Atlas Copco GA90 Air Compressor PDF User Guides and Manuals for Free Download: Found (4) Manuals for Atlas Copco GA90 Device Model (Instruction Book)

More Air Compressor Device Models:

  • Parkside

    PKZ 180 B2

    IAN 108972COMPRESSOR PKZ 180 B2 COMPRESSORTranslation of the original instructions KOMPRESSOROriginalbetriebsanleitungCV_108972_PKZ180B2_LB6.indd 2CV_108972_PKZ180B2_LB6.indd 2 14.01.15 15:1914.01.15 15:19 …

    PKZ 180 B2 Air Compressor, 26

  • Craftsman

    919.165610 Operators

    D21879 Rev. 3 9/17/04Operators ManualCAUTION: Read the Safety Guidelinesand All Instructions Carefully BeforeOperating.Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Craftsman website: www.sears.com/craftsmanPermanently Lubricated2 StageTwin ValveStationaryAIR COMPRESSOR• Safety Guidelines� …

    919.165610 Operators Air Compressor, 36

  • Harbor Freight Tools

    68149

    SIX GALLON OILLESS AIR COMPRESSORModel6769668149SET UP AND OPERATING INSTRUCTIONSVisit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.Copyright© 2010 by Harbor Freight Tools®. All rights reserved. No portion …

    68149 Air Compressor, 18

  • Craftsman

    921.16472

    Owner’s ManualCAUTION:Before using this product,read this manual and followall its Safety Rules andOperating Instructions.Sears Brands Management Corporation, Hoffman Estates, IL 60179 U.S.A.www.craftsman.com6/23/2010_Rev. BPart No. 200-2798AIR COMPRESSOR OillessSingle StageDirect Drive, Electric33 Gallon VerticalMo …

    921.16472 Air Compressor, 32

Recommended Documentation:

Responsible for setting up, maintaining, or repairing an Atlas Copco GA 90 compressor? You are in the right place. We have all the necessary information published directly from the original manufacturer and then some: checklists, troubleshooting guides, parts lists, diagrams, and more.

The following resources apply to the Atlas Copco GA90, GA110, GA132, GA160, GA200, GA250, GA315, GA90W, GA110W, GA132W, GA160W, GA200W, GA250, and GA 315W only.

Whether you are building a preventive maintenance plan or loading assets and checklists into a new CMMS software, careful consideration of assembly instructions, operating procedures, and maintenance and service recommendations is required for your equipment’s effective and safe operation. This downloadable manual has all the information you need.

Want to see Limble in action? Get started for free today!

Table of Contents for Atlas Copco GA90:

  • 2920 1251 02 28 Instruction book Warning Before carrying out any maintenance, repair or adjustment, stop the compressor, press emergency stop button (S2- Fig. 3a), switch off the voltage and depressurize the compressor. Notes — Whenever a warning, service request, sensor error or motor overload message is displayed, the free spaces on the display between function keys (5-Fig. 3a) are filled with blinking indicator

  • 2920 1251 02 21 Instruction book Fig. 9a IEC/VDE

  • 2920 1251 02 38 Instruction book 7.5.6 Specific data of GA/GA W 90 up to -160 100 psi — 60 Hz 1) Compressor type 90 110 160 90 W 110 W 160 W Maximum working pressure . . . . . . . . . . bar(e) 7.4 7.4 7.4 7.4 7.4 7.4 Nominal working pressure . . . . . . . . . . . bar(e) 6.9 6.9 6.9 6.9 6.9 6.9 Air temperature at outlet valve, approx. °C27 2830282830 Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1785 1790 1790 1785 1790 1790 Power input 3) . . . . . . . . . . . . . . . . . . . . kW 108 129 176 104 125 169 Oil capacity. . . . . . . .

  • 2920 1251 02 23 Instruction book 2.3.4 GA/GA W — 60 Hz compressors for Canada/USA Compressor type Mains + earth cable in mm 2 440/460 V 575 V 90 3xMCM250 + AWG0 3xAWG00 + AWG4 110 3xMCM300 + AWG0 3xAWG4/0 + AWG2 160 2x (3xAWG00 + AWG4) 3xMCM300 + AWG0 200 2x (3xAWG4/0 + AWG2) 2x (3xAWG00 + AWG4) 250 2x (3xMCM250 + AWG0) 2x (3xAWG3/0 + AWG2) 315 2x (3xMCM350 + AWG0) 2x (3xAWG4/0 + AWG2) 2.4 Pictographs Following pictographs are provided on control panel (

  • 2920 1251 02 27 Instruction book 3.5 During operation (Fig. 3a) 1. When automatic operation LED (1) is alight, starting and stopping of the motor is controlled automatically. 2. Check the readings on display (4). See below. 3. On reaching the pre-set unloading pressure, shown on display (4), the compressor will run unloaded. The operation of the compressor is automatically controlled by the regulator depending on the air consumption. 4. To unload the compressor manually, press key <<Unload>> (5) 1). To put the compressor back into a

  • 2920 1251 02 9 Instruction book in compressor element (E). Compressed air and oil are discharged to air receiver/oil separator (AR) via check valve (CV). In the oil separator compressed air is separated from the oil. The air is blown via minimum pressure valve (Vp) to air cooler (Ca). The cooled air is discharged through moisture trap (MTa) and outlet valve (AV) towards the air net. Check valve (CV) prevents blow-back of compressed air. GA/GA W 200 up to -315 Air drawn through filters (AF) and unloaders (UA1 and UA2) is compressed

  • 2920 1251 02 5 Instruction book 1.2.1.4 Automatic restart after voltage failure For compressors leaving the factory, this function is made inactive. If desired, the function can be activated. Consult Atlas Copco. Warning If activated and provided the regulator was in the automatic operation mode and the compressor control mode (local, remote 1 or remote 2 — see section 1.2.3) was not changed during the voltage failure, the compressor will automatically restart if the supply vo

  • 2920 1251 02 25 Instruction book 3 OPERATING INSTRUCTIONS Safety precautions The operator must apply all related safety precautions including those mentioned in this book. Outdoor/altitude operation If the compressor is installed outdoors or if the air inlet temperature can be below 0°C (32°F), precautions must be taken. In this case, and also if operating at high altitude, consult Atlas Copco. Moving/lifting The compressor can be moved by a lift truck using the slots in the frame. Make sure tha

  • 2920 1251 02 16 Instruction book Fig. 6d. Dimension drawing GA W 132 and -160 Fig. 6e. Dimension drawing GA200 up to -315

  • 2920 1251 02 10 Instruction book Oil stop valve (Vs) prevents compressor element (E) from flooding with oil when the compressor is stopped. Valve (BV) by-passes oil cooler(s) (Co) when starting the compressor from cold condition to ensure rapid warming of the oil to normal working temperature. GA/GA W 200 up to -315 Air pressure forces the oil from receiver (AR) through oil cooler(s) (Co), filters (OF) and valves (Vs1 and Vs2) to compressor elements (E1 and E2) and the lubrication points. Oil stop valves (Vs1 and Vs2) prevent compressor elements

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Atlas Copco GA90 device using right now.

Понравилась статья? Поделить с друзьями:
  • Гербицид деймос инструкция по применению цена
  • Представительство курганской области в москве руководство
  • Инструкция по установке активной антенны бош
  • Дилтиазем ланнахер 180 инструкция по применению цена отзывы аналоги
  • Дидрогестерон инструкция по применению цена отзывы аналоги цена