerant heat exchanger/evaporator

Condensate separator

Automatic drain / condensate outlet

Refrigerant compressor

2920 7090 51

Instruction book

7

8

Reference

6

9

10

11

Name

Refrigerant condenser

Liquid refrigerant dryer/filter

Capillary

Hot gas by-pass valve

Condenser cooling fan

Pressure switch, fan control

Compressed air circuit

Compressed air enters heat exchanger (1) and is cooled by the outgoing, cold, dried air. Water in the incoming air starts to condense. The air then flows through heat exchanger/evaporator (2), where the refrigerant evaporates, causing the air to be cooled further to close to the evaporating temperature of the refrigerant. More water in the air condenses. The cold air then flows through separator (3) where all the condensate is separated from the air. The condensate is automatically drained through outlet (4).

The cold, dried air flows through heat exchanger (1) where it is warmed up by the incoming air.

Refrigerant circuit

Compressor (5) delivers hot, high-pressure refrigerant gas which flows through condenser (6) where most of the refrigerant condenses.

The refrigerant enters evaporator (2) where it withdraws heat from the compressed air by further evaporation at constant pressure. The heated refrigerant leaves the evaporator and is sucked in by the compressor (5).

By-pass valve (9) regulates the refrigerant flow. Fan (10) is switched on or off by switch (11) depending on the loading degree of the refrigerant circuit.

The refrigerant compressor motor has a built-in thermic protection. If the motor stops after tripping of the thermic protection, it may take up to 2 hours for the motor windings to cool down and before the motor can restart.

2920 7090 51 25

Instruction book

3 Elektronikon® controller

3.1

Elektronikon

®

regulator

Control panel

Introduction

In general, the Elektronikon

®

regulator has following functions:

• Controlling the compressor

• Protecting the compressor

• Monitoring components subject to service

• Automatic restart after voltage failure (made inactive)

Automatic control of the compressor

The regulator maintains the net pressure between programmable limits by automatically loading and unloading the compressor. A number of programmable settings, e.g. the unloading and loading pressures, the minimum stop time and the maximum number of motor starts are taken into account.

The regulator stops the compressor whenever possible to reduce the power consumption and restarts it automatically when the net pressure decreases. If the expected unloading period is to short, the compressor is kept running to prevent too short stand-still periods.

Protecting the compressor

Shut-down

If the compressor element outlet temperature exceeds the programmed shut-down level, the compressor will be stopped. This will be indicated on the display of the regulator. The compressor will also be stopped in case of overload of the drive motor.

Air-cooled compressors will also be stopped in the event of overload of the fan motor.

Before remedying, consult the

Safety precautions.

Shut-down warning

A shut-down warning level is a programmable level below the shut-down level.

26 2920 7090 51

Instruction book

If one of the measurements exceeds the programmed shut-down warning level, this will also be indicated to warn the operator before the shut-down level is reached.

Service warning

If the service timer exceeds a programmed value, this will be indicated on the display to warn the operator to carry out some service actions.

Automatic restart after voltage failure

The regulator has a built-in function to automatically restart the compressor when the voltage is restored after voltage failure. This function is deactivated in compressors leaving the factory. If desired, the function can be activated. Consult the Atlas Copco Customer Centre.

If activated, and if the regulator was in the automatic operation mode, the compressor will automatically restart when the supply voltage to the module is restored!

3.2

Control panel

Detailed description

Control panel of the Elektronikon with standard display

6

7

4

5

8

Reference

1

2

3

Designation

Display

Automatic operation symbol

LED, Automatic operation

Warning symbol

LED, Warning

Voltage symbol

LED, Voltage on

Service symbol

Function

Shows icons and operating conditions.

Indicates that the regulator is automatically controlling the compressor: the compressor is loaded, unloaded, stopped and restarted depending on the air consumption and the limitations programmed in the regulator.

Is lit if a warning condition exists.

Indicates that the voltage is switched on.

2920 7090 51 27

Instruction book

12

13

14

Reference

9

10

11

Designation

LED, Service

Start button

Stop button

Scroll buttons

Enter button

Escape button

Function

Is lit when service is needed.

This button starts the compressor. Automatic operation

LED (3) lights up. The Elektronikon is operative.

This button is used to stop the compressor. Automatic operation LED (3) goes out.

Use these buttons to scroll trough the menu .

Use this button to confirm the last action

Use this button to go to previous screen or to end the current action.

3.3

Icons used on the display

Function

Compressor status

Icon Description

When the compressor is stopped, the icon stands still.

When the compressor is running, the icon is rotating.

Motor stopped

Running unloaded

Running loaded

Machine control mode Remote start / stop

LAN control

Automatic restart after voltage failure is active Automatic restart after voltage failure

Timer

Active protection functions

Service

Emergency stop

Service required

28 2920 7090 51

2920 7090 51

Instruction book

Function

Units

Icon Description

Pressure unit (Mega Pascal)

Pressure unit (pounds per square inch)

Pressure unit (bar)

Temperature unit

Temperature unit

Hours (always shown together with seconds)

Percent

The value shown must be multiplied by 10 to get the actual value

The value shown must be multiplied by 100 to get the actual value

The value shown must be multiplied by 1000 to get the actual value

Motor (overload)

Element outlet temperature.

Filter

Drain

Energy saving (dryer)

Ambient temperature

29

Instruction book

Function Icon Description

Dewpoint temperature

3.4

Main screen

When the voltage is switched on, the first screen is a test screen. The next screen is the Main screen, shown automatically.

The Main screen shows:

• The compressor status by means of pictographs

• The air outlet pressure

Always consult Atlas Copco if the pressure on the display is preceded by a «t».

3.5

Shut-down warning

Description

A shut-down warning will appear in the event of:

• Too high a temperature at the outlet of the compressor element

• Too high a dewpoint temperature (Full-Feature compressors)

Compressor element outlet temperature

• If the outlet temperature of the compressor element exceeds the shut-down warning level (factory set at

110 ˚C / 230 ˚F), warning LED (5) starts blinking.

30 2920 7090 51

Instruction book

• Press Scroll down button (12). The screen shows the temperature at the compressor element outlet:

The screen shows that the temperature at the element outlet is 122 °C

It remains possible to scroll through other screens, using the Scroll buttons up and down (12) to check the actual status of other parameters. Press button (11) to stop the compressor and wait until the compressor has stopped. Switch off the voltage, inspect the compressor and remedy. The warning message will disappear as soon if the warning condition disappears.

Dewpoint temperature

On compressors with integrated dryer, alarm LED (5) will light up and the related pictograph will appear flashing if the dewpoint temperature exceeds the warning level (programmable).

The related pictograph

Main screen with the dewpoint temperature warning

will appear flashing

Press the Scroll button (12) until the actual dewpoint temperature appears.

2920 7090 51 31

Instruction book

Warning screen, dewpoint temperature

The screen shows that the dewpoint temperature is 9˚C.

• It remains possible to scroll through other screens (using Scroll buttons 12) to check the actual status of other parameters.

• Press button (11) to stop the compressor and wait until the compressor has stopped.

• Switch off the voltage, inspect the compressor and remedy.

• The warning message will disappear as soon as the warning condition disappears.

3.6

Shut-down

Description

The compressor will be shut down:

• In case the temperature at the outlet of the compressor element exceeds the shut-down level

• In case of error of the outlet pressure sensor

• In case of overload of the drive motor

• In case of overload of the fan motor on air-cooled compressors

Compressor element outlet temperature

• If the outlet temperature of the compressor element exceeds the shut-down level (factory setting 120 ˚C /

248 ˚F, programmable) the compressor will be shut-down, alarm LED (5) will flash, automatic operation

LED (3) will go out and the following screen will appear:

32

Main screen with shut-down indication, element outlet temperature

The related pictograph will appear flashing.

2920 7090 51

Instruction book

• Press Scroll buttons (12) until the actual compressor element temperature appears.

Shut-down screen, element outlet temperature

The screen shows that the temperature at the outlet of the compressor element is 122 ˚C.

• Switch off the voltage and remedy the trouble.

• After remedying and when the shut-down condition has disappeared, switch on the voltage and restart the compressor.

Motor overload

• In the event of motor overload, the compressor will be shut-down, alarm LED (5) will flash, automatic operation LED (3) will go out and the following screen will appear:

Main screen with shut-down indication, motor overload

• Switch off the voltage and remedy the trouble.

• After remedying and when the shut-down condition has disappeared, switch on the voltage and restart the compressor.

3.7

Service warning

Description

A service warning will appear when the service timer has reached the programmed time interval.

2920 7090 51 33

Instruction book

• If the service timer exceeds the programmed time interval, alarm LED (5) will light up.

• Press Scroll buttons (12) to scroll to <d.6> and the service symbol is shown. Press button (13): the actual reading of the service timer appears and is shown in <hrs> or <x1000 hrs> (if the service timer value is higher than 9999).

Example of service timer screen

The screen shows that the reading of the service timer is 4002.

• Press Scroll button (12) to scroll to <d.1> and the running hours symbol is shown. Press button (13): the actual reading of the service timer appears and is shown in <hrs> or <x1000 hrs> (if the service timer value is higher than 9999).

34

Example of running hours screen

• Stop the compressor, switch off the voltage and carry out the required service actions. See section

Preventive Maintenance.

• The longer interval service actions must also include the shorter interval actions.

In the example above, carry out all service operations belonging to the 8000 running hours interval as well as those belonging to the 4000 running hours interval.

• If using mineral oil instead of Atlas Copco Roto-Inject Fluid, the service timer has to be decreased. See section Preventive maintenance schedule.

2920 7090 51

Instruction book

• After servicing, reset the service timer. See section Calling up/resetting the service timer

3.8

Scrolling through all screens

Control panel

Control panel

Scroll buttons (12) can be used to scroll through all screens. The screens are divided into register screens, measured data screens, digital input screens (numbered as <d.in>, <d.1>, …), parameter screens (numbered as <P.01>, <P.02>, …), protections screens (numbered as <Pr.01>,…) and test screens (numbered as <t.01>,…).

During scrolling, the numbers of the screens appear consecutively. For most screens, the unit of measurement and the related pictograph are shown together with the screen number.

Example

The screen shows the screen number <d.1>, the unit used <hrs> and the related symbol for running hours.

Press Enter key (13) to call up the actual running hours.

Overview of the screens

Digital input screens

<d.in>

<d.1>

<d.2>

<d.3>

Designation

Digital input status

Running hours (hrs or x 1000 hrs)

Motor starts (x 1 or x 1000)

Module hours (hrs or x 1000 hrs)

Related topic

See section

Calling-up running hours

See section

Calling up motor starts

See section

Calling up module hours

2920 7090 51 35

36

Instruction book

<P.10>

<P.11>

<P.12>

<P.13>

<P.14>

Digital input screens

<d.4>

<d.5>

<d.6>

<d.7>

Parameter screens

<P.01>

<P.02>

<P.03>

<P.04>

<P.05>

<P.06>

<P.07>

<P.08>

<P.09>

Protections screens

<Pr.01>

<Pr.02>

<Pr.03>

Designation

Loading hours (hrs or x1000 hrs)

Load relay (x1 or x 1000)

Service timer reading (hrs or x 1000 hrs)

Actual program version

Related topic

See section

Calling up loading hours

See section Calling up Calling up load relay

See section

Calling up/resetting the service timer

Designation Related topic

Selection between local, remote or LAN control

Setting a node ID for LAN control and the channels for Mk 4 and Mk 5

See section

Selection between Local

Remote and LAN control

See section

Calling up/modifying CAN address control

Settings for IP, gateway and Subnet mask See section

Calling up/modifying IP,

Gateway and Subnetmask

Pressure band settings See section

Calling up/modifying pressure band settings

Setting a pressure band selection See section

Modifying pressure band selection

Modifying a service timer

Setting of unit for temperature

Setting of unit for pressure

See section

Calling up/modifying service timer settings

See section

Calling up/modifying unit of temperature

See section

Calling up/modifying unit of pressure

See section

Activating automatic restart

Selection for function: Automatic restart after voltage failure (active or not, only for Atlas

Copco)

Selection between Y-D or DOL starting

Setting of load delay time

Setting of minimum stop time

See section

Selection between Y-D or DOL starting

See section Calling up/modifying load delay time

See section

Calling up/Modifying minimum stop time

Setting a password

Remote pressure sensing

See section

Activating password protection

See section

Activate Load/Unload remote sensing

Designation

Protections screens

Related topic

See section

Calling up/modifying protection settings

2920 7090 51

Instruction book

Test screens

<t.01>

<t.02>

<t.03>

Designation

Display test

Safety valve test

Production test

Menu flow

Related topic

See sections Test screens

See sections Test screens

See sections Test screens

2920 7090 51

Simplified menu flow

37

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Ref.

(1)

(2)

(3)

(4)

(12)

(13)

(14)

(15)

Description

Compressor outlet pressure

Compressor outlet temperature

Dewpoint temperature

Digital input status

Running hours

Motor starts

Module hours

Loading hours

Load relay

Service timer reading

Actual program version

LAN selection

Settings node ID

IP settings

Pressure band selection

(20)

(21)

(22)

(23)

(24)

(25)

(26)

Ref.

(16)

(17)

(18)

(19)

(27)

(28)

(29)

Description

Pressure band setting

Service timer settings

Temperature unit

Unit pressure

Auto restart

Selection Y-D/DOL

Load delay time

Minimum stop time

Password settings

Remote pressure sensing

Protections

Display test

Safety valve test

Production test

3.9

Calling up outlet and dewpoint temperatures

Control panel

Instruction book

Starting from the Main screen:

38

• Press Scroll button (12). The outlet temperature will be shown:

2920 7090 51

Instruction book

The screen shows that the outlet temperature is 82 ˚C.

• For Full-Feature compressors:

Press Scroll button (12). The dewpoint temperature will be shown:

The screen shows that the dewpoint temperature is 3 ˚C.

• Press Scroll button (12) to scroll downwards or upwards through the screens.

3.10 Calling up running hours

Control panel

Starting from the Main screen:

• Press Scroll button (12) until <d.1> is shown and then press Enter button (13):

2920 7090 51 39

Instruction book

The screen shows the unit used (x1000 hrs) and the value (11.25): the running hours of the compressor are

11250 hours.

3.11 Calling up motor starts

Control panel

40

Starting from the Main screen:

• Press Scroll button (12) until <d.2> is shown and then press Enter button (13):

This screen shows the number of motor starts (x 1 or — if <x1000> lights up — x 1000). In the above example, the number of motor starts is 10100.

2920 7090 51

Instruction book

3.12 Calling up module hours

Control panel

Starting from the Main screen:

• Press Scroll button (12) until <d.3> is shown and then press Enter button (13):

In the example shown, the screen shows the unit used (hrs) and the value (5000): the regulator module has been in service during 5000 hours.

3.13 Calling up loading hours

Starting from the Main screen:

• Press Scroll button (12) until <d.4> is shown and then press Enter button (13):

The screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1755>: the compressor has been running loaded during 1755 hours.

3.14 Calling up load relay

Starting from the Main screen:

2920 7090 51 41

Instruction book

• Press Scroll button (12) until <d.5> is shown and then press Enter button (13):

This screen shows the number of unload to load actions (x 1 or — if <x1000> lights up — x 1000). In the above example, the number of unload to load actions is 10100.

3.15 Calling up/resetting the service timer

Calling up the service timer

Starting from the Main screen:

42

• Press Scroll button (12) until <d.6> is shown and then press Enter button (13):

2920 7090 51

Instruction book

This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the compressor has run 1191 hours since the previous service.

Resetting the service timer

After servicing, see section

Service warning , the timer has to be reset:

• Scroll to register screen <d.6> and press Enter button (13).

• The reading (e.g. 4000) will appear.

• Press Enter button (13) and — if a password is set — enter the password.

The icon will flash (indicating that resetting is possible).

• Press Enter button (13) to reset the timer to <0.000> or press the Escape button (14) to cancel the operation.

3.16 Selection between local, remote or LAN control

Starting from the Main screen:

• Press Scroll button (12) until <P.01> is shown and then press Enter button (13). The actually used control mode is shown: <LOC> for local control, <rE> for remote control or <LAn> for LAN control.

• Press Enter button (13) and if necessary enter the password. The actually used control mode is blinking.

Use Scroll button (12) to change the control mode.

• Press Enter button (13) to program the new starting mode or press Escape button (14) to cancel.

3.17 Calling up/modifying CAN address control

Calling up

Starting from the main screen,

Press the Scroll button (12) until <P.02> is shown and then press Enter button (13).

2920 7090 51 43

Instruction book

If necessary enter the password. The next screen shows that the function is “ON or OFF” Press the Enter button (13) to change this mode Use the Scroll buttons (12) to select ON or OFF.

When this function is ON, use the Scroll buttons up or down (12) to see the node ID.

If desired the user can change this ID. Press the Enter button (13): the node ID value starts blinking. Use the

Scroll buttons (12) to change the node ID. Press the Enter button (13) to program the new node ID or press the Escape button (14) to leave this screen or to cancel this operation.

Modifying the Node ID

The Node ID can be changed; use a value between 1 and 31. When the function is ON, the parameters cannot be modified. Change the function to OFF to change the node ID.

44

It is also possible to change the channels. The controller has 4 channels. When changing the channels, the controller can act as a Mk IV controller. To set the channels, go to the screen where the node ID is visible.

Press the Scroll button down (12). The following screen appears:

2920 7090 51

Instruction book

Press the Enter button (13) to modify the setting. The utmost left value will blink. Change this value by using the Scroll buttons (12). Press the Enter button (13) to confirm. Change the other values in the same way, as required.

After modifying the settings, the screen may look as follows:

3.18 Calling up/modifying IP, Gateway and Subnetmask

Calling up

Starting from the Main screen:

Press the Scroll button (12) until <P.03> is shown and then press Enter button (13).

The next screen shows either OFF or ON. If ON, press the Enter button (13) to modify it to OFF. Use the

Scroll buttons Up or Down (12) to scroll between the items in this list (<IP> for IP address, <SUB> for

Subnetmask or <GATE> for Gateway):

2920 7090 51 45

Instruction book

Modification

Press the Enter button (13) and if necessary enter the password. The first digits are blinking. Use the Scroll buttons Up or Down (12) to modify the settings and press Enter (13) to confirm. Modify the next digits the same way. The standard IP address is set as 192.168.100.100.

46 2920 7090 51

Instruction book

3.19 Calling up/modifying pressure band settings

Calling up the settings

Starting from the Main screen:

• Press Scroll button (12) until <P.04> is shown and then press Enter button (13). Pressure band 1 (<Pb.1>) is shown on the display. Button (12) can be used to scroll to pressure band 2 (<Pb.2>).

• Press Enter button (13) on the desired pressure band. The load level of the selected pressure band appears.

Button (12) can be used to scroll to the unload level.

2920 7090 51 47

Instruction book

Loading pressure

Unloading pressure

• Press Enter button (13) to modify the load level (value starts blinking). A password may be required. Use

Scroll buttons (12) to change the loading pressure.

• Press Enter button (13) to program the new values or press the Escape button (14) to cancel.

3.20 Modifying the pressure band selection

Control panel

48 2920 7090 51

Instruction book

Starting from the Main screen:

• Press Scroll button (12) until <P.05> is shown and then press Enter button (13). The active pressure band

1 (<Pb.1>) is shown on the display.

• Press Enter button (13) to modify the pressure band selection (a password may be required). The active pressure band <Pb.1> starts blinking.

• Press button (12) to modify the active pressure band. Press Enter button (13) to confirm or the Escape button (14) to cancel.

3.21 Calling up/modifying service timer settings

Control panel

Starting from the Main screen:

• Press Scroll button (12) until <P.06> is shown and then press Enter button (13): the setting of the service timer is shown in <hrs> (hours) or <x1000 hrs> (hours x 1000). Example: <4000 hrs> means the timer is set at 4000 running hours.

• Press Enter button (13) to modify this value (a password may be required): the value blinks. Use the Scroll buttons (12) to modify the setting.

• Press Enter button (13) to program the new value.

3.22 Calling up/modifying the unit of temperature

Control panel

Starting from the Main screen:

• Press Scroll button (12) until <P.07> is shown and then press Enter button (13). The actually used unit is shown. Possible settings are <˚C> and <˚F>.

• Press Enter button (13) (unit blinks) and use the Scroll buttons (12) to select another unit of temperature.

• Press Enter button (13) to program the new unit or press Escape button (14) to return to the parameter screen without changes.

2920 7090 51 49

3.23 Calling up/modifying unit of pressure

Control panel

Instruction book

Starting from the Main screen:

• Press Scroll button (12) until <P.08> and the possible settings are shown (<Mpa>, <psi>, and <bar>).

Press Enter button (13) and the actually used unit is shown.

• Press Enter button (13) (unit starts blinking) and use the Scroll buttons (12) to select another unit of pressure.

• Press Enter button (13) to program the new unit of pressure. Press the escape button (14) to return to the parameter screens.

3.24 Activating automatic restart after voltage failure

Description

This parameter, accessible in screen <P.09>, can only be modified after entering a code. Consult Atlas Copco if this function is to be activated.

3.25 Selection between Y-D or DOL starting

Control panel

Starting from the Main screen:

• Press Scroll button (12) until <P.10> and the motor pictograph is shown and then press Enter button (13).

The actually used starting mode is shown: <Y-D> (star-delta) or <doL> (Direct-On Line).

50 2920 7090 51

Instruction book

• This parameter can only be modified after entering a code. Consult Atlas Copco if the parameter is to be changed.

3.26 Calling up modifying load delay time

Control panel

Starting from the Main screen:

• Press Scroll button (12) until <P.11> and the compressor load pictograph is shown and press the Enter button (13):

• This screen shows the load delay time 10 and the unit <s> seconds. To modify this value press the Enter button (13) (a password may be required).

• The value starts blinking and Scroll buttons (12) can be used to modify the value.

• Press the Enter button (13) to program the new value.

The minimum and maximum value depends on the parameters.

3.27 Calling up modifying minimum stop time

Starting from the Main screen:

2920 7090 51 51

Instruction book

• Press the Scroll button (12) until <P.12> and the motor pictograph is shown and press the Enter button

(13):

• This screen shows the minimum stop time (20) and the unit <s> (seconds).

• To modify this value press the Enter button (13). The value starts blinking and Scroll buttons (12) can be used to modify this value.

• Press Enter button (13) to program the new value.

The minimum and maximum values depend on the parameters.

3.28 Activating password protection

Important settings such as the setting of the service timer, pressure band setting, control mode settings,… can be protected by a password.

Starting from the Main screen:

• Press Scroll buttons (12) until <P.13> is shown and press Enter button (13):

• Password (<PASS>) appears on the screen. Press the Enter button (13).

• The screen shows the password status (ON (<On>) or OFF (<OFF>). Press Enter button (13) to modify.

• Change the value with Scroll buttons (12).

• Select <On> and press Enter button (13).

• Enter the new password and press Enter button (13) to confirm.

• Enter the password again and press Enter button (13) to confirm.

• <On> appears on the display. Press reset key to return to the parameter screen.

Lost passwords can not be recovered. Save the password carefully.

3.29 Activate load/unload remote pressure sensing

Starting from the Main screen:

• Press the Scroll button (12) until <P.14> appears

.

52 2920 7090 51

Instruction book

• Press the Enter button (13).

• The function of this screen is to activate the remote load/unload relay. To be able to activate this remote

Load/Unload functionality, a physical digital input with function Load/Unload is required.

Once this parameter is activated, the physical digital input can be used to switch the compressor between

Load and Unload.

3.30 Calling up/modifying protection settings

Available protections

A number of protection settings are provided. The protection screens are labelled <Pr.>. The pictograph shown with the protection screen indicates the purpose of the protection.

Possible combinations are <Pr.> followed by a number and one of the next pictographs:

Pictograph Designation

<Pr.> shown with the pressure pictograph shows the pressure protections.

<Pr.> shown with the element outlet temperature pictograph shows the element outlet temperature protections.

<Pr.> shown with the dewpoint temperature pictograph shows the dewpoint temperature protections.

<Pr.> shown with the ambient temperature pictograph shows the ambient temperature protections.

Following protection settings are available:

2920 7090 51 53

• A low warning level, shown on the display as <AL-L>.

• A high warning level, shown on the display as <AL-H>.

• A low shut-down level, shown on the display as <Sd-L>.

• A high shut-down level, shown on the display as <Sd-H>.

• Service level shown on the display as <SE-L>.

• Service level shown on the display as <SE-H>.

Example of protection screens

Instruction book

Changing the settings

Starting from the Main screen (the example given describes the protection of the element outlet temperatures):

Press Scroll buttons (12) until <Pr.> followed by a number and the element outlet temperature pictograph is shown and press Enter button (13):

• The warning level for the high temperature warning level <AL-H> and the high temperature shut-down level <Sd-H> become visible. Use Scroll keys (12) to move between the warning level (<AL>) and the shut-down level (<Sd>), press the Enter button (13) to modify the value.

• An optional password may be required, the value starts blinking and Scroll buttons (12) can be used to modify the value.

• Press the Enter button (13) to program the new value.

Programmable settings can only be modified within allowed limits.

54 2920 7090 51

Instruction book

3.31 Test screens

Display test

Starting from the Main screen:

• Press Scroll buttons (12) until <t.01> is shown and then press Enter button (13).

Safety valve test

In the test screen <t.02> a safety valve test is provided. The safety valves can only be tested after entering a code. Consult Atlas Copco if the safety valves are to be tested.

Production test

Test screen <t.03> is only intended for production test. If the Main screen shows following screen, the controller is in production test mode:

How to solve?

Use the Scroll buttons (12) and scroll to menu <t.03>.

The screen shows:

Press the Enter button (13): the text starts blinking. Press enter again and the menu disappears.

2920 7090 51 55

Instruction book

3.32 Web server

All Elektronikon controllers have a built-in web server that allows direct connection to a PC via a local area network (LAN). This allows to consult certain data and settings via the PC instead of via the display of the controller.

Getting started

Make sure you are logged in as administrator.

• Use the internal network card from your computer or an USB to LAN adapter (see picture below).

USB to LAN adapter

• Use an UTP cable (CAT 5e) to connect to the controller (see picture below).

Configuration of the network card

• Go to My Network places (1).

56 2920 7090 51

Instruction book

• Click on View Network connections (1).

• Select the Local Area connection (1), which is connected to the controller.

• Click with the right button and select properties (1).

2920 7090 51 57

Instruction book

• Use the checkbox Internet Protocol (TCP/IP) (1) (see picture). To avoid conflicts, de-select other properties if they are selected. After selecting TCP/IP, click on the Properties button (2) to change the settings.

• Use the following settings:

• IP Address 192.168.100.200

• Subnetmask 255.255.255.0

Click OK and close network connections.

Configuration of the web server

Configure the web interface

The internal web server is designed and tested for Microsoft® Internet Explorer 6, 7 and

8. Other web browsers like Opera and Firefox do not support this internal web server.

When using Opera or Firefox, a redirect page opens. Click on the hyperlink to connect to the download server from Microsoft® to download the latest version of Internet Explorer, and install this software.

• When using Internet Explorer:

Open Internet Explorer and click on Tools — Internet options (2).

58 2920 7090 51

Instruction book

• Click on the Connections tab (1) and then click on the LAN settings button (2).

• In the Proxy server Group box, click on the Advanced button (1).

2920 7090 51 59

Instruction book

• In the Exceptions Group box, enter the IP address of your controller. Multiple IP addresses can be given but they must be separated with semicolons (;).

Example: Suppose that you already added two IP addresses (192.168.100.1 and 192.168.100.2). Now you add 192.168.100.100 and separate the 3 IP addresses by putting semicolons between them (1) (see picture).

Click OK (2) to close the window.

60

Viewing the controller data

• Open your browser and type the IP address of the controller you want to view in your browser (in this example http://192.168.100.100). The interface opens:

2920 7090 51

Instruction book

Navigation and options

• The banner shows the compressor type and the language selector. In this example, three languages are installed on the controller.

• On the left site of the interface you can find the navigation menu (see picture below).

If a license for ESi is foreseen, the menu contains 3 buttons.

• Compressor: shows all compressor settings.

• Es: shows the ESi status (if a license is provided).

• Preferences: allows to change temperature and pressure unit.

2920 7090 51 61

Instruction book

Compressor settings

All compressor settings can be hidden or shown. Put a mark for each setting. Only the machine status is fixed and can not be removed from the main screen.

Analog inputs

(The units of measure can be changed in the preference button from the navigation menu).

Counters

Counters give an overview of all actual counters from controller and compressor.

Info status

Machine status is always shown on the web interface.

Digital inputs

Gives an overview of all Digital inputs and status.

62 2920 7090 51

Instruction book

Digital outputs

Shows a list of all digital outputs and their status.

Special protections

Give an overview of all special protections of the compressor.

Service plan

Shows all levels of the service plan and status. This screen only shows the running hours. It is also possible to show the actual status of the service interval.

ES screen controller

If a ESi license is provided, the button ES is shown in the navigation menu. At the left all compressors in the

ES and at the right the ES status is shown.

2920 7090 51 63

Instruction book

A possible ESi screen

3.33 Programmable settings

Parameters: unloading/loading pressures for compressors without built-in refrigeration dryer

Minimum setting

Factory setting

Maximum setting

Unloading pressures

Unloading pressure (7.5 bar compressors)

Unloading pressure (7.5 bar compressors)

Unloading pressure (8.5 bar compressors)

Unloading pressure (8.5 bar compressors)

Unloading pressure (10 bar compressors)

Unloading pressure (10 bar compressors)

Unloading pressure (13 bar compressors)

Unloading pressure (13 bar compressors)

Unloading pressure (100 psi compressors)

Unloading pressure (100 psi compressors)

Unloading pressure (125 psi compressors)

Unloading pressure (125 psi compressors)

Unloading pressure (150 psi compressors)

Unloading pressure (150 psi compressors)

Unloading pressure (175 psi compressors)

Unloading pressure (175 psi compressors)

Loading pressures

Loading pressure (7.5 bar compressors)

Loading pressure (7.5 bar compressors)

Loading pressure (8.5 bar compressors)

Loading pressure (8.5 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (13 bar compressors) bar(e) psig bar(e) psig bar(e) psig bar(e)

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80 bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig

5.4

78

5.4

78

5.4

78

5.4

6.9

100

8.6

125

10.3

150

12

175

7

101.5

8

116

9.5

137.8

12.5

181.3

6.4

92.8

7.4

107.3

8.9

129.1

11.9

7.4

107.3

8.4

121.8

9.9

143.6

12.9

7.4

107.3

9.1

132

10.8

156.6

12.5

181.2

7.5

108.8

8.5

123.5

10

145.0

13

188.6

64 2920 7090 51

Instruction book

Loading pressure (13 bar compressors)

Loading pressure (100 psi compressors)

Loading pressure (100 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (175 psi compressors)

Loading pressure (175 psi compressors) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig

78

5.4

78

5.4

78

Minimum setting

78

5.4

78

5.4

Factory setting

172.6

6.3

91.4

8

116

9.7

140.7

11.4

165.3

Parameters: unloading/loading pressures for compressors with built-in refrigeration dryer

Minimum setting

Factory setting

Maximum setting

Unloading pressures

Unloading pressure (7.5 bar compressors)

Unloading pressure (7.5 bar compressors)

Unloading pressure (8.5 bar compressors)

Unloading pressure (8.5 bar compressors)

Unloading pressure (10 bar compressors)

Unloading pressure (10 bar compressors)

Unloading pressure (13 bar compressors)

Unloading pressure (13 bar compressors)

Unloading pressure (100 psi compressors)

Unloading pressure (100 psi compressors)

Unloading pressure (125 psi compressors)

Unloading pressure (125 psi compressors)

Unloading pressure (150 psi compressors)

Unloading pressure (150 psi compressors)

Unloading pressure (175 psi compressors)

Unloading pressure (175 psi compressors)

Loading pressures

Loading pressure (7.5 bar compressors)

Loading pressure (7.5 bar compressors)

Loading pressure (8.5 bar compressors)

Loading pressure (8.5 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (13 bar compressors)

Loading pressure (13 bar compressors)

Loading pressure (100 psi compressors) bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig bar(e) bar(e) psig

5.4

78

5.4

78

5.4

78

5.4

78

5.4

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

5.5

80

6.4

92.8

7.4

107

8.9

129.1

11.9

172.6

6.3

181.3

6.9

100

8.6

125

10.3

150

7

101.5

8

116

9.5

137.8

12.5

12

175

7.1

103

8.2

119

9.6

139.2

12.6

182.8

7

184.2

7.1

103

8.8

127.6

10.5

152.3

7.2

104.4

8.3

120

9.7

140.7

12.7

12.2

177

2920 7090 51

Maximum setting

187.1

7.3

105.9

9

130.5

10.7

155.2

12.4

179.8

65

Instruction book

Loading pressure (100 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (175 psi compressors)

Loading pressure (175 psi compressors) psig bar(e) psig bar(e) psig bar(e) psig

Minimum setting

78

5.4

78

5.4

78

5.4

78

Factory setting

91.4

8

116

9.7

140.7

11.4

165.3

Maximum setting

101.5

8.7

126.2

10.4

150.8

12.1

175.5

Parameters

Motor running time in star

Load delay time (star-delta)

Number of motor starts

Minimum stop time

Programmed stop time

Power recovery time (ARAVF)

Restart delay

Communication time-out

Protections

sec sec starts/day sec sec sec sec sec

10

0

10

0

10

5

0

Minimum setting

0

20

3

10

0

30

Factory setting

10

0

240

Maximum setting

10

10

480

30

20

3600

1200

60

Compressor element outlet temperature

(shut-down warning level)

Compressor element outlet temperature

(shut-down warning level)

Compressor element outlet temperature

(shut-down level)

Compressor element outlet temperature

(shut-down level)

˚C

˚F

˚C

˚F

Minimum setting

50

122

111

232

Factory setting

110

230

120

248

Maximum setting

119

246

120

248

Service plan

The built-in service timer will give a Service warning message after a preprogrammed time interval has elapsed.

Also see section Preventive maintenance schedule

.

Consult Atlas Copco if a timer setting has to be changed. See section

Calling up/modifying service timer settings

. The intervals must not exceed the nominal intervals and must coincide logically.

66 2920 7090 51

Instruction book

Terminology

Term

ARAVF

Power recovery time

Restart delay

Compressor element outlet

Delay at shutdown signal

Minimum stop time

Unloading/

Loading pressure

Explanation

Automatic restart after voltage failure. See section Elektronikon regulator

and

Activating automatic restart

.

Is the period within which the voltage must be restored to have an automatic restart. Is accessible if the automatic restart is activated. To activate the automatic restart function, consult Atlas Copco.

This parameter allows to programme that not all compressors are restarted at the same time after a power failure (ARAVF active).

The regulator does not accept inconsistent settings, e.g. if the warning level is programmed at 95 ˚C (203 ˚F), the minimum limit for the shut-down level changes to 96 ˚C (204 ˚F). The recommended difference between the warning level and shut-down level is 10 ˚C (18 ˚F).

Is the time for which the signal must exist before the compressor is shut down. If it is required to program this setting to another value, consult Atlas Copco.

Once the compressor has automatically stopped, it will remain stopped for the minimum stop time, whatever happens with the net air pressure. Consult Atlas Copco if a setting lower than 20 seconds is required.

The regulator does not accept illogical settings, e.g. if the unloading pressure is programmed at 7.0 bar(e) (101 psi(g)), the maximum limit for the loading pressure changes to 6.9 bar(e) (100 psi(g)). The recommended minimum pressure difference between loading and unloading is 0.6 bar (9 psi(g)).

2920 7090 51 67

4 Elektronikon® Graphic controller

4.1

Elektronikon

®

Graphic controller

Control panel

Instruction book

Display of the Elektronikon

®

Graphic controller

Introduction

The Elektronikon controller has following functions:

• Controlling the compressor

• Protecting the compressor

• Monitoring components subject to service

• Automatic restart after voltage failure (made inactive)

Automatic control of the compressor operation

The regulator maintains the net pressure between programmable limits by automatically loading and unloading the compressor. A number of programmable settings, e.g. the unloading and loading pressures, the minimum stop time and the maximum number of motor starts are taken into account.

The regulator stops the compressor whenever possible to reduce the power consumption and restarts it automatically when the net pressure decreases. In case the expected unloading period is too short, the compressor is kept running to prevent too short standstill periods.

A number of time based automatic start/stop commands may be programmed. Take into account that a start command will be executed (if programmed and activated), even after manually stopping the compressor.

68 2920 7090 51

Instruction book

Protecting the compressor

Shut-down

Several sensors are provided on the compressor. If one of these measurements exceeds the programmed shutdown level, the compressor will be stopped. This will be indicated on display (1) and general alarm LED (2) will blink.

Remedy the trouble and reset the message. See also the

Inputs menu .

Before remedying, consult the applicable safety precautions.

Shut-down warning

A shut-down warning level is a programmable level below the shut-down level.

If one of the measurements exceeds the programmed shut-down warning level, a message will appear on display (1) and general alarm LED (2) will light up, to warn the operator that the shut-down warning level is exceeded.

The message disappears as soon as the warning condition disappears.

Warning

A warning message will appear if, on full-Feature compressors, the Dewpoint temperature is too high in relation to the ambient temperature

Service warning

A number of service operations are grouped (called Service Plans). Each Service Plan has a programmed time interval. If a time interval is exceeded, a message will appear on display (1) to warn the operator to carry out the service actions belonging to that Service Plan.

Automatic restart after voltage failure

The regulator has a built-in function to automatically restart the compressor if the voltage is restored after voltage failure. For compressors leaving the factory, this function is made inactive. If desired, the function can be activated. Consult the Atlas Copco Customer Centre.

If activated and provided the regulator was in the automatic operation mode, the compressor will automatically restart if the supply voltage to the module is restored.

2920 7090 51 69

Instruction book

4.2

Control panel

Elektronikon regulator

Parts and functions

Reference Designation

1 Display

4

5

2

3

6

7

8

9

10

Pictograph

Pictograph

General alarm LED

Pictograph

Service LED

Automatic operation LED

Voltage on LED

Pictograph

Enter key

11

12

13

14

Escape key

Scroll keys

Stop button

Start button

Control panel

Function

Shows the compressor operating condition and a number of icons to navigate through the menu.

Automatic operation

General alarm

Flashes if a shut-down warning condition exists.

Service

Lights up if service is needed

Indicates that the regulator is automatically controlling the compressor.

Indicates that the voltage is switched on.

Voltage on

Key to select the parameter indicated by the horizontal arrow. Only the parameters followed by an arrow pointing to the right can be modified.

To go to previous screen or to end the current action

Keys to scroll through the menu.

Button to stop the compressor. LED (7) goes out.

Button to start the compressor. LED (7) lights up indicating that the Elektronikon regulator is operative.

70 2920 7090 51

Instruction book

4.3

Icons used

Status icons

Name

Stopped / Running

Compressor status

Machine control mode

Automatic restart after voltage failure

Week timer

Active protection functions

Service

Icon Description

When the compressor is stopped, the icon stands still.

When the compressor is running, the icon is rotating.

Motor stopped

Running unloaded

Running loaded

Local start / stop

Remote start / stop

Network control

Automatic restart after voltage failure is active

Week timer is active

Emergency stop

Shutdown

Warning

Service required

2920 7090 51 71

Instruction book

Input icons

Icon Description

Pressure temperature

Digital input

Special protection

System icons

Icon Description

Compressor element (LP, HP, …)

Dryer

Fan

Frequency converter

Drain

Filter

Motor

Failure expansion module

Network problem

General alarm

72 2920 7090 51

Instruction book

Menu icons

Icon Description

Inputs

Outputs

Alarms (Warnings, shutdowns)

Counters

Test

Settings

Service

Event history (saved data)

Access key / User password

Network

Setpoint

Info

Navigation arrows

Icon Description

Up

Down

2920 7090 51 73

Instruction book

4.4

Main screen

Control panel

(1)

(2)

(3)

Scroll keys

Enter key

Escape key

Function

The Main screen shows the status of the compressor operation and is the gateway to all functions implemented in the controller.

The Main screen is shown automatically when the voltage is switched on and one of the keys is pushed. It is switched off automatically after a few minutes when no keys are pushed.

Typical Main screen, fixed speed compressors

74

Typical Main screen, compressors with frequency converter

2920 7090 51

Instruction book

Text on figures

(1)

(2)

(3)

(4)

(5)

Compressor Outlet

Element Outlet (fixed speed compressors)

Flow in % (compressors with frequency converter)

Load (text varies upon the compressors actual condition)

Menu

Unload (text varies upon the compressors actual condition)

Section A

shows information regarding the compressor operation (e.g. the outlet pressure (1), the temperature at the compressor outlet (2)). On compressors with a frequency converter, the load degree

(flow) is given in % of the maximum flow.

Section B

shows Status icons. Following icon types are shown in this field:

• Fixed icons

These icons are always shown in the main screen and cannot be selected by the cursor (e.g. Compressor stopped or running, Compressor status (running, running unloaded or motor stopped).

• Optional icons

These icons are only shown if their corresponding function is activated (e.g. week timer, automatic restart after voltage failure , etc.)

• Pop up icons

These icons pop up if an abnormal condition occurs (warnings, shutdowns, service,…)

To call up more information about the icons shown, select the icon using the scroll keys and press the enter key.

Section C

is called the Status bar

This bar shows the text that corresponds to the selected icon.

Section D

shows the Action buttons. These buttons are used:

• to call-up or program settings

• to reset a motor overload, service message or emergency stop

• to have access to all data collected by the regulator

The function of the buttons depends on the displayed menu. The most common functions are:

Designation

Menu

Modify

Reset

Function

To go to the menu

To modify programmable settings

To reset a timer or message

To activate an action button, highlight the button by using the Scroll keys and press the Enter key.

To go back to the previous menu, press the Escape key.

2920 7090 51 75

Instruction book

4.5

Calling up menus

Control panel

Control panel

(1)

(2)

(3)

Scroll keys

Enter key

Escape key

Description

When the voltage is switched on, the main screen is shown automatically (see section Main screen

):

• To go to the Menu screen, highlight the Menu button (3), using the Scroll keys.

• Press the Enter key to select the menu. Following screen appears:

76

• The screen shows a number of icons. Each icon indicates a menu item. By default, the Pressure Settings

(Regulation) icon is selected. The status bar shows the name of the menu that corresponds with the selected icon.

• Use the Scroll keys to select an icon.

2920 7090 51

Instruction book

• Press the Escape key to return to the Main screen.

4.6

Inputs menu

Control panel

(1)

(2)

(3)

Menu icon, Inputs

Scroll keys

Enter key

Escape key

Function

To call up information regarding the actually measured data and the status of some inputs such as the emergency stop switch.

Procedure

Starting from the main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

Text on figure

2920 7090 51 77

Instruction book

(1)

(2)

Menu

Regulation

• Using the Scroll keys, move the cursor to the Inputs icon (see above, section Menu icon).

• Press the Enter key. A screen similar to the one below appears:

Text on figure

(1)

(2)

(3)

(4)

(5)

Inputs

Compressor outlet

Element outlet

Ambient air

Emergency stop

• The screen shows a list of all inputs with their corresponding icons and readings.

• If an input is in warning or shutdown, the original icon is replaced by the warning or shutdown icon respectively (i.c. the Stop icon and the Warning icon in the screen shown above).

4.7

Outputs menu

Control panel

78

(1)

(2)

(3)

Scroll keys

Enter key

Escape key

2920 7090 51

Instruction book

Menu icon, Outputs

Function

To call up information regarding the actual status of some outputs such as the condition of the Fan overload contact (on air cooled compressors), the Emergency stop contact, etc.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

Text on figure

(1)

(2)

Menu

Regulation

• Move the cursor to the Outputs icon (see above, section Menu icon, using the Scroll keys.

• Press the Enter key. A screen similar to the one below appears:

(1)

(2)

(3)

(4)

(5)

Outputs

Fan motor contact

Blow-off contact

General shutdown

Automatic operation

• The screen shows a list of all outputs with their corresponding icons and readings.

• If an input is in warning or shutdown, the original icon is replaced by the warning or shutdown icon respectively.

2920 7090 51 79

Instruction book

4.8

Counters

Control panel

(1)

(2)

(3)

Menu icon, Counters

Scroll keys

Enter key

Escape key

Function

To call up:

• The running hours

• The loaded hours

• The number of motor starts

• The number of hours that the regulator has been powered

• The number of load cycles

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

80

Text on figure

2920 7090 51

Instruction book

(1)

(2)

Menu

Regulation

• Using the Scroll keys, move the cursor to the Counters icon (see above, section Menu icon)

• Press the Enter key. Following screen appears:

Text on figure

(1)

(2)

(3)

(4)

(5)

Counters

Running hours

Motor starts

Load relay

VSD 1-20 % rpm in % (the percentage of the time during which the motor speed was between 1 and 20 %) (compressors with frequency converter)

The screen shows a list of all counters with their actual readings.

Note

: the example above is for a frequency converter driven compressor. For a fixed speed compressor, the actual screen will be somewhat different.

4.9

Service menu

Control panel

(1)

(2)

(3)

2920 7090 51

Scroll keys

Enter key

Escape key

81

Instruction book

Menu icon, Service

Function

• To reset the service plans which are carried out.

• To check when the next service plans are to be carried out.

• To find out which service plans were carried out in the past.

• To modify the programmed service intervals.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

• Using the Scroll keys, move the cursor to the Service icon (see above, section Menu icon).

• Press the Enter key. Following screen appears:

82

Text on figure

(1)

(2)

(3)

(4)

(5)

Service

Overview

Service plan

Next service

History

• Scroll through the items to select the desired item and press the Enter key to see the details as explained below.

2920 7090 51

Instruction book

Overview

Text on figure

(1)

(2)

(3)

(4)

Overview

Running Hours (green)

Real Time hours (blue)

Reset

Example for service level (A):

The figures at the left are the programmed service intervals. For Service interval A, the programmed number of running hours is 4000 hours (upper row, green) and the programmed number of real time hours is 8760 hours, which corresponds to one year (second row, blue). This means that the controller will launch a service warning when either 4000 running hours or 8760 real hours are reached, whichever comes first. Note that the real time hours counter keeps counting, also when the controller is not powered.

The figures within the bars are the number of hours to go till the next service intervention. In the example above, the compressor was just started up, which means it still has 4000 running hours or 8280 hours to go before the next Service intervention.

Service plans

A number of service operations are grouped (called Level A, Level B, etc…). Each level stands for a number of service actions to be carried out at the time intervals programmed in the Elektronikon controller.

When a service plan interval is reached, a message will appear on the screen.

After carrying out the service actions related to the indicated levels, the timers must be reset.

From the Service menu above, select Service plan (3) and press Enter. Following screen appears:

Text on figure

2920 7090 51 83

Instruction book

(1)

(2)

(3)

(4)

(5)

Service plan

Level

Running hours

Real time hours

Modify

Modifying a service plan

Dependant on the operating conditions, it can be necessary to modify the service intervals. To do so, use the

Scroll keys to select the value to be modified. A screen similar to the one below appears:

Press the Enter key. Following screen appears:

Modify the value as required using the ↑ or ↓ scroll key and press the Enter key to confirm.

Note:

Running hours can be modified in steps of 100 hours, real time hours can be modified in steps of 1 hour.

Next Service

84

Text on figure

2920 7090 51

Instruction book

(1)

(2)

(3)

(4)

Next service

Level

Running hours

Actual

In the example above, the A Service level is programmed at 4000 running hours, of which 0 hours have passed.

History

The History screen shows a list of all service actions done in the past, sorted by date. The date at the top is the most recent service action. To see the details of a completed service action (e.g. Service level, Running hours or Real time hours), use the Scroll keys to select the desired action and press the Enter key.

4.10 Setpoint menu

Control panel

(1)

(2)

(3)

Menu icon, Setpoint

Scroll keys

Enter key

Escape key

Function

On fixed speed compressors

, the operator can program two different pressure bands. This menu is also used to select the active pressure band.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

2920 7090 51 85

Instruction book

Text on figure

(1)

(2)

Menu

Regulation

• Move the cursor to the Setpoint icon (see above, section menu icon) using the Scroll keys.

• Press the Enter key. Following screen appears:

Text on figure

(1)

(2)

(3)

(4)

(5)

(6)

Regulation

Unloading pressure 1

Loading pressure 1

Unloading pressure 2

Loading pressure 2

Modify

• The screen shows the actual unloading and loading pressure settings for both pressure bands.

To modify the settings, move the cursor to the action button Modify and press the Enter key. Following screen appears:

86

• The first line of the screen is highlighted in red. Use the Scroll keys to highlight the setting to be modified and press the Enter key. Following screen appears:

2920 7090 51

Instruction book

• The upper and lower limit of the setting is shown in grey, the actual setting is shown in black. Use the ↑ or ↓ key of the Scroll keys to modify the settings as required and press the Enter key to accept.

If necessary, change the other settings as required in the same way as described above.

4.11 Event history menu

Control panel

(1)

(2)

(3)

Menu icon, Event History

Scroll keys

Enter key

Escape key

Function

To call up the last shut-down and last emergency stop data.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

2920 7090 51 87

Instruction book

• Using the Scroll keys, move the cursor to the Event History icon (see above, section Menu icon)

• The list of last shut-down and emergency stop cases is shown.

• Scroll through the items to select the desired shut-down or emergency stop event.

• Press the Enter key to find the date, time and other data reflecting the status of the compressor when that shut-down or emergency stop occurred.

4.12 Modifying general settings

Control panel

(1)

(2)

(3)

Menu icon, Settings

Scroll keys

Enter key

Escape key

Function

To display and modify a number of general settings (e.g. Time, Date, Date format, Language, units …)

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

88 2920 7090 51

Instruction book

• Using the Scroll keys, move the cursor to the Settings icon (see above, section menu icon).

• Press the Enter key. Following screen appears:

Text on figure

(1)

(2)

(3)

(4)

(5)

(6)

General

Language used

Time

Date

Date format

Modify

• To modify, select the Modify button using the Scroll keys and press the Enter key.

• A screen similar to the one above is shown, a red selection bar is covering the first item (Language). Use the ↓ key of the Scroll keys to select the setting to be modified and press the Enter key.

• A pop-up screen appears. Use the ↑ or ↓ key to select the required parameter and press the Enter key to confirm.

4.13 Info menu

Control panel

2920 7090 51 89

Instruction book

(1)

(2)

(3)

Menu icon, Info

Scroll keys

Enter key

Escape key

Function

To show the Atlas Copco internet address.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

• Using the Scroll keys, move the cursor to the Info icon (see above, section Menu icon).

• Press the Enter key. The Atlas Copco internet address appears on the screen.

4.14 Week timer menu

Control panel

90 2920 7090 51

Instruction book

(1)

(2)

(3)

Menu icon, Week timer

Scroll keys

Enter key

Escape key

Function

• To program time-based start/stop commands for the compressor

• To program time-based change-over commands for the net pressure band

• Four different week schemes can be programmed.

• A week cycle can be programmed, a week cycle is a sequence of 10 weeks. For each week in the cycle, one of the four programmed week schemes can be chosen.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Use the Scroll buttons to select the

Timer icon.

Text on figure

(1)

(2)

Menu

Week Timer

• Press the Enter key on the controller. Following screen appears:

2920 7090 51 91

Instruction book

(1)

(2)

(3)

(4)

(5)

(6)

Week Timer

Week Action Schemes

Week Cycle

Status

Week Timer Inactive

Remaining Running Time

The first item in this list is highlighted in red. Select the item requested and press the Enter key on the controller to modify.

Programming week schemes

• Select Week action schemes and press Enter. A new window opens. The first item in the list is highlighted in red. Press the Enter key on the controller to modify Week Action Scheme 1.

(1)

(2)

(3)

(4)

(5)

Week Action Schemes

Week Action Scheme 1

Week Action Scheme 2

Week Action Scheme 3

Week Action Scheme 4

• A weekly list is shown. Monday is automatically selected and highlighted in red. Press the Enter key on the controller to set an action for this day.

92

(1)

(2)

(3)

(4)

(5)

Week Action Scheme 1

Monday

Tuesday

Wednesday

Thursday

2920 7090 51

Instruction book

(6)

(7)

(8)

Friday

Saturday

Sunday

• A new window opens. The Modify action button is selected. Press the enter button on the controller to create an action.

(1)

(2)

Monday

Modify

• A new pop-up window opens. Select an action from this list by using the Scroll keys on the controller.

When ready press the Enter key to confirm.

(1)

(2)

(3)

(4)

(5)

(6)

(7)

Monday

Actions

Remove

Start

Stop

Pressure Setpoint 1

Modify

• A new window opens. The action is now visible in the first day of the week.

2920 7090 51 93

Instruction book

(1)

(2)

(3)

(4)

Monday

Start

Save

Modify

• To adjust the time, use the Scroll keys on the controller and press the Enter key to confirm.

(1)

(2)

(3)

(4)

Monday

Start

Save

Modify

• A pop-up window opens. Use the ↑ or ↓ key of Scroll keys to modify the values of the hours. Use the ← or → Scroll keys to modify the minutes.

94

(1)

(2)

(3)

(4)

Monday

Time

Save

Modify

2920 7090 51

Instruction book

• Press the Escape key on the controller. The action button Modify is selected. Use the Scroll keys to select the action Save.

(1)

(2)

(3)

(4)

Monday

Start

Save

Modify

• A new pop-up window opens. Use the Scroll keys on the controller to select the correct actions. Press the

Enter key to confirm.

(1)

(3)

(4)

(5)

(6)

(7)

Monday

Are you sure?

No

Yes

Save

Modify

Press the Escape key to leave this window.

• The action is shown below the day the action is planned.

2920 7090 51 95

Instruction book

(6)

(7)

(8)

(1)

(2)

(3)

(4)

(5)

Week Action Scheme 1

Monday — Start

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

Press the Escape key on the controller to leave this screen.

Programming the week cycle

A week cycle is a sequence of 10 weeks. For each week in the cycle, one of the four programmed week schemes can be chosen.

• Select Week Cycle from the main Week Timer menu list.

(1)

(2)

(3)

(4)

(5)

(6)

• A list of 10 weeks is shown.

Week Timer

Week Action Schemes

Week Cycle

Status

Week Timer Inactive

Remaining Running Time

96

(1)

(2)

Week Cycle

Week 1

2920 7090 51

Instruction book

(3)

(4)

(5)

(6)

Week 2

Week 3

Week 4

Modify

Press twice the Enter key on the controller to modify the first week.

• A new window opens. Select the action, example: Week Action Scheme 1

(4)

(5)

(6)

(1)

(2)

(3)

Week Cycle

Week 1

Week Action Scheme 1

Week Action Scheme 2

Week Action Scheme 3

Modify

• Check the status of the Week Timer

Use the Escape key on the controller to go back to the main Week Timer menu. Select the status of the

Week Timer.

(4)

(5)

(6)

(1)

(2)

(3)

Week Timer

Week Action Schemes

Week Cycle

Status

Week Timer Inactive

Remaining Running Time

• A new window opens. Select Week 1 to set the Week Timer active.

2920 7090 51 97

98

Instruction book

(1)

(2)

(3)

(4)

Week Timer

Week

Week Timer Inactive

Week 1

• Press the Escape key on the controller to leave this window. The status shows that week 1 is active.

(1)

(2)

(3)

(4)

(5)

Week Timer

Week Action Schemes

Week Cycle

Status

Remaining Running Time

• Press the Escape key on the controller to go to the main Week Timer menu. Select Remaining Running

Time from the list and press the Enter key on the controller to Modify.

2920 7090 51

Instruction book

(1)

(2)

(3)

(4)

(5)

Week Timer

Week Action Schemes

Week Cycle

Status

Remaining Running Time

• This timer is used when the week timer is set and for certain reasons the compressor must continue working, for example, 1 hour, it can be set in this screen. This timer is prior to the Week Timer action.

(1)

(2)

(3)

4.15 Test menu

Control panel

Week Timer

Week action schemes

Remaining Running Time

Menu icon, Test

Function

• To carry out a display test, i.e. to check whether the display and LEDs are still intact.

2920 7090 51 99

Instruction book

Procedure

Starting from the Main screen (see

Main screen ):

• Move the cursor to the action button Menu and press the enter key (2), following screen appears:

• Using the scroll keys (1), move the cursor to the test icon (see above, section Menu icon)

• Press the enter key (2), following screen appears:

• The safety valve test can only be performed by authorized personnel and is protected by a security code.

• Select the item display test and press the enter key. A screen is shown to inspect the display, at the same time all LED’s are lit.

4.16 User password menu

Control panel

100

(1)

(2)

(3)

Scroll keys

Enter key

Escape key

2920 7090 51

Instruction book

Menu icon, Password

Function

If the password option is activated, it is impossible for not authorized persons to modify any setting.

Procedure

Starting from the Main screen (see

Main screen ),

• Move the cursor to the action button Menu and press the Enter key. Following screen appears:

• Using the Scroll keys, move the cursor to the Password icon (see above, section Menu icon)

• Press the Enter key.

• Select the Modify button using the Scroll keys and press the Enter key. Next, modify the password as required.

4.17 Web server

All Elektronikon controllers have a built-in web server that allows direct connection to a PC via a local area network (LAN). This allows to consult certain data and settings via the PC instead of via the display of the controller.

Getting started

Make sure you are logged in as administrator.

• Use the internal network card from your computer or an USB to LAN adapter (see picture below).

USB to LAN adapter

• Use an UTP cable (CAT 5e) to connect to the controller (see picture below).

2920 7090 51 101

Instruction book

Configuration of the network card

• Go to My Network places (1).

• Click on View Network connections (1).

102

• Select the Local Area connection (1), which is connected to the controller.

2920 7090 51

Instruction book

• Click with the right button and select properties (1).

• Use the checkbox Internet Protocol (TCP/IP) (1) (see picture). To avoid conflicts, de-select other properties if they are selected. After selecting TCP/IP, click on the Properties button (2) to change the settings.

• Use the following settings:

• IP Address 192.168.100.200

• Subnetmask 255.255.255.0

Click OK and close network connections.

Configuration of the web server

Configure the web interface

The internal web server is designed and tested for Microsoft® Internet Explorer 6, 7 and

8. Other web browsers like Opera and Firefox do not support this internal web server.

When using Opera or Firefox, a redirect page opens. Click on the hyperlink to connect to the download server from Microsoft® to download the latest version of Internet Explorer, and install this software.

2920 7090 51 103

• When using Internet Explorer:

Open Internet Explorer and click on Tools — Internet options (2).

Instruction book

• Click on the Connections tab (1) and then click on the LAN settings button (2).

104

• In the Proxy server Group box, click on the Advanced button (1).

2920 7090 51

Instruction book

• In the Exceptions Group box, enter the IP address of your controller. Multiple IP addresses can be given but they must be separated with semicolons (;).

Example: Suppose that you already added two IP addresses (192.168.100.1 and 192.168.100.2). Now you add 192.168.100.100 and separate the 3 IP addresses by putting semicolons between them (1) (see picture).

Click OK (2) to close the window.

Viewing the controller data

• Open your browser and type the IP address of the controller you want to view in your browser (in this example http://192.168.100.100). The interface opens:

2920 7090 51 105

Instruction book

Navigation and options

• The banner shows the compressor type and the language selector. In this example, three languages are installed on the controller.

106

• On the left site of the interface you can find the navigation menu (see picture below).

If a license for ESi is foreseen, the menu contains 3 buttons.

• Compressor: shows all compressor settings.

• Es: shows the ESi status (if a license is provided).

• Preferences: allows to change temperature and pressure unit.

2920 7090 51

Instruction book

Compressor settings

All compressor settings can be hidden or shown. Put a mark for each setting. Only the machine status is fixed and can not be removed from the main screen.

Analog inputs

(The units of measure can be changed in the preference button from the navigation menu).

Counters

Counters give an overview of all actual counters from controller and compressor.

Info status

Machine status is always shown on the web interface.

Digital inputs

Gives an overview of all Digital inputs and status.

2920 7090 51 107

Instruction book

Digital outputs

Shows a list of all digital outputs and their status.

Special protections

Give an overview of all special protections of the compressor.

Service plan

Shows all levels of the service plan and status. This screen only shows the running hours. It is also possible to show the actual status of the service interval.

108

ES screen controller

If a ESi license is provided, the button ES is shown in the navigation menu. At the left all compressors in the

ES and at the right the ES status is shown.

2920 7090 51

Instruction book

A possible ESi screen

4.18 Programmable settings

Parameters: unloading/loading pressures for compressors without built-in refrigeration dryer

Minimum setting

Factory setting

Maximum setting

Unloading pressures

Unloading pressure (7.5 bar compressors) bar(e)

Unloading pressure (7.5 bar compressors) psig

Unloading pressure (8.5 bar compressors) bar(e)

Unloading pressure (8.5 bar compressors) psig

Unloading pressure (10 bar compressors) bar(e)

Unloading pressure (10 bar compressors) psig

Unloading pressure (13 bar compressors) bar(e)

Unloading pressure (13 bar compressors) psig

Unloading pressure (100 psi compressors) bar(e)

Unloading pressure (100 psi compressors) psig

Unloading pressure (125 psi compressors) bar(e)

Unloading pressure (125 psi compressors) psig

Unloading pressure (150 psi compressors) bar(e)

Unloading pressure (150 psi compressors) psig

Unloading pressure (175 psi compressors) bar(e)

Unloading pressure (175 psi compressors) psig

Loading pressures

Loading pressure (7.5 bar compressors)

Loading pressure (7.5 bar compressors) bar(e) psig

Loading pressure (8.5 bar compressors)

Loading pressure (8.5 bar compressors) bar(e) psig

Loading pressure (10 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (13 bar compressors) bar(e) psig bar(e)

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.4

78

5.4

78

5.4

78

5.4

6.9

100

8.6

125

10.3

150

12

175

7

101.5

8.0

116.0

9.5

137.8

12.5

181.3

6.4

92.8

7.4

107.3

8.9

129.1

11.9

7.4

107.3

8.4

121.8

9.9

143.6

12.9

7.4

107.3

9.1

132

10.8

156.6

12.5

181.2

7.5

108.8

8.5

123.3

10

145.0

13

188.6

2920 7090 51 109

Instruction book

Loading pressure (13 bar compressors)

Loading pressure (100 psi compressors)

Loading pressure (100 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (175 psi compressors)

Loading pressure (175 psi compressors) psig bar(e) psig bar(e) psig bar(e) psig bar(e) psig

78

5.4

78

5.4

78

Minimum setting

78

5.4

78

5.4

Factory setting

172.6

6.3

91.4

8

116

9.7

140.7

11.4

165.3

Parameters: unloading/loading pressures for compressors with built-in refrigeration dryer

Minimum setting

Factory setting

Maximum setting

Unloading pressures

Unloading pressure (7.5 bar compressors) bar(e)

Unloading pressure (7.5 bar compressors) psig

Unloading pressure (8.5 bar compressors) bar(e)

Unloading pressure (8.5 bar compressors) psig

Unloading pressure (10 bar compressors) bar(e)

Unloading pressure (10 bar compressors) psig

Unloading pressure (13 bar compressors) bar(e)

Unloading pressure (13 bar compressors) psig

Unloading pressure (100 psi compressors) bar(e)

Unloading pressure (100 psi compressors) psig

Unloading pressure (125 psi compressors) bar(e)

Unloading pressure (125 psi compressors) psig

Unloading pressure (150 psi compressors) bar(e)

Unloading pressure (150 psi compressors) psig

Unloading pressure (175 psi compressors) bar(e)

Unloading pressure (175 psi compressors) psig

Loading pressures

Loading pressure (7.5 bar compressors)

Loading pressure (7.5 bar compressors)

Loading pressure (8.5 bar compressors) bar(e) psig bar(e)

Loading pressure (8.5 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (10 bar compressors)

Loading pressure (13 bar compressors)

Loading pressure (13 bar compressors)

Loading pressure (100 psi compressors) psig bar(e) psig bar(e) psig bar(e)

5.4

78

5.4

78

5.4

78

5.4

78

5.4

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

80

5.5

5.5

80

6.4

92.8

7.4

107.3

8.9

129.1

11.9

172.6

6.3

181.3

6.9

100

8.6

125

10.3

150

7

101.5

8.0

116.0

9.5

137.8

12.5

12

175

7.2

104.4

8.1

117.5

9.6

139.2

12.6

182.8

7

184.2

7.1

103

8.8

127.6

10.5

152.3

7.3

105.8

8.25

119.7

9.7

140.7

12.7

12.2

177

110

Maximum setting

187.1

7.3

105.9

9

130.5

10.7

155.2

12.4

179.8

2920 7090 51

Instruction book

Loading pressure (100 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (125 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (150 psi compressors)

Loading pressure (175 psi compressors)

Loading pressure (175 psi compressors) psig bar(e) psig bar(e) psig bar(e) psig

Parameters

Motor running time in star

Load delay time (star-delta)

Number of motor starts

Minimum stop time

Programmed stop time

Power recovery time (ARAVF)

Restart delay

Communication time-out

Protections

Minimum setting

78

5.4

78

5.4

78

5.4

78

Factory setting

91.4

8

116

9.7

140.7

11.4

165.3

sec sec starts/day sec sec sec sec sec

10

0

10

0

10

5

0

Minimum setting

0

20

3

10

0

30

Factory setting

10

0

240

Compressor element outlet temperature

(shut-down warning level)

Compressor element outlet temperature

(shut-down warning level)

Compressor element outlet temperature

(shut-down level)

Compressor element outlet temperature

(shut-down level)

˚C

˚F

˚C

˚F

Minimum setting

50

122

111

232

Factory setting

110

230

120

248

Maximum setting

101.5

8.7

126.2

10.4

150.8

12.1

175.5

Maximum setting

10

10

480

30

20

3600

1200

60

Maximum setting

119

246

120

248

Service plan

The built-in service timers will give a Service warning message after their respective preprogrammed time interval has elapsed.

Also see section.

Consult Atlas Copco if a timer setting has to be changed. The intervals must not exceed the nominal intervals and must coincide logically. See section

Modifying general settings .

2920 7090 51 111

Instruction book

Terminology

Term

ARAVF

Power recovery time

Restart delay

Compressor element outlet

Delay at shutdown signal

Oil separator

Minimum stop time

Unloading/

Loading pressure

Explanation

Automatic Restart After Voltage Failure. See section Elektronikon regulator

.

Is the period within which the voltage must be restored to have an automatic restart. Is accessible if the automatic restart is activated. To activate the automatic restart function, consult Atlas Copco.

This parameter allows to programme that not all compressors are restarted at the same time after a power failure (ARAVF active).

The recommended minimum setting is 70 ˚C (158 ˚F). For testing the temperature sensor the setting can be decreased to 50 ˚C (122 ˚F). Reset the value after testing.

The regulator does not accept illogical settings, e.g. if the warning level is programmed at

95 ˚C (203 ˚F), the minimum limit for the shut-down level changes to 96 ˚C (204 ˚F). The recommended difference between the warning level and shut-down level is 10 ˚C (18 ˚F).

Is the time for which the signal must exist before the compressor is shut down. If it is required to program this setting to another value, consult Atlas Copco.

Use only Atlas Copco oil separators. The recommended maximum pressure drop over the oil separator element is 1 bar (15 psi).

Once the compressor has automatically stopped, it will remain stopped for the minimum stop time, whatever happens with the net air pressure. Consult Atlas Copco if a setting lower than 20 seconds is required.

The regulator does not accept inconsistent settings, e.g. if the unloading pressure is programmed at 7.0 bar(e) (101 psi(g)), the maximum limit for the loading pressure changes to 6.9 bar(e) (100 psi(g)). The recommended minimum pressure difference between loading and unloading is 0.6 bar (9 psi(g)).

112 2920 7090 51

Instruction book

5 OSD oil/condensate separator (optional)

5.1

OSD unit

Oil/condensate separators

Compressed air leaving oil-injected compressors contains oil. During cooling of this air, oil-containing condensate is formed. OSD are designed to separate the major part of this oil from the condensate and to catch the oil in a collector. The condensate meets the requirements of the environmental codes.

7

8

5

6

9

2

3

Reference

1

4

General view of OSD 22, typical example

Designation

Condensate vessel

Pressure gauge

Oil removal filter

Oil collector

Condensate inlet

Dp of filter

Clean condensate outlet

Oil outlet

Cover

2920 7090 51 113

Instruction book

Operation

Condensate containing fine oil droplets flows via a strainer (5) through filter (3), in which the droplets coalesce into larger drops. The condensate is then led to vessel (1) where the oil rises due to the difference in specific mass. The vessel is provided with two separated outlets: one for condensate (7), which is led outside the bodywork, and one for the separated oil (8), which is caught in collector (4).

5.2

Operating and maintenance instructions

Safety precautions

Before carrying out any maintenance, repair work or adjustments, proceed as follows:

• Stop the compressor.

• Close the air outlet valve and open, if provided, the manual condensate drain valve.

Close the air outlet valve and press the test button on top of the electronic water drain until the air system between air receiver and outlet valve is fully depressurized.

Press the emergency stop button.

• Switch off the voltage.

For detailed instructions, see Problem solving

.

The operator must apply all relevant

Safety precautions

.

Operating instructions

114

Inside of OSD

• Before starting, check that vessel (1) is filled. If necessary, gently pour water into filler pipe (2) or vessel

(1) until it flows through tube (3). Reinstall the cover.

• During operation of the compressor, an oil layer is built up above the water level in vessel (1). Depending on the capacity of the compressor and its operation cycle, the humidity of the inlet air and the oil content of the compressed air, it may take several weeks or months before an oil level is observed in collector (4).

• Regularly check that vessel (1) is filled. If necessary, gently pour water into filler pipe (2) or vessel (1) until it flows through tube (3). Keep the cover installed during operation.

2920 7090 51

Instruction book

Condensate drains

Maintenance instructions

Consult section OSD unit for the references.

Interval

Weekly

Monthly

Running hours Operation

50 Check pressure gauge (2). If the pressure reaches 2 bar(e) (29 psig) or every 6000 operating hours, replace filter (3): Unscrew the filter. Fill the new filter with water, lightly oil its gasket, screw it on and tighten by hand (approx. half a turn). Check strainer (5); if necessary, clean it.

200 Check the oil level in collector (4). If nearly full, disconnect oil tube (8) and deliver the oil to the local oil collection service. Reinstall an empty collector.

5.3

Pictographs

Pictographs shown on OSD

6

7

8

4

5

2

3

Reference

1

2920 7090 51

Description

Oil

Oil outlet

Condensate outlet

Pressure

Inlet

Service point drain

Separator inlet pressure

Oil gasket, screw on filter and tighten by hand (approx. half a turn)

115

Reference

9

Description

Consult instruction book before maintenance or repair

Instruction book

116 2920 7090 51

Instruction book

6 Installation

6.1

Dimension drawings

Drawings

2920 7090 51

GA 5 up to GA 11 Pack, Floor mounted

117

Instruction book

118

GA 5 up to GA 11 Pack on 270 l air receiver

2920 7090 51

Instruction book

2920 7090 51

GA 5 up to GA 11 Full-Feature, Floor mounted

119

Instruction book

120

GA 5 up to GA 11 Full-Feature on 270 l air receiver

2920 7090 51

Instruction book

2920 7090 51

GA 5 up to GA 11 Pack on 500 l air receiver

121

Instruction book

122

4

5

2

3

Reference

1

GA 5 up to GA 11 Full-Feature on 500 l air receiver

Designation

Compressor and motor cooling air inlet

Dryer cooling air outlet

Dryer air inlet

Compressed air outlet

Compressor air inlet

2920 7090 51

Instruction book

10

11

12

7

8

Reference

6

9

Designation

Manual drain

Automatic drain

Weight table

Electrical cable entry

Compressor and motor cooling air outlet

Oil level indicator

Valve rotation

6.2

Installation proposal

Outdoor/altitude operation

If the compressor is installed outdoors or if the air inlet temperature can be below 0 ˚C (32 ˚F), precautions must be taken. In this case, and also if operating above 1000 m (3300 ft), consult Atlas Copco.

Moving/lifting

To transport the compressor with a forklift truck, use the openings in the frame.

Move the compressor smoothly.

2920 7090 51 123

Installation proposal

Instruction book

124

Compressor room example

Text on drawing

Reference

(1)

(2)

Designation

Ventilation proposals

Minimum free area to be reserved for the compressor installation

2920 7090 51

Instruction book

All piping to be connected stress free to the compressor.

Installation guidelines

1. Install the compressor unit on a solid, level floor suitable for taking its weight. The recommended minimum distance between the top of the unit and the ceiling is 900 mm (35 in). The air receiver must not be bolted to the floor. The minimum distance between the wall and the back of the compressor must be 500 mm

(19.5 in).

2. Position of the compressed air outlet valve.

To facilitate the access to the dryer during maintenance operations, provide a flexible connection between the air outlet valve and the air net.

Close the valve.

Connect to the air net

3. The pressure drop over the air delivery pipe can be calculated from:

Δp = (L x 450 x Q c

1.85

) / (d

5

x P), with d = Inner diameter of the pipe in mm

Δp = Pressure drop in bar (recommended maximum: 0.1 bar (1.5 psi))

L = Length of the pipe in m

P = Absolute pressure at the compressor outlet in bar

Q c

= Free air delivery of the compressor in l/s

It is recommended that the connection of the compressor air outlet pipe is made on top of the main air net pipe in order to minimise carry-over of possible condensate residue.

4. Ventilation: the inlet grids and ventilation fan should be installed in such a way that any recirculation of cooling air to the compressor or dryer is avoided. The maximum air velocity through the grids is 5 m/s

(16.5 ft/s).

The maximum allowable pressure drop over the cooling air ducts is 30 Pa (0.12 in water column).

If it is greater than this value, a fan is needed at the outlet of the ducts. Consult Atlas Copco.

For alternatives 1 and 3, the required ventilation capacity to limit the compressor room temperature can be calculated as follows:

• Q v

= 1.16 N/ΔT for units without optional dryer

• Q v

= (1.16 N + 0.6)/ΔT for units with optional dryer

Q v

= Required ventilation capacity in m

N = Shaft input of compressor in kW

3

/s

ΔT = Temperature increase in the compressor room in °C

For alternatives 2 and 4:

the fan capacity should match the compressor fan capacity at a pressure head equal to the pressure drop across the air ducts.

5. The drain pipes to the drain collector must not dip into the water of the drain collector. Atlas Copco has oil/water separators (type OSD) to separate the major part of the oil from the condensate to ensure that the condensate meets the requirements of the environmental codes.

6. Position of control panel.

7. Mains cable

To preserve the protection degree of the electric cubicle and to protect its components from dust from the environment, it is mandatory to use the supply cable and cable gland delivered with the compressor.

8. Filter, type DD for general purposes (optional). The filter traps solid particles down to 1 micron with a max. oil carry-over of 0.5 mg/m

3

. A high-efficiency filter, type PD (optional), may be installed downstream of a DD filter. This filter traps solid particles down to 0.01 micron with max. oil carry-over of 0.01 mg/

2920 7090 51 125

Instruction book m

3

. If oil vapours and odours are undesirable, a QD type filter should be installed downstream of the PD filter.

It is recommended to provide by-pass pipes and valves across the filters in order to isolate the filters during maintenance without disturbing the compressor.

6.3

Electrical connections

Important remark

When connecting to electric supply leave 2 m (6.5 ft.) of loose cable to allow easy removal of back panel.

Always disconnect the power supply before working on the electrical circuit!

General instructions

IEC (CE) cubicle

126 2920 7090 51

Instruction book

3

4

Step

1

2

CSA/UL (cULus) cubicle

Action

Install an isolating switch near the compressor.

Check the fuses and the setting of overload relay. See section Settings of overload relay and fuses

.

If fitted, check transformers for connection.

Connect the power supply cables to terminals L1, L2 and L3 (1X0) and the neutral conductor (if applicable) to terminal (N). Connect the earth conductor.

Specific instructions for GA 5 up to GA 11 with 208 V/ 230 V / 460 V cubicle

Always disconnect the power supply before working on the electrical circuit!

The standard voltage configuration for the compressor is mentioned on the data plate of the machine. When the compressors leave the factory, the units are connected for 230 V / 3 phase.

2920 7090 51 127

Instruction book

To modify the wiring for an operating voltage of 208 V or 460 V, compressor main cubicle and transformer dryer cubicle should be rewired as described below:

128

4

5

6

Required modifications in the compressor cubicle:

Step

1

2

3

7

Action

Adjust the motor overload (FM1) setting.

Rewire the control transformer (T1).

Replace the control fuses (F1) with the 10.3 x 38 mm 2 A or 4 A fuses provided (see further).

Modify the motor terminal bridge configuration in the main cubicle for the desired voltage.

Replace the voltage sticker by the appropriate voltage sticker provided.

On FF units, replace the power fuses (F10 in the main cubicle) with the CC type 6 A fuses provided.

Modify the power transformer terminal bridge configuration in the transformer cubicle for the desired voltage.

To adjust the motor overload (FM1) setting, simply rotate the adjustment screw (1) on the front of the overload relay to the required setting (see table below).

2920 7090 51

Instruction book

Adjustment screw of the motor overload

Motor overload (FM1) setting

(A)

208 V

GA 5

33.0

230 V (standard factory setting) 30.0

460 V 15.0

GA 7

43.0

39.0

19.0

GA 11

61.0

55.0

27.5

To rewire the control transformer (T1), move the wire of the transformer to the terminal marked with the desired voltage (208 V, 230 V or 460 V).

Replace the two fuses marked F1 by opening the fuse-holder. Use the 4 A fuses for 208 — 230 V and the 2 A fuses for 460 V, supplied with the compressor.

Fuses

F1

F2

2920 7090 51

Fuse rating V

600 V AC

250 V AC

208 V

4 A

3 A

230 V

4 A

3 A

460 V

2 A

3 A

Class

UL class JDYX or JDYX2 10.3 x

38 mm

UL class JDYX or JDYX2 5 x 20 mm

129

Instruction book

Fuses

F3

F4

F5

F6

Fuse rating V

250 V AC

600 V AC

600 V AC

600 V AC

208 V

1 A

15 A

10 A

1 A

230 V

1 A

15 A

10 A

1 A

460 V

1 A

6 A

10 A

1 A

Class

UL class JDYX or JDYX2 5 x 20 mm

UL guide JDDZ class CC type

FNQ-R 10.3 x 38 mm

UL guide JDDZ class CC type

FNQ-R 10.3 x 38 mm

UL guide JDDZ class CC type

FNQ-R 10.3 x 38 mm

Note: Fuses F4 and F5 are only applicable to FF units. F6 only for option Phase Sequence Relay. See also section Electric diagrams.

To modify the terminal bridge configuration to the motor, configure the terminal bridges for the desired voltage

(208 V, 230 V or 460 V) according to the diagram below. The terminal bridges (1) can be easily removed using a pair of pliers. Additional terminal bridges are provided with the compressor. The connections for 230

V are the factory standard.

Locate the yellow voltage labels provided with the compressor. Replace the existing label with the appropriate voltage label (200 — 208 V, 230 V or 460 V).

Compressor status indication on compressors equipped with an Elektronikon® controller

The Elektronikon regulator is provided with an auxiliary relay (K05) for remote indication of a shutdown.

Maximum load for the contacts: 10 A / 250 V AC. Stop the compressor and switch off the voltage before connecting external equipment. Consult Atlas Copco.

Compressor status indication on compressors equipped with an Elektronikon® Graphic controller

The Elektronikon regulator is provided with auxiliary contacts (K05, K07 and K08) for remote indication of:

• manual load/unload or automatic operation (K07)

• warning condition (K08)

• shut-down condition (K05)

Maximum load for the contacts: 10 A / 250 V AC. Stop the compressor and switch off the voltage before connecting external equipment. Consult Atlas Copco.

130 2920 7090 51

Instruction book

Compressor control modes

Stop the compressor and switch off the voltage before connecting external equipment. Only voltage-free contacts are allowed.

The following control modes can be selected:

• Local control: The compressor will react to commands entered by the buttons on the control panel.

Compressor start/stop commands via Clock function are active, if programmed.

• Remote control: The compressor will react to commands from external switches. Emergency stop remains active. Compressor start/stop commands via Clock function are still possible.

For remote starting and stopping:

• Connect a start/programmed stop button (S1′) between terminals 30 and 33 of terminal (2×27) (input

DIO3 on the controller).

• Bridge terminals 30 and 39 of terminal (2×27) (input DIO4 on the controller) or connect a load/unload switch (S2′).

In this mode, the outlet pressure is still sensed by pressure transducer (PT20), resulting in loading and unloading of the compressor at the pressures programmed in the Elektronikon regulator. If the mentioned terminals are not bridged, the compressor is switched out of automatic load/unload operation and remains running unloaded.

For remote loading/unloading (via external pressure switch):

Compressors with an Elektronikon Graphic controller can also be wired to load and unload depending from the status of a pressure switch: Connect a load/unload (pressure) switch (S2′) between terminals 30 and 39 of terminal (2×27) (input DIO4 on the controller). This results in loading and unloading of the compressor at the closing and opening pressures of the external pressure switch respectively.

• LAN control: The compressor is controlled via a local network. Consult Atlas Copco.

See section

Electrical system to locate the connectors.

6.4

Pictographs

Description

3

4

Reference

1

2

2920 7090 51

Pictographs

Designation

Manual condensate drain

Automatic condensate drain

Warning: voltage

Warning: switch off the voltage and depressurise compressor before repairing

131

Instruction book

6

7

8

Reference

5

Designation

Warning: before connecting compressor electrically, consult Instruction book for motor rotation direction

Torques for steel (Fe) or brass (CuZn) bolts

Consult instruction book before greasing

Lightly oil gasket of oil filter, screw it on and tighten by hand (approx. half a turn)

132 2920 7090 51

Instruction book

7 Operating instructions

7.1

Initial start-up

Safety

The operator must apply all relevant

Safety precautions.

Procedure

For the position of the air outlet valve and the drain connections, see sections

Introduction

and Condensate system.

1. Consult the sections

Electric cable size,Installation proposals

and Dimension drawings

2. Check that the electrical connections correspond to the local codes and that all wires are clamped tight to their terminals.

The installation must be earthed and protected against short circuits by fuses of the inert type in all phases.

An isolating switch must be installed near the compressor.

3. Check transformer (T1) for correct connection.

Check the settings of drive motor overload relay (F21).

Check that the motor overload relay is set for manual resetting.

Electric cubicle, typical example

4. Fit the air outlet valve (AV); see section

Introduction for the position of the valve.

Close the valve.

Connect the air net to the valve.

5. Fit the manual condensate drain valve (Dm). Close the valve. Connect the valve to a drain collector.

2920 7090 51 133

Instruction book

6. Connect the automatic drain outlet (Da) to a drain collector.

The drain pipes to the drain collector must not dip into the water. If the pipes have been fitted outside the room where freezing is possible, they must be insulated. For draining of pure condensate water, install an

oil/water separator which is available from Atlas Copco as an option. See section OSD unit

.

7. Check the oil level.

The oil level sight-glass should be between 1/4 and 3/4 full.

134

Position of oil level sight-glass

8.

Provide labels, warning the operator that:

• The compressor may automatically restart after voltage failure (if activated, consult Atlas Copco).

• The compressor is automatically controlled and may be restarted automatically.

2920 7090 51

Instruction book

9.

• Affix the above sheet explaining the procedure for checking the motor rotation direction to the cooling air outlet of the compressor.

• Check the rotation direction of the motor using the sheet. If the motor rotation direction is correct, the sheet on the top grating will be blown upwards. If the sheet remains in place, the rotation direction is incorrect (see the pictographs on the label).

• If the rotation direction is incorrect, switch off the voltage, open the isolating switch and reverse two incoming supply lines.

10. Check the programmed settings. Consult section Programmable settings.

11. Start and run the compressor for a few minutes. Check that the compressor operates normally.

7.2

Before starting

Procedure

Check the oil level, top up if necessary. See section Initial start-up.

2920 7090 51 135

Instruction book

7.3

Starting

Procedure

For the position of the air outlet valve and the drain connections, see sections

Introduction

and Condensate system

Control panel of the Elektronikon® controller

136

Step

Control panel of the Elektronikon® Graphic controller

Action

Switch on the voltage. Check that voltage on LED (6) lights up.

Open the air outlet valve.

Close the condensate drain valve(s) (Dm).

Press start button (1) on the control panel. The compressor starts running and the automatic operation LED (8) lights up. Ten seconds after starting, the drive motor switches over from star to delta and the compressor starts running loaded.

2920 7090 51

Instruction book

7.4

During operation

Procedure

Control panel of the Elektronikon® controller

Control panel of the Elektronikon® Graphic controller

2920 7090 51 137

Instruction book

138

Position of oil level sight-glass and service indicator

Regularly check the oil level: Approximately three minutes after stopping, sight-glass (Gl) should be between

1/4 and 3/4 full. If the level is too low, stop the compressor, wait until the compressor has stopped, depressurise the oil system by unscrewing oil filler plug (FC) one turn and wait a few minutes. Remove the plug and top up oil, until the sight-glass is full. Fit and tighten the plug (FC).

When automatic operation LED (8) is lit, the regulator is automatically controlling the compressor, i.e. loading, unloading, stopping of the motors and restarting.

If provided, regularly check that condensate is discharged by the automatic drain(s) during operation. See section

Condensate system . The amount of condensate depends on environmental and working conditions.

If an OSD is installed, also check the level in the oil collector; see section OSD Maintenance and operating instructions .

2920 7090 51

Instruction book

7.5

Checking the display

Procedure

Control panel of the Elektronikon® controller

Control panel of the Elektronikon® Graphic controller

Compressors with Elektronikon® controller:

Check the display (2) regularly for readings and messages. The display normally shows the compressor outlet pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm LED

(7) is lit or flashes, see section Shutdown warning

, Shutdown and Problem solving. The display (2) will show

a service message if a service plan interval has been exceeded or if a service level for a monitored component has been exceeded. Carry out the service actions of the indicated plans or replace the component and reset

the relevant timer, see section Service warning

.

Compressors with Elektronikon® Graphic controller:

Check the display (2) regularly for readings and messages. The display normally shows the compressor outlet pressure,while the status of the compressor is indicated by means of a number of icons. Remedy the trouble

if alarm LED (7) is lit or flashes, see section Icons used

. The display (2) will show a service message if a service plan interval has been exceeded or if a service level for a monitored component has been exceeded.

Carry out the service actions of the indicated plans or replace the component and reset the relevant timer, see section

Service menu .

2920 7090 51 139

7.6

Stopping

Elektronikon regulator

Control panel of the Elektronikon® controller

Control panel of the Elektronikon® Graphic controller

Air outlet valve

Instruction book

140 2920 7090 51

Instruction book

Condensate drain valve, Tank-mounted GA 5 up to GA 11

Procedure

Step

Action

Press stop button (9). Automatic operation LED (8) goes out and the compressor stops after 30 seconds of unloaded operation.

To stop the compressor in the event of an emergency,

press emergency stop button (10).

Alarm LED flashes (7).

On compressors with an Elektronikon® controller: remedy the problem cause, unlock the button by pulling it out and press the Escape button (5) to reset.

On compressors with an Elektronikon® Graphic controller:

• Remedy the problem cause and unlock the button by pulling it out.

• Navigate to the Stop icon on the display by means of the navigation keys (3/4) and press the

Select key.

Press reset.

Do not use emergency stop button (10) for normal stopping!

Close the air outlet valve (AV).

Open the condensate drain valve (Dm). See section Condensate system.

The air dryer and air receiver remain under pressure.

The DD and PD filters (if installed) remain under pressure.

If maintenance or repair work is necessary, consult

Problem solving

for all relevant safety precautions.

7.7

Taking out of operation

Procedure

Step

Action

Stop the compressor and close the air outlet valve.

Switch off the voltage and disconnect the compressor from the mains.

Depressurise the compressor by opening plug (FC). Consult section Oil and oil filter change to

locate the filler plug.

Open the condensate drain valve (Dm). Consult section Condensate system

to locate the drain valve.

Shut off and depressurise the part of the air net which is connected to the outlet valve. Disconnect the compressor air outlet pipe from the air net.

Drain the oil.

2920 7090 51 141

142

Instruction book

Step Action

Drain the condensate circuit and disconnect the condensate piping from the condensate net.

Air outlet valve

Condensate drain valve, Tank-mounted GA 5 up to GA 11

2920 7090 51

Instruction book

8 Maintenance

8.1

Preventive maintenance schedule

Warning

Before carrying out any maintenance, repair work or adjustments, proceed as follows:

• Stop the compressor.

Press the emergency stop button.

• Switch off the voltage.

• Close the air outlet valve and open, if provided, the manual condensate drain valve.

• Depressurise the compressor.

For detailed instructions, see section Problem solving .

The operator must apply all relevant

Safety precautions

.

Warranty — Product Liability

Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts is not covered by Warranty or Product Liability.

Service kits

For overhauling or carrying out preventive maintenance, service kits are available (see section Service kits ).

Service contracts

Atlas Copco offers several types of service contracts, relieving you of all preventive maintenance work.

Consult your Atlas Copco Customer Centre.

General

When servicing, replace all removed gaskets, O-rings and washers.

Intervals

The local Atlas Copco Customer Centre may overrule the maintenance schedule, especially the service intervals, depending on the environmental and working conditions of the compressor.

The longer interval actions and checks must also include the shorter interval actions and checks.

Service actions for compressors with an Elektronikon® controller

Besides the daily and 3-monthly checks, the service operations are grouped in time intervals (running hours).

The regulator has a programmable service timer. A service warning will appear when the service timer has reached the programmed time interval; see section

Programmable settings

and section Service warning . In

this case, check the running hours. Carry out the service operations corresponding to the running hours as specified in the schedule below. Reset the service timer after servicing; see section

Calling up/resetting the service timer

.

2920 7090 51 143

Instruction book

Service plans for compressors with an Elektronikon® Graphic controller

Besides the daily and 3-monthly checks, preventive service operations are specified in the schedule below.

Each plan has a programmed time interval at which all service actions belonging to that plan are to be carried out. When reaching the interval, a message will appear on the screen indicating which service plans are to be

carried out; see section Programmable settings

and section Service menu . After servicing, the intervals must

be reset.

Preventive maintenance schedule

Drain the air receiver every day to reduce the risk for internal corrosion

Check list

Period

Daily

Monthly

3-monthly (1)

Operation

Check oil level.

Check readings on display.

Check that condensate is discharged during loaded operation.

Drain condensate (compressed air receiver).

Check the pressure dew-point temperature (compressors with integrated dryer).

For units with built-in dryer: Inspect condenser of dryer and clean if necessary.

Press the test button on top of the electronic water drain (EWD). Open the manual drain valve(s) (Dm, Dm1) to clean the filter inside the EWD.

Check coolers, clean if necessary.

On Full-Feature units: check condenser of dryer and clean if necessary.

Remove the air filter element and inspect. If necessary, clean using an air jet. Replace damaged or heavily contaminated elements.

Check the filter element of the electric cabinet (if applicable). Replace if necessary

(1): More frequently when operating in a dusty atmosphere.

Programmed service intervals

144 2920 7090 51

Instruction book

Frequency

(running hours)

2000

Operation

4000 (1) yearly

8000 (2)

For GA with integrated dryer: Clean condenser of dryer.

Clean the filter of the electronic drain by opening manual drain valve

(Dm, Dm1).

If Atlas Copco Roto-Foodgrade Fluid is used, change oil and oil filter.

If Atlas Copco Roto-Inject Fluid is used, change oil and oil filter.

If Atlas Copco Roto-Xtend Duty Fluid is used, change oil filter.

Replace the air filter element.

Replace the oil separator element.

Replace the filter element of the electric cabinet (if applicable).

Clean coolers.

Check pressure and temperature readings.

Carry out a LED/display test.

Check for leakages.

If provided, remove, dismantle and clean float valve of condensate

trap. See section Condensate system .

Clean the condenser of the dryer (Full-Feature compressors)

Test temperature shut-down function.

Test safety valve(s).

If Atlas Copco Roto-Xtend Duty Fluid is used, change oil.

Replace V-belts.

Have air inlet valve and minimum pressure valve inspected by Atlas

Copco.

(1): or yearly, whichever comes first

(2): or every 2 years, whichever comes first

Important

2920 7090 51

Test button on the EWD

• Always consult Atlas Copco if a service timer setting has to be changed.

For the change interval of oil and oil filter in extreme conditions, consult your Atlas

Copco Customer Centre.

Any leakage should be attended to immediately. Damaged hoses or flexible joints must be replaced.

145

Instruction book

8.2

Oil specifications

Never mix lubricants of different brands or types as they may not be compatible and the oil mix will have inferior properties. A label, indicating the type of oil filled ex-factory, is stuck on the air receiver/oil tank.

Always drain the compressor oil at all drain points. Used oil left in the compressor can contaminate the oil system and can shorten the lifetime of the new oil.

It is strongly recommended to use genuine Atlas Copco Lubricants. They are the result of years of field experience and research in our labs. See section Preventive maintenance schedule for replacement intervals and section Service Kits for part number information.

Roto-Inject Fluid

Atlas Copco’s Roto-Inject Fluid is a specially developed lubricant for use in single stage oil-injected screw compressors. Its specific composition keeps the compressor in excellent condition. Roto-Inject Fluid can be used for compressors operating at ambient temperatures between 0 ˚C (32 ˚F) and 40 ˚C (104 ˚F). If the compressor is regularly operating in ambient temperatures between 40 °C and 46 °C (115 °F), oil lifetime is reduced significantly. In such case it is recommended to use Roto-Xtend Duty Fluid.

Roto-Xtend Duty Fluid

Atlas Copco’s Roto-Xtend Duty Fluid is a high-quality synthetic lubricant for oil-injected screw compressors which keeps the compressor in excellent condition. Because of its excellent oxidation stability, Roto-Xtend

Duty Fluid can be used for compressors operating at ambient temperatures between 0 ˚C (32 ˚F) and 46 ˚C

(115 ˚F).

Roto-Xtend Duty Fluid is the standard oil for compressors equipped with freeze protection.

Roto-Foodgrade Fluid

Special oil, delivered as an option.

Atlas Copco’s Roto-Foodgrade fluid is a unique high-quality synthetic lubricant, specially created for oilinjected screw compressors that provide air for the food industry. This lubricant keeps the compressor in excellent condition. Roto-Foodgrade Fluid can be used for compressors operating at ambient temperatures between 0 ˚C (32 ˚F) and 40 ˚C (104 ˚F).

8.3

Storage after installation

Procedure

Run the compressor, e.g. twice a week, until warm. Load and unload the compressor a few times.

If the compressor is going to be stored without running from time to time, protective measures must be taken. Consult Atlas Copco.

146 2920 7090 51

Instruction book

8.4

Service kits

Service kits

For overhauling and for preventive maintenance, a wide range of service kits is available. Service kits comprise all parts required for servicing the component and offer the benefits of genuine Atlas Copco parts while keeping the maintenance budget low.

Also a full range of extensively tested lubricants, suitable for your specific needs is available to keep the compressor in excellent condition.

Consult the Spare Parts List for part numbers.

8.5

Disposal of used material

Used filters or any other used material (e.g. desiccant, lubricants, cleaning rags, machine parts, etc.) must be disposed of in an environmentally friendly and safe manner, and in line with the local recommendations and environmental legislation.

2920 7090 51 147

Instruction book

9 Adjustments and servicing procedures

9.1

Drive motor

General

Keep the outside of the electric motor clean for efficient cooling. If necessary, remove dust with a brush and/ or compressed air jet.

Bearing maintenance

The motor bearings are greased for life.

9.2

Air filter

Location of air filter

Air filter

Recommendations

1. Never remove the element while the compressor is running.

2. For minimum downtime, replace the dirty element by a new one.

3. Discard the element when damaged.

Procedure

1. Stop the compressor. Switch off the voltage.

2. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If necessary, clean the cover.

3. Fit the new element and the cover.

4. Reset the air filter service warning.

For compressors equipped with an Elektronikon® regulator, see section

Service warning

.

For compressors equipped with an Elektronikon® Graphic regulator, see section

Service menu

.

148 2920 7090 51

Instruction book

9.3

Oil and oil filter change

Warning

The operator must apply all relevant

Safety precautions

.

Procedure

Oil system components

1. Run the compressor until warm. Stop the compressor. Close the air outlet valve and switch off the voltage.

Depressurise the compressor by opening manual drain valve(s) (Dm, Dm1). Wait a few minutes and depressurise the air receiver/oil (AR) tank by unscrewing oil filler plug (FC) just one turn to permit any pressure in the system to escape.

2. Drain the oil by opening valve (OD).

3. Collect the oil and deliver it to the local collection service. Refit and tighten the drain and vent plugs after draining.

4. Remove the oil filter (OF). Clean the seat on the manifold. Oil the gasket of the new filter and screw it into place. Tighten firmly by hand.

5. Remove filler plug (FC).

Fill the oil tank (OT) with oil until the level reaches the middle of sight-glass (Gl).

Take care that no dirt drops into the system. Refit and tighten filler plug (FC).

6. Run the compressor loaded for a few minutes. Stop the compressor and wait a few minutes to allow the oil to settle.

7. Depressurise the system by unscrewing filler plug (FC) just one turn to permit any pressure in the system to escape. Remove the plug.

2920 7090 51 149

Instruction book

Add oil until the sight-glass (Gl) is 3/4 full.

Tighten the filler plug.

8. Reset the service warning after carrying out all service actions in the relevant Service Plan:

For compressors with Elektronikon® controller, see section

Calling up/resetting the service timer .

For compressors with Elektronikon® Graphic controller, see section Service menu

.

9.4

Oil separator change

Warning

The operator must apply all relevant

Safety precautions

.

Procedure

150

Oil system components

1. Run the compressor until warm. Stop the compressor, close the air outlet valve and switch off the voltage.

Wait a few minutes and depressurise by unscrewing oil filler plug (FC) just one turn to permit any pressure in the system to escape.

2. Wait 5 minutes and remove the oil separator (OS). Clean the seat on the manifold. Oil the gasket of the new separator and screw it into place. Tighten firmly by hand.

3. Remove filler plug (FC).

Fill the oil tank (OT) with oil until the level reaches the middle of sight-glass (Gl).

Take care that no dirt drops into the system. Refit and tighten filler plug (FC).

4. Reset the service timer:

2920 7090 51

Instruction book

For compressors equipped with an Elektronikon® regulator, see section

Service warning

.

For compressors equipped with an Elektronikon® Graphic regulator, see section

Service menu

.

9.5

Coolers

General

Keep the coolers clean to maintain their efficiency.

Instructions for air-cooled compressors

• Stop the compressor, close the air outlet valve and switch off the voltage.

• Cover all parts under the coolers.

• Remove any dirt from the coolers with a fibre brush. Never use a wire brush or metal objects.

• Next, clean with an air jet in the reverse direction to normal flow. Use low pressure air. If necessary, the pressure may be increased up to 6 bar(e) (87 psig).

• If it is necessary to wash the coolers with a cleaning agent, consult Atlas Copco.

9.6

Belt tensioning and replacement

2920 7090 51 151

Instruction book

Checking the belt tension

2

3

Step

1

4

Action

Stop the compressor, close the air outlet valve and switch off the voltage

Remove the front panel and the right panel.

The tension is correct when the force F needed to create a deflection of 5 mm (0.2 in) corresponds to the data in the table below.

Refit the bodywork panels.

Model

GA 5

GA 7

GA 11

New belt

F

N

18.2

18.2

21.2

lbf

5.1

5.1

6.1

Frequency

Hz

105

105

115

Used belt

F

N

12.6

12.6

14.2

lbf

3.6

3.6

4.0

Frequency

Hz

86

86

94

Adjusting the belt tension

6

7

4

5

2

3

Step

1

Action

Stop the compressor, close the air outlet valve and switch off the voltage.

Remove the front panel and the right panel.

Loosen bolts (2) by one turn.

Adjust the belt tension by turning nuts (1).

The tension is correct when the force F needed to create a deflection of 5 mm (0.2 in) corresponds to the data in the table above.

Tighten bolts (2).

Refit the bodywork panels.

Replacing the belts

6

7

4

5

2

3

Step

1

The belts must always be replaced as a set, even if only one of the belts is worn. Only use genuine Atlas Copco belts.

Action

Stop the compressor, close the air outlet valve and switch off the voltage.

Remove the front panel and the right panel.

Loosen bolts (2) by one turn.

Release the belt tension by loosening nuts (1).

Remove the belts.

Install the new belts.

Tension the belts as described above.

152 2920 7090 51

Instruction book

Step

8

9

Action

Refit the bodywork panels.

Check the belt tension after 50 running hours and adjust if necessary.

9.7

Safety valves

Location of safety valve

Safety valve on oil separator vessel

2920 7090 51

Safety valve on oil separator vessel

153

Instruction book

Safety valve on compressed air vessel

Testing

Before removing the valve, depressurise the compressor.

See section Problem solving.

Valve (SV) can be tested on a separate air line. If the valve does not open at the set pressure stamped on the valve, it needs to be replaced.

Valve (SV1) is fitted on tank-mounted versions. The valve can be tested on a separate air line. If the valve does not open at the set pressure stamped on the valve, it needs to be replaced.

Warning

No adjustments are allowed. Never run the compressor without safety valve.

9.8

Dryer maintenance instructions

Safety precautions

Refrigeration dryers of ID type contain refrigerant HFC.

When handling refrigerant, all applicable

safety precautions must be observed. Please be specifically

aware of the following points:

• Contact of refrigerant with the skin will cause freezing. Special gloves must be worn. If contacted with the skin, the skin should be rinsed with water. On no account may clothing be removed.

• Fluid refrigerant will also cause freezing of the eyes; always wear safety glasses.

• Refrigerant is harmful. Do not inhale refrigerant vapours. Check that the working area is adequately ventilated.

Be aware that internal elements such as the pipes can reach a temperature of 110˚C (230˚F). Therefore, wait until the dryer has cooled down before removing the panels.

Before starting any maintenance or repair work, switch off the voltage and close the air inlet and outlet valves.

154 2920 7090 51

Instruction book

Local legislation

Local legislation may stipulate that:

• Work on the refrigerant circuit of the cooling dryer or on any equipment which influences its function must be undertaken by an authorised control body.

• The installation should be checked once a year by an authorised control body.

General

For all references see section Introduction.

The following remarks should be kept in mind:

• Keep the dryer clean.

• Brush or blow off the finned surface of condenser monthly.

• Switch off the voltage and close the air outlet valve.

• Remove the panel where the condenser is situated (see the picture below).

• Clean the condenser fins with compressed air. Do not use water or solvents.

• Close the panel.

• Inspect and clean the electronic condensate drain monthly.

• Functioning of the drains can be checked by pushing the TEST button of the drain.

• Cleaning of the drain filter can be done by opening the manual drain valve during a few seconds.

2920 7090 51 155

Instruction book

10 Problem solving

Warning

Before carrying out any maintenance, repair work or adjustment, press the stop button, wait until the compressor has stopped, press the emergency stop button and switch off the voltage. Close the air outlet valve and lock it if necessary.

If provided, open the manual condensate drain valves. Depressurise the compressor by opening the oil filler plug one turn.

For location of components, see sections:

Introduction

, Condensate system and

Initial start-up

.

Open and lock the isolating switch.

The operator must apply all relevant

Safety precautions

.

Compressor

On compressors equipped with an Elektronikon® controller, if the alarm LED is lit or flashes, consult sections

Shutdown warning and following

Condition

Compressor starts running, but does not load after a delay time

Fault

Solenoid valve out of order

Remedy

Replace valve

Inlet valve stuck in closed position Have valve checked

Leak in control air flexibles Replace leaking flexible

Minimum pressure valve leaking

(when net is depressurised)

Have valve checked

Condition

Compressor does not unload, safety valve blows

Fault

Solenoid valve out of order

Inlet valve does not close

Remedy

Replace valve

Have valve checked

Condition

Condensate is not discharged from condensate separator during loaded operation

Fault

Discharge flexible clogged

Remedy

Check and correct as necessary

Automatic drain malfunctioning Disassemble, clean and check

Condition

Compressor air output or pressure below normal

Fault

Air consumption exceeds air delivery of compressor

Choked air filter element

Solenoid valve malfunctioning

Leak in control air flexibles

Inlet valve does not fully open

Oil separator clogged

Remedy

Check equipment connected

Replace filter element

Replace valve

Replace leaking flexibles

Have valve checked

Have element replaced

156 2920 7090 51

Instruction book

Condition Fault

Air leakage

Remedy

Have leaks repaired

Safety valve leaking Have valve replaced

Compressor element out of order Consult Atlas Copco

Condition

Excessive oil consumption; oil carry-over through discharge line

Condition Fault Remedy

Safety valve blows after loading Inlet valve malfunctioning

Minimum pressure valve malfunctioning

Have valve checked

Have valve checked

Safety valve out of order Have valve replaced

Compressor element out of order Consult Atlas Copco

Oil separator element clogged Have element replaced

Condition

Compressor element outlet temperature or delivery air temperature above normal

Fault

Oil level too high

Incorrect oil causing foam

Oil separator defective

Scavenge line clogged

Fault

Oil level too low

Remedy

Check for overfilling. Release pressure and drain oil to correct level

Change to correct oil

Have element checked.

Replace if necessary.

Check and remedy

Remedy

Check and correct

On air-cooled compressors, insufficient cooling air or cooling air temperature too high

Check for cooling air restriction or improve ventilation of the compressor room. Avoid recirculation of cooling air. If installed, check capacity of compressor room fan

Oil cooler clogged

Thermostatic bypass valve malfunctioning

Air cooler clogged

Clean cooler

Have valve tested

Clean cooler

Compressor element out of order Consult Atlas Copco Customer

Centre

Oil filter clogged Replace

Dryer

For all references hereafter, consult section

Air dryer .

2920 7090 51 157

158

Instruction book

1

5

3

2

4

Condition

Pressure dewpoint too high

Fault Remedy

Air inlet temperature too high Check and correct; if necessary, clean the aftercooler of the compressor

Ambient temperature too high Check and correct; if necessary, draw cooling air via a duct from a cooler place or relocate the compressor

Shortage of refrigerant

Refrigerant compressor (M1) does not run

Have circuit checked for leaks and recharged

See 3

Evaporator pressure too high See 5

Condenser pressure too high See 2

Fan control switch out of order Replace Condenser pressure too high or too low

Compressor stops or does not start

Electronic condensate drain remains inoperative

Condensate trap continuously discharges air and water

Evaporator pressure is too high or too low at unload

Fan blades or fan motor out of order

Check fan/fan motor

Ambient temperature too high Check and correct; if necessary, draw cooling air via a duct from a cooler place or relocate the compressor

Condenser externally clogged Clean condenser

Electric power supply to compressor is interrupted

Check and correct as necessary

Thermal protection of refrigerant compressor motor has tripped

Electronic drain system clogged

Automatic drain out of order Have system checked. If necessary, replace the automatic drain.

Hot gas bypass valve incorrectly set or out of order

Have hot gas bypass valve adjusted

Condenser pressure too high or too low

Shortage of refrigerant

Motor will restart when motor windings have cooled down

Have system inspected

Clean the filter of the automatic drain by opening the manual drain valve.

Check functioning of the drain by pushing the test button.

See 2

Have circuit checked for leaks and recharged

2920 7090 51

Instruction book

11 Technical data

11.1 Readings on display

Elektronikon

Control panel of the Elektronikon® controller

Control panel of the Elektronikon® Graphic controller

Important

The readings mentioned below are valid under the reference conditions (see section

Reference conditions and limitations

).

Reference

Air outlet pressure

Compressor element outlet temperature

Dewpoint

Reading

Modulates between programmed unloading and loading pressures.

Approx. 60 ˚C (108 ˚F) above cooling air temperature.

See section

Compressor data

2920 7090 51 159

Instruction book

11.2 Electric cable size

Important warning

The compressor is delivered with 3 m (10 ft.) cable and cable gland. This cable gland is necessary to ensure the protection degree of the electric cubicle and to protect its components from dust from the environment.

• The voltage on the compressor terminals must not deviate more than 10% of the nominal voltage.

It is however highly recommended to keep the voltage drop over the supply cables at nominal current below 5% of the nominal voltage (IEC 60204-1). If cables are grouped together with other power cables, it may be necessary to use cables of a larger size than those calculated for the standard operating conditions.

• Use the original cable entry. See section

Dimension drawings.

Local regulations remain applicable if they are stricter than the values proposed below.

IEC versions

For

IEC

designed control panels, the below suggested

cable sections

are calculated according to 60364-5-52 electrical installations of buildings, part 5: selection and erection equipment, section 52: current-carrying capacities in wiring systems.

Standard conditions refer to

loose copper conductors or multicore cable with 70˚C PVC insulation in free air or on open cable trays (installation method C) at 30˚C ambient temperature and operating at nominal voltage. The cables may not be grouped with other power circuits or cables.

Worst case conditions refer to

loose copper conductors or multicore cable with 70˚C PVC insulation, but with ambient temperature above 30˚C (86 ˚F), cables in closed raceway, conduit or trunking system

(installation method B2), or with cables grouped with other cables.

160

Fuse calculations for IEC

are done according to 60364-4-43 electrical installations of buildings, part 4: protection for safety- section 43: protection against overcurrent. Fuse sizes are calculated in order to protect the cable against short circuit. Fuse type aM is recommended but gG/gL is also allowed.

2920 7090 51

Instruction book

UL/cUL versions

For

UL

designed industrial control panels, calculations for

cable sections and fuses

are done according to

UL508a (Industrial control panels).

For

cUL

, calculations for

cable sections and fuses

are done according to CSA22.2 (Canadian electrical code).

Standard conditions:

maximum 3 copper conductors in raceway or cable with 85-90˚C (185-194 ˚F) insulation at ambient temperature 30 ˚C (86 ˚F), operating at nominal voltage; cables not grouped with other cables.

Worst case conditions:

ambient temperature > 30 ˚C (86 ˚F), max. 3 copper conductors in raceway or cable with 85-90 ˚C (185-194 ˚F) insulation at 46 ˚C (115 ˚F) ambient temperature and operating at nominal voltage.

Cables grouped with other cables.

Fuse size is the maximum fuse size in order to protect the motor against short circuit. For cUL fuse HRC form

II, for UL fuse class RK5.

If the local conditions are more severe then the described standard conditions, the cables and fuses for worst case conditions should be used.

Cable size

Type

GA 7

GA 7

GA 7

GA 7

GA 11

GA 11

GA 11

GA 11

GA 11

GA 11

GA 11

GA 5

GA 5

GA 7

GA 7

GA 7

GA 5

GA 5

GA 5

GA 5

GA 5

V

400

400 + N

460

500

200

230

380

400

400 + N

460

500

460

500

200

230

380

200

230

380

400

400 + N

Approval

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

4 x 6

4 x 6

5 x 6

4 x 6

4 x 6

4 x 2.5

5 x 2.5

4 x 2.5

4 x 2.5

4 x 16

4 x 10

Recommended wire section (mm

2

)

Pack

4 x 6

Full Feature

4 x 10

4 x 6

4 x 2.5

4 x 2.5

4 x 2.5

4 x 10

4 x 4

4 x 4

5 x 4

4 x 2.5

4 x 2.5

4 x 10

4 x 10

4 x 2.5

4 x 4

4 x 4

4 x 10

4 x 10

4 x 4

4 x 4

5 x 4

4 x 4

4 x 4

4 x 16

4 x 16

4 x 10

4 x 10

5 x 10

4 x 10

4 x 10

2920 7090 51 161

Type

GA 5

GA 5

GA 5

GA 7

GA 7

GA 7

GA 11

GA 11

GA 11

V

200

200/230/460

575

200

200/230/460

575

200

200/230/460

575

Approval

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

Instruction book

4

4

8

8

12

8

8

Recommended wire section (AWG)

Pack Full Feature

14

8

8

12

10

6

6

10

4

4

10

11.3 Settings for overload relay and fuses

Overload relay and fuses

Type V Approval

GA 7

GA 7

GA 7

GA 7

GA 7

GA 7

GA 11

GA 11

GA 11

GA 11

GA 5

GA 5

GA 5

GA 5

GA 5

GA 5

GA 5

GA 7

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

IEC

200

230

380

400

230

380

400

400 + N

460

500

200

230

380

400

400 + N

460

500

200

40

25

25

25

25

20

63

63

32

32

16

50

20

20

20

20

MAX

40

28

36

21

21

21

19

19

60

52

30

30

Overload Relay

Pack

Setting (A) MAX

32 40

28 40

14

42

16

16

16

15

20

50

25

25

25

20

50

32

32

32

25

25

80

63

40

40

41

24

24

26

21

20

68

59

34

34

Overload Relay

Full Feature

Setting (A)

39

32

16

48

19

19

21

17

162 2920 7090 51

Instruction book

Type

GA 11

GA 11

GA 11

Type

GA 5

GA 5

GA 5

GA 7

GA 7

GA 7

GA 11

GA 11

GA 11

V

400 + N

460

500

V

200

200/230/460

575

200

200/230/460

575

200

200/230/460

575

Approval

IEC

IEC

IEC

MAX

32

32

25

Overload Relay

Pack

Setting (A) MAX

30 40

26

24

32

32

Overload Relay

Full Feature

Setting (A)

37

30

27

Approval

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

CSA/UL

Overload setting (FM1)

(A)

34.5

33/30/15

12

44.5

43/39/19

15.5

63.5

61/55/27.5

22

Fuse rating (A)

Class J or RK

Pack

40

40/40/20

15

50

60/60/30

20

80

80/80/40

30

Full Feature

45

40/40/20

20

60

60/60/30

25

80

80/80/40

35

11.4 Dryer switches

General

The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.

Do not alter the setting of any of the devices.

11.5 Reference conditions and limitations

Reference conditions

Air inlet pressure (absolute)

Air inlet pressure (absolute)

Air inlet temperature

Air inlet temperature

Relative humidity

Working pressure bar psi

˚C

˚F

%

1

14.5

20

68

0

See section Compressor data

2920 7090 51 163

Instruction book

Limits

Maximum working pressure

Minimum working pressure

Minimum working pressure

Maximum air inlet temperature

Maximum air inlet temperature

Minimum air inlet temperature

Minimum air inlet temperature bar(e) psig

˚C

˚F

˚C

˚F

See section Compressor data

5.5

80

46

115

0

32

11.6 Compressor data

Reference conditions

All data specified below are valid at reference conditions, see section Reference conditions and limitations

.

GA 5

Frequency

Maximum

(unloading) pressure, units without dryer

Maximum

(unloading) pressure, units without dryer

Maximum

(unloading) pressure, Full-

Feature units

Maximum

(unloading) pressure, Full-

Feature units

Nominal working pressure

Nominal working pressure

Pressure drop over dryer, Full-Feature units

Units 7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi

Hz 50 50 50 50 60 60 60 60 bar(e) 7.5

8.5

10 13 7.4

9.1

10.8

12.5

psig 109 bar(e) 7.25

psig 105 bar(e) 7 psig 102 bar(e) 0.10

123

8.25

120

8

116

0.08

145

9.75

141

9.5

138

0.05

189

12.75

185

12.5

181

0.02

107

7.15

104

6.9

100

0.10

132

8.85

128

8.6

125

0.08

157

10.55

153

10.3

150

0.05

181

12.25

178

12

175

0.02

164 2920 7090 51

Instruction book

Pressure drop over dryer, Full-Feature units

Units

psig

Motor shaft speed r/min

Thermostatic valve

(closing/opening temperature)

˚C

Thermostatic valve

(closing/opening temperature)

˚F

7.5 bar 8.5 bar 10 bar

1.45

2900

71/84

1.16

2900

71/84

0.72

2900

71/84

13 bar

0.3

2900

71/84

100 psi 125 psi 150 psi 175 psi

1.45

3510

71/84

1.16

3510

71/84

0.72

3510

71/84

0.3

3510

71/84

160/183 160/183 160/183 160/183 160/183 160/183 160/183 160/183

Temperature of air leaving outlet valve

(approx.)

Temperature of air leaving outlet valve

(approx.)

Temperature of air leaving outlet valve

(approx.), Full-

Feature units

Temperature of air leaving outlet valve

(approx.), Full-

Feature units

˚C

˚F

˚C

˚F

Dew-point, Full-

Feature units

Dew-point, Full-

Feature units

˚C

˚F

Nominal motor rating kW

35

95

24

75

3

37.4

35

95

24

75

3

37.4

35

95

24

75

3

37.4

35

95

24

75

3

37.4

35

95

24

75

3

37.4

35

95

24

75

3

37.4

35

95

24

75

3

37.4

35

95

24

75

3

37.4

5

6.7

0.4

5

6.7

0.4

5

6.7

0.4

5

6.7

0.4

5

6.7

0.4

5

6.7

0.4

5

6.7

0.4

5

6.7

0.4

Nominal motor rating hp

Power consumption dryer at full load, Full-

Feature units kW hp Power consumption dryer at full load, Full-

Feature units

Power consumption dryer at no load, Full-

Feature units kW hp Power consumption dryer at no load, Full-

Feature units

Refrigerant type,

Full-Feature units

Refrigerant quantity,

Full-Feature units kg

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

0.54

0.3

0.4

R134a

0.44

Refrigerant quantity,

Full-Feature units

Oil capacity l lb 0.97

3.6

0.97

3.6

0.97

3.6

0.97

3.6

0.97

3.6

0.97

3.6

0.97

3.6

0.97

3.6

2920 7090 51 165

Instruction book

Oil capacity

Oil capacity

Sound pressure level

(according to ISO

2151 (2004))

Units 7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi

US gal 0.95

0.95

0.95

0.95

0.95

0.95

0.95

0.95

Imp gal 0.79

dB(A) 60

0.79

60

0.79

60

0.79

60

0.79

60

0.79

60

0.79

60

0.79

60

GA 7

Frequency

Maximum

(unloading) pressure, units without dryer

Maximum

(unloading) pressure, units without dryer

Maximum

(unloading) pressure, Full-

Feature units

Maximum

(unloading) pressure, Full-

Feature units

Nominal working pressure

Nominal working pressure

Units

Hz bar(e) psig bar(e) psig bar(e) psig

7.5 bar 8.5 bar 10 bar

50

7.5

109

7.25

105

7

102

50

8.5

123

8.25

120

8

116

50

10

145

9.75

141

9.5

138

13 bar

50

13

189

12.75

185

12.5

181

100 psi 125 psi 150 psi 175 psi

60

7.4

107

7.15

104

6.9

100

60

9.1

132

8.85

128

8.6

125

60

10.8

157

10.55

153

10.3

150

60

12.5

181

12.25

178

12

175

Pressure drop over dryer, Full-Feature units

Pressure drop over dryer, Full-Feature units bar(e) psig

Motor shaft speed r/min

Thermostatic valve

(closing/opening temperature)

˚C

˚F Thermostatic valve

(closing/opening temperature)

Temperature of air leaving outlet valve

(approx.)

˚C

0.12

1.74

2940

71/84

2940

71/84

2940

71/84

2940

71/84

3540

71/84

3540

71/84

3540

71/84

3540

71/84

160/183 160/183 160/183 160/183 160/183 160/183 160/183 160/183

34

0.1

1.45

34

0.08

1.16

34

0.05

0.72

34

0.12

1.74

34

0.1

1.45

34

0.08

1.16

34

0.05

0.72

34

166 2920 7090 51

Instruction book

Temperature of air leaving outlet valve

(approx.)

Temperature of air leaving outlet valve

(approx.), Full-

Feature units

Temperature of air leaving outlet valve

(approx.), Full-

Feature units

Dew-point, Full-

Feature units

Units

˚F

˚C

˚F

˚C

Dew-point, Full-

Feature units

˚F

Nominal motor rating kW

Nominal motor rating hp kW Power consumption dryer at full load, Full-

Feature units

Power consumption dryer at full load, Full-

Feature units hp

Power consumption dryer at no load, Full-

Feature units

Power consumption dryer at no load, Full-

Feature units kW hp

7.5 bar 8.5 bar 10 bar

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

13 bar

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

100 psi 125 psi 150 psi 175 psi

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a

93

28

82

3

37.4

7

9.4

0.5

0.67

0.4

0.54

R134a Refrigerant type,

Full-Feature units

Refrigerant quantity,

Full-Feature units

Refrigerant quantity,

Full-Feature units

Oil capacity

Oil capacity

Oil capacity

Sound pressure level

(according to ISO

2151 (2004)) l kg lb

US gal dB(A)

0.48

1.05

3.7

0.97

Imp gal 0.81

61

0.48

1.05

3.7

0.97

0.81

61

0.48

1.05

3.7

0.97

0.81

61

0.48

1.05

3.7

0.97

0.81

61

0.44

1.05

3.7

0.97

0.81

61

0.44

1.05

3.7

0.97

0.81

61

0.44

1.05

3.7

0.97

0.81

61

0.44

1.05

3.7

0.97

0.81

61

GA 11

Frequency

Units 7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi

Hz 50 50 50 50 60 60 60 60

2920 7090 51 167

168

Instruction book

Maximum

(unloading) pressure, units without dryer

Maximum

(unloading) pressure, units without dryer

Maximum

(unloading) pressure, Full-

Feature units

Maximum

(unloading) pressure, Full-

Feature units

Units

bar(e)

7.5 bar 8.5 bar 10 bar

7.5

8.5

10

13 bar

13

100 psi 125 psi 150 psi 175 psi

7.4

9.1

10.8

12.5

181

12.25

178

Nominal working pressure

Nominal working pressure

Pressure drop over dryer, Full-Feature units

Pressure drop over dryer, Full-Feature units bar(e) psig bar(e) psig

Motor shaft speed r/min

Thermostatic valve

(closing/opening temperature)

˚C

Thermostatic valve

(closing/opening temperature)

˚F

7

102

0.12

1.74

2935

71/84

8

116

0.08

1.16

2935

71/84

9.5

138

0.04

0.6

2935

71/84

12.5

181

0.02

0.3

2935

71/84

6.9

100

0.12

1.74

3535

71/84

8.6

125

0.08

1.16

3535

71/84

10.3

150

0.04

0.6

3535

71/84

12

175

0.02

0.3

3535

71/84

160/183 160/183 160/183 160/183 160/183 160/183 160/183 160/183

Temperature of air leaving outlet valve

(approx.)

Temperature of air leaving outlet valve

(approx.)

Temperature of air leaving outlet valve

(approx.), Full-

Feature units

Temperature of air leaving outlet valve

(approx.), Full-

Feature units

Dew-point, Full-

Feature units psig bar(e) psig

˚C

˚F

˚C

˚F

˚C

109

7.25

105

37

99

30

86

3

123

8.25

120

37

99

30

86

3

145

9.75

141

37

99

30

86

3

189

12.75

185

37

99

30

86

3

107

7.15

104

37

99

30

86

3

132

8.85

128

37

99

30

86

3

157

10.55

153

37

99

30

86

3

37

99

30

86

3

2920 7090 51

Instruction book

Dew-point, Full-

Feature units

Units

˚F

Nominal motor rating kW

Nominal motor rating hp

Power consumption dryer at full load, Full-

Feature units kW

7.5 bar 8.5 bar 10 bar

37.4

11

14.75

0.7

37.4

11

14.75

0.7

37.4

11

14.75

0.7

13 bar

37.4

11

14.75

0.7

100 psi 125 psi 150 psi 175 psi

37.4

11

14.75

0.7

37.4

11

14.75

0.7

37.4

11

14.75

0.7

37.4

11

14.75

0.7

hp 0.94

0.94

0.94

0.94

0.94

0.94

0.94

0.94

Power consumption dryer at full load, Full-

Feature units

Power consumption dryer at no load, Full-

Feature units

Power consumption dryer at no load, Full-

Feature units

Refrigerant type,

Full-Feature units

Refrigerant quantity,

Full-Feature units

Refrigerant quantity,

Full-Feature units

Oil capacity kW hp kg lb

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

0.5

0.67

R134a

0.37

0.81

Oil capacity

Oil capacity

Sound pressure level

(according to ISO

2151 (2004)) l 5.1

US gal 1.35

Imp gal 1.12

dB(A) 62

5.1

1.35

1.12

62

5.1

1.35

1.12

62

5.1

1.35

1.12

62

5.1

1.35

1.12

62

5.1

1.35

1.12

62

5.1

1.35

1.12

62

5.1

1.35

1.12

62

11.7 Technical data Elektronikon® controller

General

Parameter

Supply voltage

Type of protection

Ambient and temperature conditions

Temperature range

• Operating

• Storage

Permissible humidity

Noise emission

Value

24 V AC /16 VA 50/60Hz (+40%/-30%)

24 V DC/0.7 A

IP54 (front)

IP21 (back)

IEC60068-2

• -10°C…..+60°C

• -30°C…..+70°C

Relative humidity 90%

No condensation

IEC61000-6-3

2920 7090 51 169

Noise immunity

Mounting

Digital outputs

Parameter

Number of outputs

Type

Rated voltage AC

Rated voltage DC

Digital inputs

Parameter

Number of inputs

Supply by controller

Supply protection

Input protection

Analog inputs

Parameter

Pressure inputs

Temperature inputs

Instruction book

IEC61000-6-2

Cabinet door

Value

6 (Elektronikon® controller — p.n. 1900 5200 00 …. 1900 5200

09)

9 ( Elektronikon® Graphic controller — p.n. 1900 5200 10 …. 1900

5200 19)

Relay (voltage free contacts)

250 V AC / 10 A max.

30 V DC / 10 A max.

Value

4 (Elektronikon® controller — p.n. 1900 5200 00 …. 1900 5200

09)

10 (Elektronikon® Graphic controller — p.n. 1900 5200 10 ….

1900 5200 19)

24 V DC

Short circuit protected to ground

Not isolated

Value

1 (Elektronikon® controller — p.n. 1900 5200 00 …. 1900 5200

09)

2 (Elektronikon® Graphic controller — p.n. 1900 5200 10 …. 1900

5200 19)

3 (Elektronikon® controller — p.n. 1900 5200 00 …. 1900 5200

09)

5 (Elektronikon® Graphic controller — p.n. 1900 5200 10 …. 1900

5200 19)

170 2920 7090 51

Instruction book

12 Instructions for use

Oil separator vessel

1

2

3

6

7

4

5

This vessel can contain pressurised air; this can be potentially dangerous if the equipment is misused.

This vessel must only be used as a compressed air/oil separator tank and must be operated within the limits specified on the data plate.

No alterations must be made to this vessel by welding, drilling or other mechanical methods without the written permission of the manufacturer.

The pressure and temperature of this vessel must be clearly indicated.

The safety valve must correspond with pressure surges of 1.1 times the maximum allowable operating pressure. It should guarantee that the pressure will not permanently exceed the maximum allowable operating pressure of the vessel.

Use only oil as specified by the manufacturer.

There is no intrinsic need for service inspection of the oil separator vessel when used within the design limits for its intended application. Nevertheless, in case of misuse of the units (very low oil temperature or long interval of shut down) a certain amount of condensate can gather in the oil separator vessel which must be properly drained. To do so, disconnect the unit from the power line, wait till it is cooled down and depressurised and drain the water by the oil drain valve, positioned at the bottom side of the oil separator vessel.

Local legislation may require an internal inspection.

Air receiver (on tank-mounted units)

1

2

3

4

5

6

Corrosion must be prevented: depending on the conditions of use, condensate may accumulate inside the tank and must be drained every day.

This may be done manually, by opening the drain valve, or by means of the automatic drain, if fitted to the tank.

Nevertheless, a weekly check of correct functioning of the automatic valve is needed. This has to be done by opening the manual drain valve and check for condensate.

Periodical service inspection of the air receiver is needed, as internal corrosion can reduce the steel wall thickness with the consequent risk of bursting. Local rules need to be respected, if applicable. The use of the air receiver is forbidden once the wall thickness reaches the minimum value as indicated in the service manual of the air receiver (part of the documentation delivered with the unit).

Lifetime of the air receiver mainly depends on the working environment. Avoid installing the compressor in a dirty and corrosive environment, as this can reduce the vessel lifetime dramatically.

Do not anchor the vessel or attached components directly to the ground or fixed structures.

Fit the pressure vessel with vibration dampers to avoid possible fatigue failure caused by vibration of the vessel during use.

Use the vessel within the pressure and temperature limits stated on the nameplate and the testing report.

No alterations must be made to this vessel by welding, drilling or other mechanical methods.

2920 7090 51 171

Instruction book

13 Guidelines for inspection

Guidelines

On the Declaration of Conformity / Declaration by the Manufacturer, the harmonised and/or other standards that have been used for the design are shown and/or referred to.

The Declaration of Conformity / Declaration by the Manufacturer is part of the documentation that is supplied with this compressor.

Local legal requirements and/or use outside the limits and/or conditions as specified by the manufacturer may require other inspection periods as mentioned below.

172 2920 7090 51

Instruction book

14 Pressure equipment directives

Components subject to 97/23/EC Pressure Equipment Directive

The following table contains the necessary information for the inspection of all pressure equipment of category

II and higher according to the Pressure Equipment Directive 97/23/EC and all pressure equipment according to the Simple Pressure Vessel Directive 87/404/EEC.

Compressor type

GA 5 up to GA 11

Part number

2202 8891 01

2202 8891 03

2202 8891 02

Description

Safety valve

Safety valve

Safety valve

PED Class

IV

IV

IV

Overall rating

The compressors conform to PED smaller than category I.

2920 7090 51 173

15 Declaration of conformity

Typical example of a Declaration of Conformity document

Instruction book

174 2920 7090 51

In order to be First in Mind-First in Choice® for all your quality compressed air needs, Atlas Copco delivers the products and services that help to increase your business’ efficiency and profitability.

Atlas Copco’s pursuit of innovation never ceases, driven by our need for reliability and efficiency. Always working with you, we are committed to providing you the customized quality air solution that is the driving force behind your business.

www.atlascopco.com

Безмасляные компрессоры

  • Компрессоры высокого давления GR

    322.8 kB, PDF

  • Винтовые компрессоры G110-250, G160VSD

    5 MB, PDF

  • Центробежные воздуходувки

    842.2 kB, PDF

  • Винтовые компрессоры ZR 300-900

    5 MB, PDF

  • Центробежные компрессоры ZH

    5.9 MB, PDF

  • Водозаполненные компрессоры AQ 15-55

    6.4 MB, PDF

  • Винтовые компрессоры GA90-160

    4.7 MB, PDF

  • Винтовые компрессоры GA160-315 VSD

    1 MB, PDF

  • Винтовые компрессоры ZR-ZT 55-90 (FF)

    5.7 MB, PDF

  • Винтовые компрессоры ZR/ZT 110-275

    5.8 MB, PDF

  • Винтовые компрессоры GA 355-500

    3.1 MB, PDF

  • Зубчатые компрессоры ZT15-22, ZR/ZT 30-45

    5.3 MB, PDF

  • Безмасляные спиральные компрессоры SF

    4.7 MB, PDF

  • Безмасляный поршневой компрессор LZ

    2.5 MB, PDF

Маслозаполненные компрессоры

  • Винтовые компрессоры G и GX

    2.4 MB, PDF

  • Винтовые компрессоры GA 7-75 VSD

    4 MB, PDF

  • Винтовые компрессоры GA 30-90 VSD

    5.1 MB, PDF

  • Винтовые компрессоры GA 7-37 VSD+

    46.8 MB, PDF

  • Промышленные поршневые компрессоры

    3.6 MB, PDF

  • Винтовые компрессоры G15-22, GA 15-26, GA 11-30 VSD

    4.5 MB, PDF

  • Винтовые компрессоры GA 37-110 VSD+

    69 MB, PDF

  • Винтовые компрессоры GA 7-110 VSD

    16 MB, PDF

Подготовка воздуха

  • Адсорбционные осушители BD-CD

    5.1 MB, PDF

  • Магистральные фильтры

    6.8 MB, PDF

  • Рефрижераторные осушители FD

    4 MB, PDF

  • Рефрижераторные осушители FX

    2.8 MB, PDF

Промышленные газы

  • Генераторы азота и кислорода

    3.1 MB, PDF

  1. Manuals
  2. Brands
  3. Atlas Copco Manuals
  4. Air Compressor
  5. GA7

Manuals and User Guides for Atlas Copco GA7. We have 3 Atlas Copco GA7 manuals available for free PDF download: Instruction Book, User Manual

Инструкция по эксплуатации для компрессора atlas ga7ff

Винтовой компрессор Atlas Copco GA 7 — 7.5

GA 7 – это винтовые компрессоры с воздушным охлаждением. Комплектуются всеми необходимыми патрубками и трубопроводами, автоматической системой слива конденсата, крепятся на собственной силовой раме.

Компрессор состоит из компрессорного элемента, электродвигателя, который полностью закрыт и принудительно охлаждается системой охлаждения, а также систем регулирования и контроля. Специальный звукоизолирующий корпус полностью закрывает компрессор, а также смонтированный внутри шкаф электроавтоматики с микропроцессорным модулем Elektronikon. В качестве опции возможна установка рефрижераторного осушителя, магистральных фильтров, а также установка компрессора на ресивер.

Версия FF: встроенный осушитель воздуха

Оборудован русифицированным микропроцессорным модулем Elictronikon Mk5 и встроенным в корпус рефрижераторным осушителем сжатого воздуха, обеспечивающий на выходе сухой сжатый воздух с температурой точкой росы +3°C. Такая компоновка «все в одном» снижаем потребность в площади при установке компрессора,обеспечивает единую точку подвода электроэнергии, компрессорная система приходит в собранном и протестированном виде. предусмотрены ручная и автоматическая система дренажа конденсата. Режим работы: нагрузка, холостой ход (разгрузка), временное отключение.

Версия PACK: без осушителя воздуха

Оборудован русифицированным микропроцессорным модулем Elictronikon Mk5. Рекомендуется для применения в производствах, где точка росы либо не регламентирована, либо где требования по точке росы значительно превосходят значение +3°C (в этом случае применяется совместно с осушителем адсорбционного и мембранного типа). Режим работы: нагрузка, холостой ход (разгрузка), временное отключение.

ОСОБЕННОСТИ И ПРЕИМУЩЕСТВА ВИНТОВЫХ КОМПРЕССОРОВ ATLAS COPCO GA 5-11

1 — Оптимизированный ременный привод:
Непревзойденная надежность на протяжении всего жизненного цикла благодаря технологичному ременному приводу, разработанному в соответствии с высочайшими промышленными стандартами.

2 — Проверенный временем винтовой элемент:

  • Компрессорный узел GA 5-11’s в комбинации с электродвигателем соответствующему стандарту IE3, улучшенным подшипникам и уплотнениям минимизирует расходы на эксплуатацию.
  • Сохраняет работоспособность при повышенной температуре воздуха в рабочем помещении (вплоть до 46°C) благодаря совершенному дизайну и расположению компонентов.
  • Параметр FAD (Free Air Delivery) улучшен на 8%, а потребление электроэнергии уменьшено на 7% благодаря оптимизированному расположению элементов и совершенному компрессорному элементу.

3 — Встроенные очистка и осушка сжатого воздуха

  • Защита потребляющего сжатый воздух оборудования во всех ситуациях: встроенный осушитель сжатого воздуха позволяет избежать как конденсации влаги, так и коррозии элементов пневмосистемы
  • Дополнительная экономия электроэнергии за счет применения электронного клапана сброса конденсата без потери давления сжатого воздуха.
  • Опциональные фильтры сжатого воздуха могут быть использованы для достижения качества сжатого воздуха, соответствующему 1 классу (фильтрация загрязнений Привод. Система охлаждения компрессора. Система смазки. Воздушная система. Шкаф управления. Система регулировки производительности. Модуль управления Elektronikon.

Самые злободневные вопросы по Atlas Copco и ответы на них

Мусор в компрессоре.
Да! Не пыль и даже не крупные частицы!
Бывают случаи выхода из строя компрессоров, по причине попадания в них крупного мусора, камней, щебня, палок.
Попадают в вентиляторы, крыльчатки, ремни, что снижает ресурс или может приводить к поломкам.
Внимание!

В инструкции по эксплуатации даны рекомендации по установке компрессора.
Помещение должно быть чистым. При заборе воздуха с улицы, где может присутствовать пух, листья, насекомые и т.д., рекомендуем
установить предварительный фильтр от пыли, листвы на приточную вентиляцию.

Если компрессор стоит в грязном помещении или цеху, то можно предварительный фильтр поставить на него, а на выброс сделать отвод воздуха,
чтобы исключить поппадание камней во внутрь оборудования.
От всех негативных факторов не убережешь оборудование, но можно их минимизировать и продлить срок службы оборудования.

Новый улучшенный контроллер Elektronikon MK5 Touch
Повилась новая модель блока управления винтовыми компрессорами Атлас Копко.
Сенсорный экран высокого разрешения (можно интуитивно нажимать на экран и устанавливать параметры)
Артикул: 1900520400 Elektronikon MK5 Touch
• Оптимизация энергоэффективности
• Встроенное подключение через SMARTLINK 2.0
• Повышенная защита машины
• Полная автоматизация
• Простая в использовании панель навигации со светодиодными значками

Основные рекомендации описаны в инструкции и частично продублированы в комиксе:
1. Компрессор устанавливаем на ровный пол
2. Оставляем пространство вокруг компрессора для проведения технического обслуживания
3. Поверхность должна быть ровной
4. Перед включением необходимо демонтировать транспортировочный крепеж
5. Должна быть защита кабеля
6. Ввод кабеля осуществить через гермоввод
7. Необходимо проконтролировать направления вращения электродвигателя и вентиляторов охлаждения
8. При сбросе конденсата, необходим разрыв
9. Правильная вентиляция небольших помещений, чтобы исключить перегрев
10. Если есть поплавковые конденсатоотводчики на фильтрах и присутствуют автоматические, требуется обеспечить сброс в магистраль без передавливания по давлению
11. Внимание! Часто встречается данная ошибка.
Необходимо подключаться в магистраль через колено, чтобы возможный конденсат со всего завода не устремлялся к компрессору.

Мы даем рекомендации перед поставкой оборудования, во время пусконаладочных работ и в процессе эксплуатации, чтобы Вам было комфортно работать и оборудование служило дольше.

Если происходит утечка компрессорного масла по валу винтового блока, то необходимо произвести замену уплотнения винтового блока (сальник).

1630218188 Втулка одевается на вал винтового блока. На валу винтового блока есть паз для уплотнительного кольца. Если данный паз отсутствует, то необходимо втулку посадить на вал используя Loctite 641.

На адсорбционных осушителях горячей регенерации термоизоляция является опцией для стандартных BD+ с точкой росы PDP -40C, для BD+ с точкой росы PDP -70C термоизоляция поставляется в составе опции -70С.

Термоизоляция повышает энергоэффективность системы и позволяет тем самым достигать более высокий уровень осушения сжатого воздуха.

На фотографии изображен корпус магистрального фильтра сжатого воздуха Атлас Копко, на котором написан артикул элемента, требующего замены.

Если изображения нет, то данный артикул дублируется на самом элементе фильтра. Если фильтр встроен в компрессорную установку, то по его серийному номеру на шильде можно запросить деталировку и посмотреть в ней, чтобы избежать ошибки

Во многих наборах лежит невзрачный фильтр электрошкафа. Фильтровальный материал похож на синтипон, но это не он. Если данный фильтр не менять, то в какой то момент начнет нарушаться вентиляция в электрошкафу, что снизит работу электрических модулей. Проникающие твердые частицы тоже не пойдет на пользу автоматам, контакторам и тиристорам в частотных преобразователях.
Меняйте данные фильтры по мере загрязнения!

Аварийная кнопка нужна для аварийного выключения!

На фотографии аварийная кнопка, которой на протяжении длительного времени выключали компрессор. Она расшаталась, перекрутилась и оборвался провод. Компрессор Атлас Копко перестал включаться. При таких нажатиях компрессорное оборудование может выйти из строя из-за не выполненной разгрузки перед выключением.

Это очень редкий случай на данных компрессорных установках.

В воздушном фильтре масло может быть по нескольким причинам.
Основные:
1) Забилась линия эвакуации масла с сепаратора или неисправен обратный клапан линии эвакуации масла.
Сепаратор переполняется маслом и в воздушную линию управления впускным клапаном попадает масло.
2)Неисправен клапан минимального давления и обратный клапан самого компрессора.
При выключении происходит обратное вращение или гидроудар, масло выбрасывается при разгрузке и попадает на воздушный фильтр.

Размышление является личным мнением автора и носит исключительно информационный характер.

Технологию применения спиральных блоков часто можно было увидеть в Японии в холодильных компрессорах, которые рассчитаны на работу исключительно в режиме периодической нагрузки.
Конструкция такого узла достаточно сложная и дорогая. Этот блок не может быть переделан или капитально отремонтирован, поэтому меняется целиком. Из-за короткого срока службы подшипников, срок службы спирального блока составляет всего 10 000 часов (бывает незначительно больше или меньше в зависимости от давления и условий эксплуатации).

Спиральный блок не позволяет достигать высокой производительности, поэтому он используется в небольших компрессорах мощностью от 1,5 до 15 кВт.
В самой большой модели SF15 устанавливается сразу четыре спиральных блока и четыре электромотора, что увеличивает стоимость капремонта, обслуживания и стоимость самого компрессора.

Чтобы производительность блока не падала в ходе эксплуатации из-за растущих зазоров между корпусом и спиралью, антифрикционные уплотнения для увеличения эффективности нужно своевременно менять. Чтобы снизить потери производительности, необходимо фильтровать всасываемый воздух. Установленные на входе воздушные фильтры отсеивают твердые частицы и замедляют износ уплотнений.

Atlas Copco является гарантом получения качественного изделия Заказчиком. OEM завод изготовитель не продает запасные части, которые делает для Atlas Copco.
Аналоги встречаются по размерам у многих заводов, но каждый раз можно получить разное качество (отсутствует контроль), что затрудняет прогнозирование проведения технического обслуживания.

Это является конфиденциальной информацией (производители могут меняться, но могут изготавливаться и на собственных заводах)
https://www.atlascopcogroup.com/en/about-us/brands

В некоторых винтовых компрессорных установках Атлас Копко на всасывающей линии есть индикатор загрязненности воздушного фильтра.

Если красная часть сервис-индикатора воздушного фильтра показывает полную выработку ресурса фильтра, замените элемент воздушного фильтра. Сбросьте сервис-индикатор, нажав на кнопку, расположенную на краю корпуса, а также переустановите настройки предупреждения о необходимости технического обслуживания.

Охлаждение винтового компрессора осуществляется или крыльчаткой основного электродвигателя или дополнительным электродвигателем с вентилятором, который устанавливается на радиатор.
Вентилятор охлаждения может располагаться вертикально или горизонтально. При перепадах температуры в цехах (охлаждение металлических поверхностей) на них из горячего воздуха выпадает конденсат. На этот конденсат садится пыль цементная, сахарная, земляная и т.д.

При правильном монтаже вентиляции данная ситуация не актуальна. Фильтрация воздуха охлаждения происходит на линиях приточного воздуха к компрессору или на приточном воздухе общеобменной вентиляции. Пыль не должна попадать с улицы сразу в компрессор.

Загрязнение лопостей крыльчатки охлаждения компрессора (неравномерного налипание грязи) — происходит дисбаланс и разрушение подшипников или посадочного места у электродвигателя охлаждения.

Обратите внимание на крыльчатку вентилятора охлаждения и если она грязная — проводите очистку, внесите данную процедуру в регламент ежедневного, еженедельного, ежемесячного обслуживания.

В компрессорных установках Атлас Копко электросхема расположена в электрическом отсеке.

На безмаслянных компрессорных установках SF есть подшипники, которые необходимо смазывать.
Есть регламент, который не рекомендуется нарушать. Необходимо по мере загрязнения производить замену воздушного фильтра и тогда компрессорная установка будет хорошо работать.

Необходимо по рекомендованному заводом изготовителем регламенту проводить техническое обслуживание винтового компрессора, чтобы все работало исправно.
Произвели замену фильтров, заменили масло и перебрали клапаны.
При эксплуатации оборудования без замены расходных материалов — увеличиваются риски выхода оборудования из строя.

Если при смене масляного фильтра или сепаратора, Вы видите элементы коррозии или эмульсию (воду в масле), то необходимо полностью сменить масло в системе и заменить расходные материалы.

Какие причины коррозии в винтовом компрессоре?

Основная причина появления коррозии — это вода.

В воздухе содержится вода, которая частично при сжатии внутри компрессора остается в масле.

Если масло разогрето, то вода уходит вместе с воздухом в трубопровод и на пневмооборудование.

После компрессора ставят осушители, которые воду из воздуха убирают.

Если масло не успевает прогреваться, а компрессор включается кратковременно, то внутри масляной системы накапливается вода. Уровень масла начинает расти. (Если открыть после простоя оборудования сливное отверстие, то пойдет или вода или оранжевая эмульсия).

В современных машинах блоки управления отслеживают такую работу и увеличивают время холостого хода, чтобы система успевала прогреваться. В моделях прошлых поколений необходимо давать машине прогреться.

Это можно сделать, сбросив кратковременно воздух в атмосферу или настроив холостой ход на больший интервал времени.

  1. Не правильно подобранное оборудование. В таком случае ставят (или надо было ставить) компрессор меньше по производительности, а ресиверов ставят больше.
  2. Снижение потребления. Меняется расход воздуха на предприятии по причине снижения производства или переходе на другую технологию. Компрессор становится переразмерянным.
  3. Используются не оригинальные запасные части и масла, бывают реакции, не стабильная работа.

Фильтр воздушный для тяжелых условий эксплуатации Атлас Копко можно встретить в винтовых компрессорных установках серии GA.
Как видно на фотографии — условия эксплуатации достаточно тяжелые.
Установлены на компрессорных установках GA7 GA15, которые применяются в строительной отрасли.
Сжатый воздух идет на производство тратуарной плитки и небольших изделий ландшафтного дизайна.
Компрессорным установкам Атлас Копко 12 лет. Желательно делать общеобменную вентиляцию с предварительной фильтрацией, но не всегда это получается.

Если у Вас греется винтовой компрессор GA55 Атлас Копко (или подобный), а вентиляция выглядит, как на фотографии, то Вы открываете боковые панели и компрессор начинает работать.
Почему компрессор работает с открытыми дверцами (панелями)?
Перегрев компрессора из-за неправильной вентиляции.
Основные причины:
1) забит пылью или мусором (пухом, насекомыми) радиатор. Его надо продуть в обратную сторону, пропылесосить.
Радиатор должен пропускать свет, а не просто его щёткой отряхнуть.
2 )проверить есть ли теплосъем на входе и выходе из радиатора — разница должны быть около 10 градусов. Это делается или тепловизором или ИК термометром. Руками можно получить ожог. Будьте аккуратны!
Если радиатор холодный, а компрессор перегревается, то проблема в термостатическом клапане.
Термостатический клапан не переключил масло на большой круг через радиатор и произошел перегрев.
3) неправильная вентиляция компрессора, когда она заужена или большой протяженностью, что создает высокое сопротивление воздуха, тепловые пробки и т.д.
Система охлаждения не может обеспечить теплообмен и происходит перегрев винтового компрессора.
Всплывает авария. Открытые дверцы дают временный эффект, но это создает дополнительный шум и загрязнение всего оборудования внутри.

В винтовом компрессоре GA18FF Atlas Copco есть клапан термостатический.
Расзмещается он в гидроплите. Месторасположение выделено красным кругом.
Купить термостат (термостатический клапан) Атлас Копко можно в составе набора или отдельно.
Уточняйте комплектацию.

Так как Атлас Копко ведущий производитель винтовых компрессорных установок, то не обошло стороной и разделение внутри компрессора на горячую и холодную зону.
В холодной зоне организован забор воздуха на сжатие, потому что холодный воздух сжимается лучше горячего и это дает дополнительную энергоэффективность системы в целом.

В Атлас Копко Россия есть центральный склад в г. Химки.
Есть склад нового оборудования, большой склад запасных частей, сервисная служба.
Склады поменьше есть у дилеров в регионах.
Если чего то не нашлось на этих складах, то в течении нескольких недель после Заказа продукция может быть доставлена из Бельгии.
Чтобы избежать простоев оборудования, необходимо проводить плановые работы по обслуживанию винтовых компрессорных установок.
Дополнительно можно приобрести на склад расходные материалы, которые потребуются на следующем обслуживании оборудования.

Если у Вас винтовой компрессор GX или подобный со смотровым глазком, а инструкции по эксплуатации нет или она была потеряна, то необходимо произвести залитие масла, чтобы сверху была «булька» воздуха. Это не каша, много масла — это плохо. Может быть гидроудар.

Для начала необходимо изучить инструкцию по эксплуатации, а затем внутри компрессорной установки найти прессостат (реле давления), открутить верхнюю крышку и отрегулировать верхний порог.
Дельту между верхним и нижним порогом не рекомендуем менять (чтобы небыло постоянных включений и выключений).
Сильно опускать верхний порог тоже не рекомендуется, чтобы не нарушить циркуляцию масла для первоначального запуска системы.
Лучше обратиться в сервисную службу Атлас Копко.

Как понять, что воздушный фильтр винтового компрессора Атлас Копко пора менять?
1) Посмотреть регламент в инструкции по эксплуатации
2) Раз в год или при наработке 4000
3) Позвонить в сервисную службу Атлас Копко и спросить

Менять чаще необходимо, если сильно загрязнен окружающий воздух в помещении.
В идеале поставить фильтры на общеобменную вентиляцию и очистить воздух, но ситуации бывают разные.
Что мы видим на фотографии?
Грязный впускной клапан. Когда воздушный фильтр забивается грязью, компрессору тяжело работать и он может отключаться или по перегреву или по перегрузке двигателя.
Оборудованию тяжело работать и автоматика начинает себя спасать. В этот момент иногда происходит не амена воздушного фильтра, а открытие крышки фильтра или изъятие воздушнохо фильтра.
Компрессор начинает работать напрямую, всасывая в себя весь мусор из окружающего воздуха.
Очень быстро масло наполняется абразивными частицами и происходит выход из строя винтового блока и подшипников.

Проводите обслуживание оборудования своевременно и оно будет Вас радовать долгие годы!

В небольших винтовых компрессорах Атлас Копко (серия GX) раньше использовался впускной клапан, как на фотографии.
(Сейчас модель впускного клапана еще более надежная с меньшим количеством изнашиваемых деталей).
Если этот клапан не обслуживать и на компрессоре не проводить техническое обслуживание, то через какое то время произойдет износ пружин и резиновых уплотнений.

Вы начнете задавать вопросы:

  1. Что делать, если винтовой компрессор не нагнетает воздух?
  2. Почему винтовой компрессор не качает?
  3. У винтового компрессора не растет давление в ресивере?
  4. Что делать если винтовой компрессор Атлас Копко не дает воздух?
  5. В каком случае электродвигатель вращается, а давление в ресивере не растет?
  6. В каком случае винтовой компрессор Atlas Copco не накачивает ресивер?

Одна из причин:
Если при включении компрессора впускной клапан GX не открывается, то или на него не приходит сигнал и проблема с электрической цепью (блок управления-кабели-катушка)
или механическое заклинивание. Если компрессор не отключается при достижении давления (впускной клапан не закрывается) и продолжается набор воздуха в ресивер, то сработает предохранительный клапан.

Почему так может происходить: со временем изнашиваются резинки уплотнительные или пружины, которые периодически требуют замены.

Если сепаратор не менять на винтовом компрессоре согласно инструкции по эксплуатации, то на выходе из конденсатоотводчиков можно регулярно видеть эмульсию.
Как правило, уровень масла начинает падать и это заметно по смотровому глазку.
Также эмульсию можно встретить в заклинивших пневмораспределительных устройствах, если нет фильтров на воздушной магистрале.

На фотографии GA45FF 2003 года, который размещен на поддоне, а под ним ровная поверхность.
Вибраций при работе практически нет, работает так давно, но правильно будет разместить его на полу.

На одном компрессоре GA30VSD не делали технического обслуживания, радиатор забился мусором и грязью, и он остановился по аварии. Причину устранили и продолжили работу. Появился унос масла в пневмосеть, масло стали доливать. Компрессор остановился по аварии. Радиатор почистили, но не помогло. Причина была в том, что забился воздушный фильтр. Его отряхнули и продолжили работу.
Наработка на тот момент составила 20 000!
P.S. Издевались над этим компрессором до 40 000, пока он не попал к официалам, которые вернули его к жизни.

В компрессорных установках Атлас Копко есть комплектация встроенного осушения воздуха, что очень компактно и надежно. Дополнительно или опцией можно поставить фильтры очистки сжатого воздуха от масла и частиц. Кондесат из воздуха отделяется и поступает на ружу через конденсатоотводчики. Необходимо к ним подключить трубопровод или релсановые трубочки и осуществить сброс или в специальную утилизационную емкость, или в специальное устройство очистки конденсата OSC серия.
На фотографии данные участки не подключены.

Крыльчатка электродвигателя LSES200L-T при неправильном демонтаже может начать люфтить после съема. Такой же процесс можно наблюдать если обслуживание двигателя производилось не по регламенту или тяжелые условия эксплуатации (сильное загрязнение и перегрев из-за плохой вентиляции). И тут уже или под замену или Loctite в помощь. Это редко встречающийся двигатель. Поэтому рекомендуется не пропускать технические обслуживания.

Если условия эксплуатации винтового компрессора тяжелые (много пыли, взвеси, и т.д.) и устранить их не получается по каким то причинам, то можно продлить срок службы компрессорного оборудования различными дополнительными опциями. Дополнительно есть различные технологические решения, чтобы уменьшить загрязнение радиатора. Это одна из дополнительных опций, а у некоторых моделей их больше 20!

Жил был винтовой компрессор Atlas Copco 2000 года рождения.
Над ним издевались как могли. Практически не делали ТО, редко меняли масло.
И он доработал до 70000 без кап ремонта. В какой то момент уплотнение винтового блока дало течь по валу.
И что Вы думаете? Его отправили на капитальный ремонт?
Поставили новые подшипники, выставили зазоры, поменяли уплотнение винтового блока на новое?
Произвели техническое обслуживание?
Нет! В него воткнули неорегинальные сальники, но так как аналог не нашли (они изготавливаются на заказ и не поступают в розничную продажу), решили поставить сразу два. Компрессор заработал и через пару часов их выдавило и все масло улетело внутрь компрессора. Данную процедуру повторили несколько раз, компрессор выдержал эти остановы по перегреву и не заклинил. И вот только на этой стадии появился фирменный сервис Atlas Copco.
Был произведен ремонт и обслуживание. Машина встала в строй.

Если винтовой компрессор при включении вращается, но не дает давление, то не открылся впускной клапан. Он мог заклинить по причине износа, попадания посторонних предметов, загрязнения или несвоевременного обслуживания. Мог не поступить сигнал с блока управления (нарушение электроцепи). В нашем случае сигнал поступил (катушка сработала) клапан на выключенном компрессоре проверили и он механически исправен.
Проблема заключалась в неисправном соленоидном клапане. Износ уплотнения.
Продается целиком, ставится легко.

Какие запасные части для винтовых компрессорных установок хранить в ЗИП. Если Вы не пользуетесь регулярным сервисным обслуживанием или делаете его самостоятельно, то желательно иметь на складе:

  1. набор фильтров (воздушный, масляный, сепаратор)
  2. масло
  3. набор термостатического клапана
  4. набор клапана минимального давления
  5. набор всасывающего клапана
  6. комплект ремней (если они есть)

Эти наборы имеют изнашиваемые детали, что потребует замены или по регламенту (на опережение) или по факту выхода из строя (это не рекомендовано, потому что вызывает простои и может вызвать поломки уже не прогнозируемые).
Например: необходимо менять сепаратор по рекомендации завода изготовителя. Если этого не сделать, то через какое то время начнется маслоунос в систему (произойдет загрязнение маслом трубопровода и его элементов), затем может произойти срабатывание предохранительного клапана или разрыв сепаратора и унос масла в систему и перегрев компрессора и срабатывание автоматики на отключение по аварии (какая произойдет раньше).

В любом случае лучше обратиться в сервисную службу и воспользоваться услугами профессионалов или получить консультацию.

При проведении технического обслуживания на компрессорной установке Atlas Copco, когда Вы произвели замену воздушного фильтра, масляного фильтра, сепаратора, масла.
Многие забывают про встроенную дополнительную опцию (на фотографии выделено цветом).
Дополнительная опция к компрессору — это магистральные фильтры очистки сжатого воздуха Атлас Копко (DD и PD), которые очищают воздух от вредных примесей.
Пневматика работает лучше и меньше времени потом уходит на ее переборку.

Если у Вас старая версия блока управления компрессором ELEKTRONIKON Atlas Copco и он не работает или проблема с датчиками температуры и давления,
а компрессорная установка 80х-90х годов выпуска, то можно преобрести Комплект модернизации, в который входит современный блок управления, датчики и все необходимое для замены.

Источник

Безмасляные компрессоры

  • Компрессоры высокого давления GR

    322.8 kB, PDF

  • Винтовые компрессоры G110-250, G160VSD

    5 MB, PDF

  • Центробежные воздуходувки

    842.2 kB, PDF

  • Винтовые компрессоры ZR 300-900

    5 MB, PDF

  • Центробежные компрессоры ZH

    5.9 MB, PDF

  • Водозаполненные компрессоры AQ 15-55

    6.4 MB, PDF

  • Винтовые компрессоры GA90-160

    4.7 MB, PDF

  • Винтовые компрессоры GA160-315 VSD

    1 MB, PDF

  • Винтовые компрессоры ZR-ZT 55-90 (FF)

    5.7 MB, PDF

  • Винтовые компрессоры ZR/ZT 110-275

    5.8 MB, PDF

  • Винтовые компрессоры GA 355-500

    3.1 MB, PDF

  • Зубчатые компрессоры ZT15-22, ZR/ZT 30-45

    5.3 MB, PDF

  • Безмасляные спиральные компрессоры SF

    4.7 MB, PDF

  • Безмасляный поршневой компрессор LZ

    2.5 MB, PDF

Маслозаполненные компрессоры

  • Винтовые компрессоры G и GX

    2.4 MB, PDF

  • Винтовые компрессоры GA 7-75 VSD

    4 MB, PDF

  • Винтовые компрессоры GA 30-90 VSD

    5.1 MB, PDF

  • Винтовые компрессоры GA 7-37 VSD+

    46.8 MB, PDF

  • Промышленные поршневые компрессоры

    3.6 MB, PDF

  • Винтовые компрессоры G15-22, GA 15-26, GA 11-30 VSD

    4.5 MB, PDF

  • Винтовые компрессоры GA 37-110 VSD+

    69 MB, PDF

  • Винтовые компрессоры GA 7-110 VSD

    16 MB, PDF

Подготовка воздуха

  • Адсорбционные осушители BD-CD

    5.1 MB, PDF

  • Магистральные фильтры

    6.8 MB, PDF

  • Рефрижераторные осушители FD

    4 MB, PDF

  • Рефрижераторные осушители FX

    2.8 MB, PDF

Промышленные газы

  • Генераторы азота и кислорода

    3.1 MB, PDF

Ремонт блока управления компрессора >

Регулятор Elektronikon выполняет следующие функции

• управление компрессором;
• защита компрессора;
• контроль компонентов, подлежащих техническому обслуживанию;
• автоматический перезапуск после отказа электроснабжения (эта функция выключена).

Автоматическое управление компрессором

Регулятор поддерживает давление в сети так, чтобы оно находилось между заранее запрограммированными предельными значениями. Управление производится путем автоматической нагрузки и разгрузки компрессора. При этом принимается во
внимание ряд заранее запрограммированных настроек (уставок), например, давления разгрузки и нагрузки, минимальное время останова и максимальное количество пусков электродвигателя.
С целью снижения энергопотребления регулятор останавливает компрессор во всех случаях, когда это возможно, а затем, когда давление в сети падает, автоматически производит повторный пуск.

Защита компрессора

Защитный останов
Если температура на выходе компрессорного элемента превысит запрограммированное значение уровня защитного останова, компрессор будет остановлен. Это отобразится на дисплее (1). Компрессор будет также остановлен в случае перегрузки приводного двигателя.
Компрессоры с воздушным охлаждением будут также остановлены в случае перегрузки двигателя вентилятора.

Перед проведением ремонта изучите раздел «Техника безопасности». 

Ни в коем случае не пытайтесь самостоятельно ликвидировать неполадки. Это может усугубить ситуацию и спровоцировать аварии. Специалисты сервисной службы БВА приедут на объект в любое время дня и ночи и оперативно устранят сбои, не нанося ущерба производственному процессу. Всегда в наличии оригинальные запчасти и расходники.

Предупреждение о защитном останове

Уровень предупреждения о защитном останове представляет собой программируемый уровень, устанавливаемые ниже уровня защитного останова.
Если один из измеряемых параметров превысит запрограммированный уровень предупреждения о защитном останове, то это также отобразится на дисплее, предупреждая оператора перед тем, как будет достигнут уровень защитного останова.

Предупреждение о необходимости технического обслуживания

Если таймер технического обслуживания превышает запрограммированное значение, это указывается на экране дисплея (1), чтобы предупредить оператора о необходимости выполнения операций технического обслуживания.

Автоматический перезапуск после отказа электроснабжения

В регуляторе имеется встроенная функция автоматического перезапуска компрессора, когда напряжение питания восстанавливается после отказа электроснабжения. При отгрузке с предприятия-изготовителя данная функция не активизирована. При необходимости ее можно активизировать. Обратитесь за консультацией в сервисный центр.

Если функция активизирована и при условии, что блок находится в режиме автоматического управления, компрессор будет автоматически перезапускаться, если подача напряжения питания регулятора возобновится в течение запрограммированного промежутка времени.

Регулятор Elektronikon I

Позиция Наименование Назначение
S3 Кнопка аварийного останова Кнопка для немедленной остановки компрессора в случае аварийной ситуации. После устранения неисправности разблокируйте кнопку, вытянув ее из панели, и нажмите клавишу сброса (4).
1 Кнопка «Останов» (Stop) Нажатие кнопки приводит к остановке компрессора. Светодиод (10) гаснет. Компрессор остановится после того, как он проработает в разгруженном режиме в течение примерно 30 с.
2 Кнопка «Пуск» (Start) Кнопка   для   пуска   компрессора.   Загорается   светодиод   (10),   показывая,   что регулятор Elektronikon работает (в режиме автоматического управления).
3 Дисплей Показывает  состояние  работы  компрессора,  текущие  измеряемые  значения  и запрограммированные параметры.
4 Клавиша сброса Клавиша для сброса таймера технического обслуживания, состояния защитного останова и т. д.
5 Клавиша ввода Клавиша для выбора или подтверждения параметра, открытия вспомогательного окна или возврата в предыдущее окно.
6 Светодиод «Напряжение включено» (Voltage on) Показывает, что напряжение включено.
7 Пиктограмма Напряжение включено
8 Светодиод «Общий аварийный сигнал» (General alarm) Горит, если существуют условия для предупреждения.
8 Светодиод «Общий аварийный сигнал» (General alarm) Мигает,  если  компрессор  находится  в  состоянии  защитного  или  аварийного останова.
9 Пиктограмма Аварийный сигнал
10 Светодиод «Автомати- ческое управление» (Automatic operation) Показывает, что регулятор находится в режиме автоматического управления компрессором: компрессор нагружается, разгружается, останавливается и вновь запускается в зависимости от потребления сжатого воздуха и ограничений, запрограммированных в регуляторе.
11 Пиктограмма Автоматическое управление
12 Клавиша прокрутки вниз Клавиша для «прокручивания» вниз окон на дисплее или уменьшения уставки.
13 Клавиша прокрутки вверх Клавиша для «прокручивания» вверх окон на дисплее или увеличения уставки.

Дисплей

Обычно дисплей (1) показывает:
• состояние компрессора с помощью пиктограмм;
• давление сжатого воздуха на выходе компрессора;
• текущую температуру на выходе компрессорного элемента;
• текущую температуру точки росы для компрессоров полнофункциональной модификации.
Дисплей также показывает все измеряемые и запрограммированные параметры, см. раздел «Прокручивание всех окон дисплея».

Пиктограммы, используемые на экране

Пиктограмма Объяснение
Состояние компрессора «НАГРУЖЕН» (во время работы под нагрузкой горизонтальная стрелка мигает).
Состояние компрессора «РАЗГРУЖЕН»
Наработка компрессора
Температура на выходе компрессорного элемента.
Температура точки росы.
Приводной двигатель или двигатель вентилятора перегружен.
Нажата кнопка аварийного останова.

Предупреждение о защитном останове

Предупреждение о защитном останове появится в случае:
• слишком высокой температуры воздуха на выходе компрессорного элемента,
• слишком высокой температуры точки росы для компрессоров полнофункциональной модификации.

Температура воздуха на выходе компрессорного элемента

  • Если температура воздуха на выходе компрессорного элемента превысит уровень предупреждения о защитном останове (110 °С / 230 °F, не программируется), загорится светодиод аварийной сигнализации (4) и появится соответствующая мигающая пиктограмма.

Окно предупреждения о температуре на выходе компрессорного элемента

 

   

мигает

 

bar(бар) 6,6

 
  • Нажмите клавишу со стрелкой (3), появляется надпись < r000 > (регистр 000).
  • Нажмите клавишу со стрелкой (3), появляется текущая температура на выходе компрессорного элемента.

Окно предупреждения о температуре на выходе компрессорного элемента

   

   

мигает

 

°С 111

Окно показывает, что температура на выходе компрессорного элемента составляет 111 °С.

  • Можно прокрутить на экране другие окна (используя клавиши 3 и 5), чтобы проверьте текущие состояния других параметров.
  • Нажмите клавишу (1), чтобы остановить компрессор и дождитесь останова компрессора.
  • Выключите напряжение, осмотрите компрессор и устраните неисправность.
  • Предупреждающее сообщение исчезнет, как только исчезнут условия для его появления.

Температура точки росы

Для компрессоров со встроенным осушителем:

  • Если температура точки росы превысит уровень предупреждения о защитном останове (программируется), загорится светодиод аварийной сигнализации (4) и появится соответствующая мигающая пиктограмма.

Окно предупреждения о температуре точки росы

   

   

мигает

 

bar(бар) 6,6

 
  • Нажмите клавишу со стрелкой (3), появляется надпись < r000 > (регистр 000).
  • Нажмите клавишу со стрелкой (3), появляется текущая температура точки росы.

 Окно предупреждения о температуре на выходе компрессорного элемента

   

   

мигает

 

°С 9

 

Окно показывает, что температура точки росы составляет 9 °С.

  • Можно прокрутить на экране другие окна (используя клавиши 3 и 5), чтобы проверьте текущие состояния других параметров.
  • Нажмите клавишу (1), чтобы остановить компрессор и дождитесь останова компрессора.
  • Выключите напряжение, осмотрите компрессор и устраните неисправность.
  • Предупреждающее сообщение исчезнет, как только исчезнут условия для его появления.

 Защитный останов

 Защитный останов компрессора произойдет в случае:
• если температура воздуха на выходе компрессорного элемента превысит уровень защитного останова;
• ошибки датчика давления на выходе компрессора;
• перегрузки приводного двигателя;
• перегрузки двигателя вентилятора в компрессорах с воздушным охлаждением.

 

Если температура воздуха на выходе компрессорного элемента превысит уровень защитного останова (120 °С / 248 °F, не программируется), произойдет защитный останов компрессора, будет мигать светодиод аварийной сигнализации (4), погаснет светодиод автоматического управления (5) и появится следующее окно:

Окно защитного останова по температуре на выходе компрессорного элемента

   

   

мигает

  • Нажмите клавишу со стрелкой (2), появляется надпись < r000 > (регистр 000).
  • Нажмите клавишу со стрелкой (3), появляется текущая температура на выходе компрессорного элемента.

Окно защитного останова по температуре на выходе компрессорного элемента

   

   

мигает

 

°С 122

Окно показывает, что температура на выходе компрессорного элемента составляет 122 °С.

  • Выключите напряжение и устраните неисправность.
  • После устранения неисправности, и когда исчезнут условия для защитного останова, включите напряжение и вновь запустите компрессор.

Перегрузка двигателя

  • В случае перегрузки двигателя произойдет защитный останов компрессора, будет мигать светодиод аварийной сигнализации (4), погаснет светодиод автоматического управления (5) и появится следующее окно:

Окно защитного останова по перегрузке двигателя

   

   

мигает

  • Выключите напряжение и устраните неисправность.
  • После устранения неисправности, и когда исчезнет условие для защитного останова, включите напряжение и вновь запустите компрессор.

Неисправности и способы их устранения

В компрессорах, оснащенных регулятором Elektronikon I, если горит или мигает светодиод аварийного сигнала, см. раздел «Предупреждение о защитном останове».

Состояние

Неисправность

Способ устранения

Компрессор начинает работать, однако не нагружается по истечении времени задержки.

Неисправен электромагнитный клапан

Замените клапан.

Впускной клапан залип в закрытом положении.

Проверьте клапан.

Утечка в шлангах тракта пневмоуправления.

Замените негерметичные шланги.

Утечка в клапане минимального давления (когда стравливается давление из сети).

Проверьте клапан.

Состояние

Неисправность

Способ устранения

Компрессор не разгружается, выходит воздух из предохранительного клапана.

Неисправен электромагнитный клапан

Замените клапан.

Впускной клапан не закрывается.

Проверьте клапан.

Состояние

Неисправность

Способ устранения

Во время работы под нагрузкой из отделителя конденсата не сливается конденсат

Засорен сливной шланг.

Проверьте и, если нужно, исправьте.

Неисправен поплавковый клапан.

Снимите узел поплавкового клапана, очистите и проверьте.

Состояние

Неисправность

Способ устранения

Производительность компрессора или давление ниже нормы.

Потребление сжатого воздуха превышает производительность компрессора.

Проверьте присоединенное пневматическое оборудование.

Засорен элемент воздушного фильтра.

Замените элемент фильтра.

Неисправен электромагнитный клапан.

Замените клапан.

Утечка в шлангах тракта пневмоуправления.

Замените негерметичные шланги.

Впускной клапан не полностью открыт.

Проверьте клапан.

Засорен маслоотделитель.

Замените элемент.

Утечка воздуха.

Устраните утечку.

Утечка из предохранительного клапана.

Замените клапан.

Неисправен компрессорный элемент.

Проконсультируйтесь в сервисном центре.

Состояние

Неисправность

Способ устранения

Чрезмерный расход масла; в компрессорах с GA5 по GA30C масло выносится в выпускной трубопровод сжатого воздуха

Слишком высокий уровень масла.

Проверьте на отсутствие переполнения.

Стравите давление и слейте масло до правильного уровня.

Неправильный тип масла вызывает пенообразование.

Замените маслом правильного типа.

Неисправен маслоотделитель.

Проверьте элемент маслоотделителя. Если нужно, замените

Состояние

Неисправность

Способ устранения

Предохранительный клапан выпускает воздух после| нагрузки.

Неправильно работает впускной клапан.

Проверьте клапан.

Неправильно работает клапан минимального давления.

Проверьте клапан.

Неисправен предохранительный клапан.

Замените клапан.

Неисправен компрессорный элемент.

Проконсультируйтесь в сервисном центре.

Засорен элемент маслоотделителя.

Замените элемент.

Состояние

Неисправность

Способ устранения

Температура на выходе компрессорного элемента или на выходе компрессора выше нормы.

Слишком низкий уровень масла.

Проверьте и исправьте.

В компрессорах с воздушным охлаждением недостаточная подача охлаждающего воздуха или слишком высокая температура охлаждающего воздуха.

Убедитесь в отсутствии препятствий на пути подачи охлаждающего воздуха, либо улучшите вентиляцию в компрессорном зале. Избегайте рециркуляции охлаждающего воздуха. Если в компрессорном зале установлен вентилятор, проверьте его производительность.

Засорен маслоохладитель.

Очистите охладитель.

Неисправен байпасный клапан.

Проверьте клапан.

Засорен воздухоохладитель.

Очистите охладитель.

Неисправен компрессорный элемент.

Проконсультируйтесь в сервисном центре.

Ошибки винтового компрессора

НЕИСПРАВНОСТЬ: Срабатывает прерыватель цепи защиты от перегрузки

Причина: 1. Низкое напряжение в сети.

Способ устранения: Проверьте напряжение в сети, нажмите кнопку сброса и перезапустите компрессор.

Причина: 2. Перегревается двигатель.

Способ устранения: Проверьте теплоотвод от двигателя и установку реле. Если тепло отводится нормально, нажмите кнопку «Reset» и перезапустите компрессор. Если компрессор не перезапускается сразу, подождите несколько минут и повторите попытку.

НЕИСПРАВНОСТЬ: Термостат отключает компрессор в результате перегрева.

Причина: 1. Очень высокая температура окружающей среды.

Способ устранения: Обеспечьте более качественную вентиляцию, нажмите сброс и сделайте перезапуск.

Причина: 2. Засорен охладитель масла.

Способ устранения: Очистите охладитель растворителем.

Причина: 3. Низкий уровень масла.

Способ устранения: Долейте масло.

Причина: 4. Неисправен термо-расширительный клапан.

Способ устранения: Замените термо-расширительный клапан.

НЕИСПРАВНОСТЬ: Высокий расход масла.

Причина: 1. Неисправна системы слива.

Способ устранения: Проверьте трубопроводы слива масла и обратный клапан.

Причина: 2. Чрезмерный уровень масла.

Способ устранения: Проверьте уровень масла, и при необходимости слейте лишнее.

Причина: 3. Неисправен фильтр маслосепаратора.

Способ устранения: Замените фильтр маслосепаратора.

Причина: 4. Не герметичность уплотнений и/или ниппелей фильтра маслосепаратора.

Способ устранения: Замените уплотнитель.

НЕИСПРАВНОСТЬ: Утечки масла из всасывающего фильтра.

Причина: Не закрыт регулятор всасывания.

Способ устранения: Проверьте регулятор и электромагнитный клапан.

НЕИСПРАВНОСТЬ: Открывается предохранительный клапан.

Причина: 1. Чрезмерно высокое давление.

Способ устранения: Проверьте настройки манометра. Проверьте регулятор всасывания и электромагнитный клапан.

Причина: 2. Регулятор всасывания не закрывается в конце рабочего цикла.

Способ устранения: Проверьте перепад давления между магистральным трубопроводом и резервуаром масляного сепаратора, при необходимости замените фильтр маслосепаратора.

Причина: 3. Засорение фильтра маслосепаратора

Способ устранения: Проверьте перепад давления между магистралью сжатого воздуха и резервуаром маслосепаратора, при необходимости замените фильтр маслосепаратора.

НЕИСПРАВНОСТЬ: Низкая производительность компрессора.

Причина: Загрязнение воздушного фильтра.

Способ устранения: Очистите/замените фильтр.

НЕИСПРАВНОСТЬ: Компрессор не выдает сжатый воздух.

Причина: 1. Закрыт регулятор, не открывается по причине загрязнения.

Способ устранения: Снять всасывающий фильтр и открыть регулятор вручную. При необходимости снять его и очистить.

Причина: 2. Закрыт регулятор, не открывается по причине отсутствия команды на открывание.

Способ устранения: Убедитесь, что реле давления подает питание на электромагнитный клапан, закрывающий данный патрубок.

НЕИСПРАВНОСТЬ: Давление вырабатываемого воздуха значительно превышает установленное максимальное (8, 10 или 13 бар)

Причина: 1. Открыт регулятор, не закрывается по причине загрязнения.

Способ устранения: Снимите и очистите регулятор.

Причина: 2. Открыт регулятор, не закрывается по причине отсутствия команды на закрывание.

Способ устранения: Убедитесь, что электромагнитный клапан, открывающий данный патрубок, отключен.

Причина: 3. Неисправен манометр.

Способ устранения: Проверьте работу и установки реле давления.

НЕИСПРАВНОСТЬ: Компрессор не перезапускается

Причина: Ненадлежащее закрывание контрольного клапана.

Способ устранения: Снимите и очистите клапан. При необходимости замените его компоненты.

НЕИСПРАВНОСТЬ: Компрессор не всегда включается

Причина: 1. Недостаточное напряжение в сети.

Способ устранения: Проверьте напряжение в сети.

Причина: 2. Слишком низкая температура воздуха.

Способ устранения: Нагрейте воздух в помещении или компрессор.

НЕИСПРАВНОСТЬ: Попадание масла в пульт управления

Причина: 1. Утечка масла из трубопровода.

Способ устранения: Затянуть соединительные муфты. Заменить поврежденные части трубопроводы.

Причина: 2. Утечка масла через передний фланец компрессора.

Способ устранения: Замените уплотнительное кольцо компрессора.

Источник

В ходе производственного процесса нередко бывает так, что компрессор функционирует, но выявляются симптомы технических проблем: например, недостаточно либо долго набирается давление, возникают шумы, время от времени сигнализирует панель управления. Как раз в подобных случаях устройство нужно проверить целиком и полностью – для выявления причины, по которой техника начала давать сбой, и исключения аварии, ведущим к остановкам производственного цикла организации.

Эксплуатация винтовых компрессоров, практически всегда, осуществляется на постоянной основе. Но резерв, как правило, отсутствует. Так что ключевая цель – работа устройства без перебоев. Чтобы решить поставленную задачу, можно воспользоваться сразу двумя-тремя инструментами:

  1. Вовремя проводить техобслуживание. Разновидности услуг и требуемые расходники при конкретной наработке, как правило, зафиксированы в инструкции.
  2. Также важно регулярно проводить диагностику. Это ежедневный мониторинг, за который отвечает обслуживающий персонал: контроль рабочих характеристик, уровня масла, отражение показаний управляющей панели – включая ошибки.Также обслуживающий персонал отслеживают температуру в здании, вентиляцию (чтобы в ее работе не возникали сбои).
  3. Периодическую диагностику должны проводить сервисные инженеры. Ключевая составляющая обслуживания – гарант длительного и бесперебойного функционирования устройства.

БВА Сервис выполняет диагностику любых моделей винтовых электрических компрессоров Atlas Copco:

AQ 30, AQ 37, AQ 37 VSD, AQ 45, AQ 55, AQ 55 VSD, AQ15 VSD, AQ18 VSD, AQ22 VSD, AQ30 VSD, AQ55 VSD, G 15L, G 18, G 22, G11, G15, G7, GA 10, GA 11 VSD, GA 110, GA 13,8, GA 132, GA 14, GA 160, GA 160+, GA 250, GA 315, GA 5,3, GA 5,5, GA 7,3, GA 7,5, GA 8,3, GA 8,5, GA 9,8, GA 90+, GA11, GA11 VSD, GA11+, GA110, GA110 VSD, GA132, GA132 VSD, GA15, GA15 VSD, GA15+, GA160, GA160 VSD, GA18, GA18 VSD, GA18+, GA200, GA200 VSD, GA22, GA22 VSD, GA22+, GA250, GA250 VSD, GA26 , GA26 VSD, GA30, GA30 VSD, GA30+, GA315, GA315 VSD, GA37, GA37 VSD, GA37+, GA45 , GA45 VSD, GA45+, GA5, GA5 VSD, GA55, GA55 VSD, GA55+, GA7, GA7 VSD, GA75, GA75 VSD, GA75+, GA90 , GA90 VSD, GX11, GX2, GX3, GX4, GX5, GX7, XA57E, XA77E, XATS 900E, ZR 110, ZR 132, ZR 132 VSD, ZR 145, ZR 160, ZR 160 VSD, ZR 250, ZR 250 VSD, ZR 275, ZR 30, ZR 300 , ZR 315, ZR 315 VSD, ZR 355, ZR 37, ZR 37 VSD, ZR 400, ZR 400 VSD, ZR 425, ZR 45, ZR 450 , ZR 55, ZR 55 VSD, ZR 630 , ZR 700 VSD, ZR 75, ZR 75 VSD, ZR 750, ZR 90, ZR 90 VSD, ZR 900 VSD, ZR VSD, ZT 110, ZT 132, ZT 132 VSD, ZT 145, ZT 15, ZT 160, ZT 160 VSD, ZT 18, ZT 22, ZT 22 VSD, ZT 250, ZT 250 VSD, ZT 275, ZT 30, ZT 315 VSD, ZT 37, ZT 37 VSD, ZT 45, ZT 55 , ZT 55 VSD, ZT 75, ZT 75 VSD, ZT 90, ZT 90 VSD.

БВА Сервис выполняет диагностику любых моделей винтовых дизельных компрессоров Atlas Copco:

XAS 27 Hp, XAS 37 Kd, XAS 38 Kd, XAS 46 Dd, XAS 47 Dd, XAS 48 KD, XAS 57 Dd, XAS 58 KD, XAS 67 Dd, XAS 68 KD, XAS 77 Dd, XAS 78 KD, XAS 87 Kd, XAS 88 Kd, XAS 96, XAS 97 Dd, XAS 127 Kd COM2, XAS 137 Kd COM2, XAS 137 Kd COM3, XAS 186 Dd, XAS 746 Cd, XAHS 37 Dd, XATS 67 Dd, XAHS 107 Kd, XAHS 107 Kd COM2, XAHS 107 Kd COM3, XAHS 146 Dd, XATS 156 Dd, XAVS 166 Dd, XAHS 186 Dd, XAVS 196 Dd, XAHS 237 Dd, XAMS 287 Dd, XAHS 306, XATS 377 Cd, XAVS 307 Cd, XAHS 347 Cd, XAHS 350 CUD, XAVS 407 Cd, XAMS 407 Cd, XAHS 447 Cd, XAHS 450 CUD, XATS 487 Cd, XAMS 527 Cd, XAH 1066 Cd, XAXS 277 Cd, XRVS 336 Cd, XRHS 366 Cd, XRS 396 Cd, H 23, XRVS 476 Cd, XRVS 487 Cd, XRHS 506 Cd, XRHS 527 Cd, X 28, XRYS 527 Cd, XRYS 557 Cd, XRYS 577 Cd, XRXS 567 Cd, XRVS 577 Cd, XRVS 617 Cd, XRXS 607 Cd, XRVS 647 Cd, XRXO 667 Cd, Y 35, XRVO 727 Cd, XRV 946 Cd, U130 Kd, U175 Kd, U190 Kd.

На периодичность, с которой диагностируют состояние винтового компрессора, влияют: интенсивность эксплуатации (24, 12, 8 часов), соответственно, 1 раз: в месяц, в два месяца и в три месяца.

Диагностика – одно из самых необходимых мероприятий для поддержания техники в рабочем состоянии

Она состоит из следующих этапов:

— режимов работы (загрузка, разгрузка, ожидание, холостой ход);

— клапанов (впускного, маслозапорного, обратного, термостатического, клапана минимального давления, дренажного);

— тока и напряжения в разных режимах работы;

— состояния шлангов и соединений (нет ли утечек);

— состояния приводных ремней и муфт;

— уровня масла, замер его расхода;

— вибрации подшипников винтового элемента и электродвигателя;

— системы сброса конденсата;

— состояния воздушных фильтров, при необходимости их очистка или замена.

  • Продувки теплообменника (радиатора) – если это необходимо.
  • Составления акта, где фиксируют рекомендации по плановым ремонтным работам.

Сотрудники нашей организации ежедневно видят разные ситуации, при которых компрессор выходит из строя. Время от времени инженеры нашей компании проходят обучающие курсы – с практическими занятиями. Мы детально исследуем любую аварийную ситуацию – наша база содержит огромное количество статистических данных по наработке и отказам узлов популярных компрессорных моделей. Наши мастера обладают специальным оборудованием и инструментами, благодаря которым выявляют и устраняют все возможные неполадки. Еще у нас имеются на складе все самые ходовые запчасти и расходники. Чтобы грамотно выявить, почему вышел из строя компрессор, советуем своевременно воспользоваться диагностикой устройства.

Вибродиагностика метод диагностирования технических систем и оборудования. Берут в расчет параметры вибрации, издаваемой исследуемым компрессором. Если замерять этот показатель время от времени, можно оперативно увидеть изношенные детали. Так же вибродиагностика рекомендована после произведенного ремонта для оценки качества работ и правильности монтажа узлов оборудования.

Полноценный отчет о том, в каком состоянии находится Ваше устройство, нужно ли его ремонтировать, и во сколько обойдутся запчасти, Вы получите после диагностики. Как правило, речь идет о двух-трех днях!

Вероятные технические неполадки

Приведем краткий перечень неисправностей и причины их появления, на которые следует обратить внимание при диагностике промышленной компрессорной техники:

Неисправность:

— Компрессор начинает работать, но не переходит в режим загрузки.

— Неисправен электромагнит, залипло впускное устройство, порван шланг пневмоуправления, неисправен клапан минимального давления.

Неисправность:

— Не переходит в режим разгрузки, срабатывает предохранитель.

— Неисправен соленоид (электромагнит), не закрывается разгрузочный (впускной) устройство.

Неисправность:

— Выдает большое количество воды в сжатом воздухе.

— Сломан конденсатоотводчик, забит сливной шланг, не правильные условия эксплуатации компрессора.

Неисправность:

— Производительность или давление ниже нормы.

— Повреждено устройство разгрузки, загрязнен воздушный фильтр, поврежден соленоид, засорен маслоотделитель (маслосепаратор), разрушен винтовой блок, порван шланг пневматический, производительность компрессора ниже потребления воздуха.

Неисправность:

— Повышенное потребление масла / унос масла со сжатым воздухом в систему.

-Высокий уровень масла, неправильный тип масла, неисправен маслоотделитель или клапан минимального давления (работает при давлении менее 3,5 бар).

Неисправность:

— Температура сжатого воздуха на выходе из винтового элемента выше нормы

— Низкий уровень масла, засорен маслоотделитель, поврежден термостат, засорен радиатор охлаждения (воздухоохладитель), не работает вентилятор охлаждения, недостаточная подача притока воздуха в компрессорную, слишком высокая температура в компрессорной, неисправен винтовой элемент.

ВНИМАНИЕ! Если Вы заметили один, или несколько из этих признаков, немедленно обратитесь к специалистам!

  • компрессор плохо включается или не перезапускается;
  • отсутствие сжатого воздуха в выходном отверстии компрессора;
  • низкая производительность;
  • чрезмерный расход и утечка масла;
  • непроизвольное открытие предохранительного клапана;
  • отключение компрессора термостатом;
  • повышенное давление;
  • срабатывание прерывателя цепи.

По результатам диагностики наша компания может предложить следующие услуги

1. Техническое обслуживание, ремонт или замену:
— впускного (разгрузочного) клапана,
— маслозапорного клапана,
— обратного клапана,
— термостатического клапана,
— клапана минимального давления,
— дренажного клапана,
— винтового блока (элемент сжатия),
— электродвигателя,
— вентилятора,
— воздухоохладителя,
— блока управления,
— электрического щита и его компонентов,
— датчиков — давления, температуры, включения.
2. ТО компрессора согласно его наработке и состояния.
3. Провести выше обозначенные работы с системами подготавливающими сжатый воздух.
4. Пневмоаудит.

Это только основные услуги, при необходимости возможно оказание и дополнительных услуг, по договоренности с заказчиком.

Выезжаем в любой район Москвы и Московской области

Компания БВА Сервис предлагает качественную диагностику компрессоров в Москве и Московской области .

Мы производим диагностику как в нашем сервисном центре, так и на месте поломки, куда выезжает специалист сервисного центра.

Причины выбрать нас

Принимая решение о выборе исполнителя, важно проанализировать не только стоимость работ, но и спектр предоставляемых им услуг и отзывы клиентов!

Источник

Hey! This site is reader-supported and we earn commissions if you purchase products from retailers after clicking on a link from our site.

A common problem with Atlas Copco air compressors is Atlas Copco compressor fault codes. This article will provide you with some useful information on compressor error codes, along with existing reader questions and responses about Atlas Copco compressor fault codes!

Table of Contents

  • Reasons Atlas Copco Compressor Shows Fault Codes
    • Error Fault
    • System Fault
  • Additional Atlas Copco Pages
  • Reader Questions & Responses
    • Atlas Copco Compressor Fault Codes Error – Atlas Copco Air Compressor Troubleshooting
    • Atlas Copco Compressor Showing JDEC Warning – Atlas Copco Compressor Fault Codes JDEC
    • Troubleshooting an Expansion Module Error on Atlas Copco compressor – Atlas Copco Air Compressor Troubleshooting
    • XAHS 273 Atlas Copco Stop Fault code –
    • XAX 300 Atlas Copco Compressor Temp Fault
    • XAS 375 JD6 “Internal Error Unack” Atlas Copco Compressor Fault Code

Reasons Atlas Copco Compressor Shows Fault Codes

In the event of a system fault, the Atlas Copco compressor should display a fault code in the user operational display menu on the controller. If there is more than one fault code active, each will be displayed as separate items in this operational display menu; they can be viewed by pressing up or down to view.

The fault codes displayed on the Atlas Copco air compressor should be separated into unit faults (ERR/ERROR), and system alarms (SYS/WARNING).

Error Fault

When the compressor displays an error or shutdown, the conditions of the error will automatically reset once the condition has been resolved and the air compressor has restarted, working with no issues.

System Fault

When the compressor displays a system alarm warning, the conditions are automatically reset when the condition has been resolved and reset on the compressor.

It’s common for the fault codes to be separated by some regarding a problem or error with the controller itself which prevents normal operation of the compressor, and system faults that occur externally from the controller and with the compressor.

The Atlas Copco compressor fault codes will likely show their errors in two different light patterns:

  1. LED will flash slowly – this indicates an alarm warning condition where the compressor is continuing with the normal operation but user attention is required still.
  2. LED flashes fast – this indicates a trip condition where the controller will stop the operation of the compressor until the conditions of the error are resolved.

Typically the fault codes will be labeled with unique numeric codes which can then be understood from the user’s manual for the specific Atlas Copco compressor.

Additional Atlas Copco Pages

  • Atlas Copco Air Compressor Troubleshooting
  • Atlas Copco Air Compressor Will Not Stay Running
  • Atlas Copco Compressor Oil – Choosing Oil, How Much To Use & Changing Oil

Reader Questions & Responses

Atlas Copco Compressor Fault Codes Error – Atlas Copco Air Compressor Troubleshooting

Question

I’m working with a new Atlas Copco 50 hp IVR reciprocating air compressor.

My problem is when I start the compressor after a few minutes it shows COMPRESSOR MOTOR CONVERTER TIME OUT.

I have reset but repeatedly it shows the same error.

Please let me know what is the actual problem.

Thank you in advance!

Question

250z Atlas Copco (fault) compressor motor converter time out – does anyone know what the cause is

Question

We have GA 50W VSD…Now the problem of motor converter time out on display. Please, tell me why the resin of the problem and how to solve its problem…..

Response

Dear all,

I have the same issue with my ZR250VSD. after completing maintenance, we turned on the power, started, and appeared the error “converter time out”, could not reset. now waiting for OEM to come.

Response

Hi all,

* Check communication cable
* Isolate the converter from the module, and use the VSD simulation software to test whether the module or converter is at fault.

–> A PC and RS485 <-> RS232 converter box is required as well as the DFM4win cable) is required. The cable is to be connected in place of the converter cable connection. If the RS485 port is faulty ==> new module is required.
– Replace the Modbus adapter card.


Atlas Copco Compressor Showing JDEC Warning – Atlas Copco Compressor Fault Codes JDEC

Question

JDEC warning unAck on display what does that mean?

Response

Typically, a device is being polled but is not responding. That’s about my understanding of it.

Has anyone heard from Atlas Copco on this issue?


Troubleshooting an Expansion Module Error on Atlas Copco compressor – Atlas Copco Air Compressor Troubleshooting

Question

What is causing an expansion module error on the compressor which I have to power reset to start the compressor back up?

Response

SIOE module in the comm box

With luck, you can just r/r it, maybe clean contacts if just re-seating doesn’t do it.

Failing that, check the module for obvious problems like burnt components, bad solder joints, etc.

Good luck.

Response

Give me your email address. I will show you a video of the error.

(Saad, rather than one email address, please provide a link to the video as a comment here so that all can see it. Thank you. Moderator)


XAHS 273 Atlas Copco Stop Fault code –

Question

I have an air compressor (XAHS 273, Atlas Copco),

I can start the compressor without a problem and load with air normally, but the issue is when I’m trying to switch it off the engine does not stop, it displays (stop failure) even when I press emergency the engine keeps working and never stop

Note that before I start the engine, it displays an EIC warning Unack

Atlas Copco XAS 273 construction compressor

Please help and many thanks in advance

Response

Well, there are two main ways to stop a diesel, cut off the fuel or the air. Emergency stop (at least in North America) cuts off the air intake so it can’t run on environmental fumes.

So, it’s getting air when it shouldn’t, and probably the Unack is telling you there is some fault with the engine air control device.

Good luck.


XAX 300 Atlas Copco Compressor Temp Fault

Question

Hey there I have a XAX 300 Atlas Copco comp and I recently got an element temp unack fault…

The compressor has not run yet, it is not overheated and in testing, I do not have a signal/voltage going to the temp sensor under the compressor.

Removed wires and temp probe is “open” and tested the wires going to it and they have no voltage to them on either red or blue wire.

Is there something to check? Fuse?

Response

Atlas Copco XAS 300 air compressor

I’m going to guess that your compressor is an XAS 300 as opposed to XAX 300?

If it were a fuse, looks like the whole panel would be down.

TS is normally closed, so as a test, try shorting the wires to it. That should satisfy the controller.

If not, check the wiring.

If so, then replace TS.

Good luck.


XAS 375 JD6 “Internal Error Unack” Atlas Copco Compressor Fault Code

Question

Hi anyone who can help,

We have an Atlas Copco XAS 375 JD6 screw compressor here on-site in PNG.

Its displaying “internal error unack”, also “sensor fail S unack”.

Atlas Copco XAS-375 air compressor

Now we all know that “unack” is UNACKNOWLEDGED. But what is the machine referring to by “internal error”?

Internal of the control panel?

It’s a game of musical chairs to remove any faults on the control panel and the machine won’t start the start cycle/preheat either.

Here’s what has been done:

  • basics – fuel filters ,levels,belts etc
  • comp oil replaced and element cond checked (ok)
  • all airlines and scavenge tubes were checked for blockage
  • wiring going ion to the rear of the control panel checked for loose
  • connections
  • plunger/air end outlet, removed and checked for sticky/stuck and
  • lubed up
  • battery charged
  • powered by john deere pe4045
  • model number xas375 13
  • no wiring diagram or air schematic here either(does anyone have one or both?)

If so we would really appreciate the help people, we are up the creek no paddle.

(If you have these documents or .pdf files, they can be uploaded using the comment form at the end of this page. Moderator)

Response

Sounds like the sensor is the root.

If you can find it/them I’d check the wires at the sensor ends.

With luck, you can disconnect them in turn, and the one that doesn’t present a new unack will be the faulty one.

Good luck.


If you have any questions regarding Atlas Copco air compressor fault codes, please leave a comment below, with a photo if applicable, so that someone can help you!

Понравилась статья? Поделить с друзьями:
  • Инструкция gigaset a100 инструкция на русском
  • Способ применения де нол взрослым в таблетках инструкция по применению
  • Мед препарат розувастатин инструкция по применению цена
  • Облепиховое масло официальная инструкция по применению
  • Найдите верное утверждение после распада ссср российское руководство