Чиллер climaveneta руководство

  1. Manuals
  2. Brands
  3. CLIMAVENETA Manuals
  4. Chiller

ManualsLib has more than 52 CLIMAVENETA Chiller manuals

Click on an alphabet below to see the full list of models starting with that letter:

A
B
H
I
M

Models

Document Type

A

a-LIFE3

Instructions For Installation, Use And Maintenance Manual

B

BRH 0011 FF

Installation — User — Maintenance Manual

BRH 0021 FF

Installation — User — Maintenance Manual

BRH 0025 FF

Installation — User — Maintenance Manual

BRH 0031 FF

Installation — User — Maintenance Manual

BRH 0041 FF

Installation — User — Maintenance Manual

BRH 0051 FF

Installation — User — Maintenance Manual

BRH 0061 FF

Installation — User — Maintenance Manual

BRH 0071 FF

Installation — User — Maintenance Manual

BRH 0091 FF

Installation — User — Maintenance Manual

BRH 0101 FF

Installation — User — Maintenance Manual

BRH 0121 FF

Installation — User — Maintenance Manual

BRIDGE iRS2

Manual

H

HRAN 0011

Manual

HRAN 0021

Manual

HRAN 0025

Manual

HRAN 0031

Manual

HRAN 0041

Manual

HRAN 0051

Manual

HRAN 0061

Manual

HRAN 0071

Manual

HRAN 0091

Manual

HRAN 0101

Manual

HRAN 0121

Manual

HRAN 0151

Manual

HRAT 0011

Manual

HRAT 0021

Manual

HRAT 0025

Manual

HRAT 0031

Manual

HRAT 0041

Manual

HRAT 0051

Manual

HRAT 0061

Manual

HRAT 0071

Manual

HRAT 0091

Manual

HRAT 0101

Manual

HRAT 0121

Manual

HRAT 0151

Manual

HRAT E 0011

Manual

HRAT E 0021

Manual

HRAT E 0025

Manual

HRAT E 0031

Manual

HRAT E 0041

Manual

HRAT E 0051

Manual

HRAT E 0061

Manual

HRAT E 0071

Manual

HRAT E 0091

Manual

HRAT E 0101

Manual

HRAT E 0121

Manual

HRAT E 0151

Manual

I

i-LIFE2

Instructions For Installation, Use And Maintenance Manual   •   Manual

M

MICS FF

Installation, Operating And Service Manual

MICS-N FF

Installation, Operating And Service Manual

(Ocr-Read Summary of Contents of some pages of the CLIMAVENETA W3000 Document (Main Content), UPD: 28 June 2023)

  • 3, CLIMAVENETA W3000 C0240102-01-10-GB 3 Caution: The W3000 SE controller software is protected by a digital signature. This means that it can only work on boards supplied by Climaveneta and not on boards purchased from other dealers.

  • 12, C0240102-01-10-GB 12 1.6 Setting adjustment methods Depending on the type of compressor used, various adjustment methods may be selected. Compressor Type of unit Adjustment method Hermetic Water/water heat pump Quick Mind on outlet probe Quick Mind on inlet probe Proportional step on inlet probe Proportional step on inlet probe + integral on inlet probe Water/water chiller Evapora…

  • 39, CLIMAVENETA W3000 C0240102-01-10-GB 39 Mask Description Par.N. An. Out. slave exp5 N° Value 1 00.0 V Voltage applied to analogue output 1 of expansion 5 (if present).  Setpoint …

  • 36, C0240102-01-10-GB 36 Mask Description Par.N. An. In. master exp2 N° Value 1 04.2 bar 2 03.9 bar 3 35.6 °C 4 40.5 °C 5 22.3 °C 6 24.2 °C Displays analogue inputs 1, 2, 3, 4, 5 and 6 of expansion 2 (if present). Master is only specified on units with 3 or 4 circuits. An. In. master exp2 N° Valu…

  • 37, C0240102-01-10-GB 37 Mask Description Par.N. An. Out. master exp5 N° Value 1 00.0 V Voltage applied to analogue output 1 of expansion 5 (if present). Master is only specified on units with 3 or 4 circuits. Dig. In. 12345 67890 slave CCCCC CC…

  • 1, W3000 Second Edition USER MANUAL C0240102-01-10-GB For software versions GA07 Replaces C0240 102-10-09-GB CLIMAVENETA S.p.A Via Sarson, 57C 36061 Bassano del Grappa(VI)-ITALY Tel. (+39) 0424 509 500 Fax (+39) 0424 509 509 http://www.climaveneta.it/ mailto:[email protected] H H The information contained in this document may be modified withou…

  • 14, C0240102-01-10-GB 14 The following tables show some typical values for the parameters in question. The theoretical maximum and minimum outlet temperature values refer to operation at nominal flow rates (with a thermal head at the evaporator of 5 °C and sufficient water in the system to ensure a litre / KW ratio equal to or greater than 7). N° steps Setpoint (°C) Proportional band (°C) Theoric min. outlet T (°C) Theoric max. outlet T (°C) 2 9.5 2.5 5.7 10.8 4 7 5…

  • 43, C0240102-01-10-GB 43 Mask Description Par.N. Inverter 4: Online Command 1400 rpm Revs 1400 rpm Displays whether inverter 4 is online with the controller. Also displays the command and the effective speed of rotation of the screw compressor wi…

  • 16, C0240102-01-10-GB 16 1.6.3 Quick mind adjustment Users must set the required setpoint as the other parameters are adapted to the system by the Quick Mind algorithm. QUICK MIND is a self-adapting algorithm for adjusting the temperature of the water treated by an all-in- one unit. The following figure shows how this adjustment is made: Tout ZONA NEUTRA Setpoint Attivazione compressori Disattivazione compressori …

  • 28, C0240102-01-10-GB 28 ALARM DESCRIPTION DETAILS RESET 814 Inverter 4 communication alarm “as above, for compressor 3″ M 821 Inverter 1 safety input alarm Safety input alarm on inverter of compressor 1 (only for units with screw compressors with inverter) M 822 Inverter 2 safety input alarm “as above, for compressor 3″ M 823 Inverter 3 safety input alarm “as above, for compressor 3″ M 824 Inverter 4 safety input alarm “as above, for co…

  • 25, C0240102-01-10-GB 25 ALARM DESCRIPTION DETAILS RESET 303 Compressor 3 inverter temperature “as above, for compressor 3” A/M 304 Compressor 4 inverter temperature “as above, for compressor 4” A/M 311 Compressor 1 discharge temperature Compressor 1 discharge overtemperature (only for units with centrifuge compressors) A/M 312 Compressor 2 discharge temperature “as above, for compressor 2” A/M 313 Compressor 3 discharge temperature “as above, …

  • 30, CLIMAVENETA W3000 C0240102-01-10-GB 30 Mask Description Par.N. Enable time bands : Disabled Activates/deactivates time bands. The time bands cannot be activated if the external setpoint is enabled. 39.41 Serial line configuration: Disabled …

  • 23, CLIMAVENETA W3000 C0240102-01-10-GB 23 ALARM DESCRIPTION DETAILS RESET 075 Condenser antifreeze Low water temperature at condenser outlet. Except for W3000 base, it also specifies which condenser (if more than one) is involved in the alarm condition. The alarm also appears if the antifreeze limit trips more than 5 times in 8 operating hours (only for water/water units with freon reversal). M 076 Recuperator…

  • 24, C0240102-01-10-GB 24 ALARM DESCRIPTION DETAILS RESET 152 Compressor 2 maintenance “as above, for compressor 2″ S 153 Compressor 3 maintenance “as above, for compressor 3” S 154 Compressor 4 maintenance “as above, for compressor 4” S 155 Compressor 5 maintenance “as above, for compressor 5” S 156 Compressor 6 maintenance “as above, for compressor 6” S …

  • 35, C0240102-01-10-GB 35 Mask Description Par.N.  In/Out   Access mask to In/Out menu. Press «Up» or «Down» to scroll the other masks and «Esc» to return to the submenu. Dig. In. 12345 67890 master CCCCC CCCCC CCCCC CCC Dig. Out. 12345 67890 …

  • 27, C0240102-01-10-GB 27 ALARM DESCRIPTION DETAILS RESET 644 High pressure in circuit 4 pre-alarm “as above, for circuit 4″ S 701 Inverter 1 offline No communication with the inverter on compressor 1 (only for units with screw compressors with inverter) M 702 Inverter 2 offline “as above, for compressor 2” M 703 Inverter 3 offline “as above, for compressor 3” M 704 Inverter 4 offline “as above, for compres…

  • 22, C0240102-01-10-GB 22 2 ALARMS Press the [ALARM] key once to enter the “alarms menu” and view the alarm message along with its code. If there is more than one alarm, scroll the menu using the [UP] and [DOWN] keys. In the W3000 base, “NO A” is displayed if there is no alarm, otherwise the alarm code appears. Press any other key to exit from this menu. To reset the alarm press the [ALARM] key again and hold it down…

Контактный телефон: (495) 664-23-70

E-mail: , пожалуйста, укажите свой контактный телефон

© 2011 — 2023 splitoff
Цены на сайте не являются публичной офертой и указаны без НДС.
Публикация данных статей, фото, видео материалов на других сайтах, форумах, чатах, блогах, без письменного разрешения авторов сайта запрещена.
Регистрируясь на сайте или ставляя отзыв (комментарий), вы соглашаетесь с политикой конфиденциальности.

Summary

1 CONNECTIONS ………………………………………………………………………………………………………………4

……………………………………………………………………………………………………….. 5

……………………………………………………………………………………………………….. 6

………………………………………………………………………………………………………………….. 7

…………………………………………………………………………………………………………… 8

2 SETUP ………………………………………………………………………………………………………………………………8

3 SOFTWARE…………………………………………………………………………………………………………………….9

……………………………………………………………………………………………………………. 9

……………………………………………………………………………………………………… 10

3.4 ALARMS………………………………………………………………………………………………………………….. 10

3.4.2 General alarms…………………………………………………………………………………………………10

4 ALARM SIGNALS …………………………………………………………………………………………………………11

6 REGULATION………………………………………………………………………………………………………………..15

7 PARAMETER LIST………………………………………………………………………………………………………..16

8 ENCLOSURES ……………………………………………………………………………………………………………….23

………………………………………………………………………………………………. 4

…………………………………………………………………………………………………. 6

……………………………………………………………………………………………….. 7

…………………………………………………………………………………………………… 7

…………………………………………………………………………………………. 8

…………………………………………………………………………….. 9

………………………………………………………………………………… 15

……………………………………………………………………………………….. 15

TECHNICAL MANUAL

CVM 2

C 5001 CV/04-99 GB

………………………………………………………….. 13

1

Контактный телефон: (495) 664-23-70

E-mail: , пожалуйста, укажите свой контактный телефон

© 2011 — 2023 splitoff
Цены на сайте не являются публичной офертой и указаны без НДС.
Публикация данных статей, фото, видео материалов на других сайтах, форумах, чатах, блогах, без письменного разрешения авторов сайта запрещена.
Регистрируясь на сайте или ставляя отзыв (комментарий), вы соглашаетесь с политикой конфиденциальности.

CVM 2
Контроллер состоит из главной платы, расположенной в панели управления, и клавиатуры. К главной плате подключается плата управления скоростью вращения вентилятора. Клавиатура соединена с главной платой линией последовательной передачи информации по принципу токовой петли. Электропитание на клавиатуру подается с главной платы.

Скачать

CVM 20
Техническое описание блока CVM 20 Содержание: • Подключение внешних устройств • Подключение источника электропитания • Последовательные порты передачи данных • Программное обеспечение • Перечень аварийных сигналов • Регулирование • Вывод информации на принтер • Настройка • Список параметров

Скачать

CVM 300
Техническое руководство. Электронный контроллер CVM 300 для 1-компрессорных и 2-компрессорных агрегатов состоит из основной платы и панели управления. Обмен информацией между основной платой и панелью управления осуществляется через линию последовательной передачи информации по принципу токовой петли. На основной плате установлена плата с микропроцессором для управления агрегатами. Управляющая программа хранится в EPROM (СППЗУ), а параметры, данные калибровки и предыстории – в EERPOM (ЭСППЗУ). Параметры вводятся с клавиатуры панели управления.

Скачать

CVM 3000
КОсновная плата связана с панелью управления и индикации через линию последовательной передачи информации по принципу токовой петли, а с платой расширения – через последовательный порт RS485. Плата с микропроцессором предназначена для логической обработки сигналов и смонтирована на основной плате. Программа управления хранится в стираемом программируемом ПЗУ (EPROM). Параметры, настройки и регистрируемые события хранятся в электрически стираемом программируемом ПЗУ (EEPROM). Все параметры вводятся с панели управления и индикации.

Скачать

CVM interface
Устройство сопряжения CVM предназначено для сопряжения контроллеров семейства CVM 200/300 и CVM 2000/3000 с системой централизованного контроля и управления технологическим оборудованием. Для интеграции технологического оборудования в единую систему контроля и управления используются несколько основных дискретных параметров управления холодильными агрегатами. Повтор сигналов производится через сухие контакты реле устройства сопряжения. Система централизованного контроля и управления позволяет подавать команды контроллеру, установленному на агрегате, через сухие контакты устройства сопряжения. Интеграция холодильных установок в систему централизованного контроля и управления осуществляется без преобразования интерфейса, так как согласование сигналов выполняется через контакты реле. Дискретные переменные отражают состояния агрегата, аварийной сигнализации и текущих режимов работы. Для настройки уставок первого и второго конура используются аналоговые сигналы 4-20 мА. Начальное программирование устройства сопряжения CVM осуществляется компанией CLIMAVENETA с помощью соответствующего программного обеспечения на основе исходных требований Заказчика. При включении устройства сопряжения CVM выполнять какую-либо настройку не требуется. Для правильной организации связи и согласования передачи информации необходимо настроить некоторые параметры контроллеров.

Скачать

Инструкции по эксплуатации стали незаменимым помощником для тех, кто столкнулся с новой технической разработкой впервые, ведь технический прогресс движется со скоростью света, и знать, как работает любое оборудование просто невозможно. Особенно, если дело касается промышленных агрегатов, в управление которых могут разобраться исключительно специалисты определенной отрасли. Агрегаты от компании Climaveneta носят промышленный характер и самостоятельно разобраться в принципе их функционирования достаточно сложно. Достаточно просто скачать инструкцию по эксплуатации, которая предоставляется абсолютно бесплатно и попытаться во всем разобраться. Весь материал изложен на русском языке, в удобном для всех формате pdf-файла. Помните, что при возникновении трудностей лучше все же обратиться к специалисту, который знает данную инструкцию, как свои пять пальцев.

Specifications:

106/106337-w3000_user_manual.pdf file (09 Jan 2023)

Accompanying Data:

CLIMAVENETA W3000 Chiller Control System, Thermostat PDF Operation & User’s Manual (Updated: Monday 9th of January 2023 05:10:47 AM)

Rating: 4.4 (rated by 60 users)

Compatible devices: T8112D, PRO 4000, CVM Manager, WIN100 Series, EUROSTER 4010, CVM 2, CVM 3000, TC-PBO01-BLK.

Recommended Documentation:

CLIMAVENETA W3000: Text of Operation & User’s Manual

(Ocr-Read Version Summary of Contents, UPD: 09 January 2023)

  • 1, W3000 Second Edition USER MANUAL C0240102-01-10-GB For software versions GA07 Replaces C0240 102-10-09-GB CLIMAVENETA S.p.A Via Sarson, 57C 36061 Bassano del Grappa(VI)-ITALY Tel. (+39) 0424 509 500 Fax (+39) 0424 509 509 http://www.climaveneta.it/ mailto:[email protected] H H The information contained i…

  • 35, C0240102-01-10-GB 35 Mask Description Par.N.  In/Out   Access mask to In/Out menu. Press «Up» or «Down» to scroll the other masks and «Esc» to return to the submenu. Dig. In. 12345 6789…

  • 8, C0240102-01-10-GB 8 1.3 Switching the unit on and off Caution: connect the unit to the power supply at least 8 hours before starting it; if this is not done, the guarantee will become null and void. There are different procedures for starting or stopping the unit: using the user interface keys or selecting from the display. The following procedures have a priority. In t…

  • 18, C0240102-01-10-GB 18 1.6.4 Modulating adjustment of screw compressors With screw compressors, modulating adjustment is performed on the outlet probe. Modulating adjustment is only available on “Bitzer” screw compressors. set point t [min] Tout [°C] ZN B (increase) C (decrease) Reference is made to the figure to the left: The setpoint remains within a dead area. If the t…

  • 41, C0240102-01-10-GB 41 Mask Description Par.N. Circ defr T.del T.dur 1 N 0904 0000 2 N 0000 0028 3 N 0904 0000 4 N 0000 0028 s s Displays the defrosting status, the delay before defrosting starts and the time taken to defrost…

  • 31, C0240102-01-10-GB 31 Mask Description Par.N.  Clock   Access mask to clock menu. Press «Up» or «Down» to scroll the other masks and «Esc» to return to the submenu. Clock b…

  • 19, C0240102-01-10-GB 19 1.6.5 Flexible step proportional adjustment on inlet + DIP on outlet probe This adjustment is performed by two independent adjusters: a) Proportional step (step adjuster) on the inlet probe; b) DIP (fine adjustment) on the outlet probe. The set point is identical for both adjusters. a) This is a proportional step adjust…

  • 10, C0240102-01-10-GB 10 Make sure the unit is “Off”. Access the “setpoint menu” and display the “Operating mode” parameter. Move to the “Operating mode” parameter by pressing [Enter] and modify the parameter by pressing [Up] or [Down]. Press [Enter] again to confirm. If the set message continues to be displayed it means that the operating mode has been c…

  • 13, C0240102-01-10-GB 13 1.6.1 Proportional step adjustment on inlet probe Some examples of proportional “step” adjustment on the inlet temperature probe: T in Banda proporzionale N % 50% 100% Set Set + banda proporzionale/2 Caso chiller (n° di gradini = 2) Figure 1.4: T B in Bis the input variable, NB % B is the number of active steps expressed in…

  • 4, C0240102-01-10-GB 4 1 USER INTERFACE There are two types of user interface: Depending on the type of user interface installed, there are more or less keys available for controlling the unit and for accessing system information. Key Description W3000 W3000 compact [MENU key]: accesses the main menu. [UP key]: moves around the masks and sets control pa…

  • 7, C0240102-01-10-GB 7 The menus are briefly described below: The “Unit Menu” displays information such as temperature, pressure and circuit states. The “Setpoint menu” is used to set the setpoints for the various available functions. Different setpoints can be set depending on the available operating modes (chiller, heat pump and recovery). Dual setpoint valu…

  • 30, C0240102-01-10-GB 30 Mask Description Par.N. Enable time bands : Disabled Activates/deactivates time bands. The time bands cannot be activated if the external setpoint is enabled. 39.41 Serial line configu…

  • 38, C0240102-01-10-GB 38 Mask Description Par.N. An. In. slave exp2 N° Value 1 04.2 bar 2 03.9 bar 3 35.6 °C 4 40.5 °C 5 22.3 °C 6 24.2 °C Displays analogue inputs 1, 2, 3, 4, 5 and 6 of slave expansion 2 (if present for 3 or 4 circuit units). An. In. slav…

  • 16, C0240102-01-10-GB 16 1.6.3 Quick mind adjustment Users must set the required setpoint as the other parameters are adapted to the system by the Quick Mind algorithm. QUICK MIND is a self-adapting algorithm for adjusting the temperature of the water treated by an all-in- one unit. The following figure shows how this adjustment is made: Tout ZONA NEUTRA Setpoint Attiva…

CLIMAVENETA W3000: Recommended Instructions

FRT15MB3A, 979, G0486, MCD700

  • USER’S GUIDETITLE: PRO-DIALOG CONTROL 4 FOR AIR & WATER COOLEDCHILLERS SERIES 30 GX & HXC VERSION 2REV: originalProperty of CARRIER S.A. Montluel.Not to be disclosed to persons outside the organization without Written authorizationSYNOPTIQUE CARRIER — AIR-COOLED BI CIRCUIT — ABC PARTNERS 08/06/98DATESPECIFICATIONN°COPY N°ECG CARRIER S.A. ECG-UG-00-00106/12/00 …

    30GX PRO 100

  • USAGE MANUALElectronic regulation for chillers and air and water cooled heat pumpsISO 9001 — Cert. n° 0128/4IGR3FX. 0810. 4724210_00GR3MANUEL D’UTILISATIONRéglage électronique pour producteurs d’eau glacée et pompes à chaleur à condensation par air et par eauBEDIENUNGSANLEITUNGElektronische Regelvorrichtung für Kaltwassersätze und Wärmepum …

    GR3 76

  • Test Run Manual April 2012Gas Heat Pump Air ConditionerApplicable Models2WAY MULTI/W MULTI U-16GE2E5 U-16GEP2E5 U-20GE2E5 U-20GEP2E5 U-25GE2E5 U-25GEP2E5 U-30GE2E5Reference No. SM7110029-01COVER.indd 1COVER.indd 1 2012/09/06 23:31:172012/09/06 23:31:17 …

    U-16GE2E5 60

  • Effective 6/98I.B. 48017Cutler-HammerInstructions for Converting AMPGARD™ Type LFMIsolation Switch With Type 25LFR2 DesignThis kit was specifically designed to replace old type LFMisolation switches supplied prior to July, 1975, with newtype 25 LFR2 isolation switches. The shutter assemblyhas been moved from the isolation switch to the startercell. This provides an insulating barrie …

    Cutler-Hammer AMPGARD 4

  • © 2000 McQuay InternationalMicroTech II™Applied Rooftop Unit ControllerSpace Comfort Control (SCC)• Used with McQuay models: RPS, RFS, RCS, RPR, RFR, RDT, RDS, RAR and RAHOperation Manual OM 138Group: Applied SystemsPart Number: OM138Date: April 2001Discharge CoolingDisch Air= 55.0°FClg Capacity= 50%Eff Clg Spt= 55°F …

    MicroTech II 109

  • ON Push 1x, display will show ON. During first start-up display will also flash the current frequency (50H=50Hz) after INIT; finally the room temperature will appear. Air-blower (CPAC) or evaporator water-pump (Chiller) will start. Depending on controller setting unit will start in cooling or heating mode. When unit won’t start, error codes will appear. See Troubleshoot …

    Azimut 43 Fly 12

  • MicroTech II™ Unit Ventilator Controlsfor AAF®-HermanNelson® Classroom Unit VentilatorsOperation Maintenance Manual OM 750Group: Unit VentilatorPart Number: 106506303Date: August 2002Supercedes: New©2002 AAF®-HermanNelson®Used with AAF-HermanNelson Classroom Unit VentilatorModel AVV, AVR – Floor MountedModel AHV, AHR – Ceiling MountedModel AZV, AZU, AZR – Floor Mounted …

    MicroTech II 32

  • W3000 Second Edition USER MANUAL C0240102-01-10-GB For software versions GA07 Replaces C0240102-10-09-GB CLIMAVENETA S.p.A Via Sarson, 57C 36061 Bassano del Grappa(VI)-ITALY Tel. (+39) 0424 509 500 Fax (+39) 0424 509 509 http://www.climaveneta.it/ mailto:[email protected] H H The information contained in this document may be modified without p …

    W3000 43

  • Rev. A 2-19-03 1 P/N 5202941. Open Load Center.Fold down OutdoorControl Panel.2. Plug Valve Module intoPersonality PCB.3. Attach Actuators. Ifnecessary, shut-offpower and removeHigh Voltage CoverPanel to feed cable upLow Voltage Raceway.4. Install High VoltageCover Panel. Fold upOutdoor Control Panel.Close Load Center.Turn on power.5. Configure system.(See Reverse side.)IntelliTouch® Val …

    IntelliTouch 2

  • Installation and MaintenanceIM 743-1Group: ControlsPart Number: IM 743Date: May 2005Supersedes: IM 743-0© 2005 McQuay InternationalMicroTech II®Chiller Unit ControllerModbus® Communication Module• WSC Water-Cooled Centrifugal, Single-Compressor• WDC Water-Cooled Centrifugal, Dual-Compressor• WPV Water-Cooled Centrifugal, Single-Compressor• HSC Water …

    IM 743 13

Additional Information:

Operating Impressions, Questions and Answers:

5 CLIMAVENETA Chiller Manuals and User Guides (53 Models) were found in All-Guides Database

CLIMAVENETA Chiller: List of Devices

# Model Type of Document
1 CLIMAVENETA BRIDGE iRS2

CLIMAVENETA Chiller BRIDGE iRS2 Manual  (6 pages)

2 CLIMAVENETA i-LIFE2
  • CLIMAVENETA Chiller i-LIFE2 Manual  (6 pages)

  • CLIMAVENETA Chiller i-LIFE2 Instructions for installation, use and maintenance manual (30 pages)

3 CLIMAVENETA a-LIFE3

CLIMAVENETA Chiller a-LIFE3 Instructions for installation, use and maintenance manual (30 pages)

4 CLIMAVENETA BRH 0011 FF

CLIMAVENETA Chiller BRH 0011 FF Installation, user & maintenance manual (34 pages)

5 CLIMAVENETA BRH 0021 FF

CLIMAVENETA Chiller BRH 0021 FF Installation, user & maintenance manual (34 pages)

6 CLIMAVENETA BRH 0025 FF

CLIMAVENETA Chiller BRH 0025 FF Installation, user & maintenance manual (34 pages)

7 CLIMAVENETA BRH 0031 FF

CLIMAVENETA Chiller BRH 0031 FF Installation, user & maintenance manual (34 pages)

8 CLIMAVENETA BRH 0041 FF

CLIMAVENETA Chiller BRH 0041 FF Installation, user & maintenance manual (34 pages)

9 CLIMAVENETA BRH 0051 FF

CLIMAVENETA Chiller BRH 0051 FF Installation, user & maintenance manual (34 pages)

10 CLIMAVENETA BRH 0061 FF

CLIMAVENETA Chiller BRH 0061 FF Installation, user & maintenance manual (34 pages)

11 CLIMAVENETA BRH 0071 FF

CLIMAVENETA Chiller BRH 0071 FF Installation, user & maintenance manual (34 pages)

12 CLIMAVENETA BRH 0091 FF

CLIMAVENETA Chiller BRH 0091 FF Installation, user & maintenance manual (34 pages)

13 CLIMAVENETA BRH 0101 FF

CLIMAVENETA Chiller BRH 0101 FF Installation, user & maintenance manual (34 pages)

14 CLIMAVENETA BRH 0121 FF

CLIMAVENETA Chiller BRH 0121 FF Installation, user & maintenance manual (34 pages)

15 CLIMAVENETA MICS FF

CLIMAVENETA Chiller MICS FF Installation, operating and service manual (32 pages)

16 CLIMAVENETA MICS-N FF

CLIMAVENETA Chiller MICS-N FF Installation, operating and service manual (32 pages)

17 CLIMAVENETA HRAN 0011

CLIMAVENETA Chiller HRAN 0011 Manual  (30 pages)

18 CLIMAVENETA HRAN 0021

CLIMAVENETA Chiller HRAN 0021 Manual  (30 pages)

19 CLIMAVENETA HRAN 0025

CLIMAVENETA Chiller HRAN 0025 Manual  (30 pages)

CLIMAVENETA Chiller: Popular and Often Search Manuals

CVM 2
Контроллер состоит из главной платы, расположенной в панели управления, и клавиатуры. К главной плате подключается плата управления скоростью вращения вентилятора. Клавиатура соединена с главной платой линией последовательной передачи информации по принципу токовой петли. Электропитание на клавиатуру подается с главной платы.

Скачать

CVM 20
Техническое описание блока CVM 20 Содержание: • Подключение внешних устройств • Подключение источника электропитания • Последовательные порты передачи данных • Программное обеспечение • Перечень аварийных сигналов • Регулирование • Вывод информации на принтер • Настройка • Список параметров

Скачать

CVM 300
Техническое руководство. Электронный контроллер CVM 300 для 1-компрессорных и 2-компрессорных агрегатов состоит из основной платы и панели управления. Обмен информацией между основной платой и панелью управления осуществляется через линию последовательной передачи информации по принципу токовой петли. На основной плате установлена плата с микропроцессором для управления агрегатами. Управляющая программа хранится в EPROM (СППЗУ), а параметры, данные калибровки и предыстории – в EERPOM (ЭСППЗУ). Параметры вводятся с клавиатуры панели управления.

Скачать

CVM 3000
КОсновная плата связана с панелью управления и индикации через линию последовательной передачи информации по принципу токовой петли, а с платой расширения – через последовательный порт RS485. Плата с микропроцессором предназначена для логической обработки сигналов и смонтирована на основной плате. Программа управления хранится в стираемом программируемом ПЗУ (EPROM). Параметры, настройки и регистрируемые события хранятся в электрически стираемом программируемом ПЗУ (EEPROM). Все параметры вводятся с панели управления и индикации.

Скачать

CVM interface
Устройство сопряжения CVM предназначено для сопряжения контроллеров семейства CVM 200/300 и CVM 2000/3000 с системой централизованного контроля и управления технологическим оборудованием. Для интеграции технологического оборудования в единую систему контроля и управления используются несколько основных дискретных параметров управления холодильными агрегатами. Повтор сигналов производится через сухие контакты реле устройства сопряжения. Система централизованного контроля и управления позволяет подавать команды контроллеру, установленному на агрегате, через сухие контакты устройства сопряжения. Интеграция холодильных установок в систему централизованного контроля и управления осуществляется без преобразования интерфейса, так как согласование сигналов выполняется через контакты реле. Дискретные переменные отражают состояния агрегата, аварийной сигнализации и текущих режимов работы. Для настройки уставок первого и второго конура используются аналоговые сигналы 4-20 мА. Начальное программирование устройства сопряжения CVM осуществляется компанией CLIMAVENETA с помощью соответствующего программного обеспечения на основе исходных требований Заказчика. При включении устройства сопряжения CVM выполнять какую-либо настройку не требуется. Для правильной организации связи и согласования передачи информации необходимо настроить некоторые параметры контроллеров.

Скачать

Инструкции по эксплуатации стали незаменимым помощником для тех, кто столкнулся с новой технической разработкой впервые, ведь технический прогресс движется со скоростью света, и знать, как работает любое оборудование просто невозможно. Особенно, если дело касается промышленных агрегатов, в управление которых могут разобраться исключительно специалисты определенной отрасли. Агрегаты от компании Climaveneta носят промышленный характер и самостоятельно разобраться в принципе их функционирования достаточно сложно. Достаточно просто скачать инструкцию по эксплуатации, которая предоставляется абсолютно бесплатно и попытаться во всем разобраться. Весь материал изложен на русском языке, в удобном для всех формате pdf-файла. Помните, что при возникновении трудностей лучше все же обратиться к специалисту, который знает данную инструкцию, как свои пять пальцев.

Понравилась статья? Поделить с друзьями:
  • Delux rel 228 инструкция по эксплуатации
  • Руководство по радионике
  • Сермион инструкция по применению цена отзывы аналоги цена в таблетках
  • Антигриппин анви инструкция по применению таблетки взрослым от чего
  • Ренгалин инструкция по применению сироп для детей отзывы