Aor ar one инструкция на русском

AOR AR-ONE Operating Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

®

AR-ONE

Ultra Wide Band

Communications Receiver

Operating manual

AOR, LTD.

loading

Related Manuals for AOR AR-ONE

Summary of Contents for AOR AR-ONE

  • Page 1
    ® AR-ONE Ultra Wide Band Communications Receiver Operating manual AOR, LTD.
  • Page 2: Table Of Contents

    1-6 Computer control —————————————————————————- 12 1-7 IF output and Spectrum Display Unit (SDU5600) ———————————— 12 2 Getting Started ——————————————————————————————— 13 2-1 Making the AR-ONE ready for operation ———————————————- 13 2-1-1 LCD —————————————————————————— 13 2-1-2 Connect the antenna ——————————————————— 13 2-1-3 Connect power —————————————————————- 13…

  • Page 3
    3 Memory channels and banks ———————————————————————— 24 3-1 Memory channel overview ————————————————————— 24 3-2 Storing VFO frequency and data into memory ————————————- 25 3-3 Memory read “M.RD” ——————————————————————— 26 3-4 Deleting memory channels ————————————————————— 27 4 SCAN – scanning memory channels ————————————————————-28 4-1 SCAN –…
  • Page 4
    7 Computer control ————————————————————————————— 52 7-1 How to send an RS-232C command ————————————————- 52 7-2 Power on the AR-ONE ——————————————————————- 52 7-3 Detailed RS-232C Command Listing of the AR-ONE —————————- 53 8 Reset ——————————————————————————————————— 66 9 Specifications ——————————————————————————————— 67 10 Optional Accessories ——————————————————————————— 70…
  • Page 5: Introduction

    1-1 Introduction Thank you for purchasing the AR-ONE Ultra Wide Band Communications receiver. The AR-ONE is designed using the very latest technology to ensure the highest levels of performance and reliability. To get the best possible results from your AR-ONE, we strongly recommend you to read this manual and familiarize yourself with the receiver.

  • Page 6: Taking Care Of Your Radio

    Always keep the AR-ONE free from dust and moisture. Use a soft, dry cloth to gently wipe the set clean, never use abrasive cleaners or organic solvents which may damage certain parts.

  • Page 7: Attention While Operating

    SAFETY NOTICE – Always disconnect the power supply from the AC outlet when not in use. If used mobile, it should be noted that the AR-ONE has NOT been manufactured or tested to meet any specific mobile safety requirements. The AR-ONE has no internally user adjustable parts.

  • Page 8
    & scan functions to operate. This is because the AR-ONE believes that it has found an active frequency when the squelch opens and “S” ‘squelch open’ icon is displayed to the left of the signal meter.
  • Page 9: Accessories Supplied

    AR-ONE receiver DC power cable Operating manual 1-5 Controls & functions Controls are located on the front with most connectors on the rear of the AR-ONE, a brief identification is given here: Front Panel 1. Volume control plus isolate power On/Off 2.

  • Page 10
    The REMOTE RS-232C connectors (17 & 18 above) are designed for connection directly to a RS-232C serial port of a PC. By daisy chaining the units, control of up to 99 AR-ONE receivers is possible from one PC. No interface is required, just a standard RS-232C straight cable.
  • Page 11: 1-5-1Keypad

    LOCK This key is intentionally small to reduce the chances of accidental operation. Key lock is useful when you do not wish an important frequency to be lost or the AR-ONE to be incorrectly set to a different frequency. To force the squelch open so that you may manually intervene to ensure that no weak signals are missed.

  • Page 12
    RF Attenuator. Move the cursor to select the desired parameter. The AUTO selection will work best for most of cases. Automatic Gain Control. Move the cursor to select the desired AGC time constant. Usually, FAST is used to receive CW, MEDIUM for AM and FM, and SLOW for SSB. When MANU is selected, any desired parameter (between 0 –…
  • Page 13: Computer Control

    CONFIG menu. Baud rates (transfer speed) can be set to 9600, 19200 (default) or 38400 bps. Since there are two independent RS-232C ports with the AR-ONE, it is possible to set an ‘address’ to facilitate connection of up to 99 AR-ONE receivers to a single PC.

  • Page 14: Getting Started

    2-1-3 Connect power Connect power to the DC power jack on the rear panel of the AR-ONE. For optimal performance use a regulated DC power supply (12 ~ 14 V with capacity 2A). Do not connect to a 24 V system.

  • Page 15: Squelch Circuit

    The AR-ONE will take approximately 4 — 5 seconds before information appears on the LCD. This is normal, while the AR-ONE microprocessor generates the ‘boot up data’ required to control the receiver. 2-3 Squelch Circuit In normal use, NOISE SQUELCH is used. However, LEVEL SQUELCH can be selected for search and scan operations.

  • Page 16: Vfo Selection

    6. To select NOISE SQUELCH, repeat above steps. 2-4 VFO selection The AR-ONE has ten (10) VFOs being identified as “V-A” through “V-J” on the top left of the LCD. The term VFO historically means ‘Variable Frequency Oscillator’ and today refers to a tunable data store which contains frequency, step, step-adjust, attenuator etc.

  • Page 17: Changing Frequency Using The Main Tuning Dial

    For your convenience, receive mode and tuning step size have been pre-programmed into the AR-ONE auto-mode band plan data at the factory to simplify operation of the receiver, especially while you familiarize yourself with all functions. Should you wish, the defaults may be manually overridden at anytime so that you may select an alternative receive mode and tuning step on any frequency.

  • Page 18: Auto Mode Selection

    WFM – Wide Band Frequency Modulation – used by VHF and UHF broadcast stations as excellent audio quality is available due to the relatively wide frequency bandwidth employed. Used only for local services such as VHF band stereo (received as mono on the AR-ONE) and UHF TV sound channels.

  • Page 19: Receive Mode Selection

    Note: Auto-mode is cancelled as soon as the receive mode, tuning step or other related data is changed. Remember that auto-STEP and auto-MODE are linked, reselect AUTO-MODE if either have been adjusted and you require the auto band plan selection. 2-5-2 Receive mode selection Any receive mode may be selected at any frequency within the receiver’s frequency coverage.

  • Page 20: If Bandwidth

    The bottom line of the LCD displays the icon “STEP SET” to indicate that the AR-ONE is Waiting for you to change the step size. Use the main tuning dial or arrow key to select the desired step size. To accept the displayed tuning step size, push the ENT key.

  • Page 21: Manually Selecting If Bandwidth

    An appropriate IF filter is automatically selected when auto mode is engaged. However any combination of IF filter and receive mode is possible in manual mode. When you have manually selected an IF filter bandwidth, auto mode will be disengaged, but the receive mode, step size, etc will be retained until they are changed manually.

  • Page 22: Att (Attenuator)

    When MANU is selected, a desired parameter can be entered between 0 ~ 255 in the Configuration Menu. 2-9 ATTENUATOR Activating the attenuator reduces signals to the RF input stages of the AR-ONE to prevent overloading, for example when the receiver is used in close proximity to strong transmissions.

  • Page 23: Rf Amplifier

    2-10 RF AMPLIFIER The AR-ONE features a preamplifier. The LCD icon “a” is used to display the setting in use. To change the RF Amplifier setting, push the FUNC key and then push the 5 key. Select a new AMP parameter from the list of ON, OFF, AUTO by rotating the main tuning…

  • Page 24: Offset

    2-11 OFFSET This function enables the receive frequency to be quickly SHIFTED by a predetermined value, this makes it easy to track duplex-transmissions or check repeater inputs/outputs. The locations for frequency offset storage are numbered 00 to 47 with 00 acting as OFF, this makes 47 locations available.

  • Page 25: Memory Channels And Banks

    Think of memory channels as pages in a notebook, each of which is numbered to identify it. Data may be written to each new page (memory channel) and each page may be overwritten with new data, they can be used over and over again. The AR-ONE has 1,000 memory channels and one priority channel.

  • Page 26: Storing Vfo Frequency And Data Into Memory

    100 channels. The memory banks are identified by the first BANK number 0, 1, 2, 3, 4, 5, 6. 7, 8 and 9 and the individual channels are numbered from 00 to 99. Examples are “000” for the first channel location in memory bank “0” and “099” for the last memory channel in memory bank “0”.

  • Page 27: Memory Read «M.rd

    “325” during an earlier example in the preceding section. Push the FUNC key and push the SCAN key to go into memory read mode, the “M.RD” icon appears on the top left of the LCD to confirm operation. The AR-ONE will monitor…

  • Page 28: Deleting Memory Channels

    The AR-ONE will display memory channel, mode, text comment (if one was used). The memory channel last used (for memory write or recall) will initially be displayed. If the desired memory channel is not immediately displayed, it may be recalled by keying in the required three digit location.

  • Page 29: Scan — Scanning Memory Channels

    During SCAN, the AR-ONE automatically recalls memory channels which contains data in numeric order and monitors them looking for activity. When an ‘active’ memory channel is located (when a signal is found and the squelch is open), the AR-ONE will temporarily stop scanning.

  • Page 30: Selecting A Scan Bank

    When SCAN has been selected, only the currently displayed memory bank WHICH CONTAINS DATA will be SCANNED, receive mode and frequency are unimportant. Any memory channels which contain no data (empty) will be ignored (skipped). 4-3 Selecting a scan bank The memory bank identifier (such as “3”) will be displayed on the middle right of the LCD.

  • Page 31: Search Mode

    To stop select scan, push the VFO key. 5 Search mode In search mode, the AR-ONE is programmed to automatically tune between two specified frequency limits looking for activity. Please refer to section 1-3 of this manual if you do not fully understand the function of SEARCH.

  • Page 32: Starting Program Search

    LO (lower) start frequency HI (upper) stop frequency Receive mode (or set to AUTO MODE) Step (if auto is not selected) Text comment The program search banks are identified by numbers (01 ~ 40). To help with identification, each bank may be labeled with an alphanumeric text comment. 5-2 Staring program search Presuming that data is already stored into a search bank ……

  • Page 33: Forcing The Search To Resume

    5-2-2 Forcing the search to resume If the AR-ONE stops on an unwanted busy frequency, rotate the main tuning dial knob or use the up arrow key or down arrow key to force the search process to resume from the current frequency displayed.

  • Page 34
    Use the main tuning dial, right arrow key, left arrow key or keypad to select the bank you wish to program or overwrite (The down arrow key is used to move through the menu). Push the down arrow key.
  • Page 35
    LO: Input the lower start frequency in MHz format (don’t push the ENT key). Push the down arrow key. HI: Input the higher end (stop) frequency in MHz format (don’t push the ENT key). Push the down arrow key.
  • Page 36
    MODE SET: Use the right arrow key or left arrow key or main tuning dial to select receive mode, the FUNC key is used as a short cut to “AUTO”. Note: If the receive mode is set to “AUTO”, the receive mode, channel step will be taken from the pre-programmed auto band plan data, for this reason the detailing will not be required and skipped.
  • Page 37: Deleting Search Banks

    To accept the data input, push the ENT key. 5-5 Deleting search banks A delete menu is provided so that you can delete program search data (of course you may simply overwrite the data, too) . While in search mode, the DELETE menu is accessed as follows: Push the FUNC key and then push the 3 key.

  • Page 38: Locking Out Unwanted Active Frequencies (Pass)

    Push the down arrow key. Using the main tuning dial, keypad, right arrow key or left arrow key, select the desired search bank. The “HI” and “LO” frequency limits will appear on the LCD along with any associated text comment to aid the identification of the required search bank. To delete the program search bank, push the ENT key.

  • Page 39: Deleting Pass Channels

    the PASS function before taking action or transmissions may be missed. While stopped on an unwanted frequency, push FUNC and then push the 9 key. The search process will resume. It will appear that all frequencies are still searched, however, locked out frequencies will be ‘passed over’, the search will not stop on locked out frequencies.

  • Page 40: Configuration Menu

    If pass channels have already been tagged for the current search bank, the icon “PAS” (PASS) will be displayed on the LCD. Push the FUNC key to delete the pass frequency. To exit from this menu, push the ENT key. 6 Configuration menu The configuration menu is used to set fundamental operating parameters and other variables which do not appear in any other menu heading.

  • Page 41: Configure Beep

    AUTO 6-1 Configure beep The AR-ONE emits confirmation ‘beeps’ while the keypad is used. A ‘HIGH’ pitched beep indicates correct operation while a ‘LOW’ pitched beep indicates that an error or unexpected entry has taken place. The volume of the beep is independent of the main volume control…

  • Page 42: Configure Lamp

    (LAMP). 6-2 Configure lamp The AR-ONE is equipped with high intensity green LEDs to illuminate the LCD and keypad when operating in areas of low level lighting. The lamp may be configured in three ways: AUTO: The lamp will automatically illuminate when the keypad or main tuning dial are used.

  • Page 43: Configure Dimmer

    (CONTRAST). 6-4 Configure contrast The AR-ONE is equipped with variable LCD contrast which is adjustable in 32 steps to provide best visibility under different viewing angles, extremes of ambient light & temperature (and between sets due to variation).

  • Page 44: Configure If-Gain (Intermediate Frequency Gain)

    is set OFF. The default setting for Manual AGC is 255, maximum gain control value. The value can be adjusted according to the receiving condition. To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to the “MANU AGC”…

  • Page 45: Configure Rf-Gain (Radio Frequency Gain)

    AR-ONE (connected via a male 9-pin to male 9-pin straight cable). To access the configuration menu, push the FUNC key and then push the 7 key.

  • Page 46: Configure Rmt-Id (Remote Id)

    To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to the “RMT-ID” selection point. Use the main tuning dial, the right arrow key or the left arrow key to change the AR-ONE’s RS-232C identification address.

  • Page 47: Configure Free (Scan Free And Search Free)

    This is useful if you wish to gain a snap shot of activity without the AR-ONE being tied to a busy frequency for long periods of time (such as when monitoring active commercial repeaters etc).

  • Page 48: Configure Rear Speaker

    6-12-1 Configure rear speaker To access the configuration menu, push the FUNC key and then push the 7 key. Push the down arrow key to move the cursor to the “REAR SP” selection point. This menu is to configure the rear speaker. Use the main tuning dial, the right arrow key or the left arrow key to select the desired rear speaker setting (ON or OFF).

  • Page 49: Configure Audio Filters (Hpf/Lpf)

    6-13 Configure audio filters (HPF / LPF) An audio HPF (High Pass Filter) and a LPF (Low Pass Filter) are available. 6-13-1 Configure audio HPF (high pass filter) The audio high pass filter is useful for limiting the audio bass response (allowing higher tones to pass) improving intelligibility in certain circumstances (such as low frequency whistles on AM, SSB &…

  • Page 50: Configure Audio Lpf (Low Pass Filter)

    6-13-2 Configure audio LPF (low pass filter) The audio low pass filter is useful to cut off high tones (allowing low tones to pass) to improve intelligibility of weak signals in close proximity to adjacent interference and to remove hiss making listening for extended periods easier on the ears. There are four available pass frequencies: 3KHz, 4KHz, 6KHz and 12KHz.

  • Page 51: Engaging Prio Channel

    The priority checking is accomplished by momentarily tuning the receive circuit to the priority frequency to see if it is active. If activity is found, the AR-ONE will remain on the active frequency until the signal disappears. If no activity is detected, the receiver returns to the VFO frequency, scan channel or search bank from where it originated.

  • Page 52: Configure If Output Frequency

    (Reference Signal). 6-17 Configure reference signal source The function enables you to select the reference signal of the receiver. The AR-ONE has a built-in stable reference oscillator, however, an external high stability 10 MHz reference (such as off-air atomic coupled) can be accepted from the SMA connector (marked as 10 MHz IN) on the rear panel of the AR-ONE.

  • Page 53: Computer Control

    (data transfer speed) may be set to 9600, 19200 or 38400 bps. 19200 bps is the factory default. It is also possible to set an ‘address’ to facilitate connection of up to 99 AR-ONE receivers to a single port for custom operation, the addresses may be set between the limits of 01 to 99 with 00 representing single radio operation.

  • Page 54: Detailed Rs-232C Command Listing Of The Ar-One

    Send a [CR] then re-send the command. Should problem persist, check your connections and try reducing the RS-232C baud rate. 7-3 Detailed RS-232C command listing of the AR-ONE Power on x: any key to power on the AR-ONE (it takes 4 sec.) Power off Power off ^Ann…

  • Page 55
    FREQUENCY RFnnnnnnnnnn (entry in Hz format) (VFO mode only) RFnn.nn (entry in MHz format) (VFO mode only) Vx nnnnnnnnnn (entry in Hz format) x: A – J (VFO) To read: RF <CR> Response: RFnnnnnnnnnn (Hz) STEP FREQUENCY STnnnnnn (entry in Hz format) (not available in search mode) STnn.nn (entry in kHz format) (not available in search mode)
  • Page 56
    BANDWIDTH BWn (n: 0 – 8) Auto mode will be disabled by this command n=0 0.5kHz n=1 3.0kHz n=2 6.0kHz n=3 8.5kHz n=4 16kHz n=5 30kHz n=6 100kHz n=7 200kHz n=8 300kHz To read: BW <CR> Response: BWn HPF (High Pass Filter) HPn (n: 0 –…
  • Page 57
    AGC (Automatic Gain Control) Acn (n: 0 – 2) n=0 AGC — OFF n=1 AGC — FAST n=2 AGC — SLOW n=3 AGC — MIDDLE To read: AC <CR> Response: ACn DE-EMPHASIS ENn (n: 0 – 5) Auto mode will be disabled by this command 25μS 50μS 75μS…
  • Page 58
    RF AMP (Amplifier) AMn (n: 0 – 2) n=0 RF AMP OFF n=1 RF AMP ON n=2 RF AMP AUTO To read: AM <CR> Response: AMn BFO FREQ (Beat Frequency Oscillator Frequency) BF +/-nnnn (nnnn: 0000 — +/- 3000Hz) Available in CW, LSB, USB mode only Default: CW +800Hz, USB +1500Hz, LSB -1500Hz To read: BF <CR>…
  • Page 59
    MANUAL GAIN (10.7 MHz AGC) MGnnn (nnn: 000 – 255) Default: 255 Note: Available only when the AGC is set to OFF To read: MG <CR> Response: MG nnn RF GAIN RGnnn (nnn: 000 – 255) Default: 255 Note: volume control knob must…
  • Page 60
    AUTO SIGNAL LEVEL n:0 Auto Signal Level off n:1 Auto Signal Level on While n is set to 1, and the squelch opens, the signal level and frequency information is sent to the PC To read: LC <CR> Response: SQm LMnnn RFnnnnnnnnnn m: 0 Noise squelch mode m: 1 Level squelch mode nnn: signal level from 000 to 999…
  • Page 61
    BACKLIT DIMMER LDn (n: 0 or 1) n: 0 NORMAL (Default) n: 1 DIMM To read: LD<CR> Response: LDn LCD CONTRAST LVnn (nn: 00 – 31) (Default: 12) To read: LV<CR> Response: LVnn BEEP LEVEL BVn (n: 0 – 9) (Default: 5) To read: BV<CR>…
  • Page 62
    DELAY TIME (SCAN DELAY AND SEARCH DELAY) DDn.n (n.n: 0.0 – 9.9 second) Default: 2.0 sec. nn: FF (hold) To read: DD<CR> Response: DDn.n or DDFF FREE SCAN SPn.n (n.n: 0.0 – 9.9 second) n.n: 0.0 FREE SCAN OFF (Default) n.n: 0.1 –…
  • Page 63
    SIGNAL LEVEL UNIT (in dBμV) – Read only LU nnn (-nnn – nnn) dBμV To read: LU<CR> Response: LU nnn SIGNAL LEVEL UNIT (in dBm) – Read only LB nnn (-nnn – nnn) dBm To read: LU<CR> Response: LB nnn SEARCH DATA SETTING –…
  • Page 64
    PASS FREQUENCY LIST – Read only PRnn (nn: 01 – 40) Bank number PR00 nnnnnnnnnn PR01 nnnnnnnnnn PRmm (mm: 00 – 49) Last channel will be 49 or blank (- — -) DELETE PASS FREQUENCY – Write only PDmmnn (mm: 01 – 40) Bank number (nn: 00 –…
  • Page 65
    MEMORY DATA LIST – Read only MAn (n: 0 – 9) Bank number, memory data between CH00 to CH10. MA Memory data for bank number higher than 10 [Example]: MXmnn MPn GAn RFnnnnnnnnnn AUn MDn BWn ATn AMn TMxxxxxxxx SELECT MEMORY ON/OFF GAn (n: 0 or 1) Memory select On/Off n: 0 OFF n: 1 ON…
  • Page 66
    SCAN/SEARCH RE-START n= 0 (default) no operation, scan does not automatically resume n= 1 scan resumes after 2 seconds, or after the time set with the DD command. To read: SG<CR> Response: SGn SELECT PRIORITY CHANNEL PPmnn m= 0-9 bank number nn= 00-99 channel number To read: PP<CR>…
  • Page 67: Reset

    Try the suggestions given in (1) then hold the ESC key while powering up the AR-ONE to ‘Soft reset’ the microprocessor. Should AR-ONE still appear to behave strangely, try a ‘hard reset’ of the microprocessor, as follows: Remove the receiver’s top cover and push the reset button while the receiver is powered ON (see picture below).

  • Page 68: Specifications

    9 SPECIFICATIONS Configuration: Triple conversion super heterodyne Frequency coverage: 10 KHz ~ 3.3 GHz (no gap) Receive mode: AM, NFM, WFM, USB, LSB, CW, DATA Sensitivity: AM: – 10 dB S/N, NFM: – 12 dB SINAD, CW/SSB: – 10 dB S/N 10 ~ 40 kHz: CW 22.3 μV 40 ~ 100 kHz: AM –…

  • Page 69
    THD: 20 dB> (< 10 %) Audio Output: 2.0 W (at 8 ohms, THD < 10 %) Power requirement: 13.5 V DC, < 2 A. (@ 1 W audio output) 50 Ω Antenna impedance: Antenna Connector: N type IF output level: -20 dBm (10.7 MHz or 455 kHz) Ext.
  • Page 70
    For better accuracy in signal level values, connect a spectrum analyzer such as SDU5600 to the receiver’s IF OUT port. Make sure that both the AR-ONE and SDU5600 (or similar) are set to communicate at the same RS232C port speed.
  • Page 71: Optional Accessories

    10 OPTIONAL ACCESSORIES EXT-ONE Separation kit (includes a control head adapter and 16 feet separation cable) MM8600 Mobile mounting bracket (receiver not included) PSU-ALPHA AC adapter ANTENNAS DA3200 16 element discone DA5000 commercial grade discone SA7000 twin element MA500 mobile whip LA390 high Q active indoor loop BNC connectors for MA500 and LA390 N connectors for DA3200, DA5000, SA7000 (SA7000 also includes BNC-N and BNC-PL259 adapters)

  • Page 72: Limited Warranty (Usa Only)

    AOR USA, Inc. (AOR) warrants the AR -ONE as described below: AOR will repair or exchange equipment as a result of defects in parts or workmanship for a period of one year from the date of original retail purchase from an authorized AOR dealer.

  • Page 73
    AOR’s limits on warranty pertain only to the repair or, at its option, replacement of defective products. AOR shall not be liable for any other damages, including consequential, incidental or otherwise, arising from any defect.
  • Page 74
    Manufacturer: AOR, LTD. 2-6-4, Misuji, Taito-Ku, Tokyo, 111-0055, Japan URL: www.aorja.com e-mail: mail@aorja.com US distributor: AOR USA, INC. 20655 S. Western Ave. Suite 112 Torrance, CA 90501, U.S.A Phone: 310-787-8615 Fax: 310-787-8619 URL: www.aorusa.com e-mail: info@aorusa.com Feb.20, 2012 Printed in Japan…

Описание

AOR AR-ONE профессиональный сканирующий приемник

Основные характеристики широкополосного сканирующего приемника AOR AR-ONE:

Диапазон принимаемых частот Rx, МГц 0.01–3300
Скорость сканирования, каналов/с: ~37
Виды модуляций AM NFM WFM USB LSB CW DATA
Шаг подстройки, гц / кГц 1, 10, 50, 100, 500 Гц / 1, 2, 5, 6.25, 9, 10, 12.5, 25, 50, 100 кГц + 1 МГц и выше с шагом в 1 Гц
Количество каналов памяти 1000
Типы источников питания внешний источник ±13,5V DC
Сопротивление антенн, Ом 50
Тип антенны / разъема на приемнике съемная N-type female (мама)
Напряжение питания, В DC ±13.5V DC, 2A
Ток потребления, прием, мА ~2000
Диапазон рабочих температур, °С -10…+50
Габаритные размеры ШхВхГ, мм 157 х 58 х 270
Вес, в сборе, кг ~2.2
Гарнитурный разъем да, 8 Ом
Выходная мощность аудио канала, мВт 2000, 8 Ом
Страна производитель Япония

Стандартный комплект поставки стационарного сканирующего приемника AOR AR-ONE

Сканирующий приемник AOR AR-ONE

ONE-PSU Блок питания, сетевой ~230-240V AC / ±13.5V DC, 2A
ONE-DC Кабель соединительный, для установки приемника в автомобиль
Инструкция по эксплуатации

Аксессуары для всеволнового сканирующего приемника AOR AR-ONE

Модель, наименование, краткие характеристики

1 ONE-PSU Блок питания, сетевой ~230-240V AC / ±13.5V DC, 2A
2 ONE-DC Кабель соединительный, для установки приемника в автомобиль
3 AOR MM8600 — автомобильное крепление
4 EXT-ONE — комплект выноса передней панели приемника AOR AR-ONE на 5 метров
5 AOR SDU5600 — анализатор спектра с возможностью подключения к компьютеру
6 AOR SA7000 — стационарная, широкополосная антенная система во влагозащищенном исполнении, Rx: 30 кГц — 2 ГГц
7 AOR DA3000 — стационарная, широкополосная дисконусная антенна, Rx: 30 МГц — 2 ГГц
8 AOR DA5000 — компактная, стационарная, широкополосная дисконусная антенна, Rx: 30 МГц — 2 ГГц, КУ 2.5 дБ
9 AOR LA400 — настольная широкополосная антенна
10 AOR WL500 — активная рамочная КВ антенна, Rx: 3,5 МГц — 30 МГц
11 N-type (male)/BNC (female) — высокочастотный переходник

  • Page 1
    ® ® AR-ONE Ultra Wide Band Communications Receiver Operating manual AOR, LTD.
  • Page 2: Table Of Contents

    1-5-2 Summary of keys ————————————————————- 1-6 Computer control ————————————————————- 1-7 IF output and Spectrum Display Unit (SDU5500, SDU5600) ——————— 2 Getting Started ————————————————————- 2-1 Making the AR-ONE ready for operation ———————————————— 2-1-1 LCD ————————————————————- 2-1-2 Connect the antenna ———————————————————— 2-1-3 Connect power ————————————————————-…

  • Page 3
    2-4-1-1 Entering frequency using the numeric keypad —————————- 2-4-1-2 Changing frequency using the main tuning dial ————————— 2-4-1-3 Changing frequency using UP arrow key or DOWN arrow key ——— 2-5 Changing receive mode ————————————————————— 2-5-1 Auto mode selection ————————————————————- 2-5-2 Receive mode selection ————————————————————- 2-6 Changing tuning step size ————————————————————-…
  • Page 4
    4-3 Selecting a SCAN bank ————————————————————— 4-4 Select SCAN ————————————————————- 4-4-1 Adding select scan channels in memory read ———————————— 4-4-2 Starting/Stopping select scan ——————————————————— 5 Search mode ————————————————————- 5-1 Search type ————————————————————- 5-1-1 Program search overview ————————————————————- 5-2 Starting Program search ————————————————————- 5-2-1 Reversing the direction of search —————————————————…
  • Page 5
    ——————————————————— 6-16-1 Selecting IF output frequency ——————————————————— 6-17 Configure reference signal source ——————————————————— 7 Computer control ——————————————————- 7-1 How to send an RS-232C command ——————————————————- 7-2 Power on the AR-ONE —————————————————— 7-3 Detailed RS-232C Command Listing of the AR-ONE ———————————-…
  • Page 6: Introduction

    1-1 Introduction Thank you for purchasing the AR-ONE Ultra Wide Band Communications receiver. The AR-ONE is designed using the very latest technology to ensure the highest levels performance and reliability. To get the best possible results from your AR-ONE, we strongly recommend you to read this manual and familiarize yourself with the receiver.

  • Page 7
    © This manual is protected by copyright AOR, LTD. 2003. No information contained in this manual may be copied or transferred by any means without the prior written consent of AOR, LTD. AOR and the AOR logo are trademarks of AOR, LTD. All other trademarks and names are acknowledged.
  • Page 8: Take Care Of Your Radio

    Always keep the AR-ONE free from dust and moisture. Use a soft, dry cloth to gently wipe the set clean, never use abrasive cleaners or organic solvents which may damage certain parts.

  • Page 9: Attention While Operating

    4. Currently displayed VFO data is saved at power down (to increase speed of operation and to reduce write cycles). For this reason, if the AR-ONE is powered down using the PWR/VOL control or external power is removed, the last displayed frequency will be lost and the frequency used prior to this will be displayed when next powered up.

  • Page 10
    & scan functions to operate. This is because the AR-ONE believes that it has found an active frequency when the squelch opens and “S” ‘squelch open’ icon is displayed to the left of the signal meter.
  • Page 11: Accessories Supplied

    AC power supply (may be supplied in some world market areas and in a separate carton) DC power cable Operating manual (this booklet) 1-5 Controls & functions Controls are located on the front with most connectors on the rear of the AR-ONE, a brief identification is given here:…

  • Page 12
    Front Panel 1. Volume control plus isolate power On/Off 2. Squelch control 3. Phones jack (3.5 mm mono or stereo may be used) 4. Escape key 5. Key Lock key 6. Monitor key 7. Function key 8. LCD (Liquid Crystal Display) 9.
  • Page 13
    The REMOTE RS-232C connector (16 & 17 above) is designed for connection directly to RS-232C serial port of a PC. By daisy chain of the units, you can control up to 99 AR-ONE with one PC. No interface is required, just a standard RS-232C straight cable. Connections…
  • Page 14: Keypad

    LOCK This key is intentionally small to reduce the chances of accidental operation. Key lock is useful when you do not wish an important frequency to be lost or the AR-ONE to be incorrectly set to a different frequency. The monitor key is used to force the squelch open so that you may manually intervene to ensure that no weak signals are missed.

  • Page 15
    Push this key to select VFO mode. There are 10 VFOs (VFO-A through VFO-J) with the AR-ONE. STEP Push the [FUNC] key, and then push to select the desired frequency step. MODE Push this key to select the desired receive mode.
  • Page 16
    S.SCAN Push the [FUNC] key, and then push this key to initiate SELECT SCAN. Push the [FUNC] key, and then push this key to delete the memory channel, search bank, and pass frequency. PRIO Push the [FUNC] key, and then push this key to initiate PRIORITY CHANNEL RECEIVE. RF AMP Push the [FUNC] key, and then push this key to activate/deactivate the RF amplifier function (ON/OFF/AUTO).
  • Page 17: Computer Control

    Computer control Connect the AR-ONE to the serial port of a computer using an RS-232C serial cable terminated in a 9-pin male connector. The RS-232C parameters may be defined using the CONFIG menu. Baud rates (transfer speed) set to either 4800 or 9600 bps. Since there are two independent RS-232C port with the AR-ONE, it is possible to set an ‘address’…

  • Page 18: Connect The Antenna

    A receive frequency range of the SA7000 is 30 KHz ~ 2000 MHz. 2-1-3 Connect power Connect the power to the DC power jack on the rear panel of the AR-ONE. Use either a supplied AC power adapter. Or a regulated DC power supply (12 ~ 14 V with capacity 2A) may be used.

  • Page 19: Squelch Circuit

    6. To select NOISE SQUELCH, repeat above steps. 2-4 VFO selection The AR-ONE has ten (10) VFOs being identified as “V-A” through “V-J” on the top left of LCD. The term VFO historically means ‘Variable Frequency Oscillator’ and today refers a tuneable data store which contains frequency, step, step-adjust, attenuator etc.

  • Page 20: Tuning Frequency

    step are automatically selected. 2-4-1 Tuning frequency 2-4-1-1 Entering a frequency using the numeric keypad While in VFO mode, enter the required frequency using MHz format followed by the ENT key. Example of frequency entry of 80.8 MHz Push the [8] key. Push the [0] key. Push the [.] key. Push the [8] key. Push the [ENT] key. Example of frequency entry of 954 KHz (0.954 MHz) Push the [.] key.

  • Page 21: Changing Receive Mode

    For your convenience, receive mode and tuning step size have been pre-programmed into the AR-ONE auto-mode band plan data at the factory to simplify operation of the receiver, especially while you familiarize yourself with all functions. Should you wish, the defaults be manually overridden at anytime so that you may select an alternative receive mode and tuning step on any frequency.

  • Page 22: Auto Mode Selection

    Used only for local services such as VHF band stereo (received as mono on the AR-ONE) and UHF TV sound channels. LSB – Lower Side Band – is form of SSB (Single Side Band). LSB tends not to be used commercially but is extensively used by Radio Amateurs on frequencies below 10 MHz.

  • Page 23: Receive Mode Selection

    When auto-mode is in operation, receive mode and tuning step size are automatically selected for you by the AR-ONE microprocessor. To activate auto-mode or reconfirm its selection while in VFO mode, Push and hold the MODE key for more than 2 seconds.

  • Page 24: If Bandwidth

    VFO key. The third row of the LCD will display the current default size. The bottom line of the LCD displays the icon “STEP SET” to indicate that the AR-ONE is waiting you to change the step size. Use the main tuning dial or arrow key to select the desired step size. To accept the displayed tuning step size, push the ENT key.

  • Page 25: Manually Selecting If Bandwidth

    air. However, it is not simply a case of using the narrowest filter at all times, particular modes require differing amounts of bandwidth in order to operate otherwise the receive system simply will not produce intelligible sound. Correct receive mode and IF bandwidth must always be selected for optimum reception. If the bandwidth selection is too narrow, distortion or signal break-up may occur.

  • Page 26: Agc (Automatic Gain Control)

    2-8 AGC (Automatic Gain Control) To change the AGC parameter setting, push the FUNC key and then push the ATT key. Selecting a new AGC parameter from the list of MANU, FAST, MID, SLOW by rotating the main tuning dial or arrow key. To accept the new AGC parameter, push the ENT key. When MANU is selected, a desired parameter can be entered between 0 ~ 255 in the Configuration Menu.

  • Page 27: Rf Amplifier

    When ATT is set to 10 dB, the ‘t1’ icon will display on top right of the LCD, When ATT is set to 20 dB, the ‘t2’ icon will display on top right of the LCD. 2-10 RF AMPLIFIER The AR-ONE features a preamplifier. The LCD icon “a” is used to display the setting in use.

  • Page 28: Offset

    To change the RF Amplifier setting, push the FUNC key and then push the 5 key. Selecting a new AMP parameter from the list of ON, OFF, AUTO by rotating the main tuning dial or arrow key. To accept the new AMP parameter, push the ENT key. 2-11 OFFSET This function enables receive frequency to be quickly SHIFTED by a predetermined values, this makes it easy to track duplex-transmissions or check repeater inputs/outputs.

  • Page 29: Using Pre-Programmed Frequency Offset Data

    use, it may appear rather long winged to toggle on/off in VFO mode. However even when programmed, frequency offset is in no way detrimental to normal operation. The acceptable range of frequency offset is 0 MHz to 999.999 MHz, of course if the offset is set to 0 MHz, the frequency will not change! Before the FREQUENCY OFFSET function be used, it first needs to be configured (unless factory programmed for certain bands).

  • Page 30: Memory Channels And Banks

    Think of memory channels as pages in a notebook each of which is numbered to identify it. Data may be written to each new page (memory channel) and each page may be overwritten with new data, they can be used over and over again. The AR-ONE has 1,000 memory channels and a priority channel.

  • Page 31
    Examples are “000” for the first channel location in memory bank “0” and “099” for the last memory channel in memory bank “0”. “415” is the location: memory bank “4” channel “15”. The data contents of memory and search banks are held in a EEPROM so that no backup battery is required for memory retention.
  • Page 32
    1) Start by selecting VFO mode then key in the frequency of 123.500 MHz, “mode and step size” are set to the default auto mode. Push the VFO key to set the AR-ONE into VFO mode. Push the 1 key. Push the 2 key.
  • Page 33: Memory Read «M.rd

    Push the FUNC key and the push the SCAN key to go into memory read mode, the “M.RD” icon appears on the top left of the LCD to confirm operation. The AR-ONE will monitor whatever memory channel you enter memory read.

  • Page 34: Deleting Memory Channels

    Push the ENT key to delete it or push ESC to abort. 4 SCAN – scanning memory channels The AR-ONE has a SCAN mode whereby the contents stored in the MEMORY CHANNELS ARE AUTOMATICALLY RECALLED AND MONITORED very quickly for activity –…

  • Page 35: Scan — Outline Introduction

    During SCAN, the AR-ONE automatically recalls memory channel which contains data in numeric order and monitors it looking for activity. When an ‘active’ memory channel is located (when a signal is found and the squelch is open), the AR-ONE will temporarily stop scanning.

  • Page 36: Select Scan

    To exit from SCAN mode, push the VFO key. 4-4 Select scan Select scan enables you to ‘tag’ memory channels to make a temporary list up to 50 channels in the same memory bank for scanning in a separate list called the SELECT SCAN LIST.

  • Page 37: Search Mode

    To stop select scan, push the VFO key. Search mode In search mode, the AR-ONE is programmed to automatically tune between two specified frequency limits looking for activity. Please refer to section 1-3 of this manual if you do not fully understand the function of SEARCH.

  • Page 38: Starting Program Search

    LO (lower) start frequency HI (upper) stop frequency Receive mode (or set to AUTO MODE) Text comment The program search banks are identified by numbers (01 ~ 40). To help with identification, each bank may be labeled with an alphanumeric text comment. 5-2 Staring program search Presuming that data is already stored into a search bank ……

  • Page 39: Reversing The Direction Of Search

    5-2-2 Forcing the search to resume If the AR-ONE stops on an unwanted busy frequency, rotate the main tuning dial knob or use the up arrow key or down arrow key to force the search process to resume from the current frequency displayed.

  • Page 40: Programming A Search Bank

    5-4 Programming a search bank Each of the 40 search banks may be programmed with different frequency limits, receive modes, etc. as listed in section 8-1-1 of this manual. Push the FUNC key, and then push the 6 key to access the “SRCH PROG” menu. Use the main tuning dial, or the right arrow key or the left arrow key or keypad to select the bank you wish to program or overwrite.

  • Page 41
    Push the down arrow key. Input the lower start frequency in MHz format (don’t push the ENT key).
  • Page 42
    Push the down arrow key. Input the higher end (stop) frequency in MHz format (don’t push the ENT key). Push the down arrow key.
  • Page 43
    MODE SET Use the right arrow key or left arrow key or main tuning dial to select receive mode, the SET key is used as a short cut to “AUTO”. Note: If the receive mode is set to “AUTO”, the receive mode, channel step will be taken from the pre-programmed auto band plan data, for this reason the detailing will not be required while programming so is kipped….
  • Page 44
    STEP Assuming that a receive mode other than “AUTO” was selected, you will be presented with the “STEP SET” menu. Use the main tuning dial or the right arrow key or left arrow key to select the required tuning step from the following: 0.001 (1Hz), 0.010 (10Hz), 0.500 (500Hz),…
  • Page 45: Deleting Search Banks

    To accept the data input, push the ENT key. 5-5 Deleting search banks A delete menu is provided so that you can delete program search data (of course you may simply overwrite the data, too) . While in search mode, the DELETE menu is accessed using the key sequence. Push the FUNC key and then push the 3 key.

  • Page 46: Locking Out Unwanted Active Frequencies (Pass)

    Using the main tuning dial, keypad, right arrow key or left arrow key, select the desired search bank. The “HI” and “LO” frequency limits will appear on the LCD along with any associated text comment to aid the identification of the required search bank. To delete the program search bank, push the ENT key.

  • Page 47: Deleting Pass Channels

    It is possible to lock out (PASS) unwanted frequencies while is program search mode. This is useful to eliminate unwanted permanent transmissions. It is important to understand the PASS function before taking action or transmissions may be missed. While stopped on unwanted frequency, push the FUNC and then push the 9 key. The search process will resume.

  • Page 48
    If pass channels have already been tagged for the current search bank, the icon “PAS” (PASS) will be displayed on the LCD. Push the FUNC key to delete the pass frequency. To exit from this menu, push the ENT key.
  • Page 49: Configuration Menu

    6 Configuration menu The configuration menu is used to set fundamental operating parameters and other variables which do not appear in any menu heading. BEEP Confirmation & error tone LAMP LCD& keypad illumination DIMM Backlit illumination dimmer CONTRAST LCD contrast adjustment OPENING MESSAGE Change the power-up message AGC (Automatic Gain Control) adjustment…

  • Page 50: Configure Beep

    Auto/THRU/25uS/75uS/750uS AUTO 6-1 Configure beep The AR-ONE emits confirmation ‘beeps’ while the keypad is used. A ‘HIGH’ pitched beep indicates correct operation while a ‘LOW’ pitched beep indicates that an error or unexpected entry has taken place. The volume of the beep is independent of the main volume control and can be separately defined.

  • Page 51: Configure Lamp

    Or, push the down arrow key to move to the next item on the configuration menu (LAMP). 6-2 Configure lamp The AR-ONE is equipped with high intensity green LEDs to illuminate the LCD and keypad when operating in areas of low level lighting.

  • Page 52: Configure Contrast

    Or, push the down arrow key to move to the next item on the configuration menu (CONTRAST). 6-4 Configure contrast The AR-ONE is equipped with variable LCD contrast which is adjustable in 32 steps to provide best visibility under different viewing angles, extremes of ambient light & temperature (and between sets due to variation).

  • Page 53: Configure If-Gain (Intermediate Frequency Gain)

    The manual AGC function is to adjust the receiver’s AGC (Automatic Gain Control) when it is set OFF. The default setting for Manual AGC is 255, maximum gain control value. The value can be adjusted according to the receiving condition. To access the configuration menu, push the FUNC key and then push the 7 key.

  • Page 54: Configure Rf-Gain (Radio Frequency Gain)

    The IF gain control reduces the amplification in the receiver’s IF circuits and has the effect reducing the sensitivity of the receiver. Normally, this is performed by the AGC system, and the control is left at maximum gain, but reducing the gain can be useful to limit noise when listening to CW or SSB signals.

  • Page 55: Configure Remote Bps (Baud Rate)

    Or, push the down arrow key to move to the next item on the configuration menu (RMT-ID). 6-9 Configure RMT-ID (Remote ID) When multiple units are connected via remote connectors, each AR-ONE must be assigned a different ID (address). The value is adjustable between 00 ~ 99. The default value is 00.

  • Page 56: Configure Delay (Scan Delay And Search Delay)

    Or, push the down arrow key to move to the next item on the configuration menu (DELAY). 6-10 Configure DELAY (Scan delay and Search delay) This parameter affects the time, the AR-ONE will remain on active frequency in scan mode or search mode once the received signal has disappeared and the squelch has closed. This Is particularly useful for customizing how long the receiver will wait for a reply before resuming scan or search.

  • Page 57: Free (Scan Free And Search Free)

    This is useful if you wish to gain a snap shot of activity without the AR-ONE being tied to a busy frequency for long periods of time (such as when monitoring active commercial repeaters etc).

  • Page 58: Configure Speaker

    (SPEAKER). 6-12 Configure SPEAKER The AR-ONE is equipped with 2 separate speakers, one is in the main receiver unit and the another one is in the control head (Note: This function is available only when an optional separation kit is used), and a phones jack. Each speaker / head phones output can be configured under this menu.

  • Page 59: Configure Headphones Output

    Or, push the down arrow key to move to the next item on the configuration menu (Audio Filter). 6-13 Configure audio filters (HPF / LPF) The AR-ONE is equipped with an audio HPF (High Pass Filter) and a LPF (Low Pass Filter). 6-13-1 Configure audio HPF (high pass filter)

  • Page 60
    There are four available pass frequencies: 50Hz, 200Hz, 300Hz, and 400Hz. The higher the frequency the more limited the audio bandwidth. For highest fidelity for listening, select 50Hz. The filter selection can be set to automode to select the proper filter setting automatically.
  • Page 61: Configure Audio Lpf (Low Pass Filter)

    pass filter setting (AUTO / 50Hz / 200Hz / 300 Hz or 400Hz). Push the ENT key to accept the data and return to a standard display. Alternatively, push the ESC key to abort entry. Or, push the down arrow key to move to the next item on the configuration menu (LPF). 6-13-2 Configure audio LPF (low pass filter) The audio low pass filter is useful to cut off high tones (allowing low tones to pass) to improve intelligibility of weak signals in close proximity to adjacent interference and to…

  • Page 62: Configure Prio-Ch (Priority Channel)

    The priority checking is accomplished by momentarily tuning the receive circuit to the priority frequency to see if it is active. If the activity is found, the AR-ONE will remain on the active frequency until the signal disappears. If no activity is detected, the receiver returns to the VFO frequency, scan channel or search bank from where it originated.

  • Page 63
    keeping an eye on a distress frequency while scanning or searching another frequency band. Note: Depending upon the frequency and mode stored as priority, an audible click may be heard when the priority function is in operation. This is quite normal and is caused by the internal switching of circuitry necessary to accomplish the frequency change (as two frequencies cannot simultaneously be monitored).
  • Page 64: Configure If Output Frequency

    Or, push the down arrow key to move to the next item on the configuration menu (IF output). 6-16 Configure IF output frequency The function enables you to tap the 2 IF signal (10.7MHz) or the 3 IF signal (455KHz) from the BNC (marked as 10.7MHz) type connector on the rear panel.

  • Page 65: Computer Control

    This completes the configuration settings. Computer control Connect the AR-ONE to one of the serial port of a computer using an RS-232C cable terminated in a 9-pin plug. The RS-232C parameters may be defined using the OCNFIGURATION menu. Baud rates (data transfer speed) may be set to 4800 or 9600 bps.

  • Page 66: Power On The Ar-One

    RS-232C baud rate. 7-2 Power on the AR-ONE Connect an RS-232C cable between the AR-ONE and a PC, type any key to power up the AR-ONE. 7-3 Detailed RS-232C command listing of the AR-ONE…

  • Page 67
    To read: RX <CR> Response: Memory manual mode MR MXmnn RFnnnnnnnnnn STnnnnnn Aun MDn BWn ATn AMn TMxxxxxxxx Memory scan mode MS MXmnn RFnnnnnnnnnn STnnnnnn Aun MDn BWn ATn Amn TMxxxxxxxx Memory select mode SM MXmnn RFnnnnnnnnnn STnnnnnn Aun MDn BWn Atn Amn TMxxxxxxxx Search mode SSmm RFnnnnnnnnnn STnnnnnn Aun MDn BWn Atn Amn…
  • Page 68
    To read: AU <CR> Response: 7-3-5 OPERATION MODE (n: 0 — 6) Auto mode will be disabled by this command FM (BW=16KHz,HPF=50Hz,LPF=3KHz,De-emphasis=750uS) AM (BW=6KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) CW (BW=0.5KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) (BW=3KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) (BW=3KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU) WFM (BW=200KHz, HPF=50Hz, LPF=12KHz, De-emphasis=75uS) NFM (BW=8.5KHz, HPF=50Hz, LPF=3KHz, De-emphasis=750uS) To read: MD <CR>…
  • Page 69
    400Hz AUTO To read: HP <CR> Response: 7-3-8 LPF (Low Pass Filter) (n: 0 – 3 & F) Auto mode will be disabled by this command 3KHz 4KHz 6KHz 12KHz AUTO To read: LP <CR> Response: 7-3-9 AGC (Automatic Gain Control) (n: 0 –…
  • Page 70
    7-3-11 RF ATT (Attenuator) (n: 0 –3) 10dB 20dB AUTO To read: AT <CR> Response: 7-3-12 RF AMP (Amplifier) (n: 0 – 2) RF AMP OFF RF AMP ON RF AMP AUTO To read: AM <CR> Response: 7-3-13 BFO FREQ (Beat Frequency Oscillator Frequency) BF +/-nnnn (nnnn: 0000 — +/- 3000Hz) Available in CW, LSB, USB mode only…
  • Page 71
    7-3-16 AF GAIN AGnnn (nnn: 000 –255) Default: 255 Note: The volume control knob must be turned fully counterclockwise To read: AG <CR> Response: AG nnn 7-3-17 MANUAL GAIN (10.7 MHz AGC) MGnnn (nnn: 000 – 255) Default: 255 Note: Available only when the AGC is set to OFF To read: MG <CR>…
  • Page 72
    To read: LM <CR> Response NSQm LMnnn — When the noise squelch is selected (nnn: 000 – 999) LSQm LMnnn — When the level squelch is selected (nnn: 000 – 999) m: 1 when the squelch is closed m: 0 when the squelch is opened 7-3-22 AUTO SIGNAL LEVEL (n: 0 or 1)
  • Page 73
    (n: 0 or 1) Available when LA is set to 2 (Auto). n: 0 BACKLIT OFF n: 1 BACKLIT ON (Default) To read: BL<CR> Response: 7-3-25 BACKLIT DIMMER (n: 0 or 1) n: 0 NORMAL (Default) n: 1 DIMM To read: LD<CR> Response: 7-3-26 LCD CONTRAST LVnn…
  • Page 74
    n: 1 To read: PO<CR> Response: 7-3-30 DELAY TIME (SCAN DELAY AND SEARCH DELAY) DDn.n (n.n: 0.0 – 9.9 second) Default: 2.0 sec. (hold) To read: DD<CR> Response: DDn.n DDFF 7-3-31 FREE SCAN SPn.n (n.n: 0.0 – 9.9 second) n.n : 0.0 FREE SCAN OFF (Default) n.n: 0.1 –…
  • Page 75
    To read: OL<CR> Response: OLmm nnnnnnnnnn (10 digit) 7-3-35 SIGNAL LEVEL UNIT (in dBuV) – Read only LU nnn (-nnn – nnn) dBuV To read: LU<CR> Response: LU nnn 7-3-36 SIGNAL LEVEL UNIT (in dBm) – Read only LB nnn (-nnn –…
  • Page 76
    Read search data of the current search bank SRnn (nn: 01 – 40) Search data in search bank 1 — 40 (n: 1 — 10) 4 Search data in search bank 1- 10 Search data in all search bank SRn SLnnnnnnnnnn Sunnnnnnnnnn AUn MDn BWn ATn AMn TTxxxxxxxx SRn — (Blank) 7-3-39 PASS FREQUENCY –…
  • Page 77
    QS%% Delete all search data and pass frequencies on all search banks 7-3-43 TRANSFER THE CURRENT SEARCH DATA TO VFO – Write only (n: 0 – 9) n: 0 VFO – A n: 1 VFO – B VFO – J (Default) 7-3-44 MEMORY DATA SETTING –…
  • Page 78
    n: 0 n: 1 To read: GA<CR> Response: 7-3-47 SELECT MEMORY LIST – Read only GRnn (nn: 00 – 99) Memory channel on the designated bank GR%% All channels (100channels maximum) (n: 0 – 9 ) List of 10 channels data Next 10 channels data [Example]: GRnn mxx ……
  • Page 79: Specifications

    8 SPECIFICATIONS Model: AR-ONE Configuration: Triple conversion super heterodyne Frequency coverage: 10 KHz ~ 3.3 GHz (no gap) Receive mode: AM, NFM, WFM, USB, LSB, CW, DATA Sensitivity: (AM mode – 10 dB S/N, NFM mode – 12 dB SINAD,…

  • Page 80
    10 ~ 40 KHz: CW 22.3 uV 40 ~ 100 KHz: AM – 4.5 uV, CW – 1.5 uV 100 KHz ~ 40 MHz: AM 2.5 uV, 2 ~ 40 MHz: AM – 1.5 uV, SSB/CW – 0.7 uV, NFM – 0.89 uV 40 MHz ~ 1 GHz: AM –…
  • Page 81: Optional Accessories

    AOR USA, Inc. (AOR) warrants its receivers as described below: AOR will repair or exchange equipment as a result of defects in parts or workmanship for a period of one year from the date of original retail purchase from an authorized AOR dealer.

  • Page 82
    Any and all implied warranties, including those pertaining to merchantability and utility for a specific purpose are limited to the duration of this limited warranty. AOR’s limits on warranty pertain only to the repair or, at its option, replacement of defective products. AOR shall not be liable for any other damages, including consequential, incidental or otherwise, arising from any defect.
  • Page 83
    If you have questions about this limited warranty, or the operation of your AOR product, contact AOR at (310) 787-8615 during normal business hours (9 am ~ 5 pm Pacific Time Zone), or write to AOR, 20655 S. Western Ave., Suite 112, Torrance, CA 90501. You may also send a fax to AOR at (310) 787-8619.
  • Page 84
    Manufacturer: AOR, LTD. 2-6-4, Misuji, Taito-Ku, Tokyo, 111-0055, Japan URL: www.aorja.com e-mail: post@aorja.com US distributor: AOR USA, INC. 20655 S. Western Ave. Suite 112 Torrance, CA 90501 Phone: 310-787-8615 Fax: 310-787-8619 URL: www.aorusa.com e-mail: info@aorusa.com…

Фирма AOR Ltd анонсировала AR-ONE как новую точку отсчета в ряду широкодиапазонных приемников, серьезный шаг в развитии технологии приема. AR-ONE предлагает профессионалу полный спектр возможностей для установки частот, режимов приема, шагов перестройки (вплоть до 1 Гц) и многих других параметров приемника. Компьютерное управление обеспечивает максимальную гибкость и динамичность. AR-ONE — это выбор профессионала для контроля современного мира радиосвязи. 
Области применения нового приемника: ведение электронного наблюдения, пеленгация, выявление неисправностей систем и многое другое.

Аксессуары для всеволнового сканирующего приемника AOR AR-ONE

ONE-PSU Блок питания, сетевой ~230-240V AC / ±13.5V DC, 2A
ONE-DC Кабель соединительный, для установки приемника в автомобиль
AOR MM8600 — автомобильное крепление
EXT-ONE — комплект выноса передней панели приемника AOR AR-ONE на 5 метров
AOR SDU5600 — анализатор спектра с возможностью подключения к компьютеру
AOR SA7000 — стационарная, широкополосная антенная система во влагозащищенном исполнении, Rx: 30 кГц — 2 ГГц
AOR DA3000 — стационарная, широкополосная дисконусная антенна, Rx: 30 МГц — 2 ГГц
AOR DA5000 — компактная, стационарная, широкополосная дисконусная антенна, Rx: 30 МГц — 2 ГГц, КУ 2.5 дБ
AOR LA380 — настольная широкополосная антенна — активный петлевой вибратор, Rx: 10 кГц — 500 МГц
AOR WL500 — активная рамочная КВ антенна, Rx: 3,5 МГц — 30 МГц
N-type (male)/BNC (female) — высокочастотный переходник

AOR AR-ONE

AOR AR-ONE — стационарный широкополосный сканирующий приемник профессионального уровня с возможностью сканирования частот с шагом в (один!) 1 Гц.

Все о приемнике AOR AR-ONE

Отзывы и обзоры пользователей приемника AOR AR-ONE (пока отсутствуют)

Программное обеспечение (софт) AOR AR-ONE

Инструкция по эксплуатации AOR AR-ONE Стандартный комплект поставки стационарного сканирующего приемника AOR AR-ONE

Купить AOR AR-ONE производителя AOR по низкой цене в нашем интернет-магазине. Если вам нужно узнать более подробную информацию о характеристиках AOR AR-ONE, получить техническую документацию, либо узнать отзывы – пожалуйста не стесняйтесь, звоните нашим менеджерам, они с удовольствием проконсультируют и расскажут об отзывах на AOR AR-ONE.
Посмотреть другие модели
AOR AR-ONE сертифицирован для продажи в России.

Понравилась статья? Поделить с друзьями:
  • Coldaway инструкция на русском турецкий противовирусный препарат
  • Гамма бета спектрометр мкс ат1315 инструкция
  • Магнелис в6 форте инструкция по применению цена отзывы аналоги таблетки
  • Руководство по апексу
  • Реланиум ампулы инструкция по применению цена отзывы аналоги